60 resultados para Voluntary disclosure
Resumo:
Patella stabilizer muscle response and patellar kinematics were evaluated in 19 women with anterior knee pain (AKP) and 20 healthy women during maximum voluntary isometric contraction (MVIC) with the knee positioned at 15 degrees, 30 degrees and 45 degrees flexion during open (OKC) and closed (CKC) kinetic chain exercises. Patellar kinematics was evaluated through patellar tilt and displacement, and the electrical activity of patellar stabilizers through the root mean square normalized during MVIC and OKC with the knee at 90 degrees flexion. Data revealed that the vastus medialis oblique muscle (VMO) was more active in the control group compared to the AKP group during OKC exercises with the knee at 45 degrees flexion. However, no difference in the patellar kinematics was observed between these groups; nevertheless, the correlation between these parameters also showed, with the knee at 45 degrees flexion, that lateral patellar tilt increase was associated with a reduction in the activity of lateral patellar stabilizers in the control group and with an increase in the VMO activity in the AKP group. In conclusion, electrical activity is an important factor in evaluating AKP and in AKP treatment evolution. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Study design: Cross-sectional study. Objective: Pulmonary functional capacity in 23 Brazilian quadriplegic subjects (ASIA A), aged 30 (9.5) years, weight 66 (10.75) kg, height 176 (7) cm, was investigated at 42 ( 64) months postinjury. Setting: University Hospital-UNICAMP, Campinas, Brazil. Method: Subjects performed forced vital capacity ( FVC) and maximal voluntary ventilation (MVV) tests while seated in their standard wheelchairs. Forced Expired Volume after 1 s (FEV1) and FVC/FEV1 ratio were calculated from these tests. Values obtained were compared to three prediction equations from the literature that are used specifically for spinal cord subjects and include different variables in their formulae, such as age, gender, height, postinjury time and injury level. Data are expressed as median (interquartile interval). Differences between values were demonstrated by median confidence interval with significance level set at a 0.05. Results: Obtained data were statistically different from prediction equation results, with FVC 3.11 ( 0.81), 4.46 (0.28), 4.16 (0.33), 4.26 (0.42); FEV1 2.77 (1.03), 3.67 (0.21), 3.66 (0.30), 3.45 (0.39) and MVV 92 (27), 154.2 (11.9), 156.6 (14),157.3 (16.8), where the first value is obtained experimentally and the second, third and fourth values correspond to predicted values. The results obtained from spirometry test in this study differed significantly from the results obtained when prediction equations were used. Conclusion: The use of prediction equations developed to estimate pulmonary function in wheelchair users significantly overestimates pulmonary function of quadriplegic individuals with complete lesions (ASIA group A), in comparison to measured values.
Resumo:
Imbalance and weakness of the serratus anterior and upper trapezius force couple have been described in patients with shoulder dysfunction. There is interest in identifying exercises that selectively activate these muscles and including it in rehabilitation protocols. This study aims to verify the UT/SA electromyographic (EMG) amplitude ratio, performed in different upper limb exercises and on two bases of support. Twelve healthy men were tested (average age = 22.8 +/- 3.1 years), and surface EMG was recorded from the upper trapezius and serratus anterior using single differential surface electrodes. Volunteers performed isometric contractions over a stable base of support and on a Swiss ball during the wall push-up (WP), bench press (BP), and push-up (PU) exercises. All SEMG data are reported as a percentage of root mean square or integral of linear envelope from the maximal value obtained in one of three maximal voluntary contractions for each muscle studied. A linear mixed-effect model was performed to compare UT/SA ratio values. The WP, BP, and PU exercises showed UT/SA ratio mean +/- SD values of 0.69 +/- 0.72, 0.14 +/- 0.12, and 0.39 +/- 0.37 for stable surfaces, respectively, whereas for unstable surfaces, the values were 0.73 +/- 0.67, 0.43 +/- 0.39, and 0.32 +/- 0.30. The results demonstrate that UT/SA ratio was influenced by the exercises and by the upper limb base of support. The practical application is to show that BP on a stable surface is the exercise preferred over WP and PU on either surfaces for serratus anterior muscle training in patients with imbalance between the UT/SA force couple or serratus anterior weakness.
Resumo:
STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To assess the activation of 7 shoulder muscles under 2 closed kinetic chain (CKC) tasks for the upper extremity using submaximal isometric effort, thus providing relative quantification of muscular isometric effort for these muscles across the CKC exercises, which may be applied to rehabilitation protocols for individuals with shoulder weakness. BACKGROUND: CKC exercises favor joint congruence, reduce shear load, and promote joint dynamic stability. Additionally, knowledge about glenohumeral and periscapular muscle activity elicited during CKC exercises may help clinicians to design protocols for shoulder rehabilitation. METHODS: Using surface electromyography, activation level was measured across 7 shoulder muscles in 20 healthy males, during the performance of a submaximal isometric wall press and bench press. Signals were normalized to the maximal voluntary isometric contraction, and, using paired t tests, data were analyzed between the exercises for each muscle. RESULTS: Compared to the wall press, the bench press elicited higher activity for most muscles, except for the upper trapezius. Levels of activity were usually low but were above 20% maximal voluntary isometric contraction for the serratus anterior on both tasks, and for the long head triceps brachii on the bench press. CONCLUSIONS: Both the bench press and wall press, as performed in this study, led to relatively low EMG activation levels for the muscles measured and may be considered for use in the early phases of rehabilitation. J Ort hop Sports Phys Ther 2011;41(7):520-525, Epub 2 February 2011. doi:10.2519/jospt.2011.3418
Resumo:
Study Design. Prospective clinical electromyographic study in adolescents with idiopathic scoliosis and control group. Objective. To evaluate electromyographic amplitude from erector spinae muscles of patients with idiopathic scoliosis in comparison with control volunteers without spinal deformities. Summary of Background Data. Previous studies have indicated an increased electromyographic activity in paravertebral muscles in the convex side of the scoliotic curvature. However, in previous studies there is the absence or poor description of methods used, and some studies were conducted before the recording and processing recommendations for surface electromyographic signals had been described. Methods. Thirty individuals, matched by sex, age, and body mass index, were divided into two groups: scoliosis and control. The electric activity of the erector spinae muscles was determined by surface electromyography on both sides of the three levels of spine: T8, L2, and L5. Results. Normalized electromyographic amplitudes of erector spinae muscles, in the convex and concave sides of the apex region of the scoliotic curve in the thoracic and lumbar regions, were not significantly different. Also, there was no significant difference between the muscles of these regions when the scoliosis group was compared with the control group. The erector spinae muscle at the L5 level, representing the lower vertebral limit of the lumbar scoliotic curve, had significantly higher electromyographic activity on the convex side. However, the same alteration was shown in the control group homologous muscle (on the left side). Conclusion. Erector spinae muscles on the convex and concave sides at the curvature apex in patients with idiopathic scoliosis and small magnitude of curves did not show significant differences in electromyographic amplitude. Future studies should evaluate whether intragroup activation differences, at the L5 level in 80% of the maximum voluntary isometric contractions with predominance of the left side of the vertebral column, have any relation to the condition.
