109 resultados para low dose irradiation
Resumo:
The effect of butylated hydroxytoluene/butylated hydroxyanisole blend (BHT/BHA), and rosemary and oregano extracts, added individually or in combination, on lipid oxidation and fatty acid composition was investigated on irradiated frozen beef burgers. Irradiation treatment was carried out using a (60)CO semi-industrial irradiator at doses of 6, 7 and 8 kGy, and then the treated meat samples were stored at -20 degrees C for 90 days. Lipid oxidation and fatty acid composition of beef samples were evaluated by measurement of TBARS and gas chromatography, respectively. The results of the experiment showed that rosemary extract, applied alone and in combination with either BHT/BHA or oregano extracts was more effective in maintaining a low oxidation level in the samples compared to oregano extract used individually or in combination with BHT/BHA. Results also showed no significant differences (p > 0.05) in fatty acid composition in all analyzed samples, although some changes in terms of decreased PUFA and MUFA, beside of slight increase of SFA content were observed. However, these differences do not correlate positively neither with the irradiation dose nor the type of antioxidant. Thus, there is a potential application of these spices as natural antioxidants in irradiated meats. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The effect of addition of rosemary and oregano extracts on the sensory quality of irradiated beef burger was investigated. Batches of beef burgers were prepared with 400 ppm of rosemary or oregano extract and a group prepared with 200 ppm of synthetic butyl-hydroxytoluene (BHT)/butyl-hydroxy-anisol (BHA) was used as a control. Half of each formulation was irradiated at the maximum dose allowed for frozen meat (7 kGy). Samples were kept under frozen conditions (-20 degrees C) during the whole storage period, including during irradiation. Two analyses were performed after 20 and 90 days to verify the influence of the addition of the different types of antioxidants and the effect of irradiation and storage time on the acceptance of the product. Thirty-three and thirty-four untrained panelists were invited to participate in the first and second test, respectively. A structured hedonic scale ranging from 1 to 9 points was used in both analyses. BHT/BHA formulation obtained the highest score (6.73) and regarding the natural antioxidants, oregano received better acceptance (6.36). Irradiated samples formulated with oregano received a lower score, 6.03 in the first test and 5.06 in the second one, compared to the non-irradiated sample (6.36 and 5.79). In the second test (90 days), the sample formulated with BHT/BHA and which was irradiated received a higher score (6.59) when compared to the non-irradiated one (5.85). In both tests, the irradiated samples formulated with rosemary extract obtained a better score compared to the non-irradiated one, the scores being 5.00-3.82 and 5.00-3.76 in the first and second test, respectively. Our results allowed us to conclude that the natural antioxidants, rosemary and oregano extracts, present a good alternative for replacing synthetic additives in food industries, and that the irradiation process, in some cases, may help to enhance the sensory quality of food. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objective-Clinical trials of statins during myocardial infarction (MI) have differed in their therapeutic regimes and generated conflicting results. This study evaluated the role of the timing and potency of statin therapy on its potential mechanisms of benefit during MI. Methods and Results-ST-elevation MI patients (n = 125) were allocated into 5 groups: no statin; 20, 40, or 80 mg/day simvastatin starting at admission; or 80 mg/day simvastatin 48 hours after admission. After 7 days, all patients switched their treatment to 20 mg/day simvastatin for an additional 3 weeks and then underwent flow-mediated dilation in the brachial artery. As of the second day, C-reactive protein (CRP) differed between non-statin users (12.0 +/- 4.1 mg/L) and patients treated with 20 (8.5 +/- 4.0 mg/L), 40 (3.8 +/- 2.5 mg/L), and 80 mg/day (1.4 +/- 1.5 mg/L), and the daily differences remained significant until the seventh day (P < 0.0001). The higher the statin dose, the lower the elevation of interleukin-2 and tumor necrosis factor-alpha, the greater the reduction of 8-isoprostane and low-density lipoprotein(-), and the greater the increase in nitrate/nitrite levels during the first 5 days (P < 0.001). Later initiation of statin was less effective than its early introduction in relation to attenuation of CRP, interleukin-2, tumor necrosis factor-alpha, 8-isoprostane, and low-density lipoprotein(-), as well as in increase in nitrate/nitrite levels (P < 0.0001). At the 30th day, there was no longer a difference in lipid profile or CRP between groups; the flow-mediated dilation, however, was proportional to the initial statin dose and was higher for those who started the treatment early (P = 0.001). Conclusion-This study demonstrates that the timing and potency of statin treatment during MI are key elements for their main mechanisms of benefit.
