236 resultados para Heart -- Surgery
Resumo:
Objectives To analyze the association between resting heart rate and blood pressure in male children and adolescents and to identify if this association is mediated by important confounders. Study design Cross-sectional study carried out with 356 male children and adolescents from 8 to 18 years old. Resting heart rate was measured by a portable heart rate monitor according to recommendations and stratified into quartiles. Blood pressure was measured with an electronic device previously validated for pediatric populations. Body fatness was estimated by a dual-energy x-ray absorptiometry. Results Obese subjects had values of resting heart rate 7.8% higher than nonobese (P = .001). Hypertensive children and adolescents also had elevated values of resting heart rate (P = .001). When the sample was stratified in nonobese and obese, the higher quartile of resting heart rate was associated with hypertension in both groups of children and adolescents. Conclusions This study confirms the existence of a relationship between elevated resting heart rate and increased blood pressure in a pediatric population, independent of adiposity, ethnicity and age. (J Pediatr 2011; 158:634-7).
Resumo:
To analyse the sensitivity and specificity of clinical indicators of ineffective airway clearance in children with congenital heart disease and to identify the indicators that have high predictive power. The precise establishment of nursing diagnoses has been found to be one of the factors contributing to higher quality of care and cost reduction in healthcare institutions. The use of indicators to diagnose ineffective airway clearance could improve care of children with congenital heart disease. Longitudinal study. Participants consisted of 45 children, <= 1 year of age, with congenital heart disease, who had not had definitive or palliative surgical correction. Six assessments were made at 2-day intervals. Each clinical indicator was defined based on previously established operational criteria. Sensitivity, specificity and positive and negative predictive values of each indicator were calculated based on a model for the longitudinal data. A nursing diagnosis of ineffective airway clearance was made in 31% of patients on the first assessment, rising to 71% on the last assessment, for a 40% increase. Sensitivity was highest for Changes in Respiratory Rates/Rhythms (0.99), followed by Adventitious Breath Sounds (0.97), Sputum Production (0.85) and Restlessness (0.53). Specificity was higher for Sputum Production (0.92), followed by Restlessness (0.73), Adventitious Breath Sounds (0.70) and Changes in Respiratory Rates/Rhythms (0.17). The best positive predictive values occurred for Sputum Production (0.93) and Adventitious Breath Sounds (0.80). Adventitious Breath Sounds followed by Sputum Production were the indicators that had the best overall sensitivity and specificity as well as the highest positive predictive values. The use of simple indicators in nursing diagnoses can improve identification of ineffective airway clearance in children with congenital heart disease, thus leading to early treatment of the problem and better care for these children.
Resumo:
Freeze-drying of biological tissues allows for dry storage and gamma ray sterilization, which may improve their use as a medical prosthesis. The objective of this study was to evaluate the rehydration characteristics and hydrodynamic performance of prosthetic valves before and after lyophilization. Two size 23 bovine pericardium aortic valve prostheses from different manufacturers were evaluated in a Shelhigh (Union, NJ, USA) pulse duplicator (80 ppm, 5 L/min) before and after lyophilization. Flow and transvalvular pressure gradient were registered in vitro and in vivo, and images of opening and closing of the prosthesis were obtained in the pulse duplicator in a digital camera. Rehydration was evaluated by comparison of dry valve weight with valve weight after 15 min, and 1, 24, 48, and 72 h in saline solution, inside the pulse duplicator. In vivo performance was assessed by surgical implantation in Santa Ines young male sheep in the pulmonary position after 30 min rehydration with 0.9% saline. Transvalvular pressure gradient and flow measurements were obtained immediately after implantation and 3 months after surgery when valves were explanted. Captured images showed a change in the profile opening and closing of valve prosthesis after lyophilization. The gradient measured (in vitro) in two valves was 17.08 +/- 0.57 and 18.76 +/- 0.70 mm Hg before lyophilization, and 34.24 +/- 0.59 and 30.40 +/- 0.97 mm Hg after lyophilization. Rehydration of both lyophilized valves was approximately 82%. Drying changed the profile of the opening and closing of valve prostheses, and increased on average by 83% the gradient in vitro tests. The result of the in vivo tests suggests maintaining pressure levels of the animal with the lyophilized prostheses within acceptable levels.