Resumo:
The study analyzed the effects of chronic alcohol ingestion on the ultrastructure of the lining epithelium of the hard palatine mucosa of rats UChA and UChB (lines with voluntary alcohol consumption) in order to contribute to the understanding of the consequences of alcohol abuse for the morphology of the digestive system. Thirty female adult animals aged 120 days were divided into three experimental groups. (1) Ten UChA rats (genetically low ethanol consumer) with voluntary intake of 10% v/v (5.45 g/kg/day) ethanol solution and water. (2) Ten UChB (genetically high ethanol consumer) rats with voluntary intake of 10% v/v (7.16 g/kg/day) ethanol solution and water. (3) Ten Wistar rats with voluntary ad libitum water intake (control group). Both groups received Nuvital pellets ad libitum. The IGFR-I expression was intense in both experimental groups. The epithelial cells of the alcoholic rats UChA and UChB showed many alterations such as the presence of lipid droplets, altered nuclei, nuclei in corneum layer and disrupted mitochondria. It was concluded that ethanol intake induces ultrastructural lesions in the hard palatine mucosa. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The present study aimed investigate the age and gender influence on maximal molar bite force and at outlining the criteria for normal masticatory muscle development in a sample of 177 Brazilian Caucasian dentate individuals aged 7-80 years divided into five age groups: I(7-12 years), II (13-20 years), III (21-40 years), IV (41-60 years), and V (61-80 years). Except for Group V, which comprised nine women and eight men, all groups were equally divided in respect to gender (20 M/20 F). Bite force was recorded with a mouth-adapted 1000 N dynamometer and the highest out of three records was regarded as the maximal bite force. The data were submitted to multivariate statistical analysis (SPSS 17.0 p < 0.05). Effects of group and gender were found, but no interactions between them. The ANOVA showed significant differences between groups bilaterally. Bonferroni`s test showed that group I had significantly lower bite force means at both sides as compared to all groups, except group V. No differences were found between the left and right sides. In all the groups, gender was found to be a significant factor associated with maximal bite force. A global comparison including all the subjects and measures showed that the means of men were approximately 30% higher than those of women, within-group comparisons yielded similar results in all groups. Muscle thickness was measured with a SonoSite Titan ultrasound tool using a high-resolution real-time 56 mm/10 MHz linear-array transducer. Three ultrasound images were obtained from the bilateral masseter and temporal muscles at rest and at maximal voluntary contraction. The means of the three measures in each clinical condition were analyzed with multivariate statistical analysis (SPSS 17.0 p < 0.05). A gradual increase in thickness of the masseter and temporal muscles was found both at rest and maximal voluntary contraction for groups I to IV, whereas a decrease in muscle thickness was observed in group V. Multivariate analysis showed that in both conditions there was an effect of group and gender. The study of the development of the stomatognathic system in relation to age and gender can provide useful data for the identification of normal and impaired functioning patterns. The results of this study indicate that age and gender are associated with structural and functional alterations in the muscles of the stomatognathic system. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
P>The purpose of this study was to evaluate the influence of age on the electromyographic activity of masticatory muscles. All volunteers were Brazilian, fully dentate (except for Group I - mixed dentition), Caucasian, aged 7-80, and divided into five groups: I (7-12 years), II (13-20 years), III (21-40 years), IV (41-60 years) and V (61-80 years). Except for Group V, which comprised nine women and eight men, all groups were equally divided with respect to gender (20 M/20 F). Surface electromyographic records of masticatory muscles were obtained at rest and during maximal voluntary contraction, right and left laterality, maximal jaw protrusion and maximal clenching in the intercuspal position. Statistically significant differences (P < 0 center dot 05) were found in all clinical conditions among the different age groups. Considerably different patterns of muscle activation were found across ages, with greater electromyographic activity in children and youth, and decreasing from adults to aged people.
