83 resultados para Robotics, Automation
Resumo:
Due to the rapid depletion of water resources, water must be used more efficiently in agriculture to maintain current levels of yield in irrigated areas. The efficiency of irrigation systems can be increased by adjusting the amount of water applied to specific conditions of soil and crop, which may vary in a field. Taking into account spatial and temporal variability, it is evident that an equipment capable of providing different irrigation levels is necessary to meet the water requirement of the soil. This work aims to develop and evaluate a flow rate sprinkler to be used in center pivots or linear moving irrigation systems, with potential for utilization in irrigation scheduling. A prototype was developed by duplicating its calibrations, and discharge coefficient adjustment was carried out in the laboratory. To predict the flow rate, a successful model that represented the operation of the flow rate sprinkler was established. The calibration of the flow rate sprinkler prototype showed satisfactory statistical and technical results. Automation of the prototype was achieved by driving a step motor using communication from the parallel port of a microcomputer, which was controlled by a software developed for this purpose. The results were satisfactory and technically feasible.
Resumo:
The objective of this study was to compare the responses of the Salmonella/microsome microsuspension assay with the new microplate fluctuation protocol (MPF) for the evaluation of the mutagenic activity of environmental samples. Organic extracts of total particulate atmospheric air samples, surface waters, and effluents were tested in dose-response experiments. The assays were performed with strain TA98 in the absence and presence of S9 mix. Both protocols produced similar results, despite the fact that the maximum score of the MPF is limited to 48 wells, whereas in the regular plate assay it is possible to count up to 1,500 colonies using an automatic counter. Similar sensitivities based on the lowest dose that resulted in a positive response were obtained for both assays. The MPF procedure is less laborious (e.g., all-liquid format, use of multi-channel pipettors) and allows for automation of the pipetting and dispensing steps, thus, reducing time of the analysis which is particularly important in environmental quality monitoring programs or in effect-directed analysis. The results show that the MPF procedure is a promising tool to test environmental samples for mutagenic activity. Environ. Mol. Mutagen. 51:31-38, 2010. (C) 2009 Wiley-Liss, Inc.
Resumo:
We show the results in Chalishajar [Controllability of mixed Volterra-Fredholm-type integro-differential systems in Banach space, J. Franklin Inst. 344(1) (2007) 12-21] and Chang and Chalishajar [Controllability of mixed Volterra-Fredholm type integro-differential systems in Banach space, J. Franklin Inst., doi:10.1016/j. jfranklin.2008.02.002] are only valid for ordinary differential control systems. As a result the examples provided cannot be recovered as applications of the abstract results. (C) 2008 The Franklin Institute. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background: Perioperative complications following robotic-assisted radical prostatectomy (RARP) have been previously reported in recent series. Few studies, however, have used standardized systems to classify surgical complications, and that inconsistency has hampered accurate comparisons between different series or surgical approaches. Objective: To assess trends in the incidence and to classify perioperative surgical complications following RARP in 2500 consecutive patients. Design, setting, and participants: We analyzed 2500 patients who underwent RARP for treatment of clinically localized prostate cancer (PCa) from August 2002 to February 2009. Data were prospectively collected in a customized database and retrospectively analyzed. Intervention: All patients underwent RARP performed by a single surgeon. Measurements: The data were collected prospectively in a customized database. Complications were classified using the Clavien grading system. To evaluate trends regarding complications and radiologic anastomotic leaks, we compared eight groups of 300 patients each, categorized according the surgeon`s experience (number of cases). Results and limitations: Our median operative time was 90 min (interquartile range [IQR]: 75-100 min). The median estimated blood loss was 100 ml (IQR: 100-150 ml). Our conversion rate was 0.08%, comprising two procedures converted to standard laparoscopy due to robot malfunction. One hundred and forty complications were observed in 127 patients (5.08%). The following percentages of patients presented graded complications: grade 1, 2.24%; grade 2, 1.8%; grade 3a, 0.08%; grade 3b, 0.48%; grade 4a, 0.40%. There were no cases of multiple organ dysfunction or death (grades 4b and 5). There were significant decreases in the overall complication rates (p = 0.0034) and in the number of anastomotic leaks (p < 0.001) as the surgeon`s experience increased. Conclusions: RARP is a safe option for treatment of clinically localized PCa, presenting low complication rates in experienced hands. Although the robotic system provides the surgeon with enhanced vision and dexterity, proficiency is only accomplished with consistent surgical volume; complication rates demonstrated a tendency to decrease as the surgeon`s experience increased. (C) 2010 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
Context: The purpose of this article is to review the history of robotic surgery, its impact on teaching as well as a description of historical and current robots used in the medical arena. Summary of evidence: Although the history of robots dates back to 2000 years or more, the last two decades have seen an outstanding revolution in medicine, due to all the changes that robotic surgery has made in the way of performing, teaching and practicing surgery. Conclusions: Robotic surgery has evolved into a complete and self-contained field, with enormous potential for future development. The results to date have shown that this technology is capable of providing good outcomes and quality care for patients. (C) 2011 AEU. Published by Elsevier Espana, S.L. All rights reserved.
Resumo:
This study aimed to compare Petrifilm Aerobic Count (AC) plates and the conventional pour plate methodology using the de Man-Rogosa-Sharpe (MRS) agar for the enumeration of lactic acid bacteria (LAB) in fermented milks (FMs), with different starter cultures added. FM samples (n = 66) were collected and plated on both methodologies, with incubation under anaerobic conditions at 35C for 48 h. The count results were compared by analysis of variance (P <= 0.05) and regression analysis. No differences between the mean counts obtained by both methodologies were observed, even when distinct FMs were compared. Considering all samples, a high correlation level was obtained between Petrifilm AC and MRS agar (r = 0.92), but these indexes were lower in FMs with Streptococcus thermophilus and Lactobacillus delbrueckii subsp. bulgaricus (r = 0.90) and Lactobacillus fortis (r = 0.81). Despite some slight interferences, Petrifilm AC has proven to be a convenient methodology on enumerating LAB in FM.
Resumo:
Permanent hearing loss is a leading global health care burden, with 1 in 10 people affected to a mild or greater degree. A shortage of trained healthcare professionals and associated infrastructure and resource limitations mean that hearing health services are unavailable to the majority of the world population. Utilizing information and communication technology in hearing health care, or tele-audiology, combined with automation offer unique opportunities for improved clinical care, widespread access to services, and more cost-effective and sustainable hearing health care. Tele-audiology demonstrates significant potential in areas such as education and training of hearing health care professionals, paraprofessionals, parents, and adults with hearing disorders; screening for auditory disorders; diagnosis of hearing loss; and intervention services. Global connectivity is rapidly growing with increasingly widespread distribution into underserved communities where audiological services may be facilitated through telehealth models. Although many questions related to aspects such as quality control, licensure, jurisdictional responsibility, certification and reimbursement still need to be addressed; no alternative strategy can currently offer the same potential reach for impacting the global burden of hearing loss in the near and foreseeable future.