130 resultados para Sequential organ failure assessment score


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate glomerular development and expression of insulin and insulin-like growth factor receptors in an experimental model of intrauterine growth restriction (IUGR). Material and Methods: We studied three groups of Sprague-Dawley fetuses: IUGR - restricted by ligation of the right uterine artery; C-IUGR - left horn controls, and EC - external controls (non-manipulated). Body and organs were weighed, and glomerular number and volume were analyzed. Expression of IR beta, IRS-1, IRS-2 and IGF-IR beta was analyzed in liver, intestine and kidneys by immunoblotting. Results: Organ/body weight ratios were similar. In IUGR, glomerular number and volume were increased compared to C-IUGR and EC (p < 0.001). In the IUGR liver, increases were found in IGF-IR beta compared to C-IUGR and EC; IR beta compared to EC, and IRS-2 compared to C-IUGR. However, decreases in IR beta were noted in IUGR compared to C-IUGR; IRS-1 compared to C-IUGR and EC, and IRS-2 compared to EC. In IUGR intestine, increases were detected in IR beta, IRS-1 and IGF-IR beta compared to C-IUGR and EC. In IUGR kidneys, increases were observed in IR beta and IGF-IR beta compared to C-IUGR and EC, and IRS-1 compared to EC. Decreased IRS-2 in the intestine and kidney were noticed in IUGR compared to C-IUGR and EC. Conclusion: IUGR fetuses had less glomeruli and alterations in insulin receptors, which may be associated with an increased risk of disease occurrence in adulthood. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rationale Sepsis is a leading cause of death in the intensive care unit, characterized by a systemic inflammatory response (SIRS) and bacterial infection, which can often induce multiorgan damage and failure. Leukocyte recruitment, required to limit bacterial spread, depends on phosphoinositide-3 kinase gamma (PI3K gamma) signaling in vitro; however, the role of this enzyme in polymicrobial sepsis has remained unclear. Objectives: This study aimed to determine the specific role of the kinase activity of PI3K gamma in the pathogenesis of sepsis and multiorgan damage. Methods. PI3K gamma wild-type, knockout, and kinase-dead mice were exposed to cecal ligation and perforation induced sepsis and assessed for survival; pulmonary, hepatic, and cardiovascular damage; coagulation derangements; systemic inflammation; bacterial spread; and neutrophil recruitment. Additionally, wild-type mice were treated either before or after the onset of sepsis with a PI3K gamma inhibitor and assessed for survival, neutrophil recruitment, and bacterial spread. Measurements and Main Results: Both genetic and pharmaceutical PI3K gamma kinase inhibition significantly improved survival, reduced multiorgan damage, and limited bacterial decompartmentalization, while modestly affecting SIRS. Protection resulted from both neutrophil-independent mechanisms, involving improved cardiovascular function, and neutrophil-dependent mechanisms, through reduced susceptibility to neutrophil migration failure during severe sepsis by maintaining neutrophil surface expression of the chemokine receptor, CXCR2. Furthermore, PI3K gamma pharmacological inhibition significantly decreased mortality and improved neutrophil migration and bacterial control, even when administered during established septic shock. Conclusions: This study establishes PI3K gamma as a key molecule in the pathogenesis of septic infection and the transition from SIRS to organ damage and identifies it as a novel possible therapeutic target.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The frontal assessment battery (FAB) is a bedside cognitive scale designed to measure executive functions. Huntington`s disease (HD) is a neurodegenerative disorder characterized by motor, behavioral, and cognitive dysfunction. The aim of this study was to check the validity of the FAB for the evaluation of cognitive impairment in patients with HD. Forty-one patients diagnosed with HD and 53 healthy controls matched by education, sex and age were evaluated with a validated Brazilian version of the UHDRS, the VFT, the SDMT, the SIT, the MMSE, and the FAB. The diagnosis of HD was made by DNA analysis. FAB scores were lower in patients than in the controls (p < 0.001) and had significant correlations with the VFT (r = 0.79; p < 0.05), the SDMT (r = 0.80; p < 0.05), the SIT (r = 0.72; p < 0.05), the MMSE (r = 0.83; p < 0.05), the FCS (r = 0.79; p < 0.05) and the motor section of the UHDRS (r = -0.80; p < 0.05). The FAB differentiated between HD patients in the initial and later stages of the disease. The one-year longitudinal evaluation revealed a global trend toward a worsening in the second score of the FAB. The results demonstrate that the FAB presents good internal consistency and also convergent and discriminative validity; therefore it is a useful scale to assess executive functions and to evaluate cognitive impairment in patients with HD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives To introduce a comprehensive and reliable scoring system for the assessment of whole-knee joint synovitis based on contrast-enhanced (CE) MRI. Methods Multicenter Osteoarthritis Study (MOST) is a cohort study of people with, or at high risk of, knee osteoarthritis (OA). Subjects are an unselected subset of MOST who volunteered for CE-MRI. Synovitis was assessed at 11 sites of the joint. Synovial thickness was scored semiquantitatively: grade 0 (< 2 mm), grade 1 (2-4 mm) and grade 2 (> 4 mm) at each site. Two musculoskeletal radiologists performed the readings and inter-and intrareader reliability was evaluated. Whole-knee synovitis was assessed by summing the scores from all sites. The association of Western Ontario and McMaster Osteoarthritis Index pain score with this summed score and with the maximum synovitis grade for each site was assessed. Results 400 subjects were included (mean age 58.8 +/- 7.0 years, body mass index 29.5 +/- 4.9 kg/m(2), 46% women). For individual sites, intrareader reliability (weighted kappa) was 0.67-1.00 for reader 1 and 0.60-1.00 for reader 2. Inter-reader agreement (kappa) was 0.67-0.92. For the summed synovitis scores, intrareader reliability (intraclass correlation coefficient (ICC)) was 0.98 and 0.96 for each reader and inter-reader agreement (ICC) was 0.94. Moderate to severe synovitis in the parapatellar subregion was associated with the higher maximum pain score (adjusted OR (95% CI), 2.8 (1.4 to 5.4) and 3.1 (1.2 to 7.9), respectively). Conclusions A comprehensive semiquantitative scoring system for the assessment of whole-knee synovitis is proposed. It is reliable and identifies knees with pain, and thus is a potentially powerful tool for synovitis assessment in epidemiological OA studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The protective effect of carvedilol on multiple organ damage induced by angiotensin II (Ang II) remains unclear. The aim of this study was to evaluate the protective effect of carvedilol on the heart, liver, and kidney in rats infused with Ang II. Material/Methods: Wistar rats were randomly distributed into three groups: control (no treatment), continuously infused with Ang II (150 eta g/min for 72 hr), and treated with Ang II + carvedilol (90 mg/kg/d). Histological sections of the myocardium, kidney, and liver were analyzed for the presence of necrosis. Results: Ang II induced arterial hypertension which was not affected by carvedilol treatment (tail-cuff blood pressures, control: 125 +/- 13.6, Ang II: 163 +/- 27.3, Ang II + CV: 178 +/- 39.8 mmHg, p<0.05). Also, there were perivascular inflammation and necrosis in the myocardium, kidney, and hepatocytes necrosis around the terminal vein. Carvedilol treatment fully prevented damage to the heart and kidney and attenuated liver lesions induced by the Ang II infusion. Conclusions: The protective effect of carvedilol on perivascular damage induced by Ang II infusion depended on the target organ. The prevention of heart damage occurred independently of the antihypertensive effects of carvedilol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to standardize signs and diagnostic criteria of respiratory function in newborn puppies delivered normally or after dystocia and caesarean operation. A total of 48 neonates were allocated into groups: eutocia (n = 20), dystocia (n = 8), caesarean (c)-section (n = 20). Neonatal health was assessed using the Apgar score and body temperature was determined at 0, 5 and 60 min after delivery. Venous blood gases (pO(2) and SO(2)) was measured immediately and 60 min after delivery, and a thoracic radiograph was made between 0 and 5 min of life. The c-section group had significantly lower Apgar scores at birth and 5 min. Hypothermia was present at 5 min in the eutocia and c-section groups, and at 60 min in all groups. The eutocia group had an irregular respiratory pattern in 78% of puppies at birth, 27.7% at 5 min and 21% at 60 min compared with 87.5%, 62.5% and 12.5% of the pups in the dystocia group where there was irregular respiratory rhythm, moderate to intense respiratory sounds with agonic episodes. The c-section group had respiratory alterations in 70%, 45% and 16% of puppies at 0, 5 and 60 min, respectively. Radiographic abnormalities were present in 17% of the pups in the eutocia group, 25% of the pups in the dystocia group and 30% of the pups in the c-section group, respectively. The c-section group had significantly lower SO(2) values at 60 min than at birth. All puppies had hypoxaemia, but a significant decrease was observed in the c-section group. Newborn puppies had tissue hypoxia and irregular respiratory pattern at birth. Caesarean-section puppies had lower vitality; however, all developed satisfactory Apgar scores at 5 min of life, regardless of the obstetric condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Spinal cord injury (SCI) causes motor and sensory deficits that impair functional performance, and significantly impacts life expectancy and quality. Animal models provide a good opportunity to test therapeutic strategies in vivo. C57BL/6 mice were subjected to laminectomy at T9 and compression with a vascular clip (30 g force, 1 min). Two groups were analyzed: injured group (SCI, n = 33) and laminectomy only (Sham, n = 15). Locomotor behavior (Basso mouse scale-BMS and global mobility) was assessed weekly. Morphological analyses were performed by LM and EM. The Sham group did not show any morphofunctional alteration. All SCI animals showed flaccid paralysis 24 h after injury. with subsequent improvement. The BMS score of the SCI group improved until the intermediate phase (2.037 +/- 1.198): the Sham animals maintained the highest BMS score (8.981 +/- 0.056). p < 0.001 during the entire time. The locomotor speed was slower in the SCI animals (5.581 +/- 0.871) than in the Sham animals (15.80 +/- 1.166), p < 0.001. Morphological analysis of the SCI group showed, in the acute phase, edema, hemorrhage, multiple cavities, fiber degeneration, cell death and demyelination. In the chronic phase we observed glial scarring, neuron death, and remyelination of spared axons by oligodendrocytes and Schwann cells. In conclusion, we established a simple, reliable, and inexpensive clip compression model in mice, with functional and morphological reproducibility and good validity. The availability of producing reliable injuries with appropriate outcome measures represents great potential for studies involving cellular mechanisms of primary injury and repair after traumatic SCI. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, we discuss inferential aspects of the measurement error regression models with null intercepts when the unknown quantity x (latent variable) follows a skew normal distribution. We examine first the maximum-likelihood approach to estimation via the EM algorithm by exploring statistical properties of the model considered. Then, the marginal likelihood, the score function and the observed information matrix of the observed quantities are presented allowing direct inference implementation. In order to discuss some diagnostics techniques in this type of models, we derive the appropriate matrices to assessing the local influence on the parameter estimates under different perturbation schemes. The results and methods developed in this paper are illustrated considering part of a real data set used by Hadgu and Koch [1999, Application of generalized estimating equations to a dental randomized clinical trial. Journal of Biopharmaceutical Statistics, 9, 161-178].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the Eplerenone Post-Acute Myocardial Infarction Heart Failure Efficacy and Survival Study ( n = 6632), eplerenone- associated reduction in all- cause mortality was significantly greater in those with a history of hypertension ( Hx- HTN). There were 4007 patients with Hx- HTN ( eplerenone: n = 1983) and 2625 patients without Hx- HTN ( eplerenone: n = 1336). Propensity scores for eplerenone use, separately calculated for patients with and without Hx- HTN, were used to assemble matched cohorts of 1838 and 1176 pairs of patients. In patients with Hx- HTN, all- cause mortality occurred in 18% of patients treated with placebo ( rate, 1430/ 10 000 person- years) and 14% of patients treated with eplerenone ( rate, 1058/ 10 000 person- years) during 2350 and 2457 years of follow- up, respectively ( hazard ratio [ HR]: 0.71; 95% CI: 0.59 to 0.85; P < 0.0001). Composite end point of cardiovascular hospitalization or cardiovascular mortality occurred in 33% of placebo-treated patients ( 3029/ 10 000 person- years) and 28% of eplerenone- treated patients (2438/10 000 person- years) with Hx- HTN ( HR: 0.82; 95% CI: 0.72 to 0.94; P = 0.003). In patients without Hx- HTN, eplerenone reduced heart failure hospitalization ( HR: 73; 95% CI: 0.55 to 0.97; P = 0.028) but had no effect on mortality ( HR: 0.91; 95% CI: 0.72 to 1.15; P = 0.435) or on the composite end point ( HR: 0.91; 95% CI: 0.76 to 1.10; P = 0.331). Eplerenone should, therefore, be prescribed to all of the post - acute myocardial infarction patients with reduced left ventricular ejection fraction and heart failure regardless of Hx- HTN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A síndrome do X Frágil é a causa mais frequente de deficiência intelectual hereditária. A variante de Dandy-Walker trata-se de uma constelação específica de achados neurorradiológicos. Este estudo relata achados da comunicação oral e escrita de um menino de 15 anos com diagnóstico clínico e molecular da síndrome do X-Frágil e achados de neuroimagem do encéfalo compatíveis com variante de Dandy-Walker. A avaliação fonoaudiológica foi realizada por meio da Observação do Comportamento Comunicativo, aplicação do ABFW - Teste de Linguagem Infantil - Fonologia, Perfil de Habilidades Fonológicas, Teste de Desempenho Escolar, Teste Illinois de Habilidades Psicolinguísticas, avaliação do sistema estomatognático e avaliação audiológica. Observou-se: alteração de linguagem oral quanto às habilidades fonológicas, semânticas, pragmáticas e morfossintáticas; déficits nas habilidades psicolinguísticas (recepção auditiva, expressão verbal, combinação de sons, memória sequencial auditiva e visual, closura auditiva, associação auditiva e visual); e alterações morfológicas e funcionais do sistema estomatognático. Na leitura verificou-se dificuldades na decodificação dos símbolos gráficos e na escrita havia omissões, aglutinações e representações múltiplas com o uso predominante de vogais e dificuldades na organização viso-espacial. Em matemática, apesar do reconhecimento numérico, não realizou operações aritméticas. Não foram observadas alterações na avaliação audiológica periférica. A constelação de sintomas comportamentais, cognitivos, linguísticos e perceptivos, previstos na síndrome do X-Frágil, somada às alterações estruturais do sistema nervoso central, pertencentes à variante de Dandy-Walker, trouxeram interferências marcantes no desenvolvimento das habilidades comunicativas, no aprendizado da leitura e escrita e na integração social do indivíduo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study investigated the effect of different ferrule heights on endodontically treated premolars. MATERIAL AND METHODS: Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey's post-hoc test was used for pair-wise comparisons (α=0.05). RESULTS: There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens. CONCLUSIONS: Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noncarious cervical lesions (NCCLs) are considered to be of multifactorial origin, normally associated with inadequate brushing. This study assessed the influence in vitro of simulated brushing on NCCL formation. Fifteen human premolars were submitted to brushing in the cementoenamel junction region, using hard-, medium- and soft-bristled brushes associated with a toothpaste of medium abrasiveness under a 200 g load, at a speed of 356 rpm for 100 minutes. The surface topography of the region was analyzed before and after brushing, by means of a laser interferometer, using "cut-off" values of 0.25 and considering roughness values in mm. The initial roughness (mm) results for dentin (D / bristle consistency: 1 - soft, 2 - medium and 3 - hard) were as follows: (D1) 1.25 ± 0.45; (D2) 1.12 ± 0.44; (D3) 1.05 ± 0.41. For enamel (E / bristle consistency: 1 - soft, 2 - medium and 3 - hard), the initial results were: (E1) 1.18 ± 0.35; (E2) 1.32 ± 0.25; (E3) 1.50 ± 0.38. After brushing, the following were the values for dentin: (D1) 2.32 ± 1.99; (D2) 3.30 ± 0.96; (D3) Over 500. For enamel, the values after brushing were: (E1) 1.37 ± 0.31; (E2) 2.15 ± 0.90; (E3) 1.22 ± 0.47. Based on the results of the ANOVA and Tukey statistical analyses (a = .05) it was concluded that soft, medium and hard brushes are not capable of abrading enamel, whereas dentin showed changes in surface roughness by the action of medium- and hard-bristled brushes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Owing to improvements in its mechanical properties and to the availability of shade and translucence resources, resin composite has become one of the most widely used restorative materials in present day Dentistry. The aim of this study was to assess the relation between the surface hardness of seven different commercial brands of resin composites (Charisma, Fill Magic, Master Fill, Natural Look, Opallis, Tetric Ceram, and Z250) and the different degrees of translucence (translucid, enamel and dentin). Vickers microhardness testing revealed significant differences among the groups. Z250 was the commercial brand that showed the best performance in the hardness test. When comparing the three groups assessed within the same brand, only Master Fill and Fill Magic presented statistically significant differences among all of the different translucencies. Natural Look was the only one that showed no significant difference among any of the three groups. Charisma, Opallis, Tetric Ceram and Z250 showed significant differences among some of the tested groups. Based on the results found in this study, it was not possible to establish a relation between translucence and the microhardness of the resin composites assessed. Depending on the material assessed, however, translucence variation did affect the microhardness values of the resin composites.