83 resultados para biological attachment devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic field effects on the conductivity of different types of organic devices: undoped and dye doped aluminium (III) 8-hydroxyquinoline (Alq(3))-based organic light emitting diodes (OLEDs), electron-only Alq(3)-based diodes, and a hole-only N,N`-diphenyl-N,N`-bis(1-naphthyl)1,1`-biphenyl-4,4`-diamine (alpha-NPD)-based diode were studied at room temperature. Only negative magnetoresistance (MR) was observed for the Alq(3)-based devices. The addition of a rubrene dye in Alq(3)-based OLEDs quenches the MR by a factor of 5. The alpha-NPD hole-only device showed only positive MR. Our results are discussed with respect to the actual models for MR in organic semiconductors. Our results are in good agreement with the bipolaron model. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: A rapid-growing mycobacteria biological prosthetic valve (BPV) endocarditis related to prosthetic manufacturing process is described in Brazil. Methods: From 1999 to 2008, thirty-nine patients underwent BPV replacement due to culture-negative suspected endocarditis. All these cases had histological sections stained by Ziehl-Neelsen method. Clinical and microbiological data were reviewed in all acid-fast bacilli (AFB) positive cases. The 16S-23S internal transcribed sequence (ITS) was amplified using DNA extracted from paraffin-embedded samples, digested with restrictions enzymes and/or sequenced. Results: Eighteen AFB positive BPV (18/39)(46%) were implanted in 13 patients and were from the same manufacturer. Four of them were implanted in other hospitals. Thirteen BPV were histologically proven endocarditis and five showed a colonization pattern. The examination of six non-implanted ""sterile"" BPV from this manufacturer resulted in 5 AFB positive. Mycobacterium chelonae was the AFB identified by ITS restriction analysis and sequencing. Conclusions: Rapid-growing mycobacteria infections must be suspected and Ziehl-Neelsen stain always performed on histology of either early or late BPV endocarditis, particularly when blood cultures are negative. (C) 2010 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate bone responses to a novel bioactive fully crystallized glass-ceramic of the quaternary system P(2)O(5)-Na(2)O-CaO-SiO(2) (Biosilicates (R)). Although a previous study demonstrated positive effects of Biosilicate (R) on in vitro bone-like matrix formation, its in vivo effect was not studied yet. Male Wistar rats (n = 40) with tibial defects were used. Four experimental groups were designed to compare this novel biomaterial with a gold standard bioactive material (Bioglass (R) 45S5), unfilled defects and intact controls. A three-point bending test was performed 20 days after the surgical procedure, as well as the histomorphometric analysis in two regions of interest: cortical bone and medullary canal where the particulate biomaterial was implanted. The biomechanical test revealed a significant increase in the maximum load at failure and stiffness in the Biosilicate group (R) (vs. control defects), whose values were similar to uninjured bones. There were no differences in the cortical bone parameters in groups with bone defects, but a great deal of woven bone was present surrounding Biosilicate (R) and Bioglass (R) 45S5 particulate. Although both bioactive materials supported significant higher bone formation; Biosilicate (R) was superior to Bioglass (R) 45S5 in some histomorphometric parameters (bone volume and number of osteoblasts). Regarding bone resorption, Biosilicate (R) group showed significant higher number of osteoclasts per unit of tissue area than defect and intact controls, despite of the non-significant difference in the osteoclastic surface as percentage of bone surface. This study reveals that the fully crystallized Biosilicate (R) has good bone-forming and bone-bonding properties. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 978: 139-147, 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Telecanthus, the lateral displacement of the medial canthus, can be a congenital deformity or can occur after facial trauma or tumor resection. Treatment of telecanthus remains a challenge for plastic surgeons. For proper correction, it is necessary to shift the medial canthus medially, fixing its tendon to the bone. The ideal technique would allow easy, safe, and stable fixation of the tendon, permit a unilateral approach with minimal incisions, and be cost-effective. The purpose of this study was to evaluate the feasibility and results (immediate and long-term) of medial telecanthus repair using ipsilateral titanium microanchor fixation. Nine patients, 7 with unilateral telecanthus and 2 with bilateral telecanthus, underwent ipsilateral canthopexy involving a microanchor device. Anthropometric