Resumo:
Background: Coadministration of any statin with ezetimibe is as effective as using high doses of the same statin in the reduction Of tow-density lipoprotein cholesterol (LDL-c). There may be other effects called pleiotropics. Objective: To compare the effectiveness of 2 different treatments that obtain equivalent LDL-c reductions (80 mg of simvastatin, once a clay and coadministration of 10 mg of simvastatin and 10 mg of ezetimibe, once a day) over endothelial function and inflammation. Methods: Twenty-three randomized patients with hypercholesterolemia in a 2 X 2 crossover protocol were Studied. Endothelial function was analyzed by ultrasound assessment of endothelial dependent flow-mediated vasodilation of the brachial artery, and inflammation was estimated by high-sensitivity C-reactive protein (hs-CRP). Results: LDL-c reduction was similar between the 2 treatments with simvastatin/ezetimibe and with simvastatin (P < 0.001); no difference between treatments was found (P = 0.968). Both treatments improved significantly the endothelial function [3.61% with simvastatin/ezetimibe (P = 0.003) and 5.08%. with simvastatin (P < 0.001)]; no difference was found between the 2 treatments (P = 0.291). hs-CRP had a 23% reduction with simvastatin/ezetimibe (P = 0.004) and a 30% reduction with simvastatin alone (P = 0.01), with no significant difference between the 2 treatments (P = 0.380). Conclusion: The 2 forms of treatment presented similar pleiotropic effects: improvement in endothelial function and decrease in hsCRP levels.
Resumo:
Papain is a proteolytic enzyme that has been widely used as debridement agent for scars and wound healing treatment. However, papain presents low stability, which limits its use to extemporaneous or short shelf-life formulations. The purpose of this study was to entrap papain into a polymeric matrix in order to obtain a drug delivery system that could be used as medical device. Since these systems must be sterile, gamma radiation is an interesting option and presents advantages in relation to conventional agents: no radioactive residues are formed: the product can be sterilized inside the final packaging and has an excellent reliability. The normative reference for the establishment of the sterilizing dose determines 25 kGy as the inactivation dose for viable microorganisms. A silicone dispersion was selected to prepare membranes containing 2% (w/w) papain. Irradiated and non-irradiated membranes were simultaneously assessed in order to verify whether gamma radiation interferes with the drug-releasing profile. Results showed that irradiation does not affect significantly papain release and its activity. Therefore papain shows radioresistance in the irradiation conditions applied. In conclusion, gamma radiation can be easily used as sterilizing agent without affecting the papain release profile and its activity onto the biocompatible device is studied. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Wild chamomile (Matricaria chamomilla L.) is one of the most popular herbal materials with both internal and external use to cure different health disturbances. As a consequence of its origin, chamomile could carry various microbial contaminants which offer different hazards to the final consumer. Reduction of the microbial load to the in force regulation limits represents an important phase in the technological process of vegetal materials, and the electron beam treatment might be an efficient alternative to the classical methods of hygienic quality assurance. The purpose of the study was to analyze the potential application of the electron beam treatment in order to assure the microbial safety of the wild chamomile. Samples of chamomile dry inflorescences were treated in electron beam (e-beam) of 6 MeV mean energy, at room temperature and ambient pressure. Some loss of the chemical compounds with bioactive role could be noticed, but the number of microorganisms decreased as a function on the absorbed dose. Consequently, the microbial quality of studied vegetal material inflorescences was improved by e-beam. irradiation. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The aim of this study was to compare the effects of Low-intensity Laser Therapy (LILT) and Light Emitting Diode Therapy (LEDT) of low intensity on the treatment of lesioned Achilles tendon of rats. The experimental model consisted of a partial mechanical lesion on the right Achilles tendon deep portion of 90 rats. One hour after the lesion, the injured animals received applications of laser/LED (685, 830/630, 880 nm), and the same procedure was repeated at 24-h intervals, for 10 days. The healing process and deposition of collagen were evaluated based on a polarization microscopy analysis of the alignment and organization of collagen bundles, through the birefringence (optical retardation-OR). The results showed a real efficiency of treatments based on LEDT and confirmed that LILT seems to be effective on healing process. Although absence of coherence of LED light, tendon healing treatment with this feature was satisfactory and can certainly replace treatments based on laser light applications. Applications of infrared laser at 830 nm and LED 880 nm were more efficient when the aim is a good organization, aggregation, and alignment of the collagen bundles on tendon healing. However, more research is needed for a safety and more efficient determination of a protocol with LED.
Resumo:
Background and Objectives: Chronic autoimmune thyroiditis (CAT) remains the most common cause of acquired hypothyroidism There is currently no therapy that is capable of regenerating CAT-damaged thyroid tissue The objective of this study was to gauge the value of applying low-level laser therapy (LLLT) in CAT patients based on both ultrasound studies (USs) and evaluations of thyroid function and thyroid autoantibodies. Study Design/Materials and Methods: Fifteen patients who had hypothyroidism caused by CAT and were undergoing levothyroxine (LT4) treatment were selected to participate in the study Patients received 10 applications of LLLT (830 nm, output power 50 mW) in continuous mode, twice a week, using either the punctual technique (8 patients) or the sweep technique (7 patients), with fluence in the range of 38-108 J/cm(2) USs were performed prior to and 30 days after LLLT USs included a quantitative analysis of echogenicity through a gray-scale computerized histogram index (El). Following the second ultrasound (30 days after LLLT), LT4 was discontinued in all patients and, if required, reintroduced Truodothyronine, thyroxine (T4), free T4, thyrotropin, thyroid peroxidase (TPOAb) and thyroglobulin (TgAb) antibodies levels were assessed before LLLT and then 1, 2, 3, 6, and 9 months after LT4 withdrawal. Results: We noted all patients` reduced LT4 dosage needs, including 7 (47%) who did not require any LT4 through the 9-month follow-up The LT4 dosage used pre-LLLT (96 +/- 22 mu g/day) decreased in the 9th month of follow-up (38 23 mu g/day; P<0.0001) TPOAb levels also decreased (pre-LLLT = 982 +/- 530 U/ml, post-LLLT = 579 454 U/ml, P = 0 016) TgAb levels were not reduced, though we did observe a post-LLLT increase in the EI (pre-LLLT = 0 99 +/- 0.09, post-LLLT= 1.21 +/- 0.19, P=0.001) Conclusion: The preliminary results indicate that LLLT promotes the improvement of thyroid function, as patients experienced a decreased need for LT4, a reduction in TPOAb levels, and an increase in parenchymal echogenicity Lasers Surg. Med. 42:589-596, 2010. (C) 2010 Wiley-Liss, Inc
Resumo:
Purpose: To compare the sparing potential of cerebral hemispheres with intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) for whole-ventricular irradiation (WVI) and conventional whole-brain irradiation (WBI) in the management of localized central nervous system germ cell tumors (CNSGCTs). Methods and Materials: Ten cases of patients with localized CNSGCTs and submitted to WVI by use of IMRT with or without a ""boost"" to the primary lesion were selected. For comparison purposes, similar treatment plans were produced by use of 3D-CRT (WVI with or without boost) and WBI (opposed lateral fields with or without boost), and cerebral hemisphere sparing was evaluated at dose levels ranging from 2 Gy to 40 Gy. Results: The median prescription dose for WVI was 30.6 Gy (range, 25.2-37.5 Gy), and that for the boost was 16.5 Gy (range, 0-23.4 Gy). Mean irradiated cerebral hemisphere volumes were lower for WVI with IMRT than for 3D-CRT and were lower for WVI with 3D-CRT than for WBI. Intensity-modulated radiotherapy was associated with the lowest irradiated volumes, with reductions of 7.5%, 12.2%, and 9.0% at dose levels., compared with 3D-CRT. Intensity-modulated radiotherapy provided of 20, 30, and 40 Gy, respectively statistically significant reductions of median irradiated volumes at all dose levels (p = 0.002 or less). However, estimated radiation doses to peripheral areas of the body were 1.9 times higher with IMRT than with 3D-CRT. Conclusions: Although IMRT is associated with increased radiation doses to peripheral areas of the body, its use can spare a significant amount of normal central nervous system tissue compared with 3D-CRT or WBI in the setting of CNSGCT treatment. (C) 2010 Elsevier Inc.
