48 resultados para Trace elements.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anomalous and natural concentrations of Cr(6+), occasionally exceeding the permitted limit for human consumption (0.05 mg/L), have been detected in groundwater in the northwestern region of the state of Sao Paulo. As part of a water-rock interaction investigation, this article describes the chemical and mineralogical characterization of rock samples taken from boreholes in the municipality of Urania, with the objective of identifying Cr-bearing minerals and determining how chromium is associated with these minerals. Rock sample analysis were performed using X-ray Fluorescence, X-ray Diffraction, Scanning Electron Microscopy, electron microprobe and sequential extraction techniques. Chemical analyses indicated that the quartzose sandstones show a geochemical anomaly of chromium, with an average content of 221 ppm, which is higher than the reported chromium content of generic sandstones (35 ppm). Diopside was identified as the primary Cr-bearing mineral potentially subject to weathering processes, with a chromium content of up to 1.2% as Cr(2)O(3). Many of the diopside grains showed dissolution features, confirming the occurrence of weathering. Sequential extraction experiments indicated that 99.3% of the chromium in samples is tightly bonded to minerals, whereas 0.24% is weakly bonded via adsorption. Assuming hypothetically that all adsorbed chromium is released via desorption, the theoretical Cr concentration in water would be one order of magnitude higher than the concentrations of Cr(6+) detected in groundwater. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present study, cadmium and lead in the muscle, lung, liver and kidney of dolphins (Sotalia guianensis and Stenella clymene) of the Bahia coast in the northwest of Brazil were determined by graphite furnace atomic absorption spectrometry. Samples were digested using a diluted oxidant mixture (HNO(3) + H(2)O(2)) with a microwave heating program performed in five steps. The optimized temperatures and chemical modifier for the pyrolysis and atomization were 700 degrees C, 1400 degrees C and Pd plus Mg for Cd, and 900 degrees C, 1800 degrees C and NH(4)H(2)PO(4) for Pb, respectively. Characteristic masses and limits of detections (n = 20, 3 sigma) for Cd and Pb were 1.6 and 9.0 pg and 0.82 ng g(-1) and 0.50 ng g(-1), respectively. Repeatability ranged from 0.87 to 8.22% for Cd and 4.31 to 8.09% for Pb. The found concentrations presented no statistical differences at the 95% confidence level when compared with the ICP OES methods. Addition and recovery tests were also performed and the results ranged between 87 and 112% for both elements. Samples of cetacean Dolphinidae (S. guianensis and S. clymene) were analyzed, and the higher concentrations ranged from 0.09 to 46.2 mu g g(-1) for Cd and 0.04 to 0.47 mu g g(-1) for Pb in liver, and from 0.133 to 277 mu g g(-1) for Cd in the kidney. (C) 2010 Elsevier By. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The physical and chemical characteristics of peat were assessed through measurement of pH, percentage of organic matter, cationic exchange capacity (CEC), elemental analysis, infrared spectroscopy and quantitative analysis of metals by ICP OES. Despite the material showed to be very acid in view of the percentage of organic matter, its CEC was significant, showing potential for retention of metal ions. This characteristic was exploited by coupling a peat mini-column to a flow system based on the multicommutation approach for the in-line copper concentration prior to flame atomic absorption spectrometric determination. Cu(II) ions were adsorbed at pH 4.5 and eluted with 0.50 mol L(-1) HNO(3). The influence of chemical and hydrodynamic parameters, such as sample pH, buffer concentration, eluent type and concentration, sample flow-rate and preconcentration time were investigated. Under the optimized conditions, a linear response was observed between 16 and 100 mu g L(-1), with a detection limit estimated as 3 mu g L(-1) at the 99.7% confidence level and an enrichment factor of 16. The relative standard deviation was estimated as 3.3% (n = 20). The mini-column was used for at least 100 sampling cycles without significant variation in the analytical response. Recoveries from copper spiked to lake water or groundwater as well as concentrates used in hemodialysis were in the 97.3-111 % range. The results obtained for copper determination in these samples agreed with those achieved by graphite furnace atomic absorption spectrometry (GFAAS) at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.