68 resultados para Metal-workers.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian emergency system is being reorganized as a hierarchy in the region of Ribeirao Preto, state of Sao Paulo. We found increased occupational risk for tuberculosis in this region tertiary reference center-a nurse technician (Incidence rate [IR] 526.3/100000 inhabitants) had a risk of tuberculosis 12.6 (95% confidence interval [CI], 2.57-37.23) greater than the city population (41.8/100000 inhabitants). The system reorganization will have to make the centers adequate to deal with this problem. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the importance of neosporosis in the animal health and production, the frequency of antibodies to Neospora caninum was evaluated in dairy cattle of the Southwestern region of Mato Grosso State, Brazil, in addition to serum samples obtained from dogs and humans living in the farms. A total of 1036 serum samples were analyzed, from which 932 were from dairy bovine females, 37 from dogs and 67 from humans, from 24 farms and examined by the indirect fluorescent antibody test (IFAT). Reactive human scrum samples were retested by Western-blotting to confirm the results. Antibodies to N. caninum were found in 499 cattle sera (53.5 %), with at least one positive in each farm, 25 dog sera (67.6 %) and seven human sera (10.5 %). There was no significant difference in the number of positive cattle sera according to age group. The results indicate a wide dissemination of N caninum in the studied region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>To evaluate the prevalence of antibodies to Chlamydophila psittaci 364 serum samples were collected from veterinarians, biologists, animal scientists, veterinary students, animal keepers and others employees in 20 zoos, and from veterinary practitioners in 10 Brazilian states. Subjects ranged from 15 to 64 years of age, with 268 (74%) males and 96 (26%) females. Chlamydial antibodies were determined by the complement fixation test (CFT) and specific anti-C. psittaci IgG antibodies were determined by the microimmunoflurescence (MIF) test. Complement fixation test showed 23.9% (87/364) and MIF test showed 4.7% (17/364) positive serum samples. Titres ranged from 16 to 256 in both assays, demonstrating evidence of recent or current infection. Although chlamydial antibodies were detected in workers of seventeen zoos, MIF test only detected specific C. psittaci antibodies in seven of them. Previous psittacosis infection was suspected in eight workers of two zoos, five of whom reported having pneumonia, while employed at the zoos. However, diagnosis was not established in any of these cases in the past. Results indicated the occurrence of infection and previous contact of Brazilian zoo workers with C. psittaci, as well as the zoonotic potential of psittacosis in this risk population. Other studies are necessary to evaluate the risk factors of infection in this population. This seroepidemiological survey confirmed the need to adopt preventive measures to control avian chlamydiosis and protect the health of zoo workers in the country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. There are no established clinical procedures for bonding zirconia to tooth structure using resin cements. Purpose. The purpose of this study was to evaluate the influence of metal primers, resin cements, and aging on bonding to zirconia. Material and methods. Zirconia was treated with commercial primers developed for bonding to metal alloys (Metaltite, Metal Primer II, Alloy Primer or Totalbond). Non-primed specimens were considered as controls. One-hundred disk-shaped specimens (19 x 4 mm) were cemented to composite resin substrates using Panavia or RelyX Unicem (n=5). Microtensile bond strength specimens were tested after 48 hours and 5 months (150 days), and failure modes were classified as type 1 (between ceramic/cement), 2 (between composite resin/cement) or 3 (mixed). Data were analyzed by 3-way ANOVA and Multiple Comparison Tukey test (alpha=.05). Results. The interactions primer/luting system (P=.016) and luting system/storage time (P=.004) were statistically significant. The use of Alloy Primer significantly improved the bond strength of RelyX Unicem (P<.001), while for Panavia, none of the primers increased the bond strength compared to the control group. At 48 hours, Panavia had statistically higher bond strength (P=.004) than Unicem (13.9 +/- 4.4MPa and 10.2 +/- 6.6MPa, respectively). However, both luting systems presented decreasing, statistically similar; values after aging (Panavia: 3.6 +/- 2.2MPa; Unicem: 6.1 +/- 5.3MPa). At 48 hours, Alloy Primer/Unicem had the lowest incidence of type 1 failure (8%). After aging, all the groups showed a predominance of type 1 failures. Conclusions. The use of Alloy Primer improved bond strength between RelyX Unicem and zirconia. Though the initial values obtained with Panavia were significantly higher than RelyX Unicem, after aging, both luting agents presented statistically similar performances. (J Prosthet Dent 2011;105:296-303)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Dental fractures can occur in endodontically treated teeth restored with posts. Purpose. The purpose of this study was to evaluate the in vitro fracture resistance of roots with glass-fiber and metal posts of different lengths. Material and methods. Sixty endodontically treated maxillary canines were embedded in acrylic resin, except for 4 mm of the cervical area, after removing the clinical crowns. The post spaces were opened with a cylindrical bur at low speed attached to a surveyor, resulting in preparations with lengths of 6 mm (group 6 mm), 8 mm (group 8 mm), or 10 mm (group 10 mm). Each group was divided into 2 subgroups according to the post material: cast post and core or glass-fiber post (n=30). The posts were luted with dual-polymerizing resin cement (Panavia F). Cast posts and cores of Co-Cr (Resilient Plus) crowns were made and cemented with zinc phosphate. Specimens were subjected to increasing compressive load (N) until fracture. Data were analyzed with 2-way ANOVA and the Tukey-Kramer test (alpha=.05). Results. The ANOVA analysis indicated significant differences (P<.05) among the groups, and the Tukey test revealed no significant difference among the metal posts of 6-mm length (26.5 N +/- 13.4), 8-mm length (25.2 N +/- 13.9), and 10-mm length (17.1 N +/- 5.2). Also, in the glass-fiber post group, there was no significant difference when posts of 8-mm length (13.4 N +/- 11.0) were compared with the 6-mm (6.9 N +/- 4.6) and 10-mm (31.7 N +/- 13.1) groups. The 10-mm-long post displayed superior fracture resistance, and the 6-mm-long post showed significantly lower mean values (P<.001). Conclusions. Within the limitations of this study, it was concluded that the glass-fiber post represents a viable alternative to the cast metal post, increasing the resistance to fracture of endodontically treated canines. (J Prosthet Dent 2009;101:183-188)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Self-reported tendinitis/tenosynovitis was evaluated by gender, age group, skin color, family income, and educational and psychological status. Methods The study was carried out in a representative sample of formally contracted Brazilian workers from a household survey. A total of 54,660 participants were included. Occupations were stratified according to estimated prevalences of self-reported injuries. Non-conditional logistic regression was performed, and all variables were analyzed in two occupational groups. Results The overall prevalence rate of tendinitis/tenosynovitis was 3.1%: 5.5% in high-prevalence occupations (n=10,726); and 2.5% in low-prevalence occupations (n=43,934). White female workers between the ages of 45 and 64 years and at a higher socioeconomic level were more likely to report tendinitis/tenosynovitis regardless of their occupational category. An adjusted OR = 3.59 [95% CI: 3.15-4.09] was found between tendinitis/tenosynovitis and psychological status. Conclusion Among formally contracted Brazilian workers, higher income can imply greater physical and psychological demands that, regardless of occupational stratum, increase the risk of tendinitis/tenosynovitis. Am. J. Ind. Med. 53:72-79, 2010. (C) 2009 Wiley-Liss, Inc.