Resumo:
The `biomimetic` approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD`s inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber, variable throttle and reservoir, connected by silicone tubings. The reservoir sat on an elevated platform, allowing adjustment of ventricular preload between 0 and 11 mmHg. To allow for sterile gaseous exchange between the circuit interior and exterior, a 0.2 mu m filter was placed at the reservoir. Pressure and flow were registered downstream of the TE valve. The circuit was filled with culture medium and fitted in a standard 5% CO(2) incubator set at 37 degrees C. Pressure and flow waveforms were similar to those obtained under physiological conditions for the pulmonary circulation. The `cardiomimetic` approach presented here represents a new perspective to conventional biomimetic approaches in TE, with potential advantages. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
We investigate whether arterial baroreceptors mediate the training-induced blood pressure fall and resting bradycardia in hypertensive (SHR) and normotensive rats (WKY). Male SHR and WKY rats, submitted to sino-aortic denervation (SAD) or sham surgery (SHAM group), were allocated to training (T; 55% of maximal exercise capacity) or sedentary (S) protocols for 3 months. Rats were instrumented with arterial and venous catheters for haemodynamic measurements at rest (power spectral analysis) and baroreceptor testing. Kidney and skeletal muscles were processed for morphometric analysis of arterioles. Elevated mean arterial pressure (MAP) and heart rate (HR) in SHAM SHRS were accompanied by increased sympathetic variability and arteriolar wall/lumen ratio [+3.4-fold on low-frequency (LF) power and +70%, respectively, versus WKYS, P < 0.05]. Training caused significant HR (similar to 9% in WKY and SHR) and MAP reductions (-8% in the SHR), simultaneously with improvement of baroreceptor reflex control of HR (SHR and WKY), LF reduction (with a positive correlation between LF power and MAP levels in the SHR) and normalization of wall/lumen ratio of the skeletal muscle arterioles (SHR only). In contrast, SAD increased pressure variability in both strains of rats, causing reductions in MAP (-13%) and arteriolar wall/lumen ratio (-35%) only in the SHRS. Training effects were completely blocked by SAD in both strains; in addition, after SAD the resting MAP and HR and the wall/lumen ratio of skeletal muscle arterioles were higher in SHRT versus SHRS and similar to those of SHAM SHRS. The lack of training-induced effects in the chronic absence of baroreceptor inputs strongly suggests that baroreceptor signalling plays a decisive role in driving beneficial training-induced cardiovascular adjustments.
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
Background: Beyond the first year after a heart transplant (HT) procedure, patients often develop dyslipidemias, which may be implicated in the genesis of transplant coronary heart disease. High-density lipoprotein (HDL) has a several anti-atherogenic properties, but the status of HDL in HT patients is still controversial. Nonetheless, determination of HDL cholesterol concentration is not sufficient for evaluation of the overall HDL protective role. In this study, a fundamental functional property of HDL, the ability to simultaneously receive the major lipid classes, was tested in HT patients. Methods: Twenty HT patients and 20 healthy normolipidemic subjects paired for gender, age and body mass index were studied. Blood samples were collected after 12-hour fasting for determination of plasma lipids, glucose, paraxonase I (PON 1) activity, HDL diameter and transfer of labeled lipids from an artificial nanoemulsion to HDL. Results: Plasma triglycerides (159 +/- 63 vs 94 +/- 35 mg/dl) and glucose (104 +/- 20 vs 86 +/- 10 mg/dl) were greater in HT patients than in control subjects. HDL cholesterol was lower and HDL diameter was smaller in the HT group (HDL cholesterol: 44 +/- 11 vs 55 +/- 15 mg/dl; HDL diameter: 8.8 +/- 0.6 vs 9.0 +/- 1.2 nm). PON 1 activity did not differ (87 +/- 47 vs 75 +/- 37 nmol/min/ml). The transfer rates of free cholesterol and cholesteryl esters were diminished in HT patients (HT: 8.4 +/- 1.2% and 3.8 +/- 0.6%; controls: 9.7 +/- 1.9% and 4.7 +/- 1.2%, respectively). Conclusions: The transfer of free cholesterol and cholesteryl esters to HDL is diminished in HT patients; disturbance in the ability of HDL to receive lipids may affect the anti-atherogenic properties of the lipoprotein. J Heart Lung Transplant 2009;28:1075-80. Copyright (C) 2009 by the International Society for Heart and Lung Transplantation.
Resumo:
Pulmonary Vascular Research Institute
Resumo:
Background and Purpose. There has been a lot of debate about the use of predicted oxygen consumption to calculate pulmonary vascular resistance using the Fick principle. We therefore comparatively analyzed predicted oxygen consumption in infants and children in specific age groups, using different methods (formulas), as an attempt to better understand the usefulness and limitations of predictions. Methods and Results. Four models (LaFarge & Miettinen, Bergstra et al., Lindahl, and Lundell et al.) were used to predict oxygen consumption in 200 acyanotic patients with congenital cardiac defects aged 0-2.0, > 2.0-4.0, > 4.0-6.0, and > 6.0-8.75 years (median 2.04 years). Significant differences were observed between the age groups (P < .001) and between the methods (P < .001), not related to diagnoses. Differences between methods were more impressive in the first age group (P < .01). In patients aged 0-2.0 years, the lowest values of oxygen consumption (corresponding to the highest estimates of pulmonary vascular resistance) were obtained with the method of Lindahl; above this age, any method except that of Lundell et al. Conclusions. Although measuring oxygen consumption is always preferable, a rational use of predictions, using different methods, may be of help in situations where measurements are definitely not possible.
