89 resultados para Occlusal sealants


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to deter-mine maximum bite force in molar and incisor regions in young Brazilian indigenous individuals, who have had a natural diet since birth, and compare the sample with white Brazilian individuals. To do this, individuals were paired one-to-one (same weight, height, and Class I facial pattern). A secondary purpose was to elucidate the relation between bite force and gender in both populations. Eighty-two Brazilians took part in this study. Participants were aged between 18 and 28 years and were divided into two groups: 41 Xingu indigenous individuals and 41 white Brazilian individuals, with 28 men and 13 women in each group. The inclusion criteria were: having complete dentition; normal occlusion; no neurological, psychiatric or movement disorders.; no reports of toothaches; having satisfactory periodontal health; absence of large facial skeletal alterations (typical Class II and Class III individuals); and no previous treatments using occlusal splints. To measure maximum bite force, a digital dynamometer model IDDK (Kratos-Equipamentos Industriais Ltda, Cotia, Sao Paulo, Brazil) was used, with a capacity of 1000 N, adapted for oral conditions. Assessments were made in the first molar (right and left) and central incisive regions. Results reveal that mean maximum bite forces in indigenous individuals of the right molar is 421 N, left molar 429 N and incisor region is 194 14 and for white individuals of the right molar is 410 N, left molar 422 N and incisor region is 117 N. Comparing indigenous with white individuals, maximal bite force showed a tendency of being greater in the indigenous group. It was observed that the incisor region showed statistical significance (p < 0.0005) but no significance was observed in the molar region. Moreover, indigenous men showed the highest bite force values. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of the current study were to analyze the effects of orofacial myofunctional therapy (OMT) on the treatment of subjects with associated articular and muscular temporomandibular disorders (TMD). Thirty subjects with associated articular and muscular TMD, according to the Research Diagnostic Criteria (RDCTTMD), were randomly divided into groups: 10 were treated with OMT (T group), 10 with an occlusal splint (OS group), and 10 untreated control group with TMD (SC). Ten subjects without TMD represented the asymptomatic group (AC). All subjects had a clinical examination and were interviewed to determine Helkimo`s Indexes (Di and Ai), the frequency and severity of signs and symptoms, and orofacial myofunctional evaluation. During the diagnostic phase, there were significant differences between groups T and AC. There were no significant differences between group T and OC and SC groups. During the final phase, groups T and OS presented significant improvement, however, the group T presented better results and differed significantly from group OS regarding the number of subjects classified as Aill; the severity of muscular pain and TMJ pain; the frequency of headache and the muscles and stomatognathic functions. The group T differed significantly from the SC group but no longer differed significantly from the AC group. OMT favored a significant reduction of pain sensitivity to palpation of all muscles studied but not for the TMJs; an increased measure of mandibular range of motion; reduced Helkimo`s Di and Ai scores; reduced frequency and severity of signs and symptoms; and increased scores for orofacial myofunctional conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Bruxism is characterized by repeated tooth grinding or clenching. The condition can occur in all age ranges and in both genders, being related or not to other oral habits. Objective: The objective of the present study was to investigate the occurrence of bruxism in children with nasal obstruction and to determine its association with other factors. Methods: Sixty children with nasal obstruction seen at the Otorhinolaryngology Outpatient Clinic of the University Hospital. of Ribeirao Preto participated in the study. The data were obtained using a pre-established questionnaire applied to the person responsible and by orofacial evaluation of the patient. The participants were divided into two groups: group with bruxism (GB) as reported by the relatives and with the presence of tooth wear detected by clinical evaluation, and group without bruxism (GWB), consisting of children with none of the two symptoms of bruxism mentioned above. Results: The presence of bruxism exceeded its absence in the sample studied (65.22%). There was no significant difference (P < 0.05) between groups regarding gender, phase of dentition, presence of hearing diseases, degree of malocclusion, or child behavior. Conclusion: Bruxism and deleterious oral habits such as biting behavior (objects, tips and nails) were significantly present, together with the absence of suction habits, in the children with nasal obstruction. (c) 2007 Elsevier Iretand Ltd. All. rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the effects of intrapulpal temperature changes induced by a quartz tungsten halogen (QTH) and a light emitting diode (LED) curing units on the metabolism of odontoblast-like cells. Methods: Thirty-six 0.5 mm-thick dentin discs obtained from sound human teeth were randomly assigned into three groups: QTH, LED and no light (control). After placement of the dentin discs in pulp chamber devices, a thermistor was attached to the pulpal surface of each disc and the light sources were applied on the occlusal surface. After registering the temperature change, odontoblast-like cells MDPC-23 were seeded on the pulpal side of the discs and the curing lights were again applied. Cell metabolism was evaluated by the MTT assay and cell morphology was assessed by SEM. Results: In groups QTH and LED the intrapulpal temperature increased by 6.4 degrees C and 3.4 degrees C, respectively. The difference between both groups was statistically significant (Mann-Whitney; P< 0.05). QTH and LED reduced the cell metabolism by 36.4% and 33.4%, respectively. Regarding the cell metabolism, no statistically significant difference was observed between both groups (Mann-Whitney; P> 0.05). However, when compared to the control, only QTH significantly reduced the cell metabolism (Mann-Whitney; P< 0.05). It was concluded that the irradiance of 0.5 mm-thick human dentin discs with a QTH in comparison to a LED curing unit promoted a higher temperature rise, which propagates through the dentin negatively affecting the metabolism of the underlying cultured pulp cells. (Am J Dent 2009;22:151-156).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study verified the effect of unilateral teeth extraction on the periodontal ligament in gerbils (Meriones unguiculatus). Ten adult male gerbils weighing about 50 g had induced occlusal alterations by upper left molar extractions while the other ten animals, only submitted to surgical stress, were considered as controls. The periodontal ligament was characterized by qualitative and quantitative analysis, histological description and histomorphometric quantification. Significant alterations were observed on the left side of the experimental group (P < 0.05), the hypofunctional region, when it was compared with the contralateral side and the corresponding region of the control group. Two months after occlusal alterations induced by unilateral teeth extraction, atrophic histological alterations and a decrease in the periodontal space on the ipsilateral side characterized the periodontal ligament. In this study it was possible to conclude that the gerbil can be used in experimental models attempting to correlate the periodontium`s biological response to various mechanical stresses, as the periodontal ligament was shown to be highly sensitive to occlusal alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Objectives: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. Study Design: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S3 Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. Results: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. ""Stretch mark""-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. Conclusion: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study. Lasers Surg. Med. 42:662-670, 2010. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this in vitro study was to compare the degree of microleakage of composite restorations performed by lasers and conventional drills associated with two adhesive systems. Materials and Methods: Sixty bovine teeth were divided into 6 groups (n = 10). The preparations were performed in groups 1 and 2 with a high-speed drill (HID), in groups 3 and 5 with Er:YAG laser, and in groups 4 and 6 with Er,Cr:YSGG laser. The specimens were restored with resin composite associated with an etch-and-rinse two-step adhesive system (Single Bond 2 [SB]) (groups 1, 3, 4) and a self-etching adhesive (One-Up Bond F [OB]) (groups 2, 5, 6). After storage, the specimens were polished, thermocycled, immersed in 50% silver nitrate tracer solution, and then sectioned longitudinally. The specimens were placed under a stereomicroscope (25X) and digital images were obtained. These were evaluated by three blinded evaluators who assigned a microleakage score (0 to 3). The original data were submitted to Kruskal-Wallis and Mann-Whitney statistical tests. Results: The occlusal/enamel margins demonstrated no differences in microleakage for all treatments (p > 0.05). The gingival/dentin margins presented similar microleakage in cavities prepared with Er:YAG, Er,Cr:YSGG, and HD using the etch-and-rinse two-step adhesive system (SB) (p > 0.05); otherwise, both Er:YAG and Er,Cr:YSGG lasers demonstrated lower microleakage scores with OB than SB adhesive (p < 0.05). Conclusion: The microleakage score at gingival margins is dependent on the interaction of the hard tissue removal tool and the adhesive system used. The self-etching adhesive system had a lower microleakage score at dentin margins for cavities prepared with Er:YAG and Er,Cr:YSGG than the etch-and-rinse two-step adhesive system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of an additional Er:YAG laser conditioning step after laser cavity preparations, on the microleakage of class V composite restorations. Forty-eight bovine incisors were randomly divided into four groups: G1(control) cavities prepared with bur, G2- cavities prepared with laser (400 mJ/2 Hz), G3-cavities prepared and subsequently conditioned with Er:YAG laser (60 mJ/2 Hz); G4-idem for G3, but the laser conditioning was carried out without water-spray. All the cavities were restored using Clearfill SE Bond (R) and Z-250 (R) composite resin. The samples were thermal cycled for 700 cycles and then immersed in 50% silver nitrate solution. The sectioned restorations were exposed to a photoflood lamp to reveal silver nitrate penetration. The Kruskal-Walis one-way analyses of variance test and post hoc Wilcoxon pair-wise comparison were used to compare microleakage degrees. At the gingival margin G2 showed a lower microleakage mean than the control bur-prepared cavities (p = 0.0003). At occlusal margins there were no statistically significant differences between the groups (p = 0.28). It may be concluded that Er:YAG laser class V cavity preparations do not need to be followed by an additional laser conditioning step to result in levels of microleakage similar to or lower than those obtained after bur preparations. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 87B: 538-543, 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adhesive performance on deproteinized dentin of different self-adhesive resin cements was evaluated through microtensile bond strength (mu TBS) analysis and scanning electron microscopy (SEM). Occlusal dentin of human molars were distributed into different groups, according to the categories: adhesive cementation with two-step bonding systems-control Groups (Adper Single Bond 2 + RelyX ARC/3M ESPE; One Step Plus + Duolink/Bisco; Excite + Variolink I/Ivoclar Vivadent) and self-adhesive cementation-experimental groups (Rely X Unicem/3M ESPE; Biscem/Bisco; MultiLink Sprint/Ivoclar Vivadent). Each group was subdivided according to the dentin approach to: alpha, maintenance of collagen fibers and beta, deproteinization. The mean values were obtained, and submitted to ANOVA and Tukey test. Statistical differences were obtained to the RelyX Unicem groups (alpha = 13.59 MPa; beta = 30.19 MPa). All the BIS Group specimens failed before the mechanical tests. Dentinal deproteinization provided an improved bond performance for the self-adhesive cement Rely X Unicem, and had no negative effect on the other cementing systems studied. (C) 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 98B: 387-394, 2011.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the qualitative and quantitative differences on dental plaque formation on two different roughness titanium implant surfaces, i.e. machined and titanium plasma sprayed, as well as the amount of plaque removal by regular toothbrushing after 72-hour plaque accumulation. Methods: Eight systemically healthy subjects were recruited from the patient pool of a private dental practice. All patients underwent oral hygiene instruction and full mouth prophylaxis. Subsequently, maxillary casts from all patients were obtained and removable 0.7 mm-thick acetate stents without occlusal contact points were fabricated to support four titanium specimens of 4x2x2 mm divided into two groups (machined and plasma sprayed). Subjects were instructed to wear the stents for 72 hours, full time, removing them only during regular oral hygiene. Subsequently, the appliances were immediately repositioned and then the test side was brushed for 20 seconds. At the end of the 72-hour period, the stents were removed and prepared for microbiological analysis. Results: Both machined and plasma sprayed brushed surfaces presented statistically significant fewer bacteria than non-brushed surfaces. Similarly, regarding surface roughness, machined surfaces presented a total number of bacteria significantly smaller than those presented by plasma sprayed surfaces (P< 0.05). Statistically, the non-brushed machined turned surfaces presented a greater amount of Streptoccocus sp. when compared to the brushed machined surfaces. It was concluded that rough surfaces accumulated more dental plaque than polished surfaces. Both brushed surfaces presented less plaque accumulation, however, implant brushing was more effective on machined surfaces. (Am J Dent 2008;21:318-322).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to test the effect of adhesive temperature on the bond strength to dentin (mu TBS) and silver nitrate uptake (SNU) of an ethanol/water (Adper Single Bond 2 [SB]) and an acetone-based (Prime&Bond 2.1 [PB]) etch-and-rinse adhesive system. Methods: The bottles of each adhesive were kept in various temperatures (5 degrees C, 20 degrees C, 37 degrees C and 50 degrees C) for 1 h previously to its application in the occlusal demineralized dentin of 40 molars. Bonded sticks (0.8 mm(2)) were tested in tension (0.5 mm/min) immediately (IM) or after 6 months (6 M) of water storage. Two bonded sticks from each hemi-tooth were immersed in silver nitrate and analyzed by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey`s test (alpha = 0.05). Results: No significant difference in mu TBS was detected for both adhesives at 5 degrees C and 20 degrees C. The highest bond strength for PB was observed in the 37 degrees C group while for SB it was in the 50 degrees C. Significant reductions of bond strengths were observed for PB at 37 degrees C and SB at 50 degrees C after 6 M of water storage. Silver nitrate deposition was seen in all hybrid layers, irrespective of the group. Lower silver nitrate deposition (water trees) in the adhesive layer was seen for PB and SB at higher temperatures. Conclusions: The heating or refrigeration of the adhesives did not improve their resin-dentin bond resistance to water degradation over time. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present randomized, controlled prospective study evaluated the histomorphological response of human dental pulps capped with two grey mineral trioxide aggregate (MTA) compounds. Pulp exposures were performed on the occlusal floor of 40 human permanent pre-molars. The pulp was capped either with ProRoot (Dentsply) or MTA-Angelus (Angelus) and restored with zinc oxide eugenol cement. After 30 and 60 days, teeth were extracted and processed for histological examination and the effects on the pulp were scored. The data were subjected to Kruskal-Wallis and Conover tests (alpha = 0.05). In five out of the 40 teeth bacteria were present in pulp tissue. No significant difference was observed between the two materials (P > 0.05) in terms of overall histological features (hard tissue bridge, inflammatory response, giant cells and particles of capping materials). Overall, 94% and 88% of the specimens capped with MTA-Angelus and ProRoot, respectively, showed either total or partial hard tissue bridge formation (P > 0.05). Both commercial materials ProRoot (Dentsply) and MTA-Angelus (Angelus) produced similar responses in the pulp when used for pulp capping in intact, caries-free teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare the response of human dental pulp capped with a mineral trioxide aggregate (MTA) and Ca(OH)(2) powder. Methods and Material: Pulp exposures were performed on the occlusal floor of 40 permanent premolars. The pulp was then capped with either Ca(OH)(2) powder (CH) or MTA and restored with resin composite. After 30 days (groups CH30 and MTA30) and 60 days (groups CH60 and MTA60), the teeth were extracted and processed for HE and categorized in a histological score system. The data were subjected to Kruskal-Wallis and Conover tests (alpha=0.05). Results: In regard to dentin bridge formation, CH30 showed a tendency towards superior performance compared to MTA30 (p>0.05), although the products showed comparable results at day 60. In the item ""Inflammation"" and ""General State of the Pulp"" (p>0.05), CH showed a tendency towards presenting a higher inflammatory response. In the item ""Other Pulpal Findings,"" MTA and Ca(OH)(2) showed equal and excellent performance after 30 and 60 days (p>0.05). Conclusion: After 30 days, Ca(OH)(2) powder covered with calcium hydroxide cement showed faster hard tissue bridge formation compared to MTA. After 60 days, Ca(OH)(2) powder or NITA materials showed a similar and excellent histological response with the formation of a hard tissue bridge in almost all cases with low inflammatory infiltrate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study investigated the prevalence of dental wear in 12-year-old adolescents using a modification of the tooth wear index (TWI). The modifications were proposed in order to fit with the World Health Organization standard, thus allowing application of the index in broad epidemiological surveys. Study design: An epidemiological cross-sectional survey was performed by trained, calibrated examiners, using a modified version of the TWI. Methods: Urban elementary schools were chosen because they provide a fair representation of the city`s population in terms of socio-economic status. The sample included 295 adolescents, selected randomly and systematically. Dental wear was assessed by calibrated examiners (kappa > 0.85), using a modified version of the TWI. This modified version includes a code for teeth restored due to wear, and another code for teeth that cannot be assessed. In addition, it does not differentiate the depth of dentine involvement. Proportions and confidence intervals were used to describe the prevalence of dental wear. Mann-Whitney test was used to detect differences in the degree of dental wear between mates and females. The level of statistical significance was set at 5%. Results: In total, 24,780 dental surfaces were evaluated. Among these surfaces, 73.10% did not present dental wear, 24.10% had incipient lesions, 2.46% had moderate lesions and 0.34% had been restored. No severe lesions were detected. Tooth wear was mainly seen on the occlusal/incisal surfaces (26.55%), involving enamel or enamel-dentine, but not the secondary dentine or pulp. The prevalence of dental wear was 26.90%. Considering the different teeth, wear was present in 53.22% of incisors, 50.51% of canines, 10.17% of premolars and 10.85% of molars. The prevalence of the different degrees of dental wear was similar in mates and females (P > 0.05). Conclusion: The modified TWI seems to bean effective toot for use in broad epidemiological surveys, due to easier calibration and high reproducibility rates. (C) 2008 The Royal Institute of Public Health. Published by Elsevier Ltd. All rights reserved.