70 resultados para Digital History
Resumo:
Objective To describe the natural history of fetuses presenting with pleural effusion. Methods Between January 2005 and December 2009 all fetuses diagnosed with pleural effusion were followed up. Fetuses were divided into three groups: I, isolated pleural effusion; II, associated structural anomalies but normal karyotype; and III, chromosomal anomalies. Univariate and multivariate analyses were performed to determine the association between prenatal ultrasound findings and perinatal death. Results Fifty-six fetuses were included in the study. Associated structural or chromosomal anomalies occurred in 75.0% (42/56) of cases. Bilateral pleural effusion and fetal hydrops were associated with each other (p < 0.01) and with perinatal death (p < 0.05). Multivariate analysis indicated that only the presence of associated abnormalities was a statistical determinant of perinatal death (OR, 3.56; 95% CI, 1.48-5.64; p < 0.01). Conclusion Fetal pleural effusion is often associated with other abnormalities, and this association has poor perinatal outcome. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.
Resumo:
Background. The natural history of congenital cytomegalovirus (CMV) infection is scarcely known in populations with high maternal CMV seroprevalence. This study evaluated the birth prevalence, clinical findings at birth, and hearing outcome in CMV-infected children from such a population. Methods. Consecutively born infants were screened for the presence of CMV in urine and/or saliva specimens during the first 2 weeks after birth. Neonatal clinical findings were recorded, and CMV-infected children were tested to document hearing function during follow-up. A subset of mothers of CMV-infected infants were prenatally tested for the presence of anti-CMV immunoglobulin G antibodies. Results. Congenital CMV infection was confirmed in 87 (1.08%; 95% confidence interval [CI], 0.86%-1.33%) of 8047 infants. Seven infants (8.1%; 95% CI, 3.3%-15.9%) had at least 1 clinical finding suggestive of CMV infection, and 4 (4.6%; 95% CI, 1.3%-11.3%) had 13 findings of systemic disease. Sensorineural hearing loss was found in 5 (8.6%; 95% CI, 2.9%-19.0%) of 58 children tested at a median age of 21 months. Bilateral profound hearing loss was observed in 2 children, and the hearing threshold was 160 decibels in all 5 children with hearing loss, including 2 children born to mothers with probable nonprimary CMV infection. Conclusions. The results of this large newborn screening study in a population with high CMV seroimmunity provide additional evidence that congenital CMV disease occurs in populations with high seroprevalence rates, with a similar incidence of CMV-related hearing loss to that reported in the offspring of women from populations in developed countries with lower rates of seroimmunity to CMV.
Resumo:
The civil-military dictatorship, which took power in 1964, influenced the daily activities of schools and teachers. Many transformations occurred during this period, including the new legislation enacted under Law 5692/71 and changes which occurred due to the vigilance which teachers felt when working. The memories analyzed here of teachers from public schools in Sao Paulo show different perceptions of this surveillance, involving various forms of acceptance or resistance. The purpose of this article is to show that although there was no direct repression of schools, unlike in the universities, teachers at the elementary school also felt constrained and this can be seen in their educational practices and teaching concepts.
Resumo:
Although dogs are considered to be the principal transmitter of rabies in Brazil, dog rabies had never been recorded in South America before European colonization. In order to investigate the evolutionary history of dog rabies virus (RABV) in Brazil, we performed a phylogenetic analysis of carnivore RABV isolates from around the world and estimated the divergence times for dog RABV in Brazil. Our estimate for the time of introduction of dog RABV into Brazil was the late-19th to early-20th century, which was later than the colonization period but corresponded to a period of increased immigration from Europe to Brazil. In addition, dog RABVs appeared to have spread to indigenous animals in Brazil during the latter half of the 20th century, when the development and urbanization of Brazil occurred. These results suggest that the movement of rabid dogs, along with human activities since the 19th century, promoted the introduction and expansion of dog RABV in Brazil.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
Objectives: To evaluate the influence of JPEG quality factors 100, 80 and 60 on the reproducibility of identification of cephalometric points on images of lateral cephalograms, compared with the Digital Imaging and Communications in Medicine (DICOM) format. Methods: The sample was composed of 30 images of digital lateral cephalograms obtained from 30 individuals (15 males and 15 females) on a phosphor plate system in DICOM format. The images were converted to JPEG with quality factors 100, 80 and 60 with the aid of software, adding up to 90 images. The 120 images (DICOM, JPEG 100, 80 and 60) were blinded and 12 cephalometric points were identified on each image by three calibrated orthodontists, using the x-y coordinate system, on a cephalometric software. Results: The results revealed that identification of cephalometric points was highly reproducible, except for the point Orbitale (Or) on the x-axis. The different file formats did not present a statistically significant difference. Conclusions: JPEG images of lateral cephalograms with quality factors 100, 80 and 60 did not present alterations in the reproducibility of identification of cephalometric points compared with the DICOM format. Good reproducibility was achieved for the 12 points, except for point Or on the x-axis. Dentomaxillofacial Radiology (2009) 38, 393-400. doi: 10.1259/dmfr/40996636