53 resultados para Dynamic difficulty adjustment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The identification of regulatory T cells (Treg cells) as CD4(+)CD25(high) cells may be upset by the increased frequency of activated effector T cells (Teff cells) in inflammatory diseases such as systemic lupus erythematosus (SLE). This study aimed to evaluate the frequency of T-cell subsets according to the expression of CD25 and CD127 in active (A-SLE) and inactive SLE (I-SLE). Methods: Peripheral blood mononuclear cells (PBMCs) from 26 A-SLE patients (SLE Disease Activity Index (SLEDAI) = 10.17 +/- 3.7), 31 I-SLE patients (SLEDAI = 0), and 26 healthy controls (HC) were analysed by multicolour flow. cytometry. Results: CD25(high) cell frequency was increased in A-SLE (5.2 +/- 5.7%) compared to I-SLE (3.4 +/- 3.4%) and HC (1.73 +/- 0.8%) (p < 0.01). However, the percentage of FoxP3(+) cells in the CD25(high) subset was decreased in A-SLE (24.6 +/- 16.4%) compared to I-SLE (33.7 +/- 16) and HC (45 +/- 25.1%) (p < 0.01). This was partly due to the increased frequency of Teff cells (CD25(high)CD127(+)FoxP3(empty set)) in A-SLE (10.7 +/- 7.3%) compared to I-SLE (8.5 +/- 6.5) and HC (6.1 +/- 1.8%) (p = 0.02). Hence the frequency of Treg cells (CD25(+/high)CD127(low/empty set)FoxP3(+)) was equivalent in A-SLE (1.4 +/- 0.8%), I-SLE (1.37 +/- 1.0%), and HC (1.13 +/- 0.59%) (p = 0.42). A-SLE presented an increased frequency of CD25(+)CD127(+)FoxP3(+) and CD25(empty set)FoxP3(+)CD127(low/empty set) T cells, which may represent intermediate phenotypes between Treg and Teff cells. Conclusions: The present study has provided data supporting normal Treg cell frequency in A-SLE and I-SLE as well as increased frequency of Teff cells in A-SLE. This scenario reflects a Treg/Teff ratio imbalance that may favour the inflammatory phenotype of the disease. In addition, the increased frequency of T cells with putative intermediate phenotypes may be compatible with a highly dynamic immune system in SLE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the growing evidence of poor psychosocial adjustment, at present there is no formal method of assessment of social adjustment in patients with temporal lobe epilepsy (TLE). First, we assessed social adjustment in patients with TLE using a self-report questionnaire and compared the results with those from quality-of-life (QOL) scales. Second, we verified the influence of cognitive performance and clinical variables of epilepsy on social adjustment and QOL We evaluated 35 people with TLE and 38 healthy controls. Patients had worse social adjustment, and it was correlated with worse perception of cognitive function. Attention and verbal memory dysfunctions were negatively correlated with social adjustment. However, there was no significant correlation between cognitive performance and QOL Regarding clinical variables, persons with left TLE showed worse social adjustment and patients with frequent seizures showed worse QOL These findings indicate the relevance of evaluating social adjustment and emphasize the importance of cognitive rehabilitation to improved social adjustment. (c) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain a high quality EMG acquisition, the signal must be recorded as far away as possible from muscle innervations and tendon zones, which are known to shift during dynamic contractions. This study describes a methodology, using commercial bipolar electrodes, to identify better electrode positions for superficial EMG of lower limb muscles during dynamic contractions. Eight female volunteers participated in this study. Myoelectric signals of the vastus lateralis, gastrocnemius medialis, peroneus longus and tibialis anterior muscles were acquired during maximum isometric contractions using bipolar electrodes. The electrode positions of each muscle were selected assessing SENIAM and then, other positions were located along the length of muscle up and down the SENIAM site. The raw signal (density), the linear envelopes, the RMS value, the motor point site, the position of the IZ and its shift during dynamic contractions were taken into account to select and compare electrode positions. For vastus lateralis and peroneus longus, the best sites were 66% and 25% of muscle length, respectively (similar to SENIAM location). The position of the tibialis anterior electrodes presented the best signal at 47.5% of its length (different from SENIAM location). The position of the gastrocnemius medialis electrodes was at 38% of its length and SENIAM does not specify a precise location for signal acquisition. The proposed method should be considered as another methodological step in every EMG study to guarantee the quality of the signal and subsequent human movement interpretations. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjustments during postural control have been recognized in the process of the integration of movement and cognition. The objective of the present work was to describe postural changes and to verify if there is a correlation between postural adjustment and attention span in 7-month-old infants during 1 min of viewing an animated puppet. Method: Twenty-nine healthy infants (14 males) born from 31 to 39 weeks (median 36) were placed in a prone position and filmed watching a puppet during I min. The analysis of the images allowed us to catalogue the changes in position, the frequency of these changes, and the attention span. The following items were quantified: total number of infant positions, positions with weight transfer, changes in support, axis, decubitus, trunk and cervical movements, timing and pauses in visual attention. Results: Twenty-one infants stayed in the prone position during most of the recording, and eight chose sitting position before starting the session. Two groups were studied according to the main position throughout the filming, one in prone and the other in sitting positions, although they could rolling or crawling. For prone group the attention span was positively correlated with the number of positions with weight transfer (r = 0.53, p = 0.04), negatively correlated with trunk movements (r = -0.63, p = 0.01), and not correlated with birth or current weight. This work suggests that changes in the trunk movements and weight transfer are different traits related to the attention in 7-month-old infants. (C) 2008 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this study, we aimed to evaluate the long-term stability of anterior open-bite treatment with occlusal adjustment and the dentinal sensitivity caused by this procedure in the long term. Methods: The sample comprised 17 open-bite patients who experienced relapse of the negative vertical overbite after orthodontic treatment and were retreated with occlusal adjustment. The cephalometric changes were evaluated on lateral cephalograms obtained before and after the occlusal adjustment and in the long term (mean, 3.4 years after occlusal adjustment). Dentinal sensitivity was also evaluated before the occlusal adjustment, and 1.35 months, 4.61 months, and 3.4 years later. The cephalometric statuses between the 3 evaluations were compared with analysis of variance (ANOVA) and Tukey tests. The percentages of clinically significant relapse were calculated. To compare dentinal sensitivity at the several stages, nonparametric Friedman and Wilcoxon tests were performed. Results: Statistically significant relapse of anterior open bite occurred in 33.3% of the patients. Those who had the procedure before 21 years of age were most likely to experience relapse. Dentinal sensitivity remained within the normal range in the long term. Conclusions: Despite the statistically significant relapse of anterior open bite, clinically significant stability was found in 66.7% of the patients. (Am J Orthod Dentofacial Orthop 2010; 138:14.e1-14.e7)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to evaluate the cephalometric and occlusal changes, the functional occlusion, and the dentinal sensitivity of anterior open-bite treatment with occlusal adjustment. Methods: The sample comprised 20 patients who experienced relapse of the anterior open bite (mean, -1.06 mm). Occlusal adjustment was performed until a positive overbite was established. Cephalometric changes were evaluated on lateral cephalograms taken before and after the occlusal adjustment. The functional occlusion analysis consisted of evaluating immediate anterior and canine guidance and the number of teeth in contact before and after the procedure. Dentinal sensitivity was evaluated before, shortly after, and 4.61 months after the occlusal adjustment. Pretreatment and posttreatment cephalometric changes and the number of teeth in contact were compared with dependent t tests. Percentages of anterior and canine guidance before and after the adjustment procedure were compared with the McNemar test. To compare dentinal sensitivity at several stages, the nonparametric Friedman test was used, followed by the Wilcoxon test. Results: Significant increases in overbite and mandibular protrusion were seen, as were significant decreases in apical base discrepancy, facial convexity, and growth pattern angles. The percentages of immediate anterior and canine guidance increased significantly, as did the number of teeth with occlusal contacts. Dentinal sensitivity increased immediately after the adjustment but decreased to normal levels after 4.61 months. Conclusions: Occlusal adjustment is a viable treatment alternative for some open-bite patients; it establishes positive vertical overbite and improves the functional occlusion with only transient dentinal sensitivity.