70 resultados para electrical grid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-voltage electric injuries have many manifestations, and an important complication is the damage of the central/peripheral nervous system. The purpose of this work was to assess the upper limb dysfunction in patients injured by high-voltage current. The evaluation consisted of analysis of patients` records, cutaneous-sensibility threshold, handgrip and pinch strength and a specific questionnaire about upper limb dysfunctions (DASH) in 18 subjects. All subjects were men; the average age at the time of the injury was 38 years. Of these, 72% changed job/retired after the injury. The current entrance was the hand in 94% and grounding in the lower limb in 78%. The average burned surface area (BSA) was 8.6%. The handgrip strength of the injured limb was reduced (p < 0.05) and so also that of the three pinch types. The relationship between the handgrip strength and the DASH was statistically significant (p < 0.001) as well as the relationship between the three pinch types (p <= 0.02) to the injured limb. The ability to perceive cutaneous touch/pressure was decreased in the burnt hand, principally in the median nerve area. These data indicate a reduction of the hand muscular strength and sensibility, reducing the function of the upper limb in patients who received high-voltage electrical shock. (C) 2008 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The medial prefrontal cortex (MPFC) is involved in cardiovascular control. MPFC electrical stimulation has been reported to cause depressor and bradycardic responses in anesthetized rats. Although the pathway involved is yet unknown, there is evidence indicating the existence of a relay in the lateral hypothalamus (LH). The medial forebrain bundle (MFB) that courses in the lateral portion of the LH carries the vast majority of telencephalic afferent as well efferent projections, including those from the MPFC. To evaluate if the hypotensive pathway originating in the MPFC courses the MFB, we studied the effect of coronal or sagittal knife cuts through the LH and other brain areas on the cardiovascular responses to MPFC electrical stimulation. Knife cuts were performed using blades I to 6 mm wide. Results indicate that the neural pathway descending from the MFB decussates early in the vicinity of MPFC, crossing the midline within the corpus callosurn and yielding two descending pathways that travel rostro-caudally in the lateral portion of the LH, within the MFB. The decussation was confirmed by histological analysis of brain sections processed after the injection of biotinilated dextran amine in the site of the stimulation in the MPFC. Because knife cuts through the LH ipsilateral had minimal effects on the cardiovascular responses and knife cuts performed contralateral to the stimulated MPFC had no effect on the response to MPFC stimulation, data indicate that the contralateral limb of the pathway may be only activated as an alternative pathway when the ipsilateral pathway is blocked. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To assess the safety of transcorneal electrical stimulation (TES) and explore its efficacy in various subjective and objective parameters of visual function in patients with retinitis pigmentosa (RP). METHODS. Twenty-four patients in this prospective, randomized, partially blinded, good-clinical-practice study underwent TES (5-ms biphasic pulses; 20 Hz; DTL electrodes) 30 minutes per week for 6 consecutive weeks. The patients were randomly assigned to one of three groups: sham, 66%, or 150% of individual electrical phosphene threshold (EPT). Visual acuity (VA), visual field (VF; kinetic, static), electroretinography (Ganzfeld, multifocal), dark-adaptation (DA), color discrimination, and EPTs were assessed at all visits or four times, according to the study plan. RESULTS. TES using DTL electrodes was tolerated well; all patients finished the study. Two adverse (foreign body sensation), but no serious adverse events were encountered. There was a tendency for most functional parameters to improve (8/18) or to remain constant (8/18) in the 150% group. VF area and scotopic b-wave amplitude reached statistical significance (P < 0.027 and P < 0.001, respectively). Only desaturated color discrimination and VF mean sensitivity decreased. There was no obvious trend in the 66% group. CONCLUSIONS. TES was found to be safe in RP patients. Positive trends were discovered, but due to the small sample size of this exploratory study, statistical significance was reached only for VF area and scotopic b-wave amplitude. Further studies with larger sample sizes and longer duration are needed to confirm the findings and to define optimal stimulation parameters. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2011;52:4485-4496) DOI:10.1167/iovs.10-6932