measurements of the orbital regions were taken before, immediately after, and at 1 year after surgery. Data for the affected sides were compared with those for the unaffected sides, and the evolution of those values was assessed throughout the 1-year follow-up period. For all patients, the final values were lower than those initially obtained. At 1 year after surgery, the intercanthal distance was reduced to age-adjusted normal values in all cases. On the operated side, stable improvement was observed in terms of the distance from the medial canthus to the midline, although some degree of recurrence was noted in most of the patients. The use of a microanchor system for medial canthopexy can be considered an easily performed and effective option for treating canthal dystopia, especially when an ipsilateral approach is preferred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Several medical devices used during hemodynamic procedures, particularly angiographic diagnostic and therapeutic cardiac catheters, are manufactured for single use only. However, reprocessing and reuse of these devices has been reported, to determine the frequency of reuse and reprocessing of single-use medical devices used during hemodynamic procedures in Brazil and to evaluate how reprocessing is performed. Design. National survey, conducted from December 1999 to July 2001. Methods. Most of the institutions affiliated with the Brazilian Society of Hemodynamic and Interventional Cardiology were surveyed by use of a questionnaire sent in the mail. Results. The questionnaire response rate was 50% (119 of 240 institutions). Of the 119 institutions that responded, 116 (97%) reported reuse of single-use devices used during hemodynamic procedures, and only 26 (22%) reported use of a standardized reprocessing protocol. Cleaning, flushing, rinsing, drying, sterilizing and packaging methods varied greatly and were mostly inadequate. Criteria for discarding reused devices varied widely. Of the 119 institutions that responded, 80 (67%) reported having a surveillance system for adverse events associated with the reuse of medical devices, although most of these institutions did not routinely review the data, and only 38 (32%) described a training program for the personnel who reprocessed single-use devices. Conclusions. The reuse of single-use devices used during hemodynamic procedures was very frequent in hospitals in Brazil. Basic guidance on how to reuse and reprocess single-use medical devices is urgently needed, because, despite the lack of studies to support reusing and reprocessing single-use medical devices, such devices are necessary in limited-resource areas in which these practices are current.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biofilm is a complex community of surface-associated cells enclosed in a polymer matrix. They attach to solid surfaces and their formation can be affected by growth conditions and co-infection with other pathogens. The presence of biofilm may protect the microorganisms from host defenses, as well as significantly reduce their susceptibility to antifungal agents. Pathogenic microbes can form biofilms on the inert surfaces of implanted devices such as catheters, prosthetic cardiac valves and intrauterine devices (IUDs). The present study was carried out to analyze the presence of biofilm on the surface of intrauterine devices in patients with recurrent vulvovaginal candidiasis, and to determine the susceptibility profile of the isolated yeasts to amphotericin B and fluconazole. Candida albicans was recovered from the IUDs and it was found to be susceptible to the antifungal agents when tested under planktonic growing conditions. These findings indicate the presence of the biofilm on the surface of the IUD as an important risk factor for recurrent vulvovaginal candidiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the first description of Leishmania (Viannia) shawi, few studies were performed with this parasite. In the present work, the in vivo and ex vivo behavior of L. (Viannia) shawi infection was studied using murine model. Peritoneal macrophages from BALB/c and C57BL/6 mice were infected with promastigotes in the stationary phase of growth; after 24 h, the infection index and nitric oxide (NO) levels in the supernatant of the cultures were analyzed. BALB/c and C57BL/6 mice were infected into the hind footpad, and at each 2 weeks, mice were sacrificed, and the histological changes of the skin inoculation site, parasitism, and humoral immune responses were evaluated during 8 weeks. Ex vivo experiments showed that macrophages of BALB/c presented higher infection index and lesser NO levels than macrophages of C57BL/6. In vivo experiments showed that BALB/c presented higher lesion size than C57BL/6 mice; similarly, the histopathological changes and the parasitism in