115 resultados para Liquid chromatography-diode array detection
Resumo:
The purpose of this work was to determine the safe shelf life of single-base propellants. The kinetic parameters relative to the consumption of the stabilizer diphenylamine (DPA) added to the propellant were determined as a function of the storage and ageing time. High Performance Liquid Chromatography (HPLC) with spectrophotometric detection was used to determine the DPA percentage before and after the artificial ageing at 60, 70 and 80 ºC. The experimental data were very well adjusted to a pseudo-first order kinetic model and the respective kinetic constants are 8.0-10-3 day-1 (60 ºC); 1.9-10-2 day-1 (70 ºC); 1.2-10-1 day-1 (80 ºC). The activation energy was calculated as 130 kJ mol-1 and the half-time for depletion of the DPA at the hypothetical temperature of 40 ºC of storage was estimated as being 6 years.
Resumo:
Background: Brazilian propolis type 6 (Atlantic forest, Bahia) is distinct from the other types of propolis especially due to absence of flavonoids and presence of other non-polar, long chain compounds, but presenting good in vitro and in vivo antimicrobial activity. Several authors have suggested that fatty acids found in this propolis might be responsible for its antimicrobial activity; however, so far no evidence concerning this finding has been reported in the literature. The goals of this study were to evaluate the antibacterial activity of the main pure fatty acids in the ethanolic extract and fractions and elucidate the chemical nature of the bioactive compounds isolated from Brazilian propolis type 6. Methods: Brazilian propolis type 6 ethanolic extract (EEP), hexane fraction (H-Fr), major fatty acids, and isolated sub-fractions were analyzed using high performance liquid chromatography (HPLC), high resolution gas chromatography with flame ionization detection (HRGC-FID), and gas chromatography-mass spectrometry (GC-MS). Three sub-fractions of H-Fr were obtained through preparative HPLC. Antimicrobial activity of EEP, H-Fr, sub-fractions, and fatty acids were tested against Staphyloccus aureus ATCC 25923 and Streptococcus mutans Ingbritt 1600 using minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC). Results: EEP and H-Fr inhibited the growth of the microorganisms tested; nevertheless, no antimicrobial activity was found for the major fatty acids. The three sub-fractions (1, 2, and 3) were isolated from H-Fr by preparative HPLC and only sub-fraction 1 showed antimicrobial activity. Conclusion: a) The major fatty acids tested were not responsible for the antimicrobial activity of propolis type 6; b) Sub-fraction 1, belonging to the benzophenone class, was responsible for the antimicrobial activity observed in the present study. The identification of the bioactive compound will improve the development of more efficient uses of this natural product.
Resumo:
The objective of this work was to develop and validate a rapid Reversed-Phase High-Performance Liquid Chromatography method for the quantification of 3,5,3 '-triiodothyroacetic acid (TRIAC) in nanoparticles delivery system prepared in different polymeric matrices. Special attention was given to developing a reliable reproductive technique for the pretreatment of the samples. Chromatographic runs were performed on an Agilent 1200 Series HPLC with a RP Phenomenex (R) Gemini C18 (150 x 4, 6 mm i.d., 5 mu m) column using acetonitrile and triethylamine buffer 0.1% (TEA) (40 : 60 v/v) as a mobile phase in an isocratic elution, pH 5.6 at a flow rate of 1 ml min(-1). TRIAC was detected at a wavelength of 220 nm. The injection volume was 20 mu l and the column temperature was maintained at 35 degrees C. The validation characteristics included accuracy, precision, specificity, linearity, recovery, and robustness. The standard curve was found to have a linear relationship (r(2) - 0.9996) over the analytical range of 5-100 mu g ml(-1) . The detection and quantitation limits were 1.3 and 3.8 mu g ml(-1), respectively. The recovery and loaded TRIAC in colloidal system delivery was nearly 100% and 98%, respectively. The method was successfully applied in polycaprolactone, polyhydroxybutyrate, and polymethylmethacrylate nanoparticles.
Resumo:
A simple method was developed for spectrophotometric determination of some nonsteroidal anti-inflammatory drugs (meloxicam, piroxicam and tenoxicam) based on the reduction of copper(II) in buffered solution (pH 7.0) and micellar medium containing 4,4'-dicarboxy-2,2'-buffered solution (pH 7.0) and micellar medium containing 4,4'-dicarboxy-2,2'-biquinoline acid. The-biquinoline acid. The absorbance values at 558 nm, characteristic of the formed Cu(I)/4,4'-dicarboxy-2,2'-biquinoline complexes, are linear with the concentrations (5.7-40 mmol L(-1), n = 5) of these oxicams (meloxicam r = 0.998; piroxicam and tenoxicam r = 0.999). The limit of detection values, in mmol L(-1), calculated for meloxicam (2.7), piroxicam (1.2) and tenoxicam (1.3) was obtained with 99% confidence level and the relative standard deviations for meloxicam (3.1%), piroxicam (5.1%) and tenoxicam (1.2%) were calculated using a 25 mmol L(-1) solution (n = 7). Mean recovery values for meloxicam, piroxicam and tenoxicam forms were 100 +/- 6.9, 98.6 +/- 3.6 and 99.4 +/- 2.5%, respectively. The conditional potential of Cu(II)/Cu(I) in complex medium of 7.5 mmol L(-1) BCA was determined to be 629 +/- 11 mV vs. NHE.
