90 resultados para Arrhythmia, Sinus


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background-Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. Methods and Results-An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and third quartiles [Q1, Q3], 25.2, 30.0 kg). A 7-F ablation catheter was introduced into the pericardial space to perform epicardial mapping and deliver radiofrequency pulses on the atria. The pericardial space was entered in all 17 animals. In 15 (88%) animals, there was no hemodynamic instability (mean blood pressure monitoring, initial median, 80 mm Hg; Q1, Q3, 70, 86 mm Hg; final median, 88 mm Hg; Q1, Q3, 80, 96 mm Hg; P=0.426). In these 15, a mild hemorrhagic pericardial effusion was identified and aspirated (median, 20 mL; Q1, Q3, 15, 30 mL) during the procedure, and postmortem gross analysis revealed that the atrial perforation was closed in these animals. In 2 (12%) of the 17 animals, there was major pericardial bleeding with hemodynamic collapse. On gross examination, it was found that pericardial space was accessed through right ventricular perforation in 1 animal and the tricuspid annulus in the other. After the initial study, we used an occlusion device in 3 other animals to attempt to seal the puncture (2 at the right atrial appendage and 1 at the right ventricle). These 3 animals had no significant pericardial bleeding. Conclusions-Transatrial endovascular right atrial appendage puncture may provide a potential alternative route for pericardial access. Further studies are needed to evaluate its safety with longer and more-complex procedures before being applied in clinical settings. (Circ Arrhythm Electrophysiol. 2011;4:331-336.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thus far, little has been written concerning echocarchographic identification of the oblique of the left atrium, or Marshall`s vein. There is much discussion, nonetheless, on the potential significance of the vein, or its ligamentous remnant, as an arrhythmic substrate. We describe here four patients in whom transthoracic echocardiography revealed a venous structure protruding within the cavity of the left atrium. We discuss the possibility that these structures represent Marshall`s vein, albeit probably as part of a persistent left superior caval vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This study of a chronic porcine postinfarction model examined whether linear epicardial cryoablation was capable of creating large, homogenous lesions in regions of the myocardium including scarred ventricle. Endocardial and epicardial focal cryolesions were also compared to determine if there were significant differences in lesion characteristics. Methods: Eighty focal endocardial and 28 focal epicardial cryoapplications were delivered to eight normal caprine and four normal porcine ventricular myocardium, and 21 linear cryolesions were applied along the border of infarcted epicardial tissue in a chronic porcine infarct model in six swines. Results: Focal endocardial cryolesions in normal animals measured 9.7 +/- 0.4 mm (length) by 7.3 +/- 1.4 mm (width) by 4.8 +/- 0.2 mm (depth), while epicardial lesions measured 10.2 +/- 1.4 mm (length) by 7.7 +/- 2 mm (width) by 4.6 +/- 0.9 mm (depth); P > 0.05. Linear epicardial cryolesions in the chronic porcine infarct model measured 36.5 +/- 7.8 mm (length) by 8.2 +/- 1.3 mm (width) by 6.0 +/- 1.2 mm (depth). The mean depth of linear cryolesions applied to the border of the infarct scar was 7 +/- 0.7 mm, as measured by magnetic resonance imaging. Conclusions:Cryoablation can create deep lesions when delivered to the ventricular epicardium. Endocardial and epicardial cryolesions created by a focal cryoablation catheter are similar in size and depth. The ability to rapidly create deep linear cryolesions may prove to be beneficial in substrate-based catheter ablation of ventricular arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

People with schizophrenia show a two to threefold increased risk to die prematurely than those without schizophrenia. Patients` life style, suicide, premature development of cardiovascular disease, high prevalence of metabolic syndrome and sudden cardiac death are well-known causes of the excess mortality. The exact pathophysiological cause of sudden death in schizophrenia is unknown, but it is likely that cardiac arrhythmia and respiratory abnormalities play potential role. Some antipsychotics may be associated with cardiovascular adverse events (e.g., QT interval prolongation) and lesions in specific brain regions, such as cerebella may be associated with respiratory abnormalities, suggesting that metabolic and brain dysfunction could lead to sudden cardiac death in patients with schizophrenia. However, exact knowledge regarding the association of these findings and schizophrenia is lacking. As subclinical hyperthyroidism has been linked with increased risk of cardiovascular disease and cerebella progressive atrophy has been observed in patients with schizophrenia, we propose in this paper that subclinical thyroid dysfunction and cerebella volume loss could be considered as new risk factor for sudden cardiac death in schizophrenia. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been limited investigation of parturition in the bitch and there is little information published on clinical and obstetrical examination other than opinion and anecdote. While there are substantial data on haemodynamic and vascular changes during normal parturition in humans, little is known about the physiological events in the dog. This study was aimed at maternal haemodynamic changes occurring during normal parturition and to investigate how these were modified in bitches with dystocia (DYST) treated either medically or via assisted delivery and caesarean operation. Three groups of 10 bitches were investigated; those with normal parturition, those with DYST corrected by manipulative assistance or caesarean operation and those with uterine inertia treated by oxytocin administration. Heart rate, systolic and diastolic blood pressure, electrocardiogram and blood glucose concentration were measured pre-partum, intra-partum, immediately after parturition and 1 h later. Heart rate was high at all times throughout the study and the majority of bitches had normal sinus rhythm. Blood pressure was generally within the normal range, and although systolic and diastolic blood pressure was highest during the intra-partum period and sometimes during the immediate post-partum period, there were no significant differences between groups. All bitches had blood glucose concentrations within the normal range throughout the study although pre-partum concentrations were statistically lower than many of the other time periods. The study provides useful physiological data that will facilitate monitoring and clinical management of bitches throughout normal parturition and DYST.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To report clinical complications (pain, necrotic gingival tissue and bone sequestration) resulting from accidental injection of sodium hypochlorite. Summary Root canal treatment is a routine clinical procedure with few reported complications. Sodium hypochlorite (NaOCl) is commonly used as an irrigant during the procedure because of its tissue-dissolving, antibacterial and lubricating properties. This paper presents a case in which accidental injection of sodium hypochlorite into the lingual gingiva of a female patient caused gingival and bone necrosis. Surgical intervention was required. Key learning points Sodium hypochlorite is dangerous if injected into the tissues. The presentation of sodium hypochlorite in glass, anaesthetic type cartridges is potentially dangerous, and should be condemned. All healthcare workers should check carefully the contents of any syringe before injecting into patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to analyze electrocardiographic alterations during dental implant surgeries when local anesthetic agents were used. Materials and Methods: Twenty implants were placed in 18 healthy patients. An electrocardiogram and Wincardio software were used to gather recordings from 12 static leads every 2 minutes, continuously record coronary artery (D2) derivations, and automatically measure the following electrocardiographic parameters: heart rate, duration and amplitude of the P wave, PR segment duration, ST segment deviation, QRS complex duration, and duration of the RR, QT, and corrected QT (QTc) intervals. Results: Analysis of variance of the values obtained at the different stages showed significant differences (P < .05) for the heart rate and for the duration of the RR and QT intervals. The heart rate increased during the anesthesia, incision, and bone drilling stages, reaching a peak during drilling. Duration of the RR and QT intervals decreased during the incision and drilling stages. Among the electrocardiographic parameters individually assessed, several altered values were found for the duration of the P wave, the QRS complex, and the QT and QTc intervals. Sinusal tachycardia and bradycardia, sinusal arrhythmia, supraventricular extrasystole, ventricular extrasystole, and T-wave inversion were detected. Conclusion: Dental implant placement surgery may induce electrocardiographic alterations. The most frequently found arrhythmias were extrasystole and sinusal tachycardia. The anesthesia, incision, and bone drilling stages exhibited the highest heart rate values and the shortest durations of the RR and QT intervals. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:412-418

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To histomorphometrically investigate the repair of critical size defects (CSDs) and bone augmentation in cranial walls using block of sintered bovine-derived anorganic bone (sBDAB) graft. Forty guinea-pigs were divided into test (n=20) and CSD control (n=20) groups. In each animal, a full-thickness bone defect with 9.5 mm diameter was made in the frontal bone. The defects were filled with an sBDAB block soaked in blood in the test group and with blood clot in the CSD control group. The skulls were collected at 0 h (n=2) and 30, 90 and 180 days (n=6/group and period) postoperatively. The volume density and total volume of newly formed bone, sBDAB, blood vessels and connective tissue, vertical thickness of removed bone plug, sBDAB block and graft area were evaluated. The vertical thickness of the adapted sBDAB block was 3.8 times higher than that of the removed bone plug and did not show significant difference between periods, filling in average 29.8% of the total graft region. The sBDAB block exhibited complete osseointegration with the borders of the defect at 90 days. At 90 and 180 days, the vertical thickness of the graft was 279% in the average, and the total volume of bone augmentation was, respectively, 78.8% and 148.5% higher compared with the removed bone plug. The defects of the CDS control group showed limited osteogenesis and filling by connective tissue plus tegument. The sBDAB block can be used to promote repair of CSDs and bone augmentation in the craniomaxillofacial region, due to its good osteoconductive and slow resorptive properties. To cite this article:Cestari TM, Granjeiro JM, de Assis GF, Garlet GP, Taga R. Bone repair and augmentation using block of sintered bovine-derived anorganic bone graft in cranial bone defect model.Clin. Oral Impl. Res. 20, 2009; 340-350.doi: 10.1111/j.1600-0501.2008.01659.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 62-year-old man was referred for routine treatment of hyperplasia of the mucosa in the anterior lower jaw. An oroantral fistula was detected in the right superior alveolar ridge. The patient had no complaints. Plain radiographs showed a radiopaque foreign body in the posterior region associated with opacification of the maxillary sinus. Computed tomography showed the same hyperdense foreign body located in the posterior lower part of the sinus and an abnormal soft tissue mass in the entire right maxillary sinus. When asked about sinusitis, the patient mentioned occasional episodes of pus taste and intermittent crises of headache lasting for one week. The patient has been edentulous for 20 years. Sinus debridement was performed and the oroantral fistula was closed. The clinical suspicion of the presence of zinc oxide-eugenol paste was confirmed by microscopical and chemical analysis. After 6 months of follow-up, the fistula continued to be closed and sinusitis did not recur. This clinical case of maxillary chronic sinusitis illustrates a different odontogenic origin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The aims of this research were to evaluate the efficacy of a bioactive glass-ceramic (Biosilicate (R)) and a bioactive glass (Biogran (R)) placed in dental sockets in the maintenance of alveolar ridge and in the osseointegration of Ti implants. Material and methods Six dogs had their low premolars extracted and the sockets were implanted with Biosilicate (R), Biogran (R) particles, or left untreated. After the extractions, measurements of width and height on the alveolar ridge were taken. After 12 weeks a new surgery was performed to take the final ridge measurements and to insert bilaterally three Ti implants in biomaterial-implanted and control sites. Eight weeks post-Ti implant placement block biopsies were processed for histological and histomorphometric analysis. The percentages of bone-implant contact (BIC), of mineralized bone area between threads (BABT), and of mineralized bone area within the mirror area (BAMA) were determined. Results The presence of Biosilicate (R) or Biogran (R) particles preserved alveolar ridge height without affecting its width. No significant differences in terms of BIC, BAMA, and BABT values were detected among Biosilicate (R), Biogran (R), and the non-implanted group. Conclusions The results of the present study indicate that filling of sockets with either Biosilicate (R) or Biogran (R) particles preserves alveolar bone ridge height and allows osseointegration of Ti implants. To cite this article:Roriz VM, Rosa AL, Peitl O, Zanotto ED, Panzeri H, de Oliveira PT. Efficacy of a bioactive glass-ceramic (Biosilicate (R)) in the maintenance of alveolar ridges and in osseointegration of titanium implants.Clin. Oral Impl. Res. 21, 2010; 148-155.doi: 10.1111/j.1600-0501.2009.01812.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare new bone formation in maxillary sinus augmentation procedures using biomaterial associated with mesenchymal stem cells (MSCs) separated by two different isolation methods. Background: In regenerative medicine open cell concentration systems are only allowed for clinical application under good manufacturing practice conditions. Methods: Mononuclear cells, including MSCs, were concentrated with either the synthetic poylsaccharid (FICOLL) method (classic open system-control group, n = 6 sinus) or the bone marrow aspirate concentrate (BMAC) method (closed system-test group, n = 12 sinus) and transplanted in combination with biomaterial. A sample of the cells was characterized by their ability to differentiate. After 4.1 months (SD +/- 1.0) bone biopsies were obtained and analyzed. Results: The new bone formation in the BMAC group was 19.9% (90% confidence interval [CI], 10.9-29), and in the FICOLL group was 15.5% (90% CI, 8.6-22.4). The 4.4% difference was not significant (90% CI, -4.6-13.5; p = 0.39). MSCs could be differentiated into osteogenic, chondrogenic, and adipogenic lineages. Conclusion: MSCs harvested from bone marrow aspirate in combination with bovine bone matrix particles can form lamellar bone and provide a reliable base for dental implants. The closed BMAC system is suited to substitute the open FICOLL system in bone regeneration procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The caudal pressor area (CPA) is a brainstem area located close to the spinal cord. The activation of the CPA increases sympathetic activity and mean arterial pressure (MAP) by mechanisms dependent on the commissural nucleus of the solitary tract (commNTS) and rostroventrolateral medulla, however, the signals that activate the CPA to produce these responses are still unknown. Therefore, in the present study, we investigated the activity of glutamatergic and GABAergic mechanisms from the CPA and commNTS in rats exposed to hypoxia and the effects of the inhibition of CPA neurons on cardiorespiratory responses to peripheral chemoreceptor activation with i.v. sodium cyanide (NaCN). Male Sprague-Dawley rats (250-280 g, n=5-8/group) were used. In conscious rats, most of the commNTS neurons (66 +/- 11%) and part of the CPA neurons (36 +/- 7%) activated by hypoxia (8% O2) were glutamatergic (contained VGLUT2mRNA). Small part of the neurons activated during hypoxia was GABAergic (contained GAD-67mRNA) in the commNTS (9 +/- 4%) or the CPA (6 +/- 2%). In urethane anesthetized rats, the inhibition of CPA neurons with bilateral injections of muscimol (GABA-A agonist, 2 mM) reduced baseline MAP, splanchnic sympathetic nerve discharge (SND) and phrenic nerve discharge (PND). Muscimol into the CPA also reduced by around 50% the pressor and sympathoexcitatory responses and the increase in PND to peripheral chemoreceptor activation with NaCN (50 mu g/kg i.v.), without changing sympathetic baroreflex responses. These data suggest that CPA mechanisms facilitate cardiorespiratory responses to peripheral chemoreflex activation. Immunohistochemistry results also suggest that at least part of the CPA mechanisms activated by hypoxia is glutamatergic. (C) 2011 IBRO. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. A large-scale survey of doses to patients undergoing the most frequent radiological examinations was carried out in health services in Sao Paulo (347 radiological examinations per 1 000 inhabitants), the most populous Brazilian state. Methods. A postal dosimetric kit with thermoluminescence dosimeters was used to evaluate the entrance surface dose (ESD) to patients. A stratified sampling technique applied to the national health database furnished important data on the distribution of equipment and the annual number of examinations. Chest, head (skull and sinus), and spine (cervical, thoracic, and lumbar) examinations were included in the trial. A total of 83 rooms and 868 patients were included, and 1 415 values of ESD were measured. Results. The data show large coefficients of variation in tube charge, giving rise to large variations in ESD values. Also, a series of high ESD values associated with unnecessary localizing fluoroscopy were detected. Diagnostic reference levels were determined, based on the 75th percentile (third quartile) of the ESD distributions. For adult patients, the diagnostic reference levels achieved are very similar to those obtained in international surveys. However, the situation is different for pediatric patients: the ESD values found in this survey are twice as large as the international recommendations for chest radiographs of children. Conclusions. Despite the reduced number of ESD values and rooms for the pediatric patient group, it is recommended that practices in chest examinations be revised and that specific national reference doses and image quality be established after a broader survey is carried out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Along the internal carotid artery (ICA), atherosclerotic plaques are often located in its cavernous sinus (parasellar) segments (pICA). Studies indicate that the incidence of pre-atherosclerotic lesions is linked with the complexity of the pICA; however, the pICA shape was never objectively characterized. Our study aims at providing objective mathematical characterizations of the pICA shape. Methods and results Three-dimensional (3D) computer models, reconstructed from contrast enhanced computed tomography (CT) data of 30 randomly selected patients (60 pICAs) were analyzed with modern visualization software and new mathematical algorithms. As objective measures for the pICA shape complexity, we provide calculations of curvature energy, torsion energy, and total complexity of 3D skeletons of the pICA lumen. We further measured the posterior knee of the so-called ""carotid siphon"" with a virtual goniometer and performed correlations between the objective mathematical calculations and the subjective angle measurements. Conclusions Firstly, our study provides mathematical characterizations of the pICA shape, which can serve as objective reference data for analyzing connections between pICA shape complexity and vascular diseases. Secondly, we provide an objective method for creating Such data. Thirdly, we evaluate the usefulness of subjective goniometric measurements of the angle of the posterior knee of the carotid siphon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inside the `cavernous sinus` or `parasellar region` the human internal carotid artery takes the shape of a siphon that is twisted and torqued in three dimensions and surrounded by a network of veins. The parasellar section of the internal carotid artery is of broad biological and medical interest, as its peculiar shape is associated with temperature regulation in the brain and correlated with the occurrence of vascular pathologies. The present study aims to provide anatomical descriptions and objective mathematical characterizations of the shape of the parasellar section of the internal carotid artery in human infants and its modifications during ontogeny. Three-dimensional (3D) computer models of the parasellar section of the internal carotid artery of infants were generated with a state-of-the-art 3D reconstruction method and analysed using both traditional morphometric methods and novel mathematical algorithms. We show that four constant, demarcated bends can be described along the infant parasellar section of the internal carotid artery, and we provide measurements of their angles. We further provide calculations of the curvature and torsion energy, and the total complexity of the 3D skeleton of the parasellar section of the internal carotid artery, and compare the complexity of this in infants and adults. Finally, we examine the relationship between shape parameters of the parasellar section of the internal carotid artery in infants, and the occurrence of intima cushions, and evaluate the reliability of subjective angle measurements for characterizing the complexity of the parasellar section of the internal carotid artery in infants. The results can serve as objective reference data for comparative studies and for medical imaging diagnostics. They also form the basis for a new hypothesis that explains the mechanisms responsible for the ontogenetic transformation in the shape of the parasellar section of the internal carotid artery.