skin were more exacerbate in BALB/c mice. In draining lymph nodes, the main change was increase of germinative centers, and parasites were detected from 6 weeks pi onwards in both mice strain. IgG was detected in BALB/c mice from 4 weeks, while in C57BL/6, from 6 weeks pi onwards. Taken together, these results indicate that BALB/c showed a classical behavior of susceptibility when compared to C57BL/6 mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The association between serological markers with the need of biological therapy for early rheumatoid arthritis (ERA) is not known, with few available data addressing this question. Objectives: To prospectively evaluate a cohort of patients with ERA (less than 12 months of symptoms) in order to determine the possible association between serological markers (rheumatoid factor (RF), anti-cyclic citrullinated peptide antibodies (anti-CCP), and citrullinated anti-vimentin (anti-Sa) with parameters of therapeutic outcome (this later defined by the need of introducing biological therapy). Patients and methods: Forty patients with early RA were evaluated at the time of diagnosis and have been followed for 3 years, in use of standardized therapeutic treatment. Demographic and clinical data were recorded, as well as serology tests (ELISA) for RF (IgM, IgG and IgA), anti-CCP (CCP2, CCP3 and CCP3.1) and anti-Sa in the initial evaluation and at 3, 6, 12, 18, 24 and 36 months of follow-up. As outcomes of the RA development, the need or not for biological therapy during the follow-up period were considered. Comparisons were made through the Student t test, mixed-effects regression analysis and analysis of variance (significance level of 5%). Results: The mean age was 45 (+/- 12) years; a female predominance was observed (90%). At the time of diagnosis, RF was observed in 50% of cases (RF IgA - 42%, RF IgG - 30% and RF IgM - 50%), anti-CCP in 50% (no difference between CCP2, CCP3 and CCP3. 1) and anti-Sa in 10%. After 3 years, no change in the RF prevalence neither in the anti-CCP was observed, but the anti-Sa increased to 17.5% (p = 0.001). Biological therapy was necessary in 22.5% of patients. The mean RF IgA and anti-CCP 2 levels during the 3 years were higher among patients who needed biological therapy (p <0.05 for both). Conclusion: Higher titles of RF and anti-CCP over time were associated with the need for biological therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the prognostic effect of epidermal growth factor receptor (EGFR), matrix metalloproteinases 2 and 9, and vascular endothelial growth factor expression in patients with locally recurrent oral carcinoma after salvage surgery. Design: Retrospective cohort study. Settings: Tertiary center cancer hospital. Patients: The charts of 111 patients with local recurrence of oral carcinomas were retrospectively analyzed. The previous treatment consisted of surgery in 33 patients (30.0%), radiotherapy with or without chemotherapy in 46 patients (41.0%), and surgery with adjuvant radiotherapy in 32 patients (29.0%). The expression of EGFR, matrix metalloproteinases 2 and 9, and vascular endothelial growth factor was analyzed with a tissue microarray immunohistochemical technique. Main Outcome Measures: Overall survival and cancer-specific survival (CSS). Results: The recurrences were diagnosed in less than 1 year in 69 patients (62.2%) and in more than 1 year in 42 patients (37.8%). The prognosis was worse in the group with the disease-free interval of less than 1 year (P=.01). Patients with more advanced disease (clinical stage of recurrence, III/IV) had worse rates of CSS (P=.04). Cases that were positive for EGFR had a 3-year CSS of 27.2%, while EGFR-negative cases had a 3-year CSS of 64.3% (P=.001). The expression of matrix metalloproteinases 2 (P=.83) and 9 (P=.15) and vascular endothelial growth factor (P=.86) was not significant in this group. In multivariate analysis, only the disease-free interval and the overexpression of EGFR were associated with a higher risk of cancer death. Conclusions: Local recurrence in oral carcinomas carries a poor prognosis. A disease-free interval of more than 1 year and a EGFR-negative expression are the main prognostic factors related to better CSS in patients treated with salvage surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bovine pericardium is a widely utilized biomaterial. Usually, after harvesting, it is advantageous that the pericardium be immersed in glycerol to improve its shelf life. This can induce some degree of toxicity in the material. The studies were performed in compliance with the rules of ISO 10993 and OECD 487, in the biological evaluation of medical devices. The material was prepared without previous washing. After sterilization by gamma radiation the pericardium was immersed in RPMI 1640 culture medium to fulfill