156 resultados para Furfuryl alcohol resin


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies that have investigated ascorbic acid (AA) concentrations in cord blood have pointed to significant associations with maternal blood AA concentrations. smoking, age, diet, type of delivery, duration of gestation, fetal distress and birth weight. The aim of the present study was to determine the relationship between cord blood AA concentrations in newborns and maternal characteristics. A total of 117 Brazilian healthy parturients were included in this cross-sectional study. The concentrations of AA in blood were determined by the HPLC method. Data concerning socio-economic, demographic, obstetric, nutritional and health characteristics of the parturients, including alcohol consumption and smoking habit, were assessed by a standardised questionnaire. A FFQ was used to investigate the intake of foods rich in vitamin C. Cord blood AA concentration was significantly correlated with per capita income (r 0.26; P=0.005), maternal blood AA concentration (r 0.48; P<0.001) and maternal vitamin C-rich food intake score (r 0.36; P<0.001). The linear regression model including maternal AA concentration, alcohol consumption, smoking, parity, vitamin C-rich food intake score and per capita income explained 31.13% of the variation in cord blood AA concentrations in newborns. We recommend further experimental studies to assess the effects of ethanol on placental AA uptake, and epidemiological cohort studies to evaluate in detail the influence of maternal alcohol consumption on cord blood AA concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elevated levels of impulsivity and increased risk taking are thought to be core features of both bipolar disorder (BD) and addictive disorders. Given the high rates of comorbid alcohol abuse in BD, alcohol addiction may exacerbate impulsive behavior and risk-taking propensity in BD. Here we examine multiple dimensions of impulsivity and risk taking, using cognitive tasks and self-report measures, in BD patients with and without a history of alcohol abuse. Thirty-one BD subjects with a prior history of alcohol abuse or dependence (BD-A), 24 BD subjects with no history of alcohol abuse/dependence (BD-N), and 25 healthy control subjects (HC) were assessed with the Barratt Impulsiveness Scale (BIS) and the computerized Balloon Analogue Risk Task (BART). Both BD groups scored significantly higher than controls on the BIS. In contrast, only the BD-A group showed impaired performance on the BART. BD-A subjects popped significantly more balloons than the BD-N and HC groups. In addition, subjects in the BD-A group failed to adjust their performance after popping balloons. Severity of mood symptomatology was not associated with performance on either task. The current study supports a primary role of prior alcohol abuse in risk-taking propensity among patients with bipolar disorder. In addition, findings suggest that impulsivity and risky behavior, as operationalized by self-report and experimental cognitive probes, respectively, are separable constructs that tap distinct aspects of the bipolar phenotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate sociodemographic correlates associated with transitions from alcohol use to disorders and remission in a Brazilian population. Methods: Data are from a probabilistic, multi-stage clustered sample of adult household residents in the Sao Paulo Metropolitan Area. Alcohol use, regular use (at least 12 drinks/year), DSM-IV abuse and dependence and remission from alcohol use disorders (AUDs) were assessed with the World Mental Health version of the Composite International Diagnostic Interview. Age of onset (AOO) distributions of the cumulative lifetime probability of each alcohol use stage were prepared with data obtained from 5037 subjects. Correlates of transitions were obtained from a subsample of 2942 respondents, whose time-dependent sociodemographic data were available. Results: Lifetime prevalences were 85.8% for alcohol use, 56.2% for regular use, 10.6% for abuse and 3.6% for dependence; 73.4 and 58.8% of respondents with lifetime abuse and dependence, respectively, had remitted. The number of sociodemographic correlates decreased from alcohol use to disorders. All transitions across alcohol use stages up to abuse were consistently associated with male gender, younger cohorts and lower education. Importantly, low education was a correlate for developing AUD and not remitting from dependence. Early AOO of first alcohol use was associated with the transition of regular use to abuse. Conclusion: The present study demonstrates that specific correlates differently contribute throughout alcohol use trajectory in a Brazilian population. It also reinforces the need of preventive programs focused on early initiation of alcohol use and high-risk individuals, in order to minimize the progression to dependence and improve remission from AUD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there is no consensus about the use of glucose and thiamine for the treatment of acute ethanol intoxication, this is a routine practice in many countries. Our objective was to determine the efficacy of this treatment and the changes it causes in the antioxidant status of the liver. Male Wistar rats were intoxicated with an ethanol dose of 5 g/kg and divided into three groups: ethanol (EtOH; untreated), EtOH+G (treated with glucose), and EtOH+B1 (treated with thiamine). Blood