Resumo:
Introduction: The aim of this study was to analyze the electromyographic activity of the masseter and temporalis muscles of children having rapid maxillary expansion (RME) with a bonded rapid maxillary expansion appliance. Methods: The sample consisted of 27 children (mean age, 8.6 years) with posterior crossbite who required RME treatment. Electromyographic activity of the masseter and temporalis muscles was analyzed before treatment and after the appliance was removed. The mean interval between the 2 analyses was 5 months. Muscular activity was electromyographically analyzed in rest position, and with maximum voluntary dental clenching and chewing. Differences in the 2 measurements were evaluated by using paired t tests. Results and Conclusions: Electromyographic analysis showed that activity of the masseter and temporalis muscles increased significantly after the expansion appliance was removed during rest, dental clenching, and habitual chewing. (Am J Orthod Dentofacial Orthop 2009;136:355-60)
Resumo:
Forty-five children (31 boys and 14 girls), aged 6-11 years, were included in the study, 15 with a skeletal anterior open bite (SAOB), 15 with a dentoalveolar anterior open bite (DAOB), and 15 with a normal occlusion (CG), defined by clinical evaluation and lateral cephalograms. EMG recordings of the temporal and masseter muscles were performed under maximal voluntary clenching and during chewing. Analysis of variance was used for inter-group analysis, followed by the Tukey post hoc test. A Student`s t-test for paired data was used for intra-group analysis. There were statistically significant differences among the three groups (P < 0.05), with the mean EMG being highest in the CG and lowest in children with a SAOB. The percentage EMG activity during chewing in relation to that during maximal voluntary clenching was more than 100 per cent in the SAOB group. The CG and DAOB groups presented higher EMG activity during clenching compared with chewing (P < 0.001), as well as a greater difference between tasks. In the SAOB group, the neuromuscular system appeared to have a lower capacity to produce EMG activity according to the task, while that in the DAOB group suggests that their functional capacity during growth should also be carefully observed.
Resumo:
Speech understanding disorders in the elderly may be due to peripheral or central auditory dysfunctions. Asymmetry of results in dichotic testing increases with age, and may reflect on a lack of inter-hemisphere transmission and cognitive decline. Aim: To investigate auditory processing of aged people with no hearing complaints. Study design: clinical prospective. Materials and Methods: Twenty-two voluntary individuals, aged between 55 and 75 years, were evaluated. They reported no hearing complaints and had maximal auditory thresholds of 40 dB HL until 4 KHz, 80% of minimal speech recognition scores and peripheral symmetry between the ears. We used two kinds of tests: speech in noise and dichotic alternated dissyllables (SSW). Results were compared between males and females, right and left ears and between age groups. Results: There were no significant differences between genders, in both tests. Their Left ears showed worse results, in the competitive condition of SSW. Individuals aged 65 or older had poorer performances than those aged 55 to 64. Conclusion: Central auditory tests showed worse performance with aging. The employment of a dichotic test in the auditory evaluation setting in the elderly may help in the early identification of degenerative processes, which are common among these patients.
Implant-supported prosthesis following Branemark protocol on electromyography of masticatory muscles
Resumo:
This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however, in the MVC, Group I presented lower values when compared to dentate group. Despite presenting different EMG values in all of the clinical conditions, both groups showed similar EMG patterns of muscle activation which demonstrates that the proposed treatment can be considered as a good option for oral rehabilitation.
Resumo:
The aim of this study was to analyze the immediate effect of resilient splints through surface electromyography testing and to compare the findings with the electromyographic profiles of asymptomatic subjects. The participants were 30 subjects, 15 patients with TMD (TMD Group) and 15 healthy subjects (Control Group), classified according to Research Diagnostic Criteria (RDC/TMD) Axis I. A resilient occlusal splint was made for each patient in the TMD Group from two mm thick silicon to cover all teeth. The EMG examination was performed before and immediately after installing the splint. Three tests were performed as follows: 1. Maximum Voluntary Contraction (MVC) using cotton rolls (standards test); 2. MVC in maximal intercuspation position; and 3. MVC with the splint in position. The EMG signal was recorded for five seconds. EMG indices were calculated to assess muscle symmetry, jaw torque, and impact. There was a statistically significant difference when comparing the results among the study groups. The symmetry index values in the Control Group were higher than the TMD Initial Group and similar to the TMD Group after the installation of the splint. The index values of torque were higher in TMD Initial Group when compared with the Controls. Impact values were lower than normal values in the TMD Initial Group and restored upon installation of the splint. The resilient occlusal splints may be used as complementary or adjunctive treatment of temporomandibular disorders.