62 resultados para Total e-marketing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the quality of induction and recovery, degree of muscle relaxation, clinically apparent potency and cardiopulmonary effects of racemic ketamine or S(+)-ketamine when used for total intravenous anesthesia in horses. Study design Prospective randomized clinical trial Animals Sixteen healthy stallions (323 +/- 99 kg), with a mean age of 6.2 years, undergoing castration. Methods Horses were pre-medicated with romifidine IV, 15 minutes before induction of anesthesia. Each animal was then randomly allocated to receive either diazepam and ketamine (DK) or diazepam and S(+)-ketamine (DKS) at similar doses to induce anesthesia. For maintenance of anesthesia, 1/4 of the initial bolus of ketamine alone or S(+)-ketamine alone was administered, as required. Heart rate (HR), respiratory rate (RR) and systolic blood pressure were measured before and at 10-minute intervals during recumbency. Time from induction to lateral recumbency, time from induction to first additional dose, time from last additional dose to return to sternal posture and time from last additional dose to standing were recorded, and a subjective evaluation of quality of induction, endotracheal intubation, muscle relaxation and quality of recovery was recorded. Results The quality of the induction and duration of anesthesia were similar in both groups. HR, RR and systolic blood pressure were not significantly different between groups. Although some animals which received DKS showed some minor excitatory effects (25% of them) during the induction of anesthesia, these animals received 32% fewer doses for the maintenance of anesthesia and the recovery scores were better. Conclusions and clinical relevance S(+)-ketamine showed some advantages over racemic ketamine, such as less anesthetic agent being required and better overall recovery from anesthesia. Further studies are needed to obtain the optimum induction dose for the S(+)-ketamine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of oxalate during total-etch bonding, under different dentin moisture conditions, over time. The null hypothesis tested was that microtensile bond strength (mu TBS) was not affected by oxalate treatment and dentin moisture during two evaluation periods. Methods: Extracted human third molars had their mid-coronal dentin exposed flat and polished with 600-grit SiC paper. The surfaces were etched with 35% phosphoric acid for 15 seconds, washed and blot dried. After etching, a 3% potassium oxalate gel was applied for 120 seconds, except for the control group (no desensitizer). The surface was then washed and left moist (Wet bonding) or air-dried for 30 seconds (Dry bonding). The surfaces were bonded with: (I) two 2-step etch-and-rinse adhesives: Single Bond (SB); Prime & Bond NT (PBNT) and (2) one 3-step etch-and-rinse adhesive: Scotchbond Multi Purpose (SBMP). Composite buildups were constructed incrementally with Tetric Ceram resin composite. Each increment was cured for 40 seconds. After storage in water for 24 hours or 1 year at 37 C, the specimens were prepared for mu TBS testing with a cross-sectional area of approximately 1 mm(2). They were then tested in tension in an Instron machine at 0.5 mm/minute. Data were analyzed by ANOVA and Student-Newman-Keuls at alpha = 0.05. Results: Application of potassium oxalate had no significant effect on the bond strengths of SBMP and PBNT, regardless of the surface moisture condition (P > 0.05). Conversely, reduced bond strengths were observed after oxalate treatment for SB in both moisture conditions, that being significantly lower when using a dry-bonding procedure (P < 0.05). Lower bond strength was obtained for PBNT when a dry-bonding technique was used, regardless of the oxalate treatment (P < 0.05). After aging the specimens for 1 year, bond strengths decreased. Smaller reductions were observed for SBMP, regardless of moisture conditions. For the WB technique, smaller reductions after 1 year were observed without oxalate treatment for SB and after oxalate treatment for PBNT. (Am J Dent 2010;23:137-141).