and urinary ethanol as well as hepatic malondialdehyde, reduced glutathione and vitamin E were determined in all animals. Blood alcohol levels did not differ between groups, although urinary excretion was about four times higher in the group treated with thiamine (EtOH+B1). The malondialdehyde, reduced glutathione and vitamin E values used here as parameters of the antioxidant system of the liver showed improvement for the thiamine-treated group (EtOH+B1). Treatment with glucose or thiamine was ineffective in reducing blood alcohol levels in rats with acute ethanol intoxication. However, the beneficial effect of thiamine as an antioxidant for ethanol metabolism was demonstrated. Further investigations are necessary to clarify the urinary excretion of ethanol reported here for the first time and the possibility of using thiamine as an antioxidant in situations of chronic alcohol use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, alcohol consumption has been considered an important public health problem. Ethanol, the alcohol used in beverages, is a drug that affects the central nervous system (CNS) and impairs driving skills and co-ordination, increasing risk of deaths and injuries derived from crashes and road accidents. Consumption of alcoholic beverages is implicated with premature deaths, injuries and damages caused by motor vehicle crashes, which result in high costs to government and society. Considering that alcohol consumption is the main responsible factor for deaths and disabilities in young people, the aim of this work was to evaluate the prevalence of blood alcohol in offenders and/or fatal and non-fatal victims of traffic occurrences in the region of Ribeirao Preto, Sao Paulo State, from 2005 to 2007. The results revealed that in 2134 cases investigated, blood alcohol positivity was generally found in young adults, 25-45 years old and male. The study showed the high risk of drinking and driving and the importance in establishing actions of prevention and intervention to promote the reduction in the number of traffic occurrences related to consumption of alcoholic beverages. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on the views of Primary Health Care (PHC) providers in Southeast Brazil on the use of alcohol and other drugs which reflect stigma, moralization, or negative judgment. Six hundred nine PHC professionals from the Brazilian states of Sao Paulo and Minas Gerais took part in the study. The majority (86.5%) of these professionals were female. Attitudes toward the use of alcohol and other drugs were evaluated in comparison to Hansen`s disease, obesity, depression, schizophrenia. HIV/AIDS, and tobacco use. The use of tobacco, marijuana/cocaine, and alcohol were the most negatively judged behaviors (p < 0.05). Nursing assistants and community health care workers demonstrated the severest judgment of alcohol use. In addition, marijuana/cocaine addicts and alcoholics suffered the highest rate of rejection by professionals. The hypothesis that the use of alcohol and other drugs is a behavior stigmatized by health professionals being confirmed, it is important to develop strategies for changing provider attitudes in order to provide a higher quality of service to these patients. This study is important as a first study among PHC professionals about social stigma of alcohol and other drugs users. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To estimate physical violence between intimate partners and to examine the association between violence and sociodemographic variables, use of alcohol, and other related factors. Method. This epidemiologic survey included a stratified probabilistic sample representative of the population from the city of Sao Paulo in economic and educational terms. The Gender, Alcohol and Culture: An International Study (GENACIS) questionnaire was employed. The sampling unit was the home, where all individuals older than 18 years were candidates for interview. The final sample included 1 631 people. Statistical analysis employed the Rao Scott test and logistic regression. Results. The response rate was 74.5%. Most participants were female (58.8%), younger than 40 years of age (52%), or had 5 to 12 years of schooling. Of the overall group, 5.4% reported having been victims of physical violence by an intimate partner and 5.4% declared having been aggressors of intimate partners in the past 2 years. Most men declared that none of those involved had ingested alcohol at the moment of aggression. Most women reported that nobody or only the man had drunk. Being a victim or an aggressor was associated with younger age and having a heavy-drinking partner. Women suffered more serious aggression, requiring medical care, and expressed more anger and disgust at aggression than men. Conclusions. The results underscore the importance of the association between alcohol use and risk of aggression between intimate partners, and may contribute to the design of public policies aimed to control this situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate in vitro light activation of the nano-filled resin composite Vita shade A1 and A3 with a halogen lamp (QTH) and argon ion laser by Knoop microhardness profile. Materials and methods: Specimens of nanofilled composite resin (Z350-3 M-ESPE) Vita shade A1 and A3 were prepared with a single increment inserted in 2.0-mm-thick and 3-mm diameter disc-shaped Teflon mold. The light activation was performed with QTH for 20 s (with an