the extraction condition. The same extract was employed in the cytotoxic and genotoxic tests. The procedures were carried out with Chinese hamster ovary cell line and to determine the cytotoxicity, a colorimetric method with the tetrazolium compound MTS was used. For the genotoxicity, following the in vitro micronucleus assay, the test was developed with and without metabolic activation. The Cytotoxicity Index was graphically estimated at the extract concentration of 78%. In the genotoxicity test, the average value of cell proliferation index was found to be 1.62 +/- 0.02 with S9 metabolic activator and 1.91 +/- 0.01 without S9 metabolic activator. Both values are similar to the negative control value in the micronucleus assay. We observed that although the pericardium preserved in glycerol shows a certain level of cytotoxicity, it does not show any genotoxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new gold(I) complex with 2-mercaptothiazoline (MTZ) with the coordination formula [AuCN(C(3)H(5)NS(2))] was synthesized and characterized by chemical and spectroscopic measurements, OFT studies and biological assays. Infrared (IR) and (1)H, (13)C and (15)N nuclear magnetic resonance (NMR) spectroscopic measurements indicate coordination of the ligand to gold(I) through the nitrogen atom. Studies based on OFT confirmed nitrogen coordination to gold(I) as a minimum of the potential energy surface with calculations of the hessians showing no imaginary frequencies. Thermal decomposition starts at temperatures near 160 degrees C, leading to the formation of Au as the final residue at 1000 degrees C. The gold(I) complex with 2-mercaptothiazoline (Au-MTZ) is soluble in dimethyl sulfoxide (DMSO), and is insoluble in water, methanol, ethanol, acetonitrile and hexane. The antibacterial activities of the Au-MTZ complex were evaluated by an antibiogram assay using the disc diffusion method. The compound showed an effective antibacterial activity against Staphylococcus aureus (Gram-positive) and Escherichia coli and Pseudomonas aeruginosa (Gram-negative) bacterial cells. Biological analysis for evaluation of the cytotoxic effect of the Au-MTZ complex was performed using HeLa cells derived from human cervical adenocarcinoma. The complex presented a potent cytotoxic activity, inducing 85% of cell death at a concentration of 2.0 mu mol L(-1). (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We report the validation of a method for the determination of acetaldehyde, acetone, methanol, and ethanol in biological fluids using manual headspace sample introduction and an acetonitrile internal standard. Method: This method uses a capillary column (I = 30 m, I.D. = 0.25 mm, dF = 0.25 mu m) installed in a gas chromatography-flame ionization detector (GC-FID) apparatus with a run time of 7.5 minutes. Results: Analysis of the retention times and the resolution of the analyte peaks demonstrated excellent separation without widening of the peaks. Precision and accuracy were good (interassay precision < 15% and recovery between 85% and 115%) in both blood and urine. Conclusion: The method was linear (r > 0.09) over the analytical measurement range (AMR) of each analyte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the effects of levonorgestrel-releasing intrauterine devices (LNG-IUD) and a gonadotropin-releasing hormone agonist (GnRHa) on uterine volume, uterine arteries pulsatility index (PI) and endometrial thickness before and after six months of endometriosis treatment. Sixty women aged 18-40 y were allocated randomly to one of two groups: LNG-IUDs were inserted in 30 women, and GnRHa monthly injections were performed on the other 30. All 60 women were submitted to transvaginal 2-D ultrasound scans on the day that the treatment started and then six months later. Measurements of uterine arteries PI, uterine volume and endometrial thickness were performed at both evaluations. The use of LNG-IUDs significantly decreased endometrial thickness (pre = 6.08 +/- 3.00 mm, post = 2.7 +/- 0.98 mm; mean +/- SD), as did the use of GnRHa (pre = 6.96 +/- 3.82 mm, post = 3.23 +/- 2.32 mm). The uterine volume decreased in the GnRHa group (pre = 86.67 +/- 28.38 cm(3), Post = 55.27 +/- 25.52 cm(3)), but not in the LNG-IUD group (pre = 75.77 +/- 20.88 cm(3), post = 75.97 +/- 26.62 cm(3)). Uterine arteries PI increased for both groups; however, the increase was higher in the GnRHa group (0.99 +/- 0.84 vs. 0.38 +/- 0.84, p = 0.007; PI increase in GnRHa and in LNG-IUD groups, respectively). In conclusion, levonorgestrel released directly onto the endometrium by the LNG-IUD induced smaller uterine changes than did the hypoestrogenism induced by GnRHa. Nevertheless, both promoted similar effects on endometrial thickness. (E-mail: wpmartins@gmail.com) (C) 2008 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.