Resumo:
Objective: To investigate the influence of maternal glycemia on fetal heart rate (FHR) parameters analyzed by computerized cardiotocography in fetuses of diabetic mothers in the third trimester. Study design: Thirty-nine pregnant women with pregestational diabetes mellitus were studied prospectively. The inclusion criteria were a diagnosis of pregestational diabetes, singleton pregnancy between 36 and 40 weeks, and absence of fetal abnormalities. Computerized cardiotocography (System 8002) was performed over a period of 60 min and capillary glycemia was measured immediately before and 30 and 60 min after the beginning of the exam. The evaluations were done 2 h after lunch. Results: Nineteen patients (48.7%) presented mean glycemia >= 120 mg/dL The mean basal FHR was 136.7 +/- 10.0 bpm in the group with glycemia <120 mg/dL and 144.8 +/- 9.4 bpm in the group with glycemia >= 120 mg/dL (p = 0.013, Student`s t test). There was a significant positive correlation (Pearson`s test, p = 0.0001, r = 0.57) between basal FHR and mean glycemia. A significant negative correlation was observed between short-term variation and mean glycemia (Pearson`s test, p = 0.003, r = -0.47). No significant differences were observed between the other indices evaluated by computerized cardiotocography and glycemia. Conclusions: Maternal hyperglycemia at the time of cardiotocography is associated with elevated FHR. It seems to be important to understand how FHR parameters are influenced by maternal glycemic status at the time of fetal assessment in pregnancies complicated by diabetes. (C) 2009 Published by Elsevier Ireland Ltd.
Resumo:
The aim of this study was to evaluate (1) the prevalence of periodic leg movements during sleep (PLMs) in a consecutive sample of congestive heart failure (CHF) outpatients; (2) the presence of correlation between PLMs, subjective daytime sleepiness, and sleep architecture; and (3) the heart rate response to PLMs in CHF. Seventy-nine [50 men, age 59 +/- 11 years, body mass index (BMI) 26 +/- 5 kg/m(2)] consecutive adult stable outpatients with CHF [left ventricular ejection fraction (LVEF) 36 +/- 6%] were prospectively evaluated. The patients underwent assessment of echocardiography, sleepiness (Epworth Scale), and overnight in-lab polysomnography. Fifteen patients (19%) had PLM index > 5. These subjects were similar in sex distribution, BMI, subjective somnolence, LVEF, and apnea-hypopnea index (AHI), but were significantly older than subjects without PLMs. Sleep architecture was similar in subjects with and without PLMs. There was a small but significant elevation of heart rate after PLMs (80.1 +/- 9.4 vs. 81.5 +/- 9.2; p < 0.001). The cardiac acceleration was also present in absence of electroencephalogram activation. The prevalence of PLMs in consecutive sample of adult CHF outpatients was 19%. There were no differences in subjective daytime sleepiness, sleep architecture, AHI, and severity of CHF in subjects with and without PLMs. PLMs caused a small but statistically significant cardiac acceleration.
Resumo:
Background Metabolic syndrome refers to risk factors for cardiovascular disease. Hyperglycemia is a critical component contributing to the predictive power of the syndrome. This study aimed to evaluate the results from the laparoscopic interposition of an ileum segment into the proximal jejunum for the treatment of metabolic syndrome in patients with type 2 diabetes mellitus and a body mass index (BMI) lower than 35. Methods Laparoscopic procedures were performed for 60 patients (24 women and 36 men) with a mean age of 51.7 +/- 6.4 years (range, 27-66 years) and a mean BMI of 30.1 +/- 2.7 (range, 23.6-34.4). All the patients had a diagnosis of type 2 diabetes mellitus (T2DM) given at least 3 years previously and evidence of stable treatment using oral hypoglycemic agents, insulin, or both for at least 12 months. The mean duration of type 2 diabetes mellitus was 9.6 +/- 4.6 years (range, 3-22 years). Metabolic syndrome was diagnosed for all 60 patients. Arterial hypertension was diagnosed for 70% of the patients (mean number of drugs, 1.6) and hypertriglyceridemia for 70%. High-density lipoprotein was altered in 51.7% of the patients and the abdominal circumference in 68.3%. Two techniques were performed: ileal interposition (II) into the proximal jejunum and sleeve gastrectomy (II-SG) or ileal interposition associated with a diverted sleeve gastrectomy (II-DSG). Results The II-SG procedure was performed for 32 patients and the II-DSG procedure for 28 patients. The mean postoperative follow-up period was 7.4 months (range, 3-19 months). The mean BMI was 23.8 +/- 4.1 kg/m(2), and 52 patients (86.7%) achieved adequate glycemic control. Hypertriglyceridemia was normalized for 81.7% of the patients. An high-density lipoprotein level higher than 40 for the men and higher than 50 for the women was achieved by 90.3% of the patients. The abdominal circumference reached was less than 102 cm for the men and 88 cm for the women. Arterial hypertension was controlled in 90.5% of the patients. For the control of metabolic syndrome, II-DSG was the more effective procedure. Conclusions Laparoscopic II-SG and II-DSG seem to be promising procedures for the control of the metabolic syndrome and type 2 diabetes mellitus. A longer follow-up period is needed.
