81 resultados para self modifying code
Resumo:
Psychosocial manifestations of erectile dysfunction (ED) differ across cultures. Understanding the treatment response to ED medications within cultural groups can aid in resource allocation and in developing treatment strategies. Evaluate the effect of sildenafil treatment on self-esteem, confidence, and sexual relationship satisfaction in Brazilian men with ED. The Self-Esteem and Relationship (SEAR) questionnaire, a validated, 14-question instrument developed to specifically address self-esteem and relationship issues within the context of ED. Men aged 18 years or older with a clinical diagnosis of ED (<= 21 on the Sexual Health Inventory for Men) and in a stable relationship with a partner during the study were eligible. The primary end point was a change from baseline in the self-esteem subscale of the SEAR questionnaire. Thirteen Brazilian sites participated in a randomized, double-blind, placebo-controlled trial of sildenafil treatment for ED. Patients were randomized to receive either 50 mg of sildenafil (adjustable to 25 mg or 100 mg based on patient response) or matching placebo approximately 1 hour before anticipated sexual activity but not more than once a day. At the end of double-blind treatment, 63 and 66 patients in the placebo and sildenafil groups, respectively, from 13 Brazilian sites were assessed for efficacy. Brazilian patients receiving sildenafil had significantly greater improvements in their scores on the SEAR self-esteem subscale (42.9 [95% confidence interval 35.7-50.0]) compared with placebo (21.1 [95% confidence interval 13.7-28.6]; P < 0.0001). Effect sizes ranged from 0.91 to 1.25 for individual SEAR components. The psychosocial parameters in Brazilian men with ED assessed by the SEAR questionnaire showed significant improvements in self-esteem, confidence, and relationships after treatment with sildenafil. Glina S, Damiao R, Abdo C, Afif-Abdo J, Tseng L-J, and Stecher V. Self-esteem, confidence, and relationships in Brazilian men with erectile dysfunction receiving sildenafil citrate: A randomized, parallel-group, double-blind, placebo-controlled study in Brazil. J Sex Med 2009;6:268-275.
Resumo:
Purpose: To describe the use of self-expandable metallic stents to manage malignant colorectal obstructions and to compare the radiation dose between fluoroscopic guidance of stent placement and combined endoscopic and fluoroscopic guidance. Materials and Methods: From January 1998 to December 2007, 467 oncology patients undergoing colorectal stent placement in a single center were included in the study. Informed consent was obtained in all cases. All procedures were performed with fluoroscopic or combined fluoroscopic and endoscopic guidance. Inclusion criteria were total or partial colorectal obstruction of neoplastic origin. Exclusion criteria were life expectancy shorter than I month, suspicion of perforation, and/or severe colonic neoplastic bleeding. Procedure time and radiation dose were recorded, and technical and clinical success were evaluated. Follow-up was performed by clinical examination and simple abdominal radiographs at 1 day and at I, 3, 6, and 12 months. Results: Of 467 procedures, technical success was achieved in 432 (92.5%). Thirty-five treatments (7.5%) were technical failures, and the patients were advised to undergo surgery. Significant differences in radiation dose and clinical success were found between the fluoroscopy and combined-technique groups (P < .001). Total decompression was achieved in 372 cases, 29 patients showed remarkable improvement, 11 showed slight improvement, and 20 showed clinical failure. Complications were recorded in 89 patients (19%), the most significant were perforation (2.3%) and stent migration (6.9%). Mean interventional time and radiation dose were 67 minutes and 3,378 dGy.cm(2), respectively. Conclusions: Treatment of colonic obstruction with stents requires a long time in the interventional room and considerable radiation dose. Nevertheless, the clinical benefits and improvement in quality of life justify the radiation risk.
Resumo:
Background Two recent clinical studies support the feasibility of trials to evaluate the disease-modifying properties of lithium in Alzheimer`s disease, although no benefits were obtained from short-term treatment. Aims To evaluate the effect of long-term lithium treatment on cognitive and biological outcomes in people with amnestic mild cognitive impairment (aMCI). Method Forty-five participants with aMCI were randomised to receive lithium (0.25-0.5mmol/l) (n=24) or placebo (n = 21) in a 12-month, double-blind trial. Primary outcome measures were the modification of cognitive and functional test scores, and concentrations of cerebrospinal fluid (CSF) biomarkers (amyloid-beta peptide (A beta(42)), total tau (T-tau), phosphorylated-tau) (P-tau). Trial registration: NCT01055392. Results Lithium treatment was associated with a significant decrease in CSF concentrations of P-tau (P=0.03) and better perform-ance on the cognitive subscale of the Alzheimer`s Disease Assessment Scale and in attention tasks. Overall tolerability of lithium was good and the adherence rate was 91%. Conclusions The present data support the notion that lithium has disease-modifying properties with potential clinical implications in the prevention of Alzheimer`s disease.
Resumo:
Self-efficacy is defined as one`s belief that one can perform the necessary behaviors to achieve one`s goals. This belief is one of the most powerful motivational predictors of how well a person will perform at almost any endeavor. Limited information is available, however, about self-efficacy in the organ transplantation population. This study aimed to identify the self-efficacy belief among liver transplant candidates and recipients and compare these results with demographic characteristics. The authors analyzed 100 patients who were candidates and recipients for liver transplantation in a Brazilian center. The average self-efficacy score for the candidates was significantly lower than for the recipients. Future investigation is necessary to explore possible interventions to be taken before and after liver transplantation that could influence self-efficacy of the organ transplantation patients.
Resumo:
Introduction: Parkinson`s disease (PD) is a neurodegenerative disorder with prominent motor manifestations and many other non-motor symptoms that significantly decrease quality-of-life and are frequently under-recognized, for example depression. Objective: To study the validity of a Brazilian version of the Zung Self-rating Depression Scale (SDS) for the diagnosis of depression in patients with PD. Methods: We evaluated 78 consecutive non demented patients over the age of 40 with diagnosis of PD at a Movement Disorders Outpatient Clinic, who could read and understand questionnaires. They completed the SIDS and the Geriatric Depression Scale with 15 items (GDS-15). The diagnosis of depression was made after a structured clinical interview based on DSM-IV criteria for the diagnosis of major depression (SCID-CV). Results: The prevalence of major depression was 23.1%. Cronbach`s alpha was 0.73 and the area under the ROC curve was 0.93 for the SDS. The score index of 55 had a sensitivity of 88.9% and a specificity of 83.3% for the diagnosis of depression. The total scores of the SDS and GDS-15 were highly correlated (0.652, p < 0.0001) and correlated weakly with the scores of a motor scale. Discussion: The SIDS is a valid too] for screening depression in patients with PD since the specific SDS index of 55 is adopted. Two shortened versions could be used with good results. (C) 2009 Published by Elsevier Ltd.
Resumo:
Aminoglycoside antibiotics cause considerable toxicity to the inner ear. A progressive hearing loss at high frequencies resulted from the loss of hair cells in the base of the cochlea and a constant preoccupation with finding a treatment that protects against their toxic effects. A self-protection phenomenon to high ototoxic doses of gentamicin is proposed in this paper. Thirty-eight adult guinea pigs with normal hearing were tested using Preyer`s reflex and the distortion product otoacoustic emission (DPOAE) test, and their cochleae were analyzed by scanning electron microscopy. To the four groups investigated, group I (control) and group II (low dose, 10 mg/kg/day for 30 days) showed a normal DPOEA and normal outer hair cells; group III (high dose, 160 mg/kg/day for 10 days) showed the absence of DPOEA and damage to the outer hair cells; and group IV (low dose, 10 mg/kg/day for 30 days followed by a high dose of 160 mg/kg/day for 10 days) showed a normal DPOEA and normal outer hair cells. These results demonstrate that there was a considerable self-protection phenomenon by gentamicin.
Resumo:
Clinicians working in the field of congenital and paediatric cardiology have long felt the need for a common diagnostic and therapeutic nomenclature and coding system with which to classify patients of all ages with congenital and acquired cardiac disease. A cohesive and comprehensive system of nomenclature, suitable for setting a global standard for multicentric analysis of outcomes and stratification of risk, has only recently emerged, namely, The International Paediatric and Congenital Cardiac Code. This review, will give an historical perspective on the development of systems of nomenclature in general, and specifically with respect to the diagnosis and treatment of patients with paediatric and congenital cardiac disease. Finally, current and future efforts to merge such systems into the paperless environment of the electronic health or patient record on a global scale are briefly explored. On October 6, 2000, The International Nomenclature Committee for Pediatric and Congenital Heart Disease was established. In January, 2005, the International Nomenclature Committee was constituted in Canada as The International Society for Nomenclature of Paediatric and Congenital Heart Disease. This International Society now has three working groups. The Nomenclature Working Group developed The International Paediatric and Congenital Cardiac Code and will continue to maintain, expand, update, and preserve this International Code. It will also provide ready access to the International Code for the global paediatric and congenital cardiology and cardiac surgery communities, related disciplines, the healthcare industry, and governmental agencies, both electronically and in published form. The Definitions Working Group will write definitions for the terms in the International Paediatric and Congenital Cardiac Code, building on the previously published definitions from the Nomenclature Working Group. The Archiving Working Group, also known as The Congenital Heart Archiving Research Team, will link images and videos to the International Paediatric and Congenital Cardiac Code. The images and videos will be acquired from cardiac morphologic specimens and imaging modalities such as echocardiography, angiography, computerized axial tomography and magnetic resonance imaging, as well as intraoperative images and videos. Efforts are ongoing to expand the usage of The International Paediatric and Congenital Cardiac Code to other areas of global healthcare. Collaborative efforts are under-way involving the leadership of The International Nomenclature Committee for Pediatric and Congenital Heart Disease and the representatives of the steering group responsible for the creation of the 11th revision of the International Classification of Diseases, administered by the World Health Organisation. Similar collaborative efforts are underway involving the leadership of The International Nomenclature Committee for Pediatric and Congenital Heart Disease and the International Health Terminology Standards Development Organisation, who are the owners of the Systematized Nomenclature of Medicine or ""SNOMED"". The International Paediatric and Congenital Cardiac Code was created by specialists in the field to name and classify paediatric and congenital cardiac disease and its treatment. It is a comprehensive code that can be freely downloaded from the internet (http://www.IPCCC.net) and is already in use worldwide, particularly for international comparisons of outcomes. The goal of this effort is to create strategies for stratification of risk and to improve healthcare for the individual patient. The collaboration with the World Heath Organization, the International Health Terminology Standards Development Organisation, and the healthcare Industry, will lead to further enhancement of the International Code, and to Its more universal use.
Resumo:
Gene expression profiling by cDNA microarrays during murine thymus ontogeny has contributed to dissecting the large-scale molecular genetics of T cell maturation. Gene profiling, although useful for characterizing the thymus developmental phases and identifying the differentially expressed genes, does not permit the determination of possible interactions between genes. In order to reconstruct genetic interactions, on RNA level, within thymocyte differentiation, a pair of microarrays containing a total of 1,576 cDNA sequences derived from the IMAGE MTB library was applied on samples of developing thymuses (14-17 days of gestation). The data were analyzed using the GeneNetwork program. Genes that were previously identified as differentially expressed during thymus ontogeny showed their relationships with several other genes. The present method provided the detection of gene nodes coding for proteins implicated in the calcium signaling pathway, such as Prrg2 and Stxbp3, and in protein transport toward the cell membrane, such as Gosr2. The results demonstrate the feasibility of reconstructing networks based on cDNA microarray gene expression determinations, contributing to a clearer understanding of the complex interactions between genes involved in thymus/thymocyte development.
Resumo:
Background and Objectives: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. Study Design: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S3 Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. Results: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. ""Stretch mark""-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. Conclusion: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study. Lasers Surg. Med. 42:662-670, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
Purpose: The aim of this study was to detect the influence of (1) storage period of heparinized blood, (2) type of blood and presence of contaminant, (3) application mode of cleansing agents, and (4) efficacy of cleansing agents on contaminated enamel and dentin during the adhesion process of a one-step adhesive system. Materials and Methods: One hundred four human molars were sectioned into halves along the long axis for enamel and dentin tests. Heparinized and fresh blood were obtained from the same donor, applied and dried to maintain a layer of dry blood on the top of samples. The cleansing agents used were hydrogen peroxide, anionic detergent, and antiseptic solution. A one-step adhesive system (Clearfil S3 Bond) was applied on the dental surface, and composite resin cylinders were built up using Tygon tubing molds. After 24 h, the mu SBS test (1 mm/min) and fracture analysis were performed. Results: There was no statistically significant difference in bond strength values regarding the storage period of heparinized blood and the types of blood. Groups without contamination presented higher bond strengths than contaminated groups. The application mode of the cleansing agents had no influence on bond strength results. There was no statistically significant difference among cleansing agents and they were as effective as a water stream in counteracting the effect of blood contamination. Conclusion: Heparinized blood can be used as a contaminant for up to one week, and it is a reliable procedure to standardize the contaminant. The cleansing agents can be used without friction. A water stream is sufficient to remove blood contamination from dental tissues, before the application of a one-step adhesive system.
Resumo:
This study evaluated the influence of the dental substrates obtained after the use of different caries removal techniques on bonding of a self-etching system. Forty, extracted, carious, human molars were ground to expose flat surfaces containing caries-infected dentine surrounded by sound dentine. The caries lesions of the specimens were removed or not (control-G1) either by round steel burs and water-cooled, low speed, handpiece (G2), or by irradiation with an erbium, chromium:yttrium scandium gallium garnet (Er,Cr:YSGG) laser (2W, 20 Hz, 35.38 J/cm(2), fiber G4 handpiece with 0.2826 mm(2), non-contact mode at a 2 mm distance, 70% air/20% water-G3) or using a chemo-mechanical method (Carisolv-G4). Caries-infected, caries-affected and sound dentines were submitted to a bonding system followed by construction of a resin-based composite crown. Hour-glass shaped samples were obtained and submitted to a micro-tensile bond test. The bond strength data were compared by analysis of variance (ANOVA), complemented by Tukey`s test (P <= 0.05). The samples of sound dentine presented higher bond strengths than did samples of caries-affected dentine, except for the groups treated with the Er,Cr:YSGG laser. The highest bond strengths were observed with the sound dentine treated with burs and Carisolv. The bond strengths to caries-affected dentine were similar in all groups. Additionally, bonding to caries-affected dentine of the Er,Cr:YSGG laser and Carisolv groups was similar to bonding to caries-infected dentine. Thus, caries-affected dentine is not an adequate substrate for adhesion. Moreover, amongst the caries removal methods tested, the Er,Cr:YSGG laser irradiation was the poorest in providing a substrate for bonding with the tested self-etching system.
Resumo:
The adhesive performance on deproteinized dentin of different self-adhesive resin cements was evaluated through microtensile bond strength (mu TBS) analysis and scanning electron microscopy (SEM). Occlusal dentin of human molars were distributed into different groups, according to the categories: adhesive cementation with two-step bonding systems-control Groups (Adper Single Bond 2 + RelyX ARC/3M ESPE; One Step Plus + Duolink/Bisco; Excite + Variolink I/Ivoclar Vivadent) and self-adhesive cementation-experimental groups (Rely X Unicem/3M ESPE; Biscem/Bisco; MultiLink Sprint/Ivoclar Vivadent). Each group was subdivided according to the dentin approach to: alpha, maintenance of collagen fibers and beta, deproteinization. The mean values were obtained, and submitted to ANOVA and Tukey test. Statistical differences were obtained to the RelyX Unicem groups (alpha = 13.59 MPa; beta = 30.19 MPa). All the BIS Group specimens failed before the mechanical tests. Dentinal deproteinization provided an improved bond performance for the self-adhesive cement Rely X Unicem, and had no negative effect on the other cementing systems studied. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 98B: 387-394, 2011.