Resumo:
Single interface flow systems (SIFA) present some noteworthy advantages when compared to other flow systems, such as a simpler configuration, a more straightforward operation and control and an undemanding optimisation routine. Moreover, the plain reaction zone establishment, which relies strictly on the mutual inter-dispersion of the adjoining solutions, could be exploited to set up multiple sequential reaction schemes providing supplementary information regarding the species under determination. In this context, strategies for accuracy assessment could be favourably implemented. To this end, the sample could be processed by two quasi-independent analytical methods and the final result would be calculated after considering the two different methods. Intrinsically more precise and accurate results would be then gathered. In order to demonstrate the feasibility of the approach, a SIFA system with spectrophotometric detection was designed for the determination of lansoprazole in pharmaceutical formulations. Two reaction interfaces with two distinct pi-acceptors, chloranilic acid (CIA) and 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) were implemented. Linear working concentration ranges between 2.71 x 10(-4) to 8.12 x 10(-4) mol L(-1) and 2.17 x 10(-4) to 8.12 x 10(-4) mol L(-1) were obtained for DDQ and CIA methods, respectively. When compared with the results furnished by the reference procedure, the results showed relative deviations lower than 2.7%. Furthermore. the repeatability was good, with r.s.d. lower than 3.8% and 4.7% for DDQ and CIA methods, respectively. Determination rate was about 30 h(-1). (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Estrogens are a class of micro-pollutants found in water at low concentrations (in the ng L(-1) range), but often sufficient to exert estrogenic effects due to their high estrogenic potency. Disinfection of waters containing estrogens through oxidative processes has been shown to lead to the formation of disinfection byproducts, which may also be estrogenic. The present work investigates the formation of disinfection byproducts of 17 beta-estradiol (E2) and estrone (E1) in the treatment of water with ozone. Experiments have been carried out at two different concentrations of the estrogens in ground water (100 ng L(-1) and 100 mu g L(-1)) and at varying ozone dosages (0-30 mg L(-1)). Detection of the estrogens and their disinfection byproducts in the water samples has been performed by means of ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with a triple quadrupole (QqQ) and a quadrupole-time of flight (QqTOF) instrument. Both E2 and El have been found to form two main byproducts, with molecular mass (MM) 288 and 278 in the case of E2, and 286 and 276 in the case of El, following presumably the same reaction pathways. The E2 byproduct with MM 288 has been identified as 10epsilon-17beta-dihydroxy-1,4-estradieno-3-one (DEO), in agreement with previously published results. The molecular structures and the formation pathways of the other three newly identified byproducts have been suggested. These byproducts have been found to be formed at both high and low concentrations of the estrogens and to be persistent even after application of high ozone dosages. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This survey evaluated the presence of AFM(1) in human urine samples from a specific Brazilian population, as well as corn, peanut, and milk consumption measured by two types of food inquiry. Urine samples from donors who live in the city of Piracicaba, State of Sao Paulo, Brazil were analyzed to detect the presence of aflatoxin M(1) (AFM(1)). an aflatoxin B(1) metabolite, which may be used as aflatoxin B(1) exposure biomarker. The AFM(1) analysis was performed using immunoaffinity clean-up and detection by high-performance-liquid chromatography with fluorescence detector. A total of 69 samples were analyzed and 45 of them (65%) presented contaminations >= 1.8 pg ml(-1), which was the limit of quantification (LOQ). Seventy eight percent (n = 54) of the samples presented detectable concentrations of AFM(1) (>0.6 pg ml(-1)). The AFM(1) concentration among samples above LOQ ranged from 1.8 to 39.9 pg ml(-1). There were differences in food consumption profile among donors, although no association was found between food consumption and AFM(1) concentration in urine. The high frequency of positive samples suggests exposure of the populations studied to aflatoxins. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Cultivar, growing conditions and geographical origin are factors that influence the carotenoid composition in fruits. Because the loquat cultivars evaluated in this study, CentenAria, Mizauto, Mizuho, Mizumo and Nectar de Cristal, have not previously been investigated, the present work was carried out to determine and compare the carotenoid composition of these five loquat cultivars, by applying high-performance liquid chromatography connected to a photodiode array and mass spectrometry detectors (HPLC-PDA-MS/MS). Twenty-five carotenoids were separated on a C(30) column, and 23 of them were identified. All-trans-beta-carotene (19-55%), all-trans-beta-cryptoxanthin (18-28%), 5,6:5`,6`-diepoxy-beta-cryptoxantilin (9-18%) and 5,6-epoxy-beta-cryptoxanthin (7-10%) were the main carotenoids. The total carotenoid content ranged from 196 mu g/100 g (cv. Nectar de Cristal) to 3020 mu g/100 g (CV. Mizumo). The carotenoid profile of cv. Nectar de Cristal was different from the other cultivars, which was in agreement with its cream pulp colour, in contrast to the other four cultivars with orange pulp colour. Cultivars Mizauto, Mizuho, Mizumo and CentenAria showed provitamin A values between 89 and 162 mu g RAE/100 g, and can be considered good source of this provitamin. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Paraquat is a broad-spectrum contact herbicide that has been encountered worldwide in several cases of accidental, homicidal, and suicidal poisonings. The pulmonary toxicity of this compound is related to the depletion of NADPH in the pneumocytes, which is continuously consumed by the reduction/oxidation of paraquat and reductase enzyme systems in the presence of O(2) (redox cycling). Based on this mechanism, an enzymatic-spectrophotometric method was developed for the determination of paraquat in urine samples. The velocity of NADPH consumption was monitored at 340 nm, every 10 s during 15 min. The velocity of NADPH oxidation correlated with the paraquat levels found in samples. The enzymatic-spectrophotometric method showed to be sensitive, making possible the detection of paraquat in urine samples at concentrations as low as 0.05 mg/L.
Resumo:
A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08-5.70 mu g mL(-1) (r = 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 mu g mL(-1), respectively.
Resumo:
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 mu m I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 mu g mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 mu g mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
In this study, a simple, rapid and sensitive HPLC method with UV detection is described for determination of metformin in plasma samples from bioequivalence assays. Sample preparation was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed on a reversed-phase phenyl column at 40 degrees C. Mobile phase consisted of a mixture of phosphate buffer and acetonitrile at flow rate of 1.0 ml/min. Wavelength was set at 236 nm. The method was applied to a bioequivalence study of two drug products containing metformin, and allowed determination of metformin at low concentrations with a higher throughput than previously described methods. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Pancuronium bromide is used with general anesthesia in surgery for muscle relaxation and as an aid to intubation. A high performance liquid chromatographic method was fully validated for the quantitative determination of pancuronium bromide in pharmaceutical injectable solutions. The analytical method was performed on an amino column (Luna 150mm4.6mm, 5m). The mobile phase was composed of acetonitrile:water containing 50mmol L-1 of 1-octane sulfonic acid sodium salt (20:80v/v) with a flow rate of 1.0mL min-1 and ultraviolet (UV) detection at 210nm. The proposed analytical method was compared with that described in the British Pharmacopoeia.
Resumo:
Vecuronium bromide is a neuromuscular blocking agent used for anesthesia to induce skeletal muscle relaxation. HPLC and CZE analytical methods were developed and validated for the quantitative determination of vecuronium bromide. The HPLC method was achieved on an amino column (Luna 150 x 4.6 mm, 5 mu m) using UV detection at 205 nm. The mobile phase was composed of acetonitrile:water containing 25.0 mmol L(-1) of sodium phosphate monobasic (50:50 v/v), pH 4.6 and flow rate of 1.0 mL min(-1). The CZE method was achieved on an uncoated fused-silica capillary (40.0 cm total length, 31.5 cm effective length and 50 mu m i.d.) using indirect UV detection at 230 nm. The electrolyte comprised 1.0 mmol L(-1) of quinine sulfate dihydrate at pH 3.3 and 8.0% of acetonitrile. The results were used to compare both techniques. No significant differences were observed (p > 0.05).
Resumo:
The aim of this study was to validate an agar diffusion method through the parameters linearity, precision and accuracy, to quantify apramycin in soluble powder. The calibration curve of apramycin was constructed by plotting log of concentrations (mu g ml(-1)) versus zone diameter (mm) and shows good linearity in the range of 1.0-4.0 mu g.ml(-1). The precision of the assay was determined by assaying samples at the same day (repeatability - R.S.D. = 2.00%) and on different days (intermediate precision - R.S.D. = 5.06%) and indicate good precision. The accuracy expresses the agreement between the accepted value and the value found. The mean recovery was found to be 100.49 % for apramycin soluble powder. The results indicated that the microbiological assay proposed in this work hold linearity, precision and accuracy being an acceptable alternative method for routine quality control of apramycin in the pharmaceutical dosage form studied.