76 resultados para Somatic Mutation and Recombination Test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Hydration and integrity of the horny layer is essential to normal skin function. Objective: Comparison of the hydrating properties of three moisturizers with pimecrolimus cream vehicle. Methods: Four test preparations (high-quality skin cream, cold cream emulsion, emollient oil, pimecrolimus cream vehicle) were applied to four different regions of the forearms and legs. Transepidermal water loss (TEWL) was assessed by evaporimetry at baseline, and 3 and 6 hours after arm application, and electrical capacitance was assessed by corneometry at baseline, and 1, 2, 3 and 6 hours after leg application. Results: Corneometry assessment - in terms of efficacy in moisturizing the skin, test preparations were ranked (best to worst): high-quality skin cream (45.9 arbitrary units versus 75.3; p < 0.001) > pimecrolimus vehicle cream (46.6 versus 61.5; p < 0.001) > emollient oil (43.5 versus 54.8; p = 0.006) > cold cream emulsion (44.8 versus 49.9; p = 0.738). Untreated skin (control) had a mean capacitance of 44.8 units at baseline and 48.5 units at endpoint. Evaporimetry (assessment of TEWL) revealed no significant differences between control and any test preparation at any timepoint. Conclusions: Pimecrolimus cream vehicle has skin hydration properties comparable with highly effective commercially available products. No test preparation had a significant effect on TEWL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Childhood-onset mitochondrial encephalomyopathies are usually severe, relentlessly progressive conditions that have a fatal outcome. However, a puzzling infantile disorder, long known as `benign cytochrome c oxidase deficiency myopathy` is an exception because it shows spontaneous recovery if infants survive the first months of life. Current investigations cannot distinguish those with a good prognosis from those with terminal disease, making it very difficult to decide when to continue intensive supportive care. Here we define the principal molecular basis of the disorder by identifying a maternally inherited, homoplasmic m.14674T > C mt-tRNA(Glu) mutation in 17 patients from 12 families. Our results provide functional evidence for the pathogenicity of the mutation and show that tissue-specific mechanisms downstream of tRNA(Glu) may explain the spontaneous recovery. This study provides the rationale for a simple genetic test to identify infants with mitochondrial myopathy and good prognosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The perception of improvement by a patient has assumed a central role in functional evaluation after a variety of knee problems. One of the instruments most used in clinical research is the International Knee Documentation Committee (IKDC) Subjective Knee Form because its psychometric properties are considered to be excellent. Nonetheless, this questionnaire was originally developed for use in the English language. Therefore, to use this questionnaire in the Brazilian population, it is essential to translate and validate it. Purpose: The aim of this study was to translate the IKDC Subjective Knee Form into a Brazilian version and to test its validity and reproducibility. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The translation of the original IKDC Subjective Knee Form into a Brazilian version was accomplished in accordance with the American Orthopaedic Society for Sports Medicine guidelines and was tested in 32 patients with knee pathologic conditions to develop the first Brazilian version. To test validity and reproducibility, 117 patients with several knee complaints completed the Brazilian IKDC Subjective Knee Form, the Short Form 36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Lysholm score. From these patients, 85 were retested within a week to achieve reproducibility. The validation was addressed by correlating the Brazilian IKDC Subjective Knee Form to the other outcome measures. The reproducibility was tested by measuring internal consistency, test-retest reliability, and agreement. Results: The Brazilian IKDC Subjective Knee Form was highly related to the physical component summary of the SF-36, the Lysholm score, and the WOMAC, and weakly related to the mental component summary of SF-36 (r=.79, .89, .85, and .51, respectively). The internal consistency was strong, with a Cronbach a value of .928 and .935 in the test and retest assessment, respectively. The test-retest reliability proved to be excellent, with a high value of the intraclass correlation coefficient (.988), as well as the agreement, demonstrated by the low differences between the means of the test and retest, and the short limit of agreement, observed in the Altman-Bland and survival-agreement plots. Conclusion: The results of this study provide evidence that the Brazilian IKDC Subjective Knee Form has psychometric properties similar to the original version. In addition, it was a reliable evaluation instrument for patients with knee-related problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Conflicting results have been reported in studies evaluating the relationship between serum markers of iron overload, liver iron deposits, and HFE mutations (C282Y and H63D) in chronic hepatitis C patients, and also their impact on the response to therapy in these patients. Aim To evaluate the role of HFE mutations in the severity of liver disease and in the response to therapy in chronic hepatitis C. Methods Two hundred and sixty-four hepatitis C patients treated with standard interferon and ribavirin were divided into two groups according to type of antiviral response: sustained virological response (SVR) and nonresponse or relapse. We evaluated the relationship between HFE mutation and the type of antiviral response, clinical data, biochemical tests, liver histopathology, virological data, and HFE mutations. Results Of the 264 patients, 88 (32.1%) had SVR whereas 67.9% had nonresponse or relapse. Liver iron deposits were observed in 49.2% of the patients. The factors associated with SVR were hepatitis C virus genotype 2 or 3, transferrin saturation value of 45% or less, and detection of the H63D mutation. HFE mutation was more frequent in patients with iron deposits, but without association with serum iron biochemistry or severity of liver disease. Steatosis was more frequent in patients with liver iron deposits. Conclusion The H63D mutation was an independent factor associated with SVR in chronic hepatitis C patients, as also were hepatitis C virus genotype 2 or 3 and transferrin saturation value of 45% or less. Moreover, the H63D mutation was associated with liver iron deposits. Eur J Gastroenterol Hepatol 22: 1204-1210 (C) 2010 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anti-obesity medications deserve special considerations at the present time due to an increasing number of overweight and obese people who require these therapeutic alternatives. Obesity is positively associated with several chronic illnesses, including cancer. In this work, we evaluated the possible genotoxic and/or cytotoxic actions of two drugs, sibutramine and fenproporex, in the doses of 10, 20 and 40 mg/kg body weight (bw), administered intraperitoneally in male Swiss mice. The genotoxic effect was analyzed by comet assay and micronucleus test. We found that both drugs increased the frequency of genotoxic damage in Swiss mice, but did not present cytotoxic activities towards the polychromatic erythrocytes of the bone marrow of these animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (131); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunological systems have been an abundant inspiration to contemporary computer scientists. Problem solving strategies, stemming from known immune system phenomena, have been successfully applied to chall enging problems of modem computing. Simulation systems and mathematical modeling are also beginning use to answer more complex immunological questions as immune memory process and duration of vaccines, where the regulation mechanisms are not still known sufficiently (Lundegaard, Lund, Kesmir, Brunak, Nielsen, 2007). In this article we studied in machina a approach to simulate the process of antigenic mutation and its implications for the process of memory. Our results have suggested that the durability of the immune memory is affected by the process of antigenic mutation.and by populations of soluble antibodies in the blood. The results also strongly suggest that the decrease of the production of antibodies favors the global maintenance of immune memory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mutations of the mitofusin 2 (MFN2) gene have been reported to be the most common cause of the axonal form of Charcot Marie Tooth disease (CMT). The aim of this study was to describe a de novo MFN2 p.R104W mutation and characterize the associated phenotype. We screened the entire coding region of MFN2 gene and characterized its clinical phenotype, nerve conduction studies and sural nerve biopsy. Neuropsychological tests and brain MRI were also performed. A de nova mutation was found in exon 4 (c.310C > T; p.R104W). In addition to a severe and early onset axonal neuropathy, the patient presented learning problems, obesity, glucose intolerance, leukoencephalopathy, brain atrophy and evidence of myelin involvement and mitochondrial structural changes on sural nerve biopsy. These results suggest that MFN2 p.R104W mutation is as a hot-spot for MFN2 gene associated to a large and complex range of phenotypes. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Newly formed biofilm after implant debridement may challenge the long-term stability of peri-implant therapy. This in vitro study aimed to assess the roughness and adherence of Streptococcus sanguinis after treatment of smooth and rough titanium surfaces with an erbium-doped: yttrium, aluminum, and garnet (Er:YAG) laser, metal and plastic curets, and an air-powder abrasive system. Methods: Forty titanium disks with smooth-machined surfaces and 40 with sand-blasted and acid-etched surfaces were divided into the following treatment groups: Er:YAG laser; plastic curet; metal curet, and air-powder abrasive system. The surface roughness (roughness average [Raj) before and after treatments was determined using a profilometer. S. sanguinis (American Type Culture Collection 10556) was grown on treated and untreated specimens, and the amounts of retained bacteria on the surfaces were measured by the culture method. Rough and smooth surfaces with and without a suspension of S. sanguinis were also analyzed using scanning electron microscopy (SEM). Results: For smooth surfaces, the roughest surfaces were produced by metal curets (repeated - measures analysis of variance [ANOVA] and Tukey test; P<0.05). The rough-surface profile was not altered by any of the treatments (repeated-measures ANOVA; P>0.05). Rough surfaces treated with metal curets and air-powder abrasion showed the lowest level of bacteria] adhesion (two-way ANOVA and Tukey test; P<0.05). SEM analysis revealed distinct surface profiles produced by all devices. Conclusions: Metal curets are not recommended for smooth titanium surface debridement due to severe texture alteration. Rough surfaces treated with a metal curet and the air-powder abrasive system were less susceptible to bacterial adhesion, probably due to texture modification and the presence of abrasive deposits. J Periodontol 2009;80: 1824-1832.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. Methods and Materials: Three photoactivation protocols (600mW/cm(2) x 40 seconds; 400 mW/cm(2) x 60 seconds or 200 mW/cm(2) x 20 seconds, followed by 500 mW/cm(2) X 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 nun diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silvernitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification. Results: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400mW/cm(2) that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source. Conclusions: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the influence of addition of 10% calcium chloride (CaCl(2)) on the setting time, solubility, disintegration, and pH of white MTA (WMTA) and white Portland cement (WPC). A test of the setting time was performed following the #57 ADA specifications and a test of the final setting time according to the ASTM. For the solubility tests disintegration and pH, Teflon rings were filled with the cements and weighed after setting. After 24 h in a desiccator, they were once again weighed. Thereafter, they were immersed in MiliQ water for 24 and 72 h and 7, 14, and 28 days, with maintenance in the desiccator and weighing between periods. The pH of water in which the rings were immersed was measured immediately after contact with them and in the other periods. The addition of CaCl(2) provided a significant reduction (50%) in the initial setting time of cements. The final setting time of WMTA was reduced in 35.5% and the final setting time of WPC in 68.5%. The WMTA with CaCl(2) absorbed water and gained weight with time, except for in the 24-h period. The addition of CaCl(2) to the WPC reduced its solubility. The addition of CaCl(2) increased the pH of WMTA in the immediate period and at 24 and 72 h and for WPC in the immediate period and at 24 h. The addition of CaCl(2) to WMTA and WPC reduced the setting times and solubility of both and increased the pH of cements in the initial periods. (J Endod 2009;35:550-554)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to analyze the effect of glass-ionomer cement as a liner on the dentin/resin adhesive interface of lateral walls of occlusal restorations after thermocycling. Materials and Methods: Occlusal cavities were prepared in 60 human molars, divided into six groups: no liner (1 and 4); glass-ionomer cement (GIC, Ketac Molar Easymix, 3M ESPE) (2 and 5); and resin-modified glass-ionomer cement (RMGIC, Vitrebond, 3M ESPE) (3 and 6). Resin composite (Filtek Z250, 3M ESPE) was placed after application of an adhesive system (Adper Single Bond 2, 3M ESPE) that was mixed with a fluorescent reagent (Rhodamine B) to allow confocal microscopy analysis. Specimens of groups 4, 5 and 6 were thermocycled (5 degrees C-55 degrees C) with a dwell time of 30 seconds for 5000 cycles. After this period, teeth were sectioned in approximately 0.8-mm slices. One slice of each tooth was randomly selected for confocal microscopy analysis. The other slices were sectioned into 0.8 nun x 0.8 mm beams, which were submitted to microtensile testing (MPa). Data were analyzed using two-way ANOVA and Tukey test (p < 0.05). Results: There was no detectedstatistical difference on bond strength among groups (alpha < 0.05). Confocal microscopy analysis showed a higher mean gap size in group 4(12.5 mu m) and a higher percentage of marginal gaps in the thermocycled groups. The RNIGIC liner groups showed the lowest percentage of marginal gaps. Conclusions: Lining with RMGIC resulted in less gap formation at the dentin/resin adhesive interface after artificial aging. RMGIC or GIC liners did not alter the microtensile bond strength of adhesive system/resin composite to dentin on the lateral walls of Class I restorations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate whether the type of cola drink (regular or diet) could influence the wear of enamel subjected to erosion followed by brushing abrasion, Method and !Materials: Ten volunteers wore intraoral devices that each had eight bovine enamel blocks divided into four groups; ER, erosion with regular cola; EAR, erosion with regular cola plus abrasion; EL, erosion with light cola; and EAL, erosion with light cola plus abrasion, Each day for 1 week, half of each device was immersed in regular cola for 5 minutes, Then, two blocks were brushed using a fluoridated toothpaste and electric toothbrush for 30 seconds four times daily, Immediately after, the other half of the device was subjected to the same procedure using a light cola, The pH, calcium, phosphorus, and fluoride concentrations of the colas were analyzed using standard procedures, Enamel alterations were measured by profilometry. Data were tested using two-way ANOVA and Bonferroni test (P < .05), Results: Regarding chemical characteristics, light cola presented pH 3.0, 13.7 mg Ca/L, 15.5 mg P/L, and 0.31 mg F/L, while regular cola had pH 2.6, 32.1 mg Ca/L, 1:8.1 mg P/L, and 0.26 mg F/L, The light cola promoted less enamel loss (EL, 0.36 pm; EAL, 0.39 pm) than its regular counterpart (ER, 0.72 pm; EAR, 0.95 pm) for both conditions, There was not a significant difference (P > .05) between erosion and erosion plus abrasion for light cola, However, for regular cola, erosion plus abrasion resulted in higher enamel loss than erosion alone,.nclusion: The data suggest that light cola promoted less enamel wear even when erosion was followed by brushing abrasion, (Quintessence Int 2011;42:xxx-xx)()

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber posts and varying quantities of coronal dentin. Sixty freshly extracted upper canines were randomly divided into groups of 10 teeth each. The specimens were exposed to 250,000 cycles in a controlled chewing simulator. All intact specimens were subjected to a static load (N) in a universal testing machine at 45 degrees to the long axis. Data were analyzed by 1-way analysis of variance and Tukey test (alpha = .05). Significant differences (P < .001) were found among the mean fracture forces of the test groups (positive control, 0 mm, 1 mm, 2 mm, 3 mm, and negative control groups: 1022.82 N, 1008.22 N, 1292.52 N, 1289.19 N, 1255.38 N, and 1582.11, respectively). These results suggested that the amount of coronal dentin did not significantly increase the fracture resistance of endodontically treated teeth restored with prefabricated carbon fiber post and composite resin core. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:e52-e57)