142 resultados para Cone-beam computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: We present an iterative framework for CT reconstruction from transmission ultrasound data which accurately and efficiently models the strong refraction effects that occur in our target application: Imaging the female breast. Methods: Our refractive ray tracing framework has its foundation in the fast marching method (FNMM) and it allows an accurate as well as efficient modeling of curved rays. We also describe a novel regularization scheme that yields further significant reconstruction quality improvements. A final contribution is the development of a realistic anthropomorphic digital breast phantom based on the NIH Visible Female data set. Results: Our system is able to resolve very fine details even in the presence of significant noise, and it reconstructs both sound speed and attenuation data. Excellent correspondence with a traditional, but significantly more computationally expensive wave equation solver is achieved. Conclusions: Apart from the accurate modeling of curved rays, decisive factors have also been our regularization scheme and the high-quality interpolation filter we have used. An added benefit of our framework is that it accelerates well on GPUs where we have shown that clinical 3D reconstruction speeds on the order of minutes are possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

FUNDAMENTO: Apesar de algumas evidências sugerirem associação entre a exposição de uma tecnologia na literatura científica e sua difusão na prática clínica, poucos estudos avaliaram essa associação. OBJETIVO: O objetivo deste estudo é analisar se o padrão de publicação científica sobre duas tecnologias competitivas utilizadas na avaliação da doença arterial coronária (DAC) reflete o que ocorre na prática clínica. MÉTODOS: Avaliou-se o número de artigos científicos publicados anualmente na literatura médica (interesse científico global na tecnologia) sobre duas tecnologias utilizadas na avaliação da doença arterial coronária: tomografia computadorizada por feixe de elétrons e tomografia computadorizada com múltiplos detectores. Foi também analisado o número de países que publicam anualmente artigos científicos sobre essas tecnologias (interesse geográfico na tecnologia). RESULTADOS: A tomografia computadorizada por feixe de elétrons (electron beam computed tomography - EBCT) apresentou ápice de "interesse científico global" em 2001, com 127 artigos publicados. Após esse ápice, o "interesse científico global" diminuiu cerca de 50% em 2008. Em oposição, o "interesse científico global" pela tomografia computadorizada com múltiplos detectores (multidetector computed tomography - MDCT) aumentou progressivamente até 2007, com 454 artigos publicados nesse ano. O "interesse científico geográfico" pela EBCT teve ápice em 2002, com 14 países publicando sobre essa tecnologia. Após esse ápice, "o interesse científico geográfico" declinou em quase 25% até 2008, com 11 países publicando artigos sobre essa tecnologia. Em oposição, o "interesse científico geográfico" pela MDCT aumentou progressivamente até 2008, com 37 países publicando artigos sobre ela. CONCLUSÃO: A literatura científica médica é compatível com a substituição da EBCT pela MDCT na avaliação da DAC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The MASS IV-DM Trial is a large project from a single institution, the Heart Institute (InCor), University of Sao Paulo Medical School, Brazil to study ventricular function and coronary arteries in patients with type 2 diabetes mellitus. Methods/Design: The study will enroll 600 patients with type 2 diabetes who have angiographically normal ventricular function and coronary arteries. The goal of the MASS IV-DM Trial is to achieve a long-term evaluation of the development of coronary atherosclerosis by using angiograms and coronary-artery calcium scan by electron-beam computed tomography at baseline and after 5 years of follow-up. In addition, the incidence of major cardiovascular events, the dysfunction of various organs involved in this disease, particularly microalbuminuria and renal function, will be analyzed through clinical evaluation. In addition, an effort will be made to investigate in depth the presence of major cardiovascular risk factors, especially the biochemical profile, metabolic syndrome inflammatory activity, oxidative stress, endothelial function, prothrombotic factors, and profibrinolytic and platelet activity. An evaluation will be made of the polymorphism as a determinant of disease and its possible role in the genesis of micro- and macrovascular damage. Discussