94 resultados para entropy measure-valued solutions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhaled endotoxin (lipopolysaccharide, LPS) initiates an inflammatory response and leads to the expression of CR3 (CD11b/CD18) receptors on polymorphonuclear leukocytes (PMNs). We determined if PMN activation in nasal lavage fluid (NLF) is a possible biomarker of occupational endotoxin exposure. Seven subjects exposed to endotoxin provided NLF samples that were split into three aliquots (negative control - 1 M nicotinamide; sham; positive control - 11 eta g of exogenous LPS) and PMN activation was measured using a chemiluminometer. Differences in mean PMN activation were apparent, negative control: 548 +/- 15.65 RLU 100 mu l(-1); sham: 11469 +/- 2582 RLU 100 mu l(-1); positive control: 42026 +/- 16659 RLU 100 mu l (n = 7; p < 0.05). This technique shows promise as a diagnostic method for measuring upper airway LPS exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To report the conclusion of the Think Thank 8 on Compliance Discussions during the second ICI-RS meeting in 2010. Methods: During a 3-day meeting a group of specialists discussed bladder compliance, what it represents, how it can be measured and if it is clinically relevant. Results: Bladder compliance is the result of a mathematical calculation of the volume required for a unit rise of pressure measured during a cystometric filling. It gives an indication on how the different mechanisms in the bladder wall react on stretching. There is a need of standardization of measurement and suggestions for this are given in the text. Pitfalls are described and how to avoid them. There is a wide range of compliance values in healthy volunteers and groups of patients. Poor compliance needs to be defined better as it can have significant clinical consequences. Prevention and treatment are discussed. Conclusion: If compliance is correctly measured and interpreted, it has importance in urodynamic testing and gives information relevant for clinical management. Neurourol. Urodynam. 30:714-722, 2011. (C) 2011 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. The quality and effectiveness of myocardial protection are fundamental problems to expand the use of and consequently good outcomes of donated hearts for transplantation. Objective. The purpose of this investigation was to compare the cardioprotective effects of Krebs-Henseleit, Bretschneider-HTK, St Thomas, and Celsior solutions using a modified nonrecirculating Langendorff column model of isolated perfused rat heart during prolonged cold storage. Materials and Methods. After removal 36 rat hearts underwent isolated perfusion into a Langendorff apparatus using Krebs-Henseleit solution for a 15-minute period of recovery; we excluded organs that did not maintain an aortic pressure above 100 m Hg. Subsequently, we equally distributed the hearts into four groups according to the cardioprotection solution; group 1, Krebs-Henseleit (control); group II, Bretschneider-HTK; group III, St Thomas; and group IV, Celsior. Each heart received the specific cardioplegic solution at 10 C for 2-hour storage at 20 C, before a 15 minutes perfusion with Krebs-Henseleit solution for recovery and stabilization. After 60 additional minutes of perfusion, every 5 minutes we determined heart rate (HR), coronary flow (CF), left ventricular systolic pressure (LVSP), and positive and negative peak of the first derivative of left ventricular pressure (+dP/dt and dP/dt, respectively). Results. Comparative analysis by Turkey`s test showed the following performances among the groups at 60 minutes of reperfusion: HR: II = IV > III > I; CF: II = IV > I = III; LVSP: IV > I = II = III; +dP/dt: IV > I = II = III; and dP/dt: IV = II > I = II. Conclusion. Cardioprotective solutions generally used in clinical practice are not able to avoid hemodynamic alterations in hearts exposed to prolonged ischemia. Celsior solution showed better performance than Bretschneider-HTK, St Thomas, and Krebs-Henseleit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this prospective study was to perform a cross-cultural adaptation of the Functional Assessment Measure (FAM) into Brazilian Portuguese, and to assess the test-retest reliability. The instrument was translated, back-translated, pretested, and reviewed by a committee. The Brazilian version was assessed in 61 brain-injury patients. Intrarater and interrater reliability was verified by a test-retest procedure (intraclass correlation). Intrarater reliability was moderate-to-excellent; interrater reliability was moderate-to-excellent, with the exception of one item. The Brazilian version of the FAM has acceptable test-retest reliability. Results suggest the use of the Brazilian version of the FAM in the Brazilian population, for disability evaluation and outcome assessment. Further research is required to evaluate the psychometric properties of the scale. International Journal of Rehabilitation Research 34:89-91 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate influences of vitrification and warming of metaphase II (MII) mouse oocytes on survival, spindle dynamics. spindle morphology, and chromatin alignment on metaphase plates. Design: Experimental animal Study. Setting: University animal laboratory. Animal(s): Eight-week-old B6D2F1 mice. Intervention(s): Denuded MII oocytes were used fresh (control), exposed to vitrification/warming solutions (Sol Expos), or vitrified and warmed (Vitr). Main Outcome Measure(s): Oocyte recovery and survival after warming and the influence of solution exposure and cryopreservation on spindle dynamics and chromatin alignment. Result(s): Cryopreservation of two or 10 oocytes per straw resulted in recovery (100% +/- 0% and 95% +/- 4%, respectively; mean SE) and survival (95% 2% and 98% 2%, respectively). Immediately after warming (Vitr), significantly fewer oocytes assessed with immunocytochemistry contained spindles, compared with control and Sol Expos. When oocytes were placed into a 3 degrees 7C environment for 2 hours after exposure or warming, the ability to recognize spindles by immunocytochemistry was not significantly different between groups. Using live-cell time-lapse imaging with LC-Polscope, similar time-dependent spindle formation dynamics were observed. At 2 hours after collection or treatment, spindle morphology and length were not significantly different between the groups, nor was the incidence of aberrant alignment of chromatin on metaphase plates. Conclusion(s): Immediately after warming of vitrified MII oocytes, beta-tubulin is depolymerized and chromatin remains condensed on the metaphase plate. Within a 2-hour period, beta-tubulin repolymerizes, forming morphologically normal metaphase spindles with properly aligned chromatin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nocturnal melatonin pineal output is triggered by sympathetic outflow. Antidepressants that block norepinephrine neuronal uptake should increase pineal function. This can be monitored by measuring 6-sulfatoximelatonin (aMT6s), the main melatonin metabolite, in the urine. In this study, we compared the excretion of aMT6s before (baseline), one, and 21 days after administration of clomipramine to healthy subjects (n = 32). At the end of treatment, subjects were divided into responders (n = 12) and non-responders (n = 20) according to the improvement in their emotional state in three out of four domains (interpersonal tolerance, efficiency, well-being and feeling different from the usual self). There was no difference in aMT6s before clomipramine between responders and non-responders in any of the time intervals analysed (06:00-12:00, 12:00-18:00, 18:00-24:00 and 24:00-06:00 hours). At day one, but not at day 21, the fraction of aMT6s excreted during the time interval 24:00-06:00, relative to the total amount excreted by each subject per day, was significantly higher (P = 0.0287) than baseline (0.57 +/- 0.04) in responders. No significant difference was observed in non-responders. The increase in pineal function induced by clomipramine was restricted to day one, indicating that long-lasting adaptation restores pineal function. In addition, the day one increase in aMT6s was significantly increased only in the responders group, raising the possibility that the blocking of neuronal uptake is predictive of emotional improvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the growing evidence of poor psychosocial adjustment, at present there is no formal method of assessment of social adjustment in patients with temporal lobe epilepsy (TLE). First, we assessed social adjustment in patients with TLE using a self-report questionnaire and compared the results with those from quality-of-life (QOL) scales. Second, we verified the influence of cognitive performance and clinical variables of epilepsy on social adjustment and QOL We evaluated 35 people with TLE and 38 healthy controls. Patients had worse social adjustment, and it was correlated with worse perception of cognitive function. Attention and verbal memory dysfunctions were negatively correlated with social adjustment. However, there was no significant correlation between cognitive performance and QOL Regarding clinical variables, persons with left TLE showed worse social adjustment and patients with frequent seizures showed worse QOL These findings indicate the relevance of evaluating social adjustment and emphasize the importance of cognitive rehabilitation to improved social adjustment. (c) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Splanchnic perfusion is prone to early injury and persists despite normalization of global hemodynamic variables in sepsis. Volume replacement guided by oxygen derived variables has been recommended in the management of septic patients. Our hypothesis was that a hypertonic isoneotic solution Would improve the benefits of crystalloids replacement guided by mixed venous oxygen saturation. Methods: Seventeen anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live E. coli in 30 minutes. They were then randomized into three groups: control group (n = 3) bacterial infusion without treatment; normal saline (n = 7), initial fluid replacement with 32 mL/kg of normal saline during 20 minutes; hypertonic solution (n = 7), initial fluid replacement with 4 mL/kg of hypertonic solution during 5 minutes. After 30 and 60 Minutes, additional boluses of normal saline were administered when mixed venous oxygen saturation remained below 70%. Mean arterial pressure, cardiac output; regional blood flows, systemic and regional oxygen-derived variables, and lactate levels were assessed. Animals were observed for 90 minutes and then killed. Hystopathological analysis including apoptosis detection using terminal deoxynucleotidil transferase mediated dUTP-biotin nick end labeling was performed. Results: A hypodynamic septic shock was observed after bacterial infusion. Both the fluid-treated groups presented similar transient benefits in systemic and regional variables. A greater degree of gut epithelial cells apoptosis was observed in normal saline-treated animals. Conclusions: Although normalization of mixed venous oxygen saturation was not associated with restoration of markers of splanchnic or other systemic perfusion variables, the initial fluid savings with hypertonic saline and its latter effect on gut apoptosis may be of interest in sepsis management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Human immunodeficiency virus (HIV)associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HIV+LIPO-) and healthy subjects (Control). Methods: in a cross-sectional analyses, body composition was measured by bioelectrical impedance analysis (BIA), skinfold thickness (SF) and dual-energy x-ray absorptiometry (DXA) in 10 subjects from HIV+LIPO+ group; 22 subjects from HIV+LIPO- group and 12 from Control group. Results: There were no differences in age and body mass index (BMI) between groups. The fat mass (FM) (%) estimated by SF did not correlate with DXA in HIV+LIPO+ group (r = 0,46/p >0,05) and had fair agreement in both HIV groups (HIV+LIPO+ =0,35/ HIV+ LIPO- = 0,40). BIA had significant correlation in all groups (p < 0,05) and strong agreement, meanly in HIV groups, for FM (HIV+LIPO+ = 0,79/ HIV+LIPO- = 0,85/Control = 0,60) and for fat free mass (FFM) (HIV+LIPO+ = 0,93/ HIV+LIPO- = 0,92 / Control = 0,73). Discussion: Total fat mass can be measured by BIA with good precision, but not by SF in HIV-infected patients with LS. Segmental BIA, triciptal SF, circumferences of arms, waist and legs maybe alternatives that need more studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were: (1) to correlate surface (SH) and cross-sectional hardness (CSH) with microradiographic parameters of artificial enamel lesions; (2) to compare lesions prepared by different protocols. Fifty bovine enamel specimens were allocated by stratified randomisation according to their initial SH values to five groups and lesions produced by different methods: MC gel (methylcellulose gel/lactic acid, pH 4.6, 14 days); PA gel (polyacrylic acid/lactic acid/hydroxyapatite, pH 4.8, 16 h); MHDP (undersaturated lactate buffer/methyl diphosphonate, pH 5.0, 6 days); buffer (undersaturated acetate buffer/fluoride, pH 5.0, 16 h), and pH cycling (7 days). SH of the lesions (SH(1)) was measured. The specimens were longitudinally sectioned and transverse microradiography (TMR) and CSH measured at 10- to 220-mu m depth from the surface. Overall, there was a medium correlation but non-linear and variable relationship between mineral content and root CSH. root SH(1) was weakly to moderately correlated with surface layer properties, weakly correlated with lesion depth but uncorrelated with integrated mineral loss. MHDP lesions showed the highest subsurface mineral loss, followed by pH cycling, buffer, PA gel and MC gel lesions. The conclusions were: (1) CSH, as an alternative to TMR, does not estimate mineral content very accurately, but gives information about mechanical properties of lesions; (2) SH should not be used to analyse lesions; (3) artificial caries lesions produced by the protocols differ, especially considering the method of analysis. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the antibacterial efficacy of irrigating solutions and their combinations against Enterococcus faecalis. Study design. One hundred ten single-rooted human teeth were inoculated with E. faecalis and incubated for 21 days. Teeth were divided according to the irrigant: Group I (GI), 2.5% sodium hypochlorite solution (NaOCl); GII, 2.5% NaOCl + 10% citric acid; GIII, 2.5% NaOCl + apple cider vinegar; GIV, apple cider vinegar; GV, 2% chlorhexidine solution; GVI, 1% peracetic acid; GVII, saline solution. Microbiological samples were taken after root canal preparation and 7 days later. Data were submitted to ANOVA (5%). Results. All solutions promoted reduction of E. faecalis after instrumentation, but bacterial counts were higher in the final sample. GI, GV, and GVI had lower bacterial counts than the other groups. Conclusions. The irrigating solutions may present activity but do not eradicate E. faecalis in the root canal system. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112:396-400)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. Methods: One hundred twenty bovine dentin specimens were infected intraorally by using a removable orthodontic device. Thirty samples were used for each irrigant solution: 2% chlorhexidine and 1%, 2.5%, and 5.25% sodium hypochlorite (NaOCl). The solutions were used for 5, 15, and 30 minutes and at 2 experimental volumes, 500 mu L and 1 mL. The samples were stained by using acridine orange dye before and after the experiments and evaluated by using a confocal microscope. The percentage of biofilm, isolated cells, and noncolonized dentin was measured by using a grid system. Differences in the reduction or increase of the studied parameters were assessed by using nonparametric methods (P < .05). Results: The higher values of biofilm dissolution and noncolonized dentin were found in the 30-minute NaOCl group and in the 5-minute and 15-minute groups of 5.25% NaOCL. The use of 2% chlorhexidine solution did not improve the biofilm dissolution or increase the cleaning of the dentin in comparison with the NaOCl solutions (P < .05). Conclusions: Two percent chlorhexidine does not dissolve the biofilms. Thirty minutes of NaOCl are necessary to have higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison with the 5-minute and 15-minute contact times. (J Endod 2011;37:1134-1138)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in vitro study aimed to analyse the effect of a single application of TiF(4) and NaF varnishes and solutions to protect against dentin erosion. Methods: Bovine root dentin samples were pre-treated with NaF-Duraphat varnish (2.26%F, pH 4.5), NaF/CaF(2)-Duofluorid varnish (5.63%F, pH 8.0), NaF-experimental varnish (2.45%F, pH 4.5), TiF(4)-experimental varnish (2.45%F, pH 1.2), NaF solution (2.26%F, pH 4.5), TiF(4) solution (2.45%F, pH 1.2) and placebo varnish (pH 5.0, no-F varnish control). Controls remained untreated. Ten samples in each group were then subjected to an erosive demineralisation (Sprite Zero, 4x 90 s/day) and remineralisation (artificial saliva, between the erosive cycles) cycling for S days. Dentin loss was measured profilometrically after pretreatment and after 1, 3 and 5 days of de-remineralisation cycling. The data were statistically analysed by two-way ANOVA and Bonferroni`s post hoc test (p < 0.05). Results: After pre-treatment, TiF(4) solution significantly induced surface loss (1.08 +/- 0.53 mu m). Only Duraphat reduced the dentin loss overtime, but it did not significantly differ from placebo varnish (at 3rd and 5th days) and TiF(4) varnish (at 3rd day). Conclusions: Duraphat varnish seems to be the best option to partially reduce dentin erosion. However, the maintenance of the effects of this treatment after successive erosive challenges is limited. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study compared the clinical efficacy of 4% articaine (A200) and 0.5% bupivacaine (B200), both with 1: 200,000 epinephrine, for lower third molar removal. Study design: Fifty patients underwent removal of symmetrically positioned lower third molars, in 2 separate appointments, under local anesthesia either with A200 or B200, in a double-blind, randomized, and crossover manner. Time to onset, duration of postoperative analgesia, duration of anesthetic action on soft tissues, intraoperative bleeding, and hemodynamic parameters were evaluated. Results: A statistically significant difference between the time to onset of A200 (1.66 +/- 0.13 minutes) and B200 (2.51 +/- 0.21 minutes) was found (P < .05). There was no statistically significant difference in the duration of analgesia, whether the patient was subjected to osteotomy or not, regardless of the local anesthetic used (3 to 4 hours; P < .05). However, when patients received B200 they experienced a statistically significant longer period of anesthesia on the soft tissues as compared with when they had received A200 (around 5 hours and 4 hours, respectively, P < .05). The surgeon`s rating of intraoperative bleeding was considered very close to minimal for both anesthetics. In the surgeries with osteotomy, the comparison between A200 and B200 showed statistically significant differences in the diastolic (64 mm Hg and 68 mm Hg, respectively, P = .001) and mean arterial pressure (86 mm Hg and 89 mm Hg, respectively, P = .031) when data from all the surgical phases were pooled. Additionally, the mouth opening at the suture removal was statistically different for A200 and B200 solutions (91.90% +/- 3.00% and 88.57% +/- 2.38% of the preoperative measure, respectively) when surgeries required bone removal (P < .05). Conclusions: In comparison with 0.5% bupivacaine, 4% articaine (both with 1: 200,000 epinephrine) provided a shorter time to onset and comparable hemostasis and postoperative pain control with a shorter duration of soft tissue anesthesia in lower third molar removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Project: Serum samples may not be appropriate to assess lead (Pb) concentrations because they may contain artificially higher Pb concentrations compared with those measured in plasma samples. Here, we compared Pb concentrations in serum versus heparin plasma separated from blood collected with or without vacuum. We have also examined the effects of sample standing time on Pb concentrations measured in serum, heparin plasma, and EDTA plasma. Procedure: We studied plasma and serum samples from twelve healthy subjects. Blood samples were collected via venous drainage phlebotomy with and without vacuum into trace metal free tubes containing no anticoagulants (serum), or lithium heparin, or EDTA (to obtain plasma). Variable sample standing times (0, 5, and 30 min) prior to centrifugation were allowed. Plasma and serum Pb and iron concentrations were determined by inductively coupled plasma mass spectrometry. Plasma and serum cell-free hemoglobin concentrations were measured. Results: Pb concentrations in serum and in heparin plasma from blood samples collected with or without vacuum were similar and not associated with significant changes in iron or hemoglobin concentrations. The sample standing time (up to 30 min) did not affect Pb concentrations in serum or in heparin plasma, which were approximately 50% lower than those found in EDTA plasma. Conclusions: Serum or heparin plasma separated from blood samples collected via venous phlebotomy with or without vacuum are appropriate medium to assess Pb concentrations, independently of the sample standing time. (C) 2010 Elsevier GmbH. All rights reserved.