112 resultados para Continuous Optimization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ascorbate oxidase is the enzyme used to determine the content of ascorbic acid in the pharmaceutical and food industries and clinics analyses. The techniques currently used for the purification of this enzyme raise its production cost. Thus, the development of alternative processes and with the potential to reduce costs is interesting. The application of aqueous two-phase system is proposed as an alternative to purification because it enables good separation of biomolecules. The objective of this study was to determine the conditions to continuously pre-purify the enzyme ascorbate oxidase by an aqueous two-phase system (PEG/citrate) using rotating column provided with perforated discs. Under the best conditions (20,000 g/mol PEG molar mass, 10% PEG concentration, and 25% citrate concentration), the system showed satisfactory results (partition coefficient, 3.35; separation efficiency, 54.98%; and purification factor, 1.46) and proved suitable for the pre-purification of ascorbate oxidase in continuous process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 2(3-1) factorial experimental design was used to evaluate the performance of a perforated rotating disc contactor to extract alpha-toxin from the fermented broth of Clostridium perfringens Type A by aqueous two-phase system of polyethylene glycol-phosphate salts. The influence of three independent variables, specifically the dispersed phase flowrate, the continuous phase flowrate and the disc rotational speed, was investigated on the hold up, the mass transfer coefficient, the separation efficiency and the purification factor, taken as the response variables. The optimum dispersed phase flowrate was 3.0 mL/min for all these responses. Besides, maximum values of hold up (0.80), separation efficiency (0. 10) and purification factor (2.4) were obtained at this flowrate using the lowest disc rotational speed (35 rpm), while the optimum mass transfer coefficient (0. 165 h(-1)) was achieved at the highest agitation level (140 rpm). The results of this study demonstrated that the dispersed phase flowrate strongly influenced the performance of PRDC, in that both the mass transfer coefficient and hold up increased with this parameter. (c) 2007 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to oxygen may induce a lack of functionality of probiotic dairy foods because the anaerobic metabolism of probiotic bacteria compromises during storage the maintenance of their viability to provide benefits to consumer health. Glucose oxidase can constitute a potential alternative to increase the survival of probiotic bacteria in yogurt because it consumes the oxygen permeating to the inside of the pot during storage, thus making it possible to avoid the use of chemical additives. This research aimed to optimize the processing of probiotic yogurt supplemented with glucose oxidase using response surface methodology and to determine the levels of glucose and glucose oxidase that minimize the concentration of dissolved oxygen and maximize the Bifidobacterium longum count by the desirability function. Response surface methodology mathematical models adequately described the process, with adjusted determination coefficients of 83% for the oxygen and 94% for the B. longum. Linear and quadratic effects of the glucose oxidase were reported for the oxygen model, whereas for the B. longum count model an influence of the glucose oxidase at the linear level was observed followed by the quadratic influence of glucose and quadratic effect of glucose oxidase. The desirability function indicated that 62.32 ppm of glucose oxidase and 4.35 ppm of glucose was the best combination of these components for optimization of probiotic yogurt processing. An additional validation experiment was performed and results showed acceptable error between the predicted and experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Topliss method was used to guide a synthetic path in support of drug discovery efforts toward the identification of potent antimycobacterial agents. Salicylic acid and its derivatives, p-chloro, p-methoxy, and m-chlorosalicylic acid, exemplify a series of synthetic compounds whose minimum inhibitory concentrations for a strain of Mycobacterium were determined and compared to those of the reference drug, p-aminosalicylic acid. Several physicochemical descriptors (including Hammett`s sigma constant, ionization constant, dipole moment, Hansch constant, calculated partition coefficient, Sterimol-L and -B-4 and molecular volume) were considered to elucidate structure-activity relationships. Molecular electrostatic potential and molecular dipole moment maps were also calculated using the AM1 semi-empirical method. Among the new derivatives, m-chlorosalicylic acid showed the lowest minimum inhibitory concentration. The overall results suggest that both physicochemical properties and electronic features may influence the biological activity of this series of antimycobacterial agents and thus should be considered in designing new p-aminosalicylic acid analogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental design optimization (Box-Behnken design, BBD) was used to develop a CE method for the simultaneous resolution of propranolol (Prop) and 4-hydroxypropranolol enantiomers and acetaminophen (internal standard). The method was optimized using an uncoated fused silica capillary, carboxymethyl-beta-cyclodextrin (CM-beta-CD) as chiral selector and triethylamine/phosphoric acid buffer in alkaline conditions. A BBD for four factors was selected to observe the effects of buffer electrolyte concentration, pH, CM-beta-CD concentration and voltage on separation responses. Each factor was studied at three levels: high, central and low, and three center points were added. The buffer electrolyte concentration ranged from 25 to 75 mM, the pH ranged from 8 to 9, the CM-beta-CD concentration ranged from 3.5 to 4.5%w/v, and the applied run voltage ranged from 14 to 20 W. The responses evaluated were resolution and migration time for the last peak. The obtained responses were processed by Minitab (R) to evaluate the significance of the effects and to find the optimum analysis conditions. The best results were obtained using 4%w/v CM-beta-CD in 25 mM triethylamine/H(3)PO(4) buffer at pH 9 as running electrolyte and 17 kV of voltage. Resolution values of 1.98 and 1.95 were obtained for Prop and 4-hydroxypropranolol enantiomers, respectively. The total analysis time was around of 15 min. The BBD showed to be an adequate design for the development of a CE method, resulting in a rapid and efficient optimization of the pH and concentration of the buffer, cyclodextrin concentration and applied voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The population structure, reproductive period, and juvenile recruitment of Panopeus americanus were studied in order to enhance knowledge of its life cycle and reproductive strategy and promote the maintenance of its natural stocks in an impacted region. Specimens were collected in the remnant human-impacted mangrove at Araca, state of Sao Paulo, Brazil, at two-month intervals from January to November 2005, at low tide, with a capture effort by three people. The crabs were measured (carapace width, CW) and sexed. The total catch was 275 animals, including 132 males (48.0%); 127 females (46.2%), of which 39 were ovigerous (14.2% of total catch); and 16 individuals whose sex could not be identified (5.8%). No correlation was observed between water temperature and the number of collected individuals; however, there was a significant, positive correlation with salinity. Males were significantly larger than females. The size-frequency distribution was bimodal, reflecting the occurrende of more than one recruitment pulse and the differential abundance of adults during the period of study. The overall sex ratio was 1:0.97 favoring males, and was not significantly different from the expected value, i.e., this population fits the anomalous pattern of sex occurrence in size classes. Ovigerous females were captured in all sampled months, which explain the continuous recruitment observed. Expected low levels of individuals of different size classes in the population were not confirmed. All population aspects found here allowed us to infer that this population of P. americanus is well established in the impacted mangrove by virtue of its reproductive strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of this study was to compare bleeding patterns of women using a contraceptive combination of 30 mcg ethinylestradiol (EE) and 3 mg drospirenone (DRSP) continuously or cyclically. Menstrual-related symptoms were also evaluated. Study Design: This open, prospective, randomized study evaluated 78 women using the EE/DRSP combination continuously for 168 days or for six 28-day cycles, each followed by a 7-day hormone-free interval. A diary with pre-established scales was used to assess the frequency and intensity of bleeding and menstrual-related symptoms. Results: Amenorrhea increased with continuous use; 62.2% of women with continuous use were amenorrheic at the end of treatment (95% CI: 46.6-77.8%). Dysmenorrhea, headache, acne, nausea, edema and increased appetite improved significantly in the continuous-use group, and mastalgia and edema in the cyclic-use group (p<.05). Six subjects in the continuous-use group (15.4%) and three in the cyclic-use group (7.7%) discontinued due to adverse events. Conclusions: Continuous use was associated with amenorrhea and fewer menstrual-related symptoms compared to cyclic use. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The objective of this study was to evaluate the effects of a contraceptive pill containing ethinylestradiol (30 mcg) and drospirenone (3 mg) in a continuous regimen on lipid, carbohydrate and coagulation parameters. Study Design: This open, prospective, randomized study included 78 participants (mean age 27.8 years) who were randomized into two groups to use the pill continuously for 168 days or for six 28-day cycles with a 7-day hormone-free interval between cycles. Markers of lipid, carbohydrate and coagulation profiles were measured prior to initiation and after the 6 months of pill use. Results: No statistically significant differences were found between the two contraceptive regimens with respect to carbohydrate or lipid profiles or in the parameters related to coagulation. Conclusions: The contraceptive combination of ethinylestradiol and drospirenone used in a continuous regimen was associated with metabolic alterations similar to those found during the traditional cyclic regimen of oral contraceptive use. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity and obstructive sleep apnea (OSA) are both associated with the prevalence of major cardiovascular illnesses and certain common factors they are considered responsible for, such as stress oxidative increase, sympathetic tonus and resistance to insulin. Objective: The aim of the present study was to compare the effect of continuous positive airway pressure (CPAP) on oxidative stress and adiponectin levels in obese patients with and without OSA. Methods: Twenty-nine obese patients were categorized into 3 groups: group 1: 10 individuals without OSA (apnea-hypopnea index, AHI <= 5) who did not have OSA diagnosed at polysomnography; group 2: 10 patients with moderate to severe OSA (AHI >= 20) who did not use CPAP; group 3: 9 patients with moderate to severe OSA (AHI >= 20) who used CPAP. Results: Group 3 showed significant differences before and after the use of CPAP, in the variables of diminished production of superoxide, and increased nitrite and nitrate synthesis and adiponectin levels. Positive correlations were seen between the AHI and the superoxide production, between the nitrite and nitrate levels and the adiponectin levels, between superoxide production and the HOMA-IR, and between AHI and the HOMA-IR. Negative correlations were found between AHI and the nitrite and nitrate levels, between the superoxide production and that of nitric oxide, between the superoxide production and the adiponectin levels, between AHI and the adiponectin levels, and between the nitrite and nitrate levels and the HOMA-IR. Conclusions: This study demonstrates that the use of CPAP can reverse the increased superoxide production, the diminished serum nitrite, nitrate and plasma adiponectin levels, and the metabolic changes existing in obese patients with OSA. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To describe current practice for the discontinuation of continuous renal replacement therapy in a multinational setting and to identify variables associated with successful discontinuation. The approach to discontinue continuous renal replacement therapy may affect patient outcomes. However, there is lack of information on how and under what conditions continuous renal replacement therapy is discontinued. Design: Post hoc analysis of a prospective observational study. Setting. Fifty-four intensive care units in 23 countries. Patients: Five hundred twenty-nine patients (52.6%) who survived initial therapy among 1006 patients treated with continuous renal replacement therapy. Interventions: None. Measurements and Main Results., Three hundred thirteen patients were removed successfully from continuous renal replacement therapy and did not require any renal replacement therapy for at least 7 days and were classified as the ""success"" group and the rest (216 patients) were classified as the ""repeat-RRT"" (renal replacement therapy) group. Patients in the ""success"" group had lower hospital mortality (28.5% vs. 42.7%, p < .0001) compared with patients in the ""repeat-RRT"" group. They also had lower creatinine and urea concentrations and a higher urine output at the time of stopping continuous renal replacement therapy. Multivariate logistic regression analysis for successful discontinuation of continuous renal replacement therapy identified urine output (during the 24 hrs before stopping continuous renal replacement therapy: odds ratio, 1.078 per 100 mL/day increase) and creatinine (odds ratio, 0.996 per mu mol/L increase) as significant predictors of successful cessation. The area under the receiver operating characteristic curve to predict successful discontinuation of continuous renal replacement therapy was 0.808 for urine output and 0.635 for creatinine. The predictive ability of urine output was negatively affected by the use of diuretics (area under the receiver operating characteristic curve, 0.671 with diuretics and 0.845 without diuretics). Conclusions. We report on the current practice of discontinuing continuous renal replacement therapy in a multinational setting. Urine output at the time of initial cessation (if continuous renal replacement therapy was the most important predictor of successful discontinuation, especially if occurring without the administration of diuretics. (Crit Care Med 2009; 37:2576-2582)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Dasatinib is a BCR-ABL inhibitor, 325-fold more potent than imatinib against unmutated BCR-ABL in vitro. Phase II studies have demonstrated efficacy and safety with dasatinib 70 mg twice daily in chronic-phase (CP) chronic myelogenous leukemia (CML) after imatinib treatment failure. In phase I, responses occurred with once-daily administration despite only intermittent BCR-ABL inhibition. Once-daily treatment resulted in less toxicity, suggesting that toxicity results from continuous inhibition of unintended targets. Here, a dose-and schedule-optimization study is reported. Patients and Methods In this open-label phase III trial, 670 patients with imatinib-resistant or -intolerant CP-CML were randomly assigned 1: 1: 1: 1 between four dasatinib treatment groups: 100 mg once daily, 50 mg twice daily, 140 mg once daily, or 70 mg twice daily. Results With minimum follow-up of 6 months (median treatment duration, 8 months; range, = 1 to 15 months), marked and comparable hematologic (complete, 86% to 92%) and cytogenetic (major, 54% to 59%; complete, 41% to 45%) response rates were observed across the four groups. Time to and duration of cytogenetic response were similar, as was progression-free survival (8% to 11% of patients experienced disease progression or died). Compared with the approved 70-mg twice-daily regimen, dasatinib 100 mg once daily resulted in significantly lower rates of pleural effusion (all grades, 7% v 16%; P = .024) and grade 3 to 4 thrombocytopenia (22% v 37%; P = .004), and fewer patients required dose interruption (51% v 68%), reduction (30% v 55%), or discontinuation (16% v 23%). Conclusion Dasatinib 100 mg once daily retains the efficacy of 70 mg twice daily with less toxicity. Intermittent target inhibition with tyrosine kinase inhibitors may preserve efficacy and reduce adverse events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise is an effective intervention for treating hypertension and arterial stiffness, but little is known about which exercise modality is the most effective in reducing arterial stiffness and blood pressure in hypertensive subjects. Our purpose was to evaluate the effect of continuous vs. interval exercise training on arterial stiffness and blood pressure in hypertensive patients. Sixty-five patients with hypertension were randomized to 16 weeks of continuous exercise training (n=26), interval training (n=26) or a sedentary routine (n=13). The training was conducted in two 40-min sessions a week. Assessment of arterial stiffness by carotid-femoral pulse wave velocity (PWV) measurement and 24-h ambulatory blood pressure monitoring (ABPM) were performed before and after the 16 weeks of training. At the end of the study, ABPM blood pressure had declined significantly only in the subjects with higher basal values and was independent of training modality. PWV had declined significantly only after interval training from 9.44 +/- 0.91 to 8.90 +/- 0.96 m s(-1), P=0.009 (continuous from 10.15 +/- 1.66 to 9.98 +/- 1.81 m s(-1), P-ns; control from 10.23 +/- 1.82 to 10.53 +/- 1.97 m s(-1), P-ns). Continuous and interval exercise training were beneficial for blood pressure control, but only interval training reduced arterial stiffness in treated hypertensive subjects. Hypertension Research (2010) 33, 627-632; doi:10.1038/hr.2010.42; published online 9 April 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Despite antihypertensive therapy, it is difficult to maintain optimal systemic blood pressure (BP) values in hypertensive patients (HPT). Exercise may reduce BP in untreated HPT. However, evidence regarding its effect in long-term antihypertensive therapy is lacking. Our purpose was to evaluate the acute effects of 40-minute continuous (CE) or interval exercise (IE) using cycle ergometers on BP in long-term treated HPT. Methods: Fifty-two treated HPT were randomized to CE (n=26) or IE (n=26) protocols. CE was performed at 60% of reserve heart rate (HR). IE alternated consecutively 2 min at 50% reserve HR with 1 min at 80%. Two 24-h ambulatory BP monitoring were made after exercise (postexercise) or a nonexercise control period (control) in random order. Results: CE reduced mean 24-h systolic (S) BP (2.6 +/- 6.6 mm Hg, p-0.05) and diastolic (D) BP (2.3 +/- 4.6, p-0.01), and nighttime SBP (4.8 +/- 6.4, p < 0.001) and DBP (4.6 +/- 5.2 mm Hg, p-0.001). IE reduced 24-h SBP (2.8 +/- 6.5, p-0.03) and nighttime SBP (3.4 +/- 7.2, p-0.02), and tended to reduce nighttime DBP (p=0.06). Greater reductions occurred in higher BP levels. Percentage of normal ambulatory BP values increased after CE (24-h: 42% to 54%; daytime: 42% to 61%; nighttime: 61% to 69%) and IE (24-h: 31% to 46%; daytime: 54% to 61%; nighttime: 46% to 69%). Conclusion: CE and IE reduced ambulatory BP in treated HPT, increasing the number of patients reaching normal ambulatory BP values. These effects suggest that continuous and interval aerobic exercise may have a role in BP management in treated HPT. (c) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Hyperinflation with a decrease in inspiratory capacity (IC) is a common presentation for both unstable and stable COPD patients. As CPAP can reduce inspiratory load, possibly secondary to a reduction in hyperinflation, this study examined whether CPAP would increase IC in stable COPD patients. Methods: Twenty-one stable COPD patients (nine emphysema, 12 chronic bronchitis) received a trial of CPAP for 5 min at 4, 7 and 11 cmH(2)O. Fast and slow VC (SVC) were measured before and after each CPAP trial. In patients in whom all three CPAP levels resulted in a decreased IC, an additional trial of CPAP at 2 cmH(2)O was conducted. For each patient, a `best CPAP` level was defined as the one associated with the greatest IC. This pressure was then applied for an additional 10 min followed by spirometry. Results: Following application of the `best CPAP`, the IC and SVC increased in 15 patients (nine emphysema, six chronic bronchitis). The mean change in IC was 159 mL (95% CI: 80-237 mL) and the mean change in SVC was 240 mL (95% CI: 97-386 mL). Among these patients, those with emphysema demonstrated a mean increase in IC of 216 mL (95% CI: 94-337 mL). Six patients (all with chronic bronchitis) did not demonstrate any improvement in IC. Conclusions: The best individualized CPAP can increase inspiratory capacity in patients with stable COPD, especially in those with emphysema.