83 resultados para CAMERA TRAPS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation dose calculations in nuclear medicine depend on quantification of activity via planar and/or tomographic imaging methods. However, both methods have inherent limitations, and the accuracy of activity estimates varies with object size, background levels, and other variables. The goal of this study was to evaluate the limitations of quantitative imaging with planar and single photon emission computed tomography (SPECT) approaches, with a focus on activity quantification for use in calculating absorbed dose estimates for normal organs and tumors. To do this we studied a series of phantoms of varying complexity of geometry, with three radionuclides whose decay schemes varied from simple to complex. Four aqueous concentrations of (99m)Tc, (131)I, and (111)In (74, 185, 370, and 740 kBq mL(-1)) were placed in spheres of four different sizes in a water-filled phantom, with three different levels of activity in the surrounding water. Planar and SPECT images of the phantoms were obtained on a modern SPECT/computed tomography (CT) system. These radionuclides and concentration/background studies were repeated using a cardiac phantom and a modified torso phantom with liver and ""tumor"" regions containing the radionuclide concentrations and with the same varying background levels. Planar quantification was performed using the geometric mean approach, with attenuation correction (AC), and with and without scatter corrections (SC and NSC). SPECT images were reconstructed using attenuation maps (AM) for AC; scatter windows were used to perform SC during image reconstruction. For spherical sources with corrected data, good accuracy was observed (generally within +/- 10% of known values) for the largest sphere (11.5 mL) and for both planar and SPECT methods with (99m)Tc and (131)I, but were poorest and deviated from known values for smaller objects, most notably for (111)In. SPECT quantification was affected by the partial volume effect in smaller objects and generally showed larger errors than the planar results in these cases for all radionuclides. For the cardiac phantom, results were the most accurate of all of the experiments for all radionuclides. Background subtraction was an important factor influencing these results. The contribution of scattered photons was important in quantification with (131)I; if scatter was not accounted for, activity tended to be overestimated using planar quantification methods. For the torso phantom experiments, results show a clear underestimation of activity when compared to previous experiment with spherical sources for all radionuclides. Despite some variations that were observed as the level of background increased, the SPECT results were more consistent across different activity concentrations. Planar or SPECT quantification on state-of-the-art gamma cameras with appropriate quantitative processing can provide accuracies of better than 10% for large objects and modest target-to-background concentrations; however when smaller objects are used, in the presence of higher background, and for nuclides with more complex decay schemes, SPECT quantification methods generally produce better results. Health Phys. 99(5):688-701; 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents the results of Raman spectroscopy applied to the classification of arterial tissue based on a simplified model using basal morphological and biochemical information extracted from the Raman spectra of arteries. The Raman spectrograph uses an 830-nm diode laser, imaging spectrograph, and a CCD camera. A total of 111 Raman spectra from arterial fragments were used to develop the model, and those spectra were compared to the spectra of collagen, fat cells, smooth muscle cells, calcification, and cholesterol in a linear fit model. Non-atherosclerotic (NA), fatty and fibrous-fatty atherosclerotic plaques (A) and calcified (C) arteries exhibited different spectral signatures related to different morphological structures presented in each tissue type. Discriminant analysis based on Mahalanobis distance was employed to classify the tissue type with respect to the relative intensity of each compound. This model was subsequently tested prospectively in a set of 55 spectra. The simplified diagnostic model showed that cholesterol, collagen, and adipocytes were the tissue constituents that gave the best classification capability and that those changes were correlated to histopathology. The simplified model, using spectra obtained from a few tissue morphological and biochemical constituents, showed feasibility by using a small amount of variables, easily extracted from gross samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The pericardial biopsy has opened a new perspective for the etiologic diagnosis of pericardial effusions, because adequate pericardial visualization via the use of a video camera can provide more accurate results. We assessed the usefulness of videopericardioscopy for the diagnosis and treatment of pericardial effusion of indeterminate origin. Methods. We conducted a retrospective study of clinical data from patients who underwent videopericardioscopy examination for pericardial effusion without an established diagnosis. The video-assisted pericardioscopy procedure was performed through a small incision in the xiphoid area. Results. From January 1998 to January 2007, 101 consecutive patients underwent videopericardioscopy evaluation for pericardial effusion. Ten patients were excluded because of lack of data. Fifty men and 