69 resultados para Interferon- y
Resumo:
The genetic constitution of Afro-derived Brazilian populations is barely studied. To improve that knowledge, we investigated the AluYAP element and five Y-chromosome STRs (DYS19, DYS390, DYS391, DYS392, and DYS393) to estimate ethnic male contribution in the constitution of four Brazilian quilombos remnants: Mocambo, Rio das Ras, Kalunga, and Riacho de Sacutiaba. Results indicated significant differences among communities, corroborating historical information about the Brazilian settlement. We concluded that besides African contribution, there was a great European participation in the constitution of these four populations and that observed haplotype variability could be explained by gene flow to quilombos remnants and mutational events in microsatellites (STRs). Am. J. Hum. Biol. 21:354-356, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
This study examines the role of Th1 (interferon-gamma [IFN-gamma]) and Th2 (interleukin-4 [IL-4] and IL-10) cytokines, an intercellular adhesion molecule (ICAM-1), and a chemokine receptor (CCR5) in the pathogenesis of periapical lesions at different stages of development in knockout mice. For lesion induction, the first molar was opened and inoculated with 4 bacterial strains and left open to the oral environment. After 21 and 42 days, the IFN-gamma, IL-10, ICAM-1, and CCR5 knockout animals presented periapical lesions larger than those of wild-type animals. There was no statistically significant difference between periapical lesions induced in IL-4 knockout and wild-type animals during the periods evaluated. Our findings suggest an important role for IFN-gamma, IL-10, ICAM-1, and CCR5 in the pathogenesis of experimentally induced pulp infection and bone destruction as endogenous suppressor of periapical lesion development, whereas IL-4 appears to present a nonsignificant effect on periapical lesion modulation.
Resumo:
Background. Despite advances in immunosuppressive therapy in the past decade, allograft rejection remains an important cause of kidney graft failure. Cytokines play a major role in the inflammatory and immune responses that mediate allograft outcomes. Several studies have shown that the production of cytokines varies among individuals. These variations are determined by genetic polymorphisms, most commonly within the regulatory region of cytokine genes. The aim of the present study was to assess the effect of allelic variation on acute rejection episodes (ARE) or chronic allograft nephropathy (CAN) after kidney transplantation. Methods. To determine a possible correlation between the interferon (INF)-gamma +874 polymorphism and kidney allograft outcome, we isolated genomic DNA from 74 patients who underwent isolated kidney allografts and were classified into 2 groups-a rejection and a nonrejection group-for comparison with a control group of 163 healthy subjects. Results. We genotyped INF-gamma +874 polymorphisms in all groups. The transplant group showed a significantly increased homozygous genotype T/T (P = .0118) compared with healthy controls. Similarly, considering only patients with CAN, the homozygous genotype T/T (P = .0067) was significantly increased compared with the healthy controls. The rejection group indicated a significant increased homozygous genotype Tic compared with the control group (P = .0061). Conclusion. Homozygous genotype T/T was associated with increased levels of INF-gamma and greater numbers among the rejection and CAN cohorts.
Resumo:
Aicardi-Goutieres syndrome is a mendelian mimic of congenital infection and also shows overlap with systemic lupus erythematosus at both a clinical and biochemical level. The recent identification of mutations in TREX1 and genes encoding the RNASEH2 complex and studies of the function of TREX1 in DNA metabolism have defined a previously unknown mechanism for the initiation of autoimmunity by interferon-stimulatory nucleic acid. Here we describe mutations in SAMHD1 as the cause of AGS at the AGS5 locus and present data to show that SAMHD1 may act as a negative regulator of the cell-intrinsic antiviral response.
Resumo:
The aim of the present study was to report the occurrence of serious subnutrition, associated to intestinal bacterial overgrowth, in two patients submitted to bariatric surgery. Two female patients (body mass index, 49 and 50 kg/m(2), respectively) were submitted to Y-en-Roux gastric bypass. The first patient evolved a 52% loss of body weight within 21 months after surgery; the other, a 34% loss of initial body weight within 15 months after surgery, results corresponding, respectively, to 62 and 45 kg weight losses. However, both patients reported asthenia, hair fallout, and edema, and one also reported diarrhea, but none was feverish. Their respective albuminemias were of 24 and 23 g/l. A respiratory hydrogen test suggested bacterial hyperproliferation. Thirty days after ciprofloxacin and tetracyclin treatments, they showed improved albumin levels and nutritional states, both confirmed by results of hydrogen breath tests. Bacterial overgrowth is an important complication that can compromise clinical evolution of patients submitted to intestinal surgery like gastroplasty with Y-Roux anastomosis. In cases of clinical suspicion or a confirmed diagnosis, adequate antibiotics, sometimes requiring to be cyclically repeated, should be administered.
Resumo:
Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.
Resumo:
Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved
Resumo:
Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.
Resumo:
Objectives: This study compared the reliability and fracture patterns of zirconia cores veneered with pressable porcelain submitted to either axial or off-axis sliding contact fatigue. Methods: Forty-two Y-TZP plates (12 mm x 12 mm x 0.5 mm) veneered with pressable porcelain (12 mm x 12 mm x 1.2 mm) and adhesively luted to water aged composite resin blocks (12 mm x 12 mm x 4 mm) were stored in water at least 7 days prior to testing. Profiles for step-stress fatigue (ratio 3:2:1) were determined from single load to fracture tests (n = 3). Fatigue loading was delivered on specimen either on axial (n = 18) or off-axis 30 degrees angulation (n = 18) to simulate posterior tooth cusp inclination creating a 0.7 mm slide. Single load and fatigue tests utilized a 6.25 mm diameter WC indenter. Specimens were inspected by means of polarized-light microscope and SEM. Use level probability Weibull curves were plotted with 2-sided 90% confidence bounds (CB) and reliability for missions of 50,000 cycles at 200 N (90% CB) were calculated. Results: The calculated Weibull Beta was 3.34 and 2.47 for axial and off-axis groups, respectively, indicating that fatigue accelerated failure in both loading modes. The reliability data for a mission of 50,000 cycles at 200 N load with 90% CB indicates no difference between loading groups. Deep penetrating cone cracks reaching the core-veneer interface were observed in both groups. Partial cones due to the sliding component were observed along with the cone cracking for the off-axis group. No Y-TZP core fractures were observed. Conclusions: Reliability was not significantly different between axial and off-axis mouth-motion fatigued pressed over Y-TZP cores, but incorporation of sliding resulted in more aggressive damage on the veneer. (C) 2009 Elsevier Ltd. All rights reserved.