intensity of approximately 1,000 mW/cm(2) and 700 mW/cm(2)) and argon ion laser for 10 s (with a power of 150 mW and 200 mW). Knoop microhardness test was performed after 24 h and 6 months. The specimens were divided into the 16 experimental groups (n = 10), according to the factors under study: photoactivation form, resin shade, and storage time. Knoop microhardness data was analyzed by a factorial ANOVA and TukeyA ` s tests at the 0.05 level of significance. Results: Argon ion laser was not able to photo-activate the darker shade of the nanofilled resin composite evaluated but when used with 200 mW it can be as effective as QTH to photo-activate the lighter shade with only 50% of the time exposure. After 6 months storage, an increase in the means of Knoop microhardness values were observed. Conclusions: Light-activation significantly influenced the Knoop microhardness values for the darker nanofilled resin composite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. Study Design: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S3 Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. Results: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. ""Stretch mark""-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. Conclusion: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study. Lasers Surg. Med. 42:662-670, 2010. (C) 2010 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study aimed to determine whether the micro-hardness of a composite resin is modified by the light units or by the thickness of the increment. Composite resin disks were divided into 15 groups (n = 5), according to the factors under study: composite resin thickness (0 mm, 1 mm, 2 mm , 3 mm and 4 mm) and light units. The light activation was performed with halogen light (HL) (40 s, 500 mW/cm(2)), argon ion laser (AL) (30 s, 600 mW/cm(2)) or light-emitting diode (LED) (30 s, 400 mW/cm(2)). Vickers micro-hardness tests were performed after 1 week and were carried out on the top surface (0 mm-control) and at different depths of the samples. Analysis of variance (ANOVA) and Tukey tests (P a parts per thousand currency signaEuro parts per thousand 0.05) revealed no statistically significant difference among the light units for the groups of 0 mm and 1 mm thickness. At 2 mm depth, the AL was not statistically different from the HL, but the latter showed higher micro-hardness values than the LED. In groups with 3 mm and 4 mm thickness, the HL also showed higher micro-hardness values than the groups activated by the AL and the LED. Only the HL presented satisfactory polymerization with 3 mm of thickness. With a 4 mm increment no light unit was able to promote satisfactory polymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adhesive performance on deproteinized dentin of different self-adhesive resin cements was evaluated through microtensile bond strength (mu TBS) analysis and scanning electron microscopy (SEM). Occlusal dentin of human molars were distributed into different groups, according to the categories: adhesive cementation with two-step bonding systems-control Groups (Adper Single Bond 2 + RelyX ARC/3M ESPE; One Step Plus + Duolink/Bisco; Excite + Variolink I/Ivoclar Vivadent) and self-adhesive cementation-experimental groups (Rely X Unicem/3M ESPE; Biscem/Bisco; MultiLink Sprint/Ivoclar Vivadent). Each group was subdivided according to the dentin approach to: alpha, maintenance of collagen fibers and beta, deproteinization. The mean values were obtained, and submitted to ANOVA and Tukey test. Statistical differences were obtained to the RelyX Unicem groups (alpha = 13.59 MPa; beta = 30.19 MPa). All the BIS Group specimens failed before the mechanical tests. Dentinal deproteinization provided an improved bond performance for the self-adhesive cement Rely X Unicem, and had no negative effect on the other cementing systems studied. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 98B: 387-394, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To examine the effect of prolonged application time on the early and 3-year resin-dentin microtensile bond strength. Methods. Water/ethanol (Single Bond [SB]) and acetone-based systems (One Step [OS]) were employed. A flat superficial dentin surface was exposed in third human molars by wet abrasion. The adhesives were applied to a delimited area of 52 mm(2) on wet surfaces, for 40, 90, 150 and 300s. Four teeth were assigned for each experimental condition. Composite build-ups were constructed incrementally After water storage at 37 degrees C for 24 h, teeth were sectioned to obtain sticks with cross-sectional areas of 0.8 mm(2) to be tested in tension (0.5 mm/min) either immediately (IM) or after 3 years (3Y) of water storage. The microtensile bond strength (mu TBS) values were analyzed by two way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results. The 90- and 150-s groups achieved the highest IM mu TBS for OS (p < 0.01). For SB, the highest IM mu TBS values were observed after 300-s application (p < 0.01). Significant decreases in mu TBS were observed for OS in the 40- and 90-s groups after 3Y, except for the 150-s group. With regard to SB, after 3Y significant drops in mu TBS values were observed for the 40- and 150-s groups, except for the 300-s group. Significance. Prolonged application times can increase the immediate LTBS of two-step etch-and-rinse adhesive systems and make the adhesive layer more stable over time. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.