82 resultados para Equipment Expanders


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solar energy powered failing film evaporator with film promoter was developed for concentrating diluted solutions (industrial effluents). The procedure proposed here does not emit CO(2), making it a viable alternative to the method of concentrating solutions that uses vapor as a heat source and releases CO(2) from burning fuel oil in a furnace, in direct opposition to the carbon reduction agreement established by the Kyoto protocol. This novel device consists of the following components: a flat plate solar collector with adjustable inclination, a film promoter (adhering to the collector), a liquid distributor, a concentrate collector. and accessories. The evaporation rate of the device was found to be affected both by the inclination of the collector and by the feed flow. The meteorological variables cannot be controlled, but were monitored constantly to ascertain the behavior of the equipment in response to the variations occurring throughout the day. Higher efficiencies were attained when the inclination of the collector was adjusted monthly, showing up to 36.4% higher values than when the collector remained in a fixed position. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A modified cyclone washer was designed, fabricated, and its collection efficiency evaluated. This equipment consists of an American-type cyclone separator with a triple cone and a spray nozzle was introduced into its cylindrical body. The study consisted of an experimental evaluation of the operating conditions at ambient and higher than ambient temperatures, varying chimney height and water flow rate, with the purpose of humidifying the dust. The collection efficiency of the cyclone washer was evaluated particles of micronized quartz with an average diameter of 7.48 mu m and a density of 2.650 g/cm(3). The amount of particles varied from 20-100 mg/m(3) of air. An average efficiency of 97.07 +/- 1.03 % was obtained with four spray nozzles, a chimney height of 0.645 m and 0.358 m(3)/s of gas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design, construction, and characterization of a portable opto-coupled potentiostat are presented. The potentiostat is battery-powered, managed by a microcontroller, which implements cyclic voltammetry (CV) using suitable sensor electrodes. Its opto-coupling permits a wide range of current measurements, varying from mA to nA. Two software interfaces were developed to perform the CV measurement: a virtual instrument for a personal computer (PC) and a C-base interface for personal digital assistant (PDA). The potentiostat has been evaluated by detection of potassium ferrocyanide in KCl medium, both with macro and microelectrodes. There was good agreement between the instrumental results and those from commercial equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unsaturated hydraulic conductivity of an Oxisol, using a neutron probe. The objective of this study was to determine the unsaturated hydraulic conductivity, using a neutron probe, of a clay sandy Oxisol. The Study was carried out in the city of Piracicaba, kite of Sao Paulo, Brazil (22 degrees 42` 43.3 `` S, 47 degrees`37` 10.4 `` W, 546 m). The dimensions of the experimental plot were 45 In x 15 m, in which 40 aluminum tubes were installed in order to access a neutron probe to measure the soil water content at the depths of 0.2, 0.4, 0.6, 0.8 and 1.0 m and, then, calculate the soil water storage of the 0 - 1.0 m soil layer. The distribution of these tubes was made in grids of four columns by ten rows in spacing of 5 x 5 m. The K(theta) functions were determined in the 40 points from regression analyses of theta as function Int and h(z) as a function of Int, being K the hydraulic conductivity, theta the volumetric soil water content, h(z) the soil water storage in the 0 - Z m layer, and t the soil water redistribution time. The neutron probe proved to be an efficient equipment in determining soil water contents, in the instantaneous profile method for determination of the K(theta) function in homogeneous soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to the rapid depletion of water resources, water must be used more efficiently in agriculture to maintain current levels of yield in irrigated areas. The efficiency of irrigation systems can be increased by adjusting the amount of water applied to specific conditions of soil and crop, which may vary in a field. Taking into account spatial and temporal variability, it is evident that an equipment capable of providing different irrigation levels is necessary to meet the water requirement of the soil. This work aims to develop and evaluate a flow rate sprinkler to be used in center pivots or linear moving irrigation systems, with potential for utilization in irrigation scheduling. A prototype was developed by duplicating its calibrations, and discharge coefficient