81 resultados para microfluidic device
Resumo:
A simultaneous optimization strategy based on a neuro-genetic approach is proposed for selection of laser induced breakdown spectroscopy operational conditions for the simultaneous determination of macronutrients (Ca, Mg and P), micro-nutrients (B, Cu, Fe, Mn and Zn), Al and Si in plant samples. A laser induced breakdown spectroscopy system equipped with a 10 Hz Q-switched Nd:YAG laser (12 ns, 532 nm, 140 mJ) and an Echelle spectrometer with intensified coupled-charge device was used. Integration time gate, delay time, amplification gain and number of pulses were optimized. Pellets of spinach leaves (NIST 1570a) were employed as laboratory samples. In order to find a model that could correlate laser induced breakdown spectroscopy operational conditions with compromised high peak areas of all elements simultaneously, a Bayesian Regularized Artificial Neural Network approach was employed. Subsequently, a genetic algorithm was applied to find optimal conditions for the neural network model, in an approach called neuro-genetic, A single laser induced breakdown spectroscopy working condition that maximizes peak areas of all elements simultaneously, was obtained with the following optimized parameters: 9.0 mu s integration time gate, 1.1 mu s delay time, 225 (a.u.) amplification gain and 30 accumulated laser pulses. The proposed approach is a useful and a suitable tool for the optimization process of such a complex analytical problem. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time. integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to Visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
During the first half of 2006 the city of Sao Paulo suffered three series of violent attacks against the security forces, civilians, and the government. The violent campaign also included a massive rebellion in prisons and culminated in the kidnapping of a journalist and the broadcast of a manifesto from the criminal organization PCC threatening the police and the government. Right after, the main device used to contain organized crime in the prisons was declared unconstitutional. This episode represents a prototypical example of the use of media-focused terrorism by organized crime for projection into the political communication arena.
Resumo:
Governmental programmes should be developed to collect and analyse data on healthcare associated infections (HAIs). This study describes the healthcare setting and both the implementation and preliminary results of the Programme for Surveillance of Healthcare Associated Infections in the State of Sao Paulo (PSHAISP), Brazil, from 2004 to 2006. Characterisation of the healthcare settings was carried out using a national database. The PSHAISP was implemented using components for acute care hospitals (ACH) or long term care facilities (LTCF). The components for surveillance in ACHs were surgical unit, intensive care unit and high risk nursery. The infections included in the surveillance were surgical site infection in clean surgery, pneumonia, urinary tract infection and device-associated bloodstream infections. Regarding the LTCF component, pneumonia, scabies and gastroenteritis in all inpatients were reported. In the first year of the programme there were 457 participating healthcare settings, representing 51.1% of the hospitals registered in the national database. Data obtained in this study are the initial results and have already been used for education in both surveillance and the prevention of HAI. The results of the PSHAISP show that it is feasible to collect data from a large number of hospitals. This will assist the State of Sao Paulo in assessing the impact of interventions and in resource allocation. (C) 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives To analyze the association between resting heart rate and blood pressure in male children and adolescents and to identify if this association is mediated by important confounders. Study design Cross-sectional study carried out with 356 male children and adolescents from 8 to 18 years old. Resting heart rate was measured by a portable heart rate monitor according to recommendations and stratified into quartiles. Blood pressure was measured with an electronic device previously validated for pediatric populations. Body fatness was estimated by a dual-energy x-ray absorptiometry. Results Obese subjects had values of resting heart rate 7.8% higher than nonobese (P = .001). Hypertensive children and adolescents also had elevated values of resting heart rate (P = .001). When the sample was stratified in nonobese and obese, the higher quartile of resting heart rate was associated with hypertension in both groups of children and adolescents. Conclusions This study confirms the existence of a relationship between elevated resting heart rate and increased blood pressure in a pediatric population, independent of adiposity, ethnicity and age. (J Pediatr 2011; 158:634-7).
Resumo:
Several high temperature superconductor (HTS) tapes have been developed since the late eighties. Due to the new techniques applied for their production, HTS tapes are becoming feasible and practical for many applications. In this work, we present the test results of five commercial HTS tapes from the BSCCO and YBCO families (short samples of 200 mm). We have measured and analyzed their intrinsic and extrinsic properties and compared their behaviors for fault current limiter (FCL) applications. Electrical measurements were performed to determine the critical current and the n value through the V-I relationship under DC and AC magnetic fields. The resistance per unit length was determined as a function of temperature. The magnetic characteristics were analyzed through susceptibility curves as a function of temperature. As transport current generates a magnetic field surrounding the HTS material, the magnetic measurements indicate the magnetic field supported by the tapes under a peak current 1.5 times higher than the critical current, I(c). By pulsed current tests the recovery time and the energy/volume during a current fault were also analyzed. These results are in agreement with the data found in the literature giving the most appropriate performance conductor for a FCL device (I(peak) = 4 kA) to be used in a 220 V-60 Hz grid.