Resumo:
Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).
Resumo:
Although a new protocol of dobutamine stress echocardiography with the early injection of atropine (EA-DSE) has been demonstrated to be useful in reducing adverse effects and increasing the number of effective tests and to have similar accuracy for detecting coronary artery disease (CAD) compared with conventional protocols, no data exist regarding its ability to predict long-term events. The aim of this study was to determine the prognostic value of EA-DSE and the effects of the long-term use of beta blockers on it. A retrospective evaluation of 844 patients who underwent EA-DSE for known or suspected CAD was performed; 309 (37%) were receiving beta blockers. During a median follow-up period of 24 months, 102 events (12%) occurred. On univariate analysis, predictors of events were the ejection fraction (p <0.001), male gender (p <0.001), previous myocardial infarction (p <0.001), angiotensin-converting enzyme inhibitor therapy (p = 0.021), calcium channel blocker therapy (p = 0.034), and abnormal results on EA-DSE (p <0.001). On multivariate analysis, the independent predictors of events were male gender (relative risk [RR] 1.78, 95% confidence interval [CI] 1.13 to 2.81, p = 0.013) and abnormal results on EA-DSE (RR 4.45, 95% CI 2.84 to 7.01, p <0.0001). Normal results on EA-DSE with P blockers were associated with a nonsignificant higher incidence of events than normal results on EA-DSE without beta blockers (RR 1.29, 95% CI 0.58 to 2.87, p = 0.54). Abnormal results on EA-DSE with beta blockers had an RR of 4.97 (95% CI 2.79 to 8.87, p <0.001) compared with normal results, while abnormal results on EA-DSE without beta blockers had an RR of 5.96 (95% CI 3.41 to 10.44, p <0.001) for events, with no difference between groups (p = 0.36). In conclusion, the detection of fixed or inducible wall motion abnormalities during EA-DSE was an independent predictor of long-term events in patients with known or suspected CAD. The prognostic value of EA-DSE was not affected by the long-term use of beta blockers. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:1291-1295)
Resumo:
Background-Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling data from randomized controlled trials increases the statistical power and allows better assessment of the treatment effect in high-risk subgroups. Methods and Results-We performed a pooled analysis of 3051 patients in 4 randomized trials evaluating the relative safety and efficacy of PCI with stenting and CABG at 5 years for the treatment of multivessel coronary artery disease. The primary end point was the composite end point of death, stroke, or myocardial infarction. The secondary end point was the occurrence of major adverse cardiac and cerebrovascular accidents, death, stroke, myocardial infarction, and repeat revascularization. We tested for heterogeneities in treatment effect in patient subgroups. At 5 years, the cumulative incidence of death, myocardial infarction, and stroke was similar in patients randomized to PCI with stenting versus CABG (16.7% versus 16.9%, respectively; hazard ratio, 1.04, 95% confidence interval, 0.86 to 1.27; P = 0.69). Repeat revascularization, however, occurred significantly more frequently after PCI than CABG (29.0% versus 7.9%, respectively; hazard ratio, 0.23; 95% confidence interval, 0.18 to 0.29; P<0.001). Major adverse cardiac and cerebrovascular events were significantly higher in the PCI than the CABG group (39.2% versus 23.0%, respectively; hazard ratio, 0.53; 95% confidence interval, 0.45 to 0.61; P<0.001). No heterogeneity of treatment effect was found in the subgroups, including diabetic patients and those presenting with 3-vessel disease. Conclusions-In this pooled analysis of 4 randomized trials, PCI with stenting was associated with a long-term safety profile similar to that of CABG. However, as a result of persistently lower repeat revascularization rates in the CABG patients, overall major adverse cardiac and cerebrovascular event rates were significantly lower in the CABG group at 5 years.