92 resultados para Inspiratory resistive load testing
Resumo:
Background. Lymphocyte proliferation testing (LPT) has some advantages over patch testing to diagnose allergic contact dermatitis. It is harmless, objective and can be used in clinical situations where patch testing is not recommended. Unfortunately, significant success has only been achieved with nickel. There are few studies on chromium LPT and they were performed with different methods, leading to inconsistent results. Methods. To determine the best parameters for chromium LPT, we tested 20 patients with allergic contact dermatitis to the metal and 20 controls, using various protocols. Results. The best sensitivity and specificity ratios were achieved with 6-day cultures stimulated with a range from 7.5 x 10(-4) to 5 x 10(-3) mol/L of nonfiltered chromium chloride solutions. The sensitivity, specificity and accuracy values found within this range were 65%, 95% and 80%, respectively. Conclusion. Further investigation is necessary to achieve better sensitivity values.
Resumo:
Background: Patients with idiopathic pulmonary fibrosis (IPF) present an important ventilatory (imitation reducing their exercise capacity. Non-invasive ventilatory support has been shown to improve exercise capacity in patients with obstructive diseases; however, its effect on IPF patients remains unknown. Objective: The present study assessed the effect of ventilatory support using proportional, assist ventilation (PAV) on exercise capacity in patients with IPF. Methods: Ten patients (61.2 +/- 9.2 year-old) were submitted to a cardiopulmonary exercise testing, plethysmography and three submaximal. exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Submaximal tests were performed randomly and exercise capacity, cardiovascular and ventilatory response as well as breathlessness subjective perception were evaluated. Lactate plasmatic levels were obtained before and after submaximal. exercise. Results: Our data show that patients presented a limited exercise capacity (9.7 +/- 3.8 mL O(2)/kg/min). Submaximal. test was increased in patients with PAV compared with CPAP and without ventilatory support (respectively, 11.1 +/- 8.8 min, 5.6 +/- 4.7 and 4.5 +/- 3.8 min; p < 0.05). An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV (p < 0.05). IPF patients performing submaximal exercise with PAV also presented a lower heart rate during exercise, although systolic and diastolic pressures were not different among submaximal tests. Our results suggest that PAV can increase exercise tolerance and decrease dyspnoea and cardiac effort in patients with idiopathic pulmonary fibrosis. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Fuzzy Bayesian tests were performed to evaluate whether the mother`s seroprevalence and children`s seroconversion to measles vaccine could be considered as ""high"" or ""low"". The results of the tests were aggregated into a fuzzy rule-based model structure, which would allow an expert to influence the model results. The linguistic model was developed considering four input variables. As the model output, we obtain the recommended age-specific vaccine coverage. The inputs of the fuzzy rules are fuzzy sets and the outputs are constant functions, performing the simplest Takagi-Sugeno-Kang model. This fuzzy approach is compared to a classical one, where the classical Bayes test was performed. Although the fuzzy and classical performances were similar, the fuzzy approach was more detailed and revealed important differences. In addition to taking into account subjective information in the form of fuzzy hypotheses it can be intuitively grasped by the decision maker. Finally, we show that the Bayesian test of fuzzy hypotheses is an interesting approach from the theoretical point of view, in the sense that it combines two complementary areas of investigation, normally seen as competitive. (C) 2007 IMACS. Published by Elsevier B.V. All rights reserved.
Resumo:
To evaluate the effects of frequency and inspiratory plateau pressure (Pplat) during recruitment manoeuvres (RMs) on lung and distal organs in acute lung injury (ALI). We studied paraquat-induced ALI rats. At 24 h, rats were anesthetized and RMs were applied using continuous positive airway pressure (CPAP, 40 cmH(2)O/40 s) or three-different sigh strategies: (a) 180 sighs/h and Pplat = 40 cmH(2)O (S180/40), (b) 10 sighs/h and Pplat = 40 cmH(2)O (S10/40), and (c) 10 sighs/h and Pplat = 20 cmH(2)O (S10/20). S180/40 yielded alveolar hyperinflation and increased lung and kidney epithelial cell apoptosis as well as type III procollagen (PCIII) mRNA expression. S10/40 resulted in a reduction in epithelial cell apoptosis and PCIII expression. Static elastance and alveolar collapse were higher in S10/20 than S10/40. The reduction in sigh frequency led to a protective effect on lung and distal organs, while the combination with reduced Pplat worsened lung mechanics and histology.
Resumo:
Objective: Uncertainties about the numerous degrees of freedom in ventilator settings leave many unanswered questions about the biophysical determinants of lung injury. We investigated whether mechanical ventilation with high air flow could yield lung mechanical stress even in normal animals. Design. Prospective, randomized, controlled experimental study. Setting: University research laboratory. Subjects. Thirty normal male Wistar rats (180-230 g). Interventions: Rats were ventilated for 2 hrs with tidal volume of 10 mL/kg and either with normal inspiratory air flow (V`) of 10 mL/s (F10) or high V` of 30 mL/s (F30). In the control group, animals did not undergo mechanical ventilation. Because high flow led to elevated respiratory rate (200 breaths/min) and airway peak inspiratory pressure (PIP,aw = 17 cm H2O), two additional groups were established to rule out the potential contribution of these variables: a) normal respiratory rate = 100 breaths/min and V` = 30 mL/sec; and b) PIP,aw = 17 cm H2O and V` 10 mL/sec. Measurements and Main Results: Lung mechanics and histology (light and electron microscopy), arterial blood gas analysis, and type III procollagen messenger RNA expression in lung tissue were analyzed. Ultrastructural microscopy was similar in control and F10 groups. High air flow led to increased lung plateau and peak pressures, hypoxemia, alveolar hyperinflation and collapse, pulmonary neutrophilic infiltration, and augmented type III procollagen messenger RNA expression compared with control rats. The reduction of respiratory rate did not modify the morphofunctional behavior observed in the presence of increased air flow. Even though the increase in peak pressure yielded mechanical and histologic changes, type III procollagen messenger RNA expression remained unaltered. Conclusions: Ventilation with high inspiratory air flow may lead to high tensile and shear stresses resulting in lung functional and morphologic compromise and elevation of type III procollagen messenger RNA expression.
Resumo:
Background: Helicobacter pylori ClariRes assay is a novel commercially available real-time PCR assay allowing H. pylori detection and clarithromycin susceptibility testing in either gastric biopsy or stool specimens. Objective: The aim of this study was to validate the novel biprobe real-time assay in stool specimens from 217 dyspeptic children. Methods: DNA from gastric biopsies and stool specimens were obtained and submitted to the biprobe real time assay for H. pylori detection and clarithromycin susceptibility testing. Results: The sensitivity, specificity, and test accuracy were 69, 100 and 93.9% for the detection of H. pylori infection and 83.3, 100 and 95.6%, for detection of clarithromycin resistance. Conclusion: This assay proved to be appropriate for H. pylori clarithromycin susceptibility testing, particularly in children populations where a high prevalence of clarithromycin-resistant strains is suspected.
Resumo:
Wastewater control at storage terminals of liquid chemical products in bulk is very difficult because of the variety of products handled in the facilities generating effluents of variable composition. The main objective of this work was to verify if the Vibrio fischeri acute toxicity test could be routinely included in the wastewater management of those facilities along with physical and chemical analysis in order to evaluate and improve the quality of the generated effluents. The study was performed in two phases before and after the implementation of better operational practices/treatment technologies. Chemical oxygen demand (COD) and toxicity of treated effluents did not correlate showing that effluents with low COD contain toxic substances and non-biodegradable organic matter, which may be not degraded when discharged into the aquatic environment. Segregation of influents or pre-treatment based on toxicity results and biodegradability index were implemented in the facilities generating significant improvements in the quality of final effluents with reduction of Biochemical oxygen demand (BOD) and toxicity. The integration of physical and chemical analysis with the V.fischeri toxicity test turned out to be an excellent tool for wastewater management in chemical terminals allowing rapid decision making for pollution control and prevention measures. Reuse of rain water was also proposed and when implemented by the facilities resulted in economical and environmental benefits. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Although human T-cell lymphotropic virus type 2 (HTLV-2) is considered of low pathogenicity, serological diagnosis is important for counseling and monitoring. The confirmatory tests most used are Western blot (WB) and PCR. However, in high-risk populations, about 50% of the indeterminate WB were HTLV-2 positives by PCR. The insensitivity of the WB might be due to the use of recombinant proteins of strains that do not circulate in our country. Another possibility may be a high level of immunosuppression, which could lead to low production of virus, resulting in low stimulation of antibody. We found one mutation, proline to serine in the envelope region in the position 184, presented at least 1/3 of the samples, independent the indeterminate WB profile. In conclusion, we found no correlation of immune state, HTLV-2 proviral load, or env diversity in the K55 region and WB indeterminate results. We believe that the only WB kit available in the market is probably more accurate to detect HTLV-1 antibodies, and some improvement for HTLV-2 detection should be done in the future, especially among high-risk population. J. Med. Virol. 82:837-842,2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
Background: Many clinical studies have suggested a beneficial effect of GB virus type C (GBV-C) on the course of HIV-1 infection, but the mechanisms involved in such amelioration are not clear. As recent evidence has implicated cellular activation in HIV-1 pathogenesis, we investigated the effect of GBV-C viremia on T-cell activation in early HIV-1 infection. Methods: Forty-eight recently infected HIV-1 patients (23 GBV-C viremic) were evaluated for T-cell counts, expanded immunophenotyping GBV-C RNA detection, and HIV-1 viral load. Nonparametric univariate and multivariate analyses were carried out to identify variables associated with cellular activation, including GBV-C status, HIV-1 viral load, T lymphocyte counts, and CD38 and chemokine (C-C motif) receptor 5 (CCR5) surface expression. Finding: We not only confirmed the positive correlation between HIV-1 viral load and the percentage of T cells positive for CD38(+)CD8(+) but also observed that GBV-C viremic patients had a lower percentage of T cells positive for CD38(+)CD4(+), CD38(+)CD8(+), CCR5(+)CD4(+), and CCR5(+)CD8(+) compared with HIV-1-infected patients who were not GBV-C viremic. In regression models, GBV-C RNA(+) status was associated with a reduction in the CD38 on CD4(+) or CD8(+) T cells and CCR5(+) on CD8(+) T cells, independent of the HIV-1 viral load or CD4(+) and CD8(+) T-cell counts. These results were also supported by the lower expression of CD69 and CD25 in GBV-C viremic patients. Interpretation: The association between GBV-C replication and lower T-cell activation may be a key mechanism involved in the protection conferred by this virus against HIV-1 disease progression to immunodeficiency in HIV-1-infected patients. (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins
Resumo:
STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To evaluate the effect of low-intensity therapeutic ultrasound on the murine calcaneus tendon healing process. BACKGROUND: Therapeutic ultrasound promotes formation and maturation of scar tissue. METHODS: Calcaneus tendon tenotomy and tenorrhaphy was performed on 28 Wistar rats. After the procedure, the animals were randomly divided into 2 groups. The animals in the experimental group received a 5-minute ultrasound application, once a day, at a frequency of 1 MHz, a spatial average temporal average intensity of 0.1 W/cm(2), and a spatial average intensity of 0.52 W/cm(2) at a 16-Hz frequency pulse mode (duty cycle, 20%). Data for the injured side were normalized in relation to the data from the contralateral healthy calcaneus tendon (relative values). The animals in the control group received sham treatment. After a 28-day treatment period, the animals were sacrificed and their tendons surgically removed and subjected to mechanical stress testing. The parameters analyzed were cross-sectional area (mm(2)), ultimate load (N), tensile strength (MPa), and energy absorption (mJ). RESULTS: A significant difference between groups was found for the relative values of ultimate load and tensile strength. The mean +/- SD ultimate load of the control group was -3.5% +/- 32.2% compared to 33.3% +/- 26.8% for the experimental group (P = .005). The mean tensile strength of the control group was -47.7% +/- 19.5% compared to -28.1% +/- 24.1% for the experimental group (P = .019). No significant difference was found in cross-sectional area and energy absorption. CONCLUSION: Low-intensity pulsed ultrasound produced by a conventional therapeutic ultrasound unit can positively influence the calcaneus tendon healing process in rats. J Ort hop Sports Phys Ther 2011;41(7):526-531, Epub 2 February 2011. doi:10.2519/jospt.2011.3468
Resumo:
To examine abnormal patterns of frontal cortical-subcortical activity in response to emotional stimuli in euthymic individuals with bipolar disorder type I in order to identify trait-like, pathophysiologic mechanisms of the disorder. We examined potential confounding effects of total psychotropic medication load and illness variables upon neural abnormalities. We analyzed neural activity in 19 euthymic bipolar and 24 healthy individuals to mild and intense happy, fearful and neutral faces. Relative to healthy individuals, bipolar subjects had significantly increased left striatal activity in response to mild happy faces (p < 0.05, corrected), decreased right dorsolateral prefrontal cortical (DLPFC) activity in response to neutral, mild and intense happy faces, and decreased left DLPFC activity in response to neutral, mild and intense fearful faces (p < 0.05, corrected). Bipolar and healthy individuals did not differ in amygdala activity in response to either emotion. In bipolar individuals, there was no significant association between medication load and abnormal activity in these regions, but a negative relationship between age of illness onset and amygdala activity in response to mild fearful faces (p = 0.007). Relative to those without comorbidities, bipolar individuals with comorbidities showed a trend increase in left striatal activity in response to mild happy faces. Abnormally increased striatal activity in response to potentially rewarding stimuli and decreased DLPFC activity in response to other emotionally salient stimuli may underlie mood instabilities in euthymic bipolar individuals, and are more apparent in those with comorbid diagnoses. No relationship between medication load and abnormal neural activity in bipolar individuals suggests that our findings may reflect pathophysiologic mechanisms of the illness rather than medication confounds. Future studies should examine whether this pattern of abnormal neural activity could distinguish bipolar from unipolar depression.
Resumo:
Background: HTLV-2 infections are almost always asymptomatic, and diseases associated with the infection are rarely reported. Little information is available on the relationship between HTLV-2 proviral load and gender or expression of disease, especially among patients with HlV-1 co-infection. Methods: We studied 77 HTLV-2-infected subjects followed in our clinic for the last 9 years; 53 (69%) of them were co-infected with HIV-1. HTLV-2 DNA proviral load (PVL) was measured by real time PCR, a test with a sensitivity of 10 in 10(4) PBMCs. Results: Six of 53 HTLV-2/HIV-1 cases had a myelopathy (all of them had undetectable PVL of HTLV-2). Only 3 of 35 women (2 out of 3 co-infected with HIV) had a detectable PVL, whereas 10 of 42 men had a detectable PVL. Regardless of their HIV status women had significantly lower PVL than men (10 vs. 43 CopieS/10(4) PBMCs, p < 0.05). Conclusions: We noticed the occurrence of myelopathy in HTLV-2/HIV-1 co-infected patients, with undetectable HTLV-2 viral load. There was a sex difference in viral load for HTLV-2, what may be the result in mode of transmission or acquisition of the virus. (c) 2008 Elsevier B. V. All rights reserved.
Resumo:
Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
BACKGROUND: Previous studies have shown positive effects from noninvasive ventilation (NIV) or supplemental oxygen on exercise capacity in patients with COPD. However, the best adjunct for promoting physiologic adaptations to physical training in patients with severe COPD remains to be investigated. METHODS: Twenty-eight patients (mean +/- SD age 68 +/- 7 y) with stable COPD (FEV(1) 34 +/- 9% of predicted) undergoing an exercise training program were randomized to either NIV (n = 14) or supplemental oxygen (n = 14) during group training to maintain peripheral oxygen saturation (S(pO2)) >= 90%. Physical training consisted of treadmill walking (at 70% of maximal speed) 3 times a week, for 6 weeks. Patients were assessed at baseline and after 6 weeks. Assessments included physiological adaptations during incremental exercise testing (ratio of lactate concentration to walk speed, oxygen uptake [(V) over dot(O2)], and dyspnea), exercise tolerance during 6-min walk test, leg fatigue, maximum inspiratory pressure, and health-related quality of life. RESULTS: Two patients in each group dropped out due to COPD exacerbations and lack of exercise program adherence, and 24 completed the training program. Both groups improved 6-min walk distance, symptoms, and health-related quality of life. However, there were significant differences between the NIV and supplemental-oxygen groups in lactate/speed ratio (33% vs -4%), maximum inspiratory pressure (80% vs 23%), 6-min walk distance (122 m vs 47 m), and leg fatigue (25% vs 11%). In addition, changes in S(pO2)/speed, (V) over dot(O2), and dyspnea were greater with NIV than with supplemental-oxygen. CONCLUSIONS: NIV alone is better than supplemental oxygen alone in promoting beneficial physiologic adaptations to physical exercise in patients with severe COPD.
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.