Resumo:
Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To evaluate in vitro the microshear bond strength of adhesive systems applied to dentin according to manufacturers` instructions, associated or not with a hydrophobic layer of unfilled resin. Materials and Methods: Six self-etching adhesives (Clearfil SE Bond, Kuraray Medical; AdheSE, lvoclar Vivadent; Xeno III, Dentsply; I Bond, Heraeus-Kulzer; Bond Force, Tokuyama; Futurabond DC, Voco) were tested. The labial dentin of sixty bovine incisors was exposed, and the teeth were divided into two groups according to the application or not of an extra hydrophobic resin layer (Scotchbond Multi Purpose Plus, bottle 3). Six composite cylinders (Filtek Z250, 3M ESPE) were built up on each treated surface. Specimens were stored in distilled water at 37 C for 24 h and then subjected to the microshear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. Microshear bond strength values were analyzed by 2-way ANOVA and Tukey`s post-hoc test. Failure mode was determined using a stereomicroscope under 20X magnification. Results: The application of the hydrophobic resin layer did not affect bond strength, except for AdheSE. However, the bond strengths with the hydrophobic layer were similar among the six tested systems (Clearfil: 17.1 +/- 7.9; AdheSE: 14.5 +/- 7.1; Xeno III: 12.8 +/- 7.7; I Bond: 9.5 +/- 5.8; Bond Force: 17.5 +/- 4.1; Futurabond: 7.7 +/- 2.3). When used as recommended by the manufacturers, Bond Force presented statistically higher bond strength than AdheSE and I Bond (p < 0.05) (Clearfil 10.4 +/- 4.9; AdheSE 1.6 +/- 1.6; Xeno III: 9.0 +/- 3.8; I Bond: 3.0 +/- 1.5; Bond Force: 14 +/- 3.9; Futurabond: 8.8 +/- 3.8). Failure mode was predominantly adhesive. Conclusion: The bond strength of the self-etching systems tested was not significantly affected by the application of a hydrophobic layer, but a significant improvement was observed in AdheSE.
Resumo:
This study evaluated the effect of the C-factor and dentin preparation method (DPM) in the bond strength (BS) of a mild self-etch adhesive; the study also observed the SEM superficial aspects of the corresponding smear layer. For purposes of this study, 25 molars (n=5) were used in a bond strength test. The molars were divided into two parts (buccal and lingual): one part received a Class V cavity (C-factor=3) and the other received a flat surface (C-factor=0) with the same bur type (coarse diamond or carbide bur and fine diamond or carbide bur), both within the same dentin depth. Five teeth were prepared with wet 60-grit and 600-grit SiC papers. After restoration with Clearfil SE Bond, microtensile beans (0.8 mm(2)) were prepared and tested after 24 hours in a universal testing machine (0.5 mm/minute). An additional two teeth for each DPM were prepared for SEM evaluation of the smear layer superficial aspects. The BS values were submitted to one-way ANOVA, considering only the DPM (flat surfaces) and two-way ANOVA (C-Factor x DPM, considering only burs) with p=0.05. Although the DPM in the flat surfaces was not significant, the standard deviations of carbide bur-prepared specimens were markedly lower. The BS was significantly lower in cavities. The fine carbide bur presented the most favorable smear layer aspect. It was concluded that different dentin preparation methods could not prevent the adverse effect in bond strength of a high C-factor. A coarse cut carbide bur should be avoided prior to a mild self-etch adhesive, because it adversely affected bond strength. In contrast, a fine cut carbide bur provided the best combination: high bond strength with low variability, which suggests a more reliable bond strength performance.