41 women were included ( mean age, 50 years; range, 14-76 years). All of the patients had moderate or significant pericardial effusion as demonstrated by echocardiography or computed tomography. The following diagnoses for the pericardial effusions were established: nonspecific inflammation, 50 cases ( 54.94%); neoplastic disorders, 22 cases ( 24.17%); tuberculous, 11 cases ( 12.08%); bacterial inflammatory process, 3 cases ( 3.29%); chylopericardial, 2 cases ( 2.19%); fungal infection, 2 cases ( 2.19%); and viral infection, 1 case ( 1.09%). Pericardioscopy evaluation provided the definitive diagnosis via the pericardial biopsy in 36.26% of the cases and via the results of fluid analyses in 13.18% of the cases; the use of both methods established the definitive diagnosis in 45.05% of the cases in this group of patients. The overall morbidity rate was 4.3%, and the most common complication was arrhythmia due to intraoperative manipulation, which ceased with the removal of the instruments from the pericardial cavity. We had 1 death, by cardiac tamponade, in the perioperative period. Conclusion. Videopericardioscopy is a safe and efficient method for obtaining a better diagnosis of and satisfactory therapeutic results for pericardial effusions of indeterminate cause, and such results are obtained via an improved exploration of the pericardial cavity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study seeks to determine, through functional gait assessment in different irradiation sites, the influence of a low-intensity GaAsAl laser beam on an injury caused by crushing the peroneal nerve in rats. Methods: 53 rats were used, which were divided into six groups: normal, injured and untreated, injured and treated using placebo, injured and treated in the bone marrow, injured and treated in the nerve, and injured and treated in both (nerve and bone marrow). The peroneal nerve was crushed using a pair of tweezers, and subsequently treated with laser for 28 consecutive days. The functional gait evaluation analyzed the footprints, which were recorded with a video camera on an acrylic bridge in the preoperative period, and on postoperative days 14, 21 and 28, and assessed using PFI formula software. Results: In the functional gait evaluation, significant differences were found only on postoperative day 14. Conclusion: Based on the functional gait evaluation, low-intensity GaAs AI irradiation was able to accelerate and reinforce the process of peripheral nerve regeneration in rats on postoperative day 14, both in the bone marrow- and in the nerve-treated groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to qualify and quantify nerve fiber lesion following an acute crush injury, a morphologic and morphometric study was carried out in 25 Wistar rats divided into live groups of five animals each according to the crushing load applied, i.e., 500,1000, 5000, 10 000, and 15 000 g. The injury was produced under general anesthesia on a 5 mm-long intermediate segment of the right sciatic nerve for 10 min using a dead-weight machine. The animals were killed with an excessive dose of anesthetics 72 h later and submitted to perfusion with a fixing solution through the abdominal aorta immediately after death. Both the right and left sciatic nerves were removed and prepared for histologic and morphometric examinations: 5 mu m-thick sections stained with 1% Toluidine blue were examined under a light microscope equipped with a video camera linked to a computer loaded with a graphic program (KS 400). The morphometric studies included measuring total number of fibers, fiber density, fiber diameter, myelin fiber area, axon diameter, axon area and G ratio. The results showed that damage to the nerve fibers began to appear as early as with the 500g load and was similar in all groups despite the load applied, increasing with the 10000 and 15000g loads, although the external supporting tissues and small diameter fibers were preserved. The predominant type of lesion produced was axonotmesis. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. Methods: A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Results: Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). Conclusion: The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a recent ecological study of the ticks on animal trails within an area of Atlantic rainforest in south-eastern Brazil, Amblyomma aureolatum, A. brasiliense, A. incisum, A. ovale and Haemaphysalis juxtakochi were found questing on the vegetation. Most of the ticks recorded by a small, man-made dam on the forest border were A. dubitatum but a few A. brasiliense and A. cajennense, one A. incisum and one H. juxtakochi were also found. The seasonal activity of the ticks indicated that A. incisum and A. brasiliense had one generation/year. On the animal trails, most tick species and stages quested on the vegetation at a height of 30-40 cm above ground level. The questing larvae and adults of A. incisum tended to be found higher, however, with the greatest numbers recorded 40-50 cm (larvae) or 60-70 cm (adults) above ground level. Most of the adult ticks (81.1% -100%), nymphs (78.6%-100%) and larval clusters (100%) found on a forest trail remained questing at the same location over a 24-h period. Carbon-dioxide traps in the rainforest attracted, 50% of the ticks observed questing on the nearby vegetation and, curiously, the CO(2) traps set deep in the forest attracted far fewer ticks than similar traps set by the dam. The ecological relationships between the ticks, their hosts and the rainforest environment are discussed.