Resumo:
Background: Risperidone (RSP) is a benzisoxazole antipsychotic agent used to treat schizophrenia and other psychiatric illnesses in adults and children (including those with autism). After oral administration, RSP is completely absorbed from the gastrointestinal tract and undergoes hydroxylation to yield 9-hydroxyrisperidone (9-OH-RSP), an active metabolite that has a pharmacologic profile and potency similar to RSP. Objectives: The aims of this study were to compare the relative bioavailability of a pharmaceutical-equivalent (test) formulation with a reference formulation of oral RSP 2 mg, both available commercially on the Brazilian pharmaceutical market, and to generate data regarding the oral bioavailability of the tested drug in healthy Brazilian volunteers. Methods: This single-dose, randomized-sequence, open-label, 2-period crossover study was conducted in healthy Brazilian volunteers from August to December 2008. Subjects were randomly assigned to receive the test formulation followed by the reference formulation or vice versa, with a 30-day washout period between doses. Study drugs were administered after a 12-hour overnight fast. For pharmacokinetic analysis, blood samples were drawn at 0 (baseline), 0.25, 0.5, 1, 1.5, 3, 5, 8, 12, 24, 48, 72, 96, and 120 hours after administration. Plasma concentrations of RSP and 9-OH-RSP were determined using LC-MS/MS. The test and reference formulations were to be considered bioequivalent if the 90% CIs for the geometric mean test/reference ratios were within a predetermined range of 80% to 125%, in accordance with the policies of the Brazilian Sanitary Surveillance Agency and the US Food and Drug Administration. Tolerability was determined using clinical assessments, monitoring of vital signs, analysis of laboratory test results, and subject interviews regarding adverse events. Results: A total of 22 subjects were enrolled (11 men, 11 women; mean [SD] age, 32 [12] years [range, 18-58 years]; weight, 70.4 [11.9] kg [range, 50-103 kg]; height, 1.67 [0.08] m [range, 1.56-1.80 m]; and body mass index, 25 [4] kg/m(2) [range, 18-29 kg/m(2)]). For RSP, mean (SD) C(max) values were 12.6 (2.7) and 16.0 (2.3) ng/mL for the test and reference formulations, respectively. For 9-OH-RSP, mean C(max) values were 17.8 (1.3) and 21.0 (1.7) ng/mL for the test and reference formulations. The 90% CIs for the mean test/reference ratios for RSP C(max), AUC(0-120), and AUC(0-infinity) were 74% to 82%, 75% to 85%, and 76% to 85%, respectively, and 83% to 87%, 75% to 79%, and 75% to 78% for 9-OH-RSP. The related adverse events (headache, low back pain, drowsiness, standing hypotension, local postvenipuncture ecchymoses, insomnia, nausea, and vomiting) were transient and mild. Conclusions: This single-dose study found that the test and reference formulations of oral RSP 2 mg did not meet the Brazilian and US regulatory criteria for bioequivalence in these fasting, healthy volunteers. The study formulations appeared to be well tolerated. (Clin Ther 2010;32:2106-2115) (C) 2010 Elsevier HS Journals, Inc.
Resumo:
Objective: We tested the hypothesis that combined 660 and 890 nm LED phototherapy will promote healing of diabetic ulcers that failed to respond to other forms of treatment. Research Design and Methods: A double-blind randomized placebo controlled design was used to study 23 diabetic leg ulcers in two groups of 14 patients. Group one ulcers were cleaned, dressed with 1% silver sulfadiazine cream and treated with ""placebo"" phototherapy (<1.0 J cm(-2)) twice per week, using a Dynatron Solaris 705 (R) device. Group two ulcers were treated similarly but received 3 J cm(-2) dose. Results: At each of 15,30,45,60,75, and 90 days of healing, mean ulcer granulation and healing rates were significantly higher for group two than the ""placebo"" group (P < 0.02). While ""placebo"" treated ulcers worsened during the initial 30 days, group two ulcers healed rapidly; achieving 56% more granulation and 79.2% faster healing by day 30, and maintaining similarly higher rates of granulation and healing over the ""placebo"" group all through. By day 90, 58.3% of group two ulcers had healed fully and 75% had achieved 90-100% healing. In contrast, only one ""placebo"" treated ulcer healed fully by day 90; no other ulcer attained >90% healing. Conclusion: Combined 660 and 890 nm light promotes rapid granulation and healing of diabetic ulcers that failed to respond to other forms of treatment. Lasers Surg. Med. 41:433-441, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
Recent studies have investigated whether low level laser therapy (LLLT) can optimize human muscle performance in physical exercise. This study tested the effect of LLLT on muscle performance in physical strength training in humans compared with strength training only. The study involved 36 men (20.8 +/- 2.2 years old), clinically healthy, with a beginner and/or moderate physical activity training pattern. The subjects were randomly distributed into three groups: TLG (training with LLLT), TG (training only) and CG (control). The training for TG and TLG subjects involved the leg-press exercise with a load equal to 80% of one repetition maximum (1RM) in the leg-press test over 12 consecutive weeks. The LLLT was applied to the quadriceps muscle of both lower limbs of the TLG subjects immediately after the end of each training session. Using an infrared laser device (808 nm) with six diodes of 60 mW each a total energy of 50.4 J of LLLT was administered over 140 s. Muscle strength was assessed using the 1RM leg-press test and the isokinetic dynamometer test. The muscle volume of the thigh of the dominant limb was assessed by thigh perimetry. The TLG subjects showed an increase of 55% in the 1RM leg-press test, which was significantly higher than the increases in the TG subjects (26%, P = 0.033) and in the CG subjects (0.27%, P < 0.001). The TLG was the only group to show an increase in muscle performance in the isokinetic dynamometry test compared with baseline. The increases in thigh perimeter in the TLG subjects and TG subjects were not significantly different (4.52% and 2.75%, respectively; P = 0.775). Strength training associated with LLLT can increase muscle performance compared with strength training only.
Resumo:
Peripheral nerves are structures that, when damaged, can result in significant motor and sensory disabilities. Several studies have used therapeutic resources with the aim of promoting early nerve regeneration, such as the use of low-power laser. However, this laser therapy does not represent a consensus regarding the methodology, thus yielding controversial conclusions. The objective of our study was to investigate, by functional evaluation, the comparative effects of low-power laser (660 nm and 830 nm) on sciatic nerve regeneration following crushing injuries. Twenty-seven Wistar rats subjected to sciatic nerve injury were divided into three groups: group sham, consisting of rats undergoing simulated irradiation; a group consisting of rats subjected to gallium-aluminum-arsenide (GaAlAs) laser at 660 nm (10 J/cm(2), 30 mW and 0.06 cm(2) beam), and another one consisting of rats subjected to GaAlAs laser at 830 nm (10 J/cm(2), 30 mW and 0.116 cm(2)). Laser was applied to the lesion for 21 days. A sciatic functional index (SFI) was used for functional evaluation prior to surgery and on days 7, 14, and 21 after surgery. Differences in SFI were found between group 660 nm and the other ones at the 14th day. One can observe that laser application at 660 nm with the parameters and methods utilised was effective in promoting early functional recovery, as indicated by the SFI, over the period evaluated.
Resumo:
BACKGROUND: Previous publications have documented the damage caused to red blood cells (RBCs) irradiated with X-rays produced by a linear accelerator and with gamma rays derived from a Cs-137 source. The biologic effects on RBCs of gamma rays from a Co-60 source, however, have not been characterized. STUDY DESIGN AND METHODS: This study investigated the effect of 3000 and 4000 cGy on the in vitro properties of RBCs preserved with preservative solution and irradiated with a cobalt teletherapy unit. A thermal device equipped with a data acquisition system was used to maintain and monitor the blood temperature during irradiation. The device was rotated at 2 r.p.m. in the irradiation beam by means of an automated system. The spatial distribution of the absorbed dose over the irradiated volume was obtained with phantom and thermoluminescent dosimeters (TLDs). Levels of Hb, K+, and Cl- were assessed by spectrophotometric techniques over a period of 45 days. The change in the topology of the RBC membrane was investigated by flow cytometry. RESULTS: Irradiation caused significant changes in the extracellular levels of K+ and Hb and in the organizational structure of the phospholipid bilayer of the RBC membrane. Blood temperature ranged from 2 to 4 degrees C during irradiation. Rotation at 2 r.p.m. distributed the dose homogeneously (92%-104%) and did not damage the RBCs. CONCLUSIONS: The method used to store the blood bags during irradiation guaranteed that all damage caused to the cells was exclusively due to the action of radiation at the doses applied. It was demonstrated that prolonged storage of Co-60-irradiated RBCs results in loss of membrane phospholipids asymmetry, exposing phosphatidylserine (PS) on the cells` surface with a time and dose dependence, which can reduce the in vivo recovery of these cells. A time- and dose-dependence effect on the extracellular K+ and plasma-free Hb levels was also observed. The magnitude of all these effects, however, seems not to be clinically important and can support the storage of irradiated RBC units for at last 28 days.
Resumo:
Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood. (C) 2010 Elsevier Ltd. All rights reserved.