65 resultados para Array algorithm


Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the key issues in e-learning environments is the possibility of creating and evaluating exercises. However, the lack of tools supporting the authoring and automatic checking of exercises for specifics topics (e.g., geometry) drastically reduces advantages in the use of e-learning environments on a larger scale, as usually happens in Brazil. This paper describes an algorithm, and a tool based on it, designed for the authoring and automatic checking of geometry exercises. The algorithm dynamically compares the distances between the geometric objects of the student`s solution and the template`s solution, provided by the author of the exercise. Each solution is a geometric construction which is considered a function receiving geometric objects (input) and returning other geometric objects (output). Thus, for a given problem, if we know one function (construction) that solves the problem, we can compare it to any other function to check whether they are equivalent or not. Two functions are equivalent if, and only if, they have the same output when the same input is applied. If the student`s solution is equivalent to the template`s solution, then we consider the student`s solution as a correct solution. Our software utility provides both authoring and checking tools to work directly on the Internet, together with learning management systems. These tools are implemented using the dynamic geometry software, iGeom, which has been used in a geometry course since 2004 and has a successful track record in the classroom. Empowered with these new features, iGeom simplifies teachers` tasks, solves non-trivial problems in student solutions and helps to increase student motivation by providing feedback in real time. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given two strings A and B of lengths n(a) and n(b), n(a) <= n(b), respectively, the all-substrings longest common subsequence (ALCS) problem obtains, for every substring B` of B, the length of the longest string that is a subsequence of both A and B. The ALCS problem has many applications, such as finding approximate tandem repeats in strings, solving the circular alignment of two strings and finding the alignment of one string with several others that have a common substring. We present an algorithm to prepare the basic data structure for ALCS queries that takes O(n(a)n(b)) time and O(n(a) + n(b)) space. After this preparation, it is possible to build that allows any LCS length to be retrieved in constant time. Some trade-offs between the space required and a matrix of size O(n(b)(2)) the querying time are discussed. To our knowledge, this is the first algorithm in the literature for the ALCS problem. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel Schiff base-copper(II) complex [Cu(2)L(2)(N(3))(2)](ClO(4))(2) 1, where L = (4-imidazolyl)ethylene-2-amino-1-ethylpyridine (apyhist), containing azide-bridges between adjacent copper ions in a dinuclear arrangement was isolated and characterized both in the solid state and in solution by X-ray crystallography and different spectroscopic techniques. Azide binding constants were estimated from titrations of the precursor [CuL(H(2)O)(2)](2+) solutions with sodium azide, giving rise to the azido-bridged species, [Cu(2)L(2)(N(3))(2)](2+). Raman spectra showed asymmetric stretching band at 2060 cm(-1), indicating the presence of azido ligands with a symmetric mu(1,) (1) binding geometry. EPA spectra, in frozen methanol/water solutions at 77 K, exhibited characteristic features of copper centers in tetragonal pyramidal coordination geometry, exhibiting magnetic interactions between them. Further, in solid state, two different values for magnetic coupling in this species were obtained, J/k = -(5.14 +/- 0.02) cm(-1) attributed to the mu(1, 1) azide-bridge mode, and J`z`/k = -(2.94 +/- 0.11) cm(-1) for the interaction between dinuclear moieties via water/perchorate bridges. Finally, an attempt was made to correlate structure and magnetic data for this dinuclear asymmetric end-on azido bridged-copper(II) 1 complex with those of another correlated dinuclear system, complex [Cu(2)L(2)Cl(2)](ClO(4))(2) 2, containing the same tridentate diimine ligand, but with chloro-bridged groups between the copper centres.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast and robust analytical method for amperometric determination of hydrogen peroxide (H(2)O(2)) based on batch injection analysis (BIA) on an array of gold microelectrodes modified with platinum is proposed. The gold microelectrode array (n = 14) was obtained from electronic chips developed for surface mounted device technology (SMD), whose size offers advantages to adapt them in batch cells. The effect of the dispensing rate, volume injected, distance between the platinum microelectrodes and the pipette tip, as well as the volume of solution in the cell on the analytical response were evaluated. The method allows the H(2)O(2) amperometric determination in the concentration range from 0.8 mu mol L(-1) to 100 mu mol L(-1). The analytical frequency can attain 300 determinations per hour and the detection limit was estimated in 0.34 mu mol L(-1) (3 sigma). The anodic current peaks obtained after a series of 23 successive injections of 50 mu L of 25 mu mol L(-1) H(2)O(2) showed an RSD < 0.9%. To ensure the good selectivity to detect H(2)O(2), its determination was performed in a differential mode, with selective destruction of the H(2)O(2) with catalase in 10 mmol L(-1) phosphate buffer solution. Practical application of the analytical procedure involved H(2)O(2) determination in rainwater of Sao Paulo City. A comparison of the results obtained by the proposed ampermetric method with another one which combines flow injection analysis (FIA) with spectrophotometric detection showed good agreement. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dosing algorithm including genetic (VKORC1 and CYP2C9 genotypes) and nongenetic factors (age, weight, therapeutic indication, and cotreatment with amiodarone or simvastatin) explained 51% of the variance in stable weekly warfarin doses in 390 patients attending an anticoagulant clinic in a Brazilian public hospital. The VKORC1 3673G>A genotype was the most important predictor of warfarin dose, with a partial R(2) value of 23.9%. Replacing the VKORC1 3673G>A genotype with VKORC1 diplotype did not increase the algorithm`s predictive power. We suggest that three other single-nucleotide polymorphisms (SNPs) (5808T>G, 6853G>C, and 9041G>A) that are in strong linkage disequilibrium (LD) with 3673G>A would be equally good predictors of the warfarin dose requirement. The algorithm`s predictive power was similar across the self-identified ""race/color"" subsets. ""Race/color"" was not associated with stable warfarin dose in the multiple regression model, although the required warfarin dose was significantly lower (P = 0.006) in white (29 +/- 13 mg/week, n = 196) than in black patients (35 +/- 15 mg/week, n = 76).