49 resultados para material online


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The arterial pulse pressure variation induced by mechanical ventilation (Delta PP) has been shown to be a predictor of fluid responsiveness. Until now, Delta PP has had to be calculated offline (from a computer recording or a paper printing of the arterial pressure curve), or to be derived from specific cardiac output monitors, limiting the widespread use of this parameter. Recently, a method has been developed for the automatic calculation and real-time monitoring of Delta PP using standard bedside monitors. Whether this method is to predict reliable predictor of fluid responsiveness remains to be determined. METHODS: We conducted a prospective clinical study in 59 mechanically ventilated patients in the postoperative period of cardiac surgery. Patients studied were considered at low risk for complications related to fluid administration (pulmonary artery occlusion pressure <20 mm Hg, left ventricular ejection fraction >= 40%). All patients were instrumented with an arterial line and a pulmonary artery catheter. Cardiac filling pressures and cardiac output were measured before and after intravascular fluid administration (20 mL/kg of lactated Ringer`s solution over 20 min), whereas Delta PP was automatically calculated and continuously monitored. RESULTS: Fluid administration increased cardiac output by at least 15% in 39 patients (66% = responders). Before fluid administration, responders and nonresponders were comparable with regard to right atrial and pulmonary artery occlusion pressures. In contrast, Delta PP was significantly greater in responders than in nonresponders, (17% +/- 3% vs 9% +/- 2%, P < 0.001). The Delta PP cut-off value of 12% allowed identification of responders with a sensitivity of 97% and a specificity of 95%. CONCLUSION: Automatic real-time monitoring of Delta PP is possible using a standard bedside rnonitor and was found to be a reliable method to predict fluid responsiveness after cardiac surgery. Additional studies are needed to determine if this technique can be used to avoid the complications of fluid administration in high-risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Recently, there has been an increase in the incidence of cutaneous leishmaniasis (CL), which represents an important health problem. This increase may be related to the epidemiologic expansion of the infective agent and the increase in tourism in tropical areas. The difficulty in clinical diagnosis, mainly in areas in which CL is not the first consideration of local physicians, has intensified efforts to describe diagnostic tests, which should be specific, sensitive, and practical. Amongst the new tests described are those including nucleic acid amplification (polymerase chain reaction, PCR) and immunohistochemistry (IHC). Methods In this study, we evaluated the sensitivity of a PCR based on small subunit (SSU) ribosomal DNA, in comparison with IHC using Leishmania spp. antibodies, in biopsies embedded in paraffin. Result The results indicated a total sensitivity of 96% (90.9% with PCR and 68.8% with IHC), showing the possibility of using paraffin-embedded biopsies to diagnose CL. Conclusion We propose the use of the two tests together as a routine protocol for diagnosis. This would require the provision of local medical services to perform molecular biology techniques and adequate Leishmania antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Methods: Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 degrees C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, alpha = 0.05). Results: None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. Conclusions: ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. (I Endod 2010;36:1870-1873)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 62-year-old man was referred for routine treatment of hyperplasia of the mucosa in the anterior lower jaw. An oroantral fistula was detected in the right superior alveolar ridge. The patient had no complaints. Plain radiographs showed a radiopaque foreign body in the posterior region associated with opacification of the maxillary sinus. Computed tomography showed the same hyperdense foreign body located in the posterior lower part of the sinus and an abnormal soft tissue mass in the entire right maxillary sinus. When asked about sinusitis, the patient mentioned occasional episodes of pus taste and intermittent crises of headache lasting for one week. The patient has been edentulous for 20 years. Sinus debridement was performed and the oroantral fistula was closed. The clinical suspicion of the presence of zinc oxide-eugenol paste was confirmed by microscopical and chemical analysis. After 6 months of follow-up, the fistula continued to be closed and sinusitis did not recur. This clinical case of maxillary chronic sinusitis illustrates a different odontogenic origin.