adjustment was carried out in the laboratory. To predict the flow rate, a successful model that represented the operation of the flow rate sprinkler was established. The calibration of the flow rate sprinkler prototype showed satisfactory statistical and technical results. Automation of the prototype was achieved by driving a step motor using communication from the parallel port of a microcomputer, which was controlled by a software developed for this purpose. The results were satisfactory and technically feasible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate how beaker size, basket assembly, use of disk, and immersion medium impact the disintegration time of dietary supplements. The disintegration times were determined for five tablet and two capsule products. A two-station disintegration tester was used with Apparatus A or Apparatus B as described in the United States Pharmacopeia (USP) chapters, < 701 > and < 2040 >. Two beakers complying with the harmonized specifications were used, one with a volume of 1,000 mL and one with a 1,500-mL volume. The disintegration data were analyzed using ANOVA for the following factors: beaker size, equipment (App A and B) and condition (with/without disk). Two tablet products were not sensitive to any changes in the test conditions or equipment configurations. One product was only partially sensitive to the test conditions. The other products showed impact on the disintegration time for all test conditions. The results revealed that these tablet products might pass or fail current USP disintegration requirements depending on the equipment configuration. Similar results were obtained for the two investigated capsule formulations. One product might fail current USP disintegration requirements if the large beaker was used, but might pass the disintegration requirements when the small beaker was used. Hydroxy propyl methyl cellulose capsules were mostly influenced if sodium instead of a potassium buffer was used as the immersion medium. The results demonstrate that the current harmonized ICH specifications for the disintegration test are insufficient to make the disintegration test into reliable test for dietary supplements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents an evaluation of the effects of the spouted bed design and operating conditions on system fluiddynamics and process performance during enteric coating of hard gelatine capsules. The design parameters studied were the column diameter (150 mm and 200 mm), the included angle of the conical base, gamma (60 degrees or 40 degrees) and the presence or absence of a Venturi inserted before the inlet air orifice. The process variables studied were the ratio between the feed flow rate of the coating suspension to the spouting gas flow rate (W(s)/W(g)), the mass of capsules loaded to the equipment (M(0)), and the ratio between the Spouting gas flow rate to the gas flow rate at minimum spouting condition (Q/Q(ms)). The response variables were the rate of increase of the capsules mass (K(1)), and the adhesion efficiency (eta). The linear regression equation for the dependent variable K, in terms of the independent variables adequately described the process with an r(2) value of 0.872. Analysis of variance (ANOVA) revealed that increasing of W(s)/W(g), Q/Q(ms) and gamma significantly increased the adhesion efficiency. Adhesion efficiencies higher than 90% were achieved by selecting precise coating conditions, indicating the feasibility of the process for coating of hard gelatine capsules. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cyclodextrins (CDs) are annular oligosaccharides containing 6-12 glucose unities joined together by alpha-1,4 bonds. They have a conical-truncated shape with a lipophilic cavity in which different molecules can be included resulting in a stable inclusion complex. The cyclodextrins have been widely applied in pharmaceutical technology with the objective of increasing the solubility, stability and bioavailability of drugs in different pharmaceutical dosage forms, such as tablets. In order to obtain beta-CD tablets, liquid dispersions of drug/beta-CD are usually submitted to different drying processes, like spray-drying, freeze-drying or slow evaporation, being this dry material added to a number of excipients. However, such drying processes can generate particulate materials showing problems of flow and compressibility, needing their conversion into granulates by means of wetting with granulation liquid followed by additional drying. In this work, the main objective was to evaluate the preparation of tablets without the need of this additional drying step. For this purpose an aqueous dispersion containing acetaminophen/beta-CD complex and cornstarch was dried using a spouted bed and the obtained granules were compressed in tablets. Acetaminophen was used as model drug due to its low water solubility and the inexpensive and widely available cornstarch was chosen as excipient. Acetaminophen powder was added into a beta-cyclodextrin solution prepared in distilled water at 70 degrees C. Stirring was kept until this dispersion cooled to room temperature. Then cornstarch was added and the resulting dispersion was dried in spouted bed equipment. This material was compressed into tablets using an Erweka Korsh EKO tablet machine. This innovative approach allowed the tablets preparation process to be carried out with fewer steps and represents a technological reliable strategy to produce beta-cyclodextrin inclusion complexes tablets. (C) 2010 Elsevier By. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New differential linear coherent scattering coefficient, mu(CS), data for four biological tissue types (fat pork, tendon chicken, adipose and fibroglandular human breast tissues) covering a large momentum transfer interval (0.07 <= q <= 70.5 nm(-1)), resulted from combining WAXS and SAXS data, are presented in order to emphasize the need to update the default data-base by including the molecular interference and the large-scale arrangements effect. The results showed that the differential linear coherent scattering coefficient demonstrates influence of the large-scale arrangement, mainly due to collagen fibrils for tendon chicken and fibroglandular breast samples, and triacylglycerides for fat pork and adipose breast samples at low momentum transfer region. While, at high momentum transfer, the mu(CS) reflects effects of molecular interference related to water for tendon chicken and fibroglandular samples and, fatty acids for fat pork and adipose samples. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To standardize an experimental model of spinal cord injury in Wistar rats, computerized weight fall impact equipment were used and the parameters were used determined by the multicenter animal spinal cord injury study - MASCIS. Methods: Thirty rats were used, with age varying between 20 and 25 weeks, and weight ranging from 200 to 300g for females, and from 232 to 430g for males. The impacts were done with weights of 10g starting from 12.5, 25 and 50 mm of height, and the impact speed and compression coefficient were obtained. The impact occurred on the surface of the spinal cord at the level of the tenth thoracic vertebra after laminectomy. Vital signs were monitored and gas analysis was made before and after the spinal cord injury. The lesion volume was evaluated by the quantitative analysis of sodium and potassium ions. Results: Statistically significant correlations were verified among the lesion volume and the mechanical parameters. The lesion volume caused by the fall from 50mm height was superior to that of the 12.5 and 25mm, which didn`t differ from each other. Conclusion: The model demonstrated itself to be effective and capable of generating standard spinal cord injuries on Wistar rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There are occupational risks inherent to the activities of professional hairdressers, which are not frequently studied, and therefore not considered in the formulation of health policies for this group. Aims To verify the prevalence of work-related musculoskeletal disorders (WRMDs) in hairdressers through symptom reports, to characterize the most frequently affected anatomical parts and to identify and analyse risk factors of WRMDs in hairdressing. Methods A cross-sectional epidemiological study of 220 hairdressers from beauty parlours in Sao Paulo (Brazil) was carried out. Each hairdresser completed a self-administered questionnaire which included information on socio-demographic characteristics, working conditions and health-related musculoskeletal system complaints. Ergonomic analyses were also performed in six parlours. Results The prevalence of WRMDs was 71%. Risk factors were associated with psychosocial factors and factors related to discomfort and work fatigue such as lack of acknowledgement of work and uncomfortable posture at work [odds ratio (OR) = 3.54; 95% confidence interval (CI) 1.51-8.30], not feeling comfortable with body/neck/shoulders while working (OR = 2.78; 95% CI 1.40-5.54) and having > 15 years of professional activity (OR = 3.04; 95% CI 1.17-7.91). Conclusion Occupational risk factors associated with the development of WRMDs in hairdressers are related to biomechanical, organizational and psychosocial work factors. The high prevalence of WRMDs found highlights the importance of disseminating recommendations for prevention of symptoms with regards to the provision of suitable furniture, equipment and work tools, environmental conditions, size of workplace, work organization and psychosocial work factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fleet enemas are hypertonic solutions with an osmotic action and a high concentration of phosphate. When retained in the human body they have a great toxic potential, causing severe hydro-electrolyte disorders in children, especially in newborns. We report the case of a previously healthy 8-day-old newborn who needed neonatal intensive care treatment after the inadvertent administration of an osmotically active hypertonic phosphate enema. Taking into account that phosphate removal by peritoneal dialysis (PD) strongly depends on total dialysate turnover, we chose continuous flow PD (CFPD) as the treatment option, with a successful outcome. Clinical experience with this dialytic modality is limited to a few case reports in pediatric and adult patients. To the best of our knowledge, we report here the first description of CFPD in the setting of acute phosphate nephropathy in the neonatal period. The modality of PD described here has potential as an alternative management option as it is a highly efficient, methodologically simple, and low-cost method without any need for sophisticated equipment. Physicians and parents should be aware of the adverse effects of a hypertonic phosphate enema and should never use these medications in infants and newborns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our study aims to investigate changes in electrocortical activity by observing the variations in absolute theta power in the primary somatomotor and parietal regions of the brain under three different electrical stimulation conditions: control group (without stimulation), group 24 (24 trials of stimulation) and group 36 (36 trials of stimulation). Thus, our hypothesis is that the application of different patterns of electrical stimulation will promote different states of habituation in these regions. The sample was composed of 24 healthy (absence of mental and physical impairments) students (14 male and 10 female), with ages varying from 25 to 40 years old (32.5 +/- 7.5), who are right-handed (Edinburgh Inventory). The subjects were randomly distributed into three groups: control (n = 8), G24 (n = 8) and G36 (n = 8). We use the Functional electrical stimulation (FES) equipment (NeuroCompact-2462) to stimulate the right index finger extensor muscle, while the electroencephalographic signal was simultaneously recorded. We found an interaction between condition and block factors for the C3 and P3 electrode, a condition and block main effects for the C4 electrode, and a condition main effect for the P4 electrode. Our results support the hypothesis that electrical stimulation promotes neurophysiological changes. It appears that stimulus adaptation (accommodation) of specific circuits can strengthen the brain`s ability to distinguish between and respond to such stimuli over time. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Design: Experimental bench study. Setting: The respiratory care laboratory of a university-affiliated teaching hospital. Subject: A computerized mechanical lung model, the IngMar ASL5000. Interventions: Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Measurements and main results: Performance varied widely among ventilators. Mean inspiratory trigger time was < 100 ms for only half of the tested ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Conclusions: Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To examine the changes in slow (8-10 Hz)and fast (10-12 Hz) alpha bands of EEG in three groups of subjects submitted to different amounts of functional electrostimulation (FES). Our hypothesis is that different amounts of electrostimulation may cause different patterns of activation in the sensorimotor cortex. In particular, we expect to see an increase in alpha power due to habituation effects. We examine the two bands comprised by alpha rhythm (i.e., slow and fast alpha), since these two sub-rhythms are related to distinct aspects: general energy demands and specific motor aspects, respectively. Methods: The sample was composed of 27 students, both sexes, aging between 25 and 40 years old. The subjects were randomly distributed in three groups: control (n = 9), G24 (n = 9) and G36 (n = 9). A FES equipment (Neuro Compact-2462) was used to stimulate the right index finger extension. Simultaneously, the electroencephalographic signal was acquired. We investigated the absolute power in slow and fast alpha bands in the sensorimotor cortex. Results: The G36 indicated a significant increasing in absolute power values in lower and higher alpha components, respectively, when compared with the control group. Particularly, in the following regions: pre-motor cortex and primary motor cortex. Discussion: FES seems to promote cortical adaptations that are similar to those observed when someone learns a procedural task. FES application in the G36 was more effective in promoting such neural changes. The lower and higher components of alpha rhythms behave differently in their topographical distribution during FES application. These results suggest a somatotopic organization in primary motor cortex which can be represented by the fast alpha component. (C) 2008 Elsevier Ireland Ltd. All rights reserved.