51 resultados para Helmes-Hayes, Rick: The Vertical mosaic revisited


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The trapezium is often a better approximation for the FinFET cross-section shape, rather than the design-intended rectangle. The frequent width variations along the vertical direction, caused by the etching process that is used for fin definition, may imply in inclined sidewalls and the inclination angles can vary in a significant range. These geometric variations may cause some important changes in the device electrical characteristics. This work analyzes the influence of the FinFET sidewall inclination angle on some relevant parameters for analog design, such as threshold voltage, output conductance, transconductance, intrinsic voltage gain (A V), gate capacitance and unit-gain frequency, through 3D numeric simulation. The intrinsic gain is affected by alterations in transconductance and output conductance. The results show that both parameters depend on the shape, but in different ways. Transconductance depends mainly on the sidewall inclination angle and the fixed average fin width, whereas the output conductance depends mainly on the average fin width and is weakly dependent on the sidewall inclination angle. The simulation results also show that higher voltage gains are obtained for smaller average fin widths with inclination angles that correspond to inverted trapeziums, i.e. for shapes where the channel width is larger at the top than at the transistor base because of the higher attained transconductance. When the channel top is thinner than the base, the transconductance degradation affects the intrinsic voltage gain. The total gate capacitances also present behavior dependent on the sidewall angle, with higher values for inverted trapezium shapes and, as a consequence, lower unit-gain frequencies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to analyze the range of movement of the ankle and the vertical ground reaction force involved in gait among diabetic patients with and without peripheral neuropathy. Sample and Method: 36 individuals were divided into three groups: Control group - CG: 10 individuals without diabetes, Diabetic group - DG: 10 individuals with diabetes without peripheral neuropathy and Neuropathy, and Diabetic neuropathic group - DNG: 16 individuals with diabetes and peripheral diabetic neuropathy. Gait - AMTI (R) OR6/6m and range of tibiotarsal joint movement - System Vicom 640 (R) was carried out in all the participants. Results: The first and second vertical ground reaction force peaks were statistically higher in the neuropathy group, and the range of ankle motion was lower in the Diabetes and Neuropathy groups. Conclusion: The range of movement of the tibiotarsal joint is lower in diabetics, regardless of the presence or absence of peripheral neuropathy, and diabetics with peripheral neuropathy show an increase in the first and second vertical ground reaction force peaks during walking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS (R), which is a novel biomaterial for the treatment of this complication. Design A case series of 25 patients. Methods Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix biomaterial to help fistula healing. Main outcome measures Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. Results In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Conclusions Endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix-is safe and effective for the treatment of gastrocutaneous fistula after RYGB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To histomorphometrically investigate the repair of critical size defects (CSDs) and bone augmentation in cranial walls using block of sintered bovine-derived anorganic bone (sBDAB) graft. Forty guinea-pigs were divided into test (n=20) and CSD control (n=20) groups. In each animal, a full-thickness bone defect with 9.5 mm diameter was made in the frontal bone. The defects were filled with an sBDAB block soaked in blood in the test group and with blood clot in the CSD control group. The skulls were collected at 0 h (n=2) and 30, 90 and 180 days (n=6/group and period) postoperatively. The volume density and total volume of newly formed bone, sBDAB, blood vessels and connective tissue, vertical thickness of removed bone plug, sBDAB block and graft area were evaluated. The vertical thickness of the adapted sBDAB block was 3.8 times higher than that of the removed bone plug and did not show significant difference between periods, filling in average 29.8% of the total graft region. The sBDAB block exhibited complete osseointegration with the borders of the defect at 90 days. At 90 and 180 days, the vertical thickness of the graft was 279% in the average, and the total volume of bone augmentation was, respectively, 78.8% and 148.5% higher compared with the removed bone plug. The defects of the CDS control group showed limited osteogenesis and filling by connective tissue plus tegument. The sBDAB block can be used to promote repair of CSDs and bone augmentation in the craniomaxillofacial region, due to its good osteoconductive and slow resorptive properties. To cite this article:Cestari TM, Granjeiro JM, de Assis GF, Garlet GP, Taga R. Bone repair and augmentation using block of sintered bovine-derived anorganic bone graft in cranial bone defect model.Clin. Oral Impl. Res. 20, 2009; 340-350.doi: 10.1111/j.1600-0501.2008.01659.x.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report describes the nonsurgical, nonextraction therapy of a 16-year-old boy with a skeletal Class III malocclusion, a prognathic mandible, and a retrusive maxilla. He was initially classified as needing orthognathic surgery, but he and his parents wanted to avoid that. The Class III malocclusion was corrected with a rapid palatal expander and a maxillary protraction mask followed by nonextraction orthodontic treatment with fixed appliances, combined with short Class III and vertical elastics in the anterior area. The height of the maxillary alveolar process and the vertical face height were slightly increased with treatment. Class I molar and canine relationships were achieved, and the facial profile improved substantially. (Am J Orthod Dentofacial Orthop 2009; 136: 736-45)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The aim of this study was to histomorphometrically evaluate the influence of interimplant distances (ID) and implant placement depth on bone remodeling around contiguous Morse cone connection implants with `platform-shifting` in a dog model. Material and methods Bilateral mandibular premolars of six dogs were extracted, and after 12 weeks, each dog received 8 implants, four placed 1.5 mm subcrestally (SCL) on one side of the mandible and four placed equicrestally (ECL) on the other side, alternating the ID of 2 and 3 mm. The experimental groups were SCL with IDs of 2 mm (2 SCL) and 3 mm (3 SCL) and ECL with IDs of 2 mm (2 ECL) and 3 mm (3 ECL). Metallic crowns were immediately installed. After 8 weeks, the animals were euthanized and histomorphometric analyses were performed to compare bone remodeling in the groups. Results The SCL groups` indices of crestal bone resorption were significantly lower than those of ECL groups. In addition, the vertical bone resorption around the implants was also numerically inferior in the SCL groups, but without statistical significance. No differences were obtained between the different IDs. All the groups presented similar good levels of bone-to-implant contact and histological bone density. Conclusion The subcrestal placement of contiguous Morse cone connection implants with `platform shifting` was more efficient in preserving the interimplant crestal bone. The IDs of 2 and 3 mm did not affect the bone remodeling significantly under the present conditions. To cite this article:Barros RRM, Novaes AB Jr., Muglia VA, Iezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 371-378.doi: 10.1111/j.1600-0501.2009.01860.x.