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the effect of transcutaneous electrical nerve stimulation (TENS) for inguinal herniorrhaphy postoperative pain control in a prospective, randomized, double-blinded, placebo-controlled study. Forty patients undergoing unilateral inguinal herniorrhaphy with an epidural anesthetic technique were randomly allocated to receive either active TENS or placebo TENS. Postoperative pain was evaluated using a standard 10-point numeric rating scale (NRS). Analgesic requirements were also recorded. TENS (100 Hz, strong but comfortable sensory intensity) was applied for 30 minutes through 4 electrodes placed around the incision twice, 2 and 4 hours after surgery. Pain was assessed before and after each application of TENS and 8 and 24 hours after surgery. In the group treated with active TENS, pain intensity was significantly lower 2 hours (P = .028), 4 hours (P = .022), 8 hours (P = .006), and 24 hours (P = .001) after the surgery when compared with the group that received placebo TENS. Active TENS also decreased analgesic requirements in the postoperative period when compared with placebo TENS (P = .001). TENS is thus beneficial for postoperative pain relief, after inguinal herniorrhaphy; it has no observable side effects, and the pain-reducing effect continued for at least 24 hours. Consequently, the routine use of TENS after inguinal herniorrhaphy is recommended. Perspective: This study presents the hypoalgesic effect of high-frequency TENS for postoperative pain after inguinal herniorrhaphy. This may reinforce findings from basic science showing an opioid-like effect provided by TENS, given that high-frequency TENS has been shown to activate delta-opioid receptors. (C) 2008 by the American Pain Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper demonstrates the oscillatory characteristics of electrical signals acquired from two ornamental plant types (Epipremnum pinnatum and Philodendron scandens - Family Araceae), using a noninvasive acquisition system. The electrical signal was recorded using Ag/AgCl superficial electrodes inside a Faraday cage. The presence of the oscillatory electric generator was shown using a classical power spectral density. The Lempel and Ziv complexity measurement showed that the plant signal was not noise despite its nonlinear behavior. The oscillatory characteristics of the signal were explained using a simulated electrical model that establishes that for a frequency range from 5 to 15 Hz, the oscillatory characteristic is higher than for other frequency ranges. All results show that non-invasive electrical plant signals can be acquired with improvement of signal-to-noise ratio using a Faraday cage, and a simple electrical model is able to explain the electrical signal being generated. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the influence of the colostrum period on pH and, electrical conductivity, we collected 418 milk samples from 127 Jersey cows. The samples were collected from healthy udders that did not present any bacterial growth in the microbiological examination. They were divided into eight groups as follows < 1/2 day; 1/2 and 1 degrees day; 2 degrees day; 3 degrees day; 4 degrees and 5 degrees day; 6 degrees and 7 degrees day; 8 degrees to 15 degrees day; 16 degrees to 30 degrees days of lactation. The samples were collected before milking and the following analyses were conducted: pH, electrical conductivity. In the first 24 hours of lactation, there was an reduction in electrical conductivity value, associated with an increase in pH value. We observed that transition of secretion from colostrum to milk, occurs during the first week of lactation; from 6(rd) day of lactation for pH value and 3(th) day for electrical conductivity value. We recommend the use the following figures as normal ranges for the first 24 hours of lactation (colostrum period): pH <= 6,51 and electrical conductivity <= 6,33 mS/cm; while for the interval between 2(nd) and 7(th) days of lactation (transition from colostrum to milk) we suggest the use of the values as normal ranges: pH <= 6,66 and electrical conductivity <= 5,93 mS/cm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three soil profiles in Ilha Solteira, Brazil were investigated to establish their potential for collapsible behavior. The soil profiles were identified using terrain evaluation techniques and simple laboratory tests. Geophysical surveys were undertaken as they are quick and relatively cheap. The results were correlated with trial pit descriptions and cone and standard penetration tests. The study has shown that electrical resistivity is a useful tool for the preliminary identification of horizons of collapsible soils, before more expensive intrusive and laboratory work is undertaken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Changes in skeletal muscle morphology and metabolism are associated with limited functional capacity in heart failure, which can be attenuated by neuromuscular electrical stimulation (ES). The purpose of the present study was to analyse the effects of ES upon GLUT-4 protein content, fibre structure and vessel density of the skeletal muscle in a rat model of HF subsequent to myocardial infarction. Methods: Forty-four male Wistar rats were assigned to one of four groups: sham (S), sham submitted to ES (S+ES), heart failure (HF) and heart failure submitted to ES (HF+ES). The rats in the ES groups were submitted to ES of the left leg during 20 days (2.5 kHz, once a day, 30 min, duty cycle 50%- 15 s contraction/15 s rest). After this period, the left tibialis anterior muscle was collected from all the rats for analysis. Results: HF+ES rats showed lower values of lung congestion when compared with HF rats (P = 0.0001). Although muscle weight was lower in HF rats than in the S group, thus indicating hypotrophy, 20 days of ES led to their recovery (P < 0.0001). In both groups submitted to ES, there was an increase in muscle vessel density (P < 0.04). Additionally, heart failure determined a 49% reduction in GLUT-4 protein content (P < 0.03), which was recovered by ES (P < 0.01). Conclusion: In heart failure, ES improves morphological changes and raises GLUT-4 content in skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. To verify the muscular force and resistance to the movement of the flexor and extensor muscles of the knee of patients with spasticity after treatment with neuromuscular electrical stimulation (NMES) and isotonic exercises. Patients and methods. The patients this study were divided into group I (NMES) and group 2 (isotonic exercises). Their muscular torque and resistance to the movement of the flexor and extensor knee muscles were measured by the isokinetic dynamometer and the degree of spasticity by the modified Ashworth scale before and after ten sessions. Results. Alterations in the scores of the modified Ashworth scale were not observed. An increase in the flexor torque in group 1 (p = 0.041) and in group 2 (p = 0.001) was verified. In the passive mode, group 1 presented a reduction of resistance to the flexion movement (p = 0.026), while in group 2, a reduction of resistance to both the flexion (p = 0,029) and extension movements (p = 0.019) was verified. Conclusions. The two therapeutical resources had their efficiency proven only for the increase of the force of the flexor muscles. The resistance to movement, the isotonic exercises were more effective because they promoted a reduction in the resistance of the flexor and extensor knee muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Information Visualization, adding and removing data elements can strongly impact the underlying visual space. We have developed an inherently incremental technique (incBoard) that maintains a coherent disposition of elements from a dynamic multidimensional data set on a 2D grid as the set changes. Here, we introduce a novel layout that uses pairwise similarity from grid neighbors, as defined in incBoard, to reposition elements on the visual space, free from constraints imposed by the grid. The board continues to be updated and can be displayed alongside the new space. As similar items are placed together, while dissimilar neighbors are moved apart, it supports users in the identification of clusters and subsets of related elements. Densely populated areas identified in the incSpace can be efficiently explored with the corresponding incBoard visualization, which is not susceptible to occlusion. The solution remains inherently incremental and maintains a coherent disposition of elements, even for fully renewed sets. The algorithm considers relative positions for the initial placement of elements, and raw dissimilarity to fine tune the visualization. It has low computational cost, with complexity depending only on the size of the currently viewed subset, V. Thus, a data set of size N can be sequentially displayed in O(N) time, reaching O(N (2)) only if the complete set is simultaneously displayed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the two-level network design problem with intermediate facilities. This problem consists of designing a minimum cost network respecting some requirements, usually described in terms of the network topology or in terms of a desired flow of commodities between source and destination vertices. Each selected link must receive one of two types of edge facilities and the connection of different edge facilities requires a costly and capacitated vertex facility. We propose a hybrid decomposition approach which heuristically obtains tentative solutions for the vertex facilities number and location and use these solutions to limit the computational burden of a branch-and-cut algorithm. We test our method on instances of the power system secondary distribution network design problem. The results show that the method is efficient both in terms of solution quality and computational times. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2006 the Route load balancing algorithm was proposed and compared to other techniques aiming at optimizing the process allocation in grid environments. This algorithm schedules tasks of parallel applications considering computer neighborhoods (where the distance is defined by the network latency). Route presents good results for large environments, although there are cases where neighbors do not have an enough computational capacity nor communication system capable of serving the application. In those situations the Route migrates tasks until they stabilize in a grid area with enough resources. This migration may take long time what reduces the overall performance. In order to improve such stabilization time, this paper proposes RouteGA (Route with Genetic Algorithm support) which considers historical information on parallel application behavior and also the computer capacities and load to optimize the scheduling. This information is extracted by using monitors and summarized in a knowledge base used to quantify the occupation of tasks. Afterwards, such information is used to parameterize a genetic algorithm responsible for optimizing the task allocation. Results confirm that RouteGA outperforms the load balancing carried out by the original Route, which had previously outperformed others scheduling algorithms from literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors present here a summary of their investigations of ultrathin films formed by gold nanoclusters embedded in polymethylmethacrylate polymer. The clusters are formed from the self-organization of subplantated gold ions in the polymer. The source of the low energy ion stream used for the subplantation is a unidirectionally drifting gold plasma created by a magnetically filtered vacuum arc plasma gun. The material properties change according to subplantation dose, including nanocluster sizes and agglomeration state and, consequently also the material electrical behavior and optical activity. They have investigated the composite experimentally and by computer simulation in order to better understand the self-organization and the properties of the material. They present here the results of conductivity measurements and percolation behavior, dynamic TRIM simulations, surface plasmon resonance activity, transmission electron microscopy, small angle x-ray scattering, atomic force microscopy, and scanning tunneling microscopy. (C) 2010 American Vacuum Society [DOI: 10.1116/1.3357287]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the electrical impedance of an electrolytic cell in the shape of a slab is performed. We have solved, numerically, the differential equations governing the phenomenon of the redistribution of the ions in the presence of an external electric field, and compared the results with the ones obtained by solving the linear approximation of these equations. The control parameters in our study are the amplitude and the frequency of the applied voltage, assumed a simple harmonic function of the time. We show that for the large amplitudes of the applied voltage, the actual current is no longer harmonic at low frequencies. From this result it follows that the concept of electrical impedance of a cell is a useful quantity only in the case where the linear approximation of the fundamental equations of problem work well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead calcium titanate (Pb(1-x)Ca(x)TiO(3) or PCT) thin films have been thermally treated under different oxygen pressures, 10, 40 and 80 bar, by using the so-called chemical solution deposition method. The structural, morphological, dielectric and ferroelectric properties were characterized by x-ray diffraction, FT-infrared and Raman spectroscopy, atomic force microscopy and polarization-electric-field hysteresis loop measurements. By annealing at a controlled pressure of around 10 and 40 bar, well-crystallized PCT thin films were successfully prepared. For the sample submitted to 80 bar, the x-ray diffraction, Fourier transformed-infrared and Raman data indicated deviation from the tetragonal symmetry. The most interesting feature in the Raman spectra is the occurrence of intense vibrational modes at frequencies of around 747 and 820 cm(-1), whose presence depends strongly on the amount of the pyrochlore phase. In addition, the Raman spectrum indicates the presence of symmetry-breaking disorder, which would be expected for an amorphous (disorder) and mixed pyrochlore-perovskite phase. During the high-pressure annealing process, the crystallinity and the grain size of the annealed film decreased. This process effectively suppressed both the dielectric and ferroelectric behaviour. Ferroelectric hysteresis loop measurements performed on these PCT films exhibited a clear decrease in the remanent polarization with increasing oxygen pressure.