82 resultados para clinical practice guidelines
Resumo:
Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.
Resumo:
Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.
Resumo:
Objective. To analyze the psychometric properties of the Brazilian Portuguese version of the Beck Anxiety Inventory (BAI) in terms of its internal consistency, scores distribution, concurrent and discriminant validity, and factorial analysis in a sample of university students and social anxiety disorder (SAD) cases and non-cases. Methods. A sample of Brazilian university students from the general population (N = 2314) and a sample of university students identified as cases (N = 88) and non-cases (N = 90) of SAD were assessed, using as a parameter the Structured Clinical Interview for the DSM-IV. The different instruments were completed individually in the presence of an experienced rater. Results. The BAI showed adequate internal consistency (0.88-0.92) and discriminant validity, with 0.74 sensitivity and 0.71 specificity for a cut-off score of 10. The factorial analysis suggested a three-factor solution to be the most adequate. Conclusions. The version of the BAI studied is quite adequate to be used in the context of Brazilian university students, identifying the presence of anxiety indicators. However, its usefulness to screen for SAD seems limited.
Resumo:
PURPOSE. To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS. Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS. TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS. TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2011;52:4485-4496) DOI:10.1167/iovs.10-6932
Resumo:
Background: Metabolic syndrome (MS) prevalence between different populations in obese adolescents is scanty to date. Objective: To compare the MS prevalence and related risk factors in Brazilian and Italian obese adolescents. Methods: A total of 509 adolescents (110 Brazilian, 399 Italian), aged 15-19 years. Anthropometric characteristics, triglycerides (TG), total, low-density lipoprotein (LDL)-, high-density lipoprotein (HDL)-cholesterol, fasting plasma glucose (FPG), insulin, homeostasis model assessment of insulin resistance (HOMA-IR) and blood pressure were measured. Results: Age, body mass index (BMI) and BMI z-score were not significantly different between the two subgroups. BMI z-score, TG, FPG, HOMA-IR and systolic blood pressure (SBP) were significantly higher in boys than in girls both in Brazilian and Italian adolescents, while HDL-cholesterol levels were lower in boys than in girls. No significant differences were observed in BMI, LDL and total-cholesterol and DBP in two genders and groups. Insulin, FPG, HOMA-IR and TG were significantly higher, while LDL-cholesterol and SBP were significantly lower in Brazilian than in Italian subjects, both in males and females. HDL and total-cholesterol and diastolic blood pressure (DBP) were not significantly different between the two subgroups and genders. MS prevalence was higher in Brazilian than in Italian obese boys (34.8 vs. 23.6%, p < 0.001) and girls (15.6 vs. 12.5%, p < 0.01). The most frequently altered parameter was HOMA-IR both in subjects with MS (100% in Brazilian and 81.8% in Italian) and without MS (42.9% and 11.7%). Conclusion: Metabolic syndrome represents a worldwide emerging health problem in different ethnical populations, the alterations of the risk factors related to MS (different in their prevalence between different subgroups) being strictly linked to the degree of obesity.
Resumo:
Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
Osteoarthritis (OA) is a widely prevalent disease of the whole joint including cartilage, bone and soft tissues. Increasing importance of imaging including assessment of all joint structures has been recognized recently. Conventional radiography is still the first and most commonly used imaging technique for evaluation of a patient with a known or suspected diagnosis of OA. However, limitations have been revealed by recent MRI-based knee OA studies. MRI plays a crucial role in understanding the natural history of the disease and in guiding future therapies due to its ability to image the knee as a whole organ and to directly and three-dimensionally assess cartilage morphology and composition. It is crucial to use the appropriate MR pulse sequences to assess various OA features, and thus support from experienced musculoskeletal radiologists should be sought for study design, image acquisition and interpretation. The aim of this article is to describe the roles and limitations of conventional radiography and MRI in imaging of OA, and also to give insight into the use of other modalities such as ultrasound, scintigraphy, computed tomography (CT) and CT arthrography in clinical practice and research in OA, particularly focusing on the assessment of knee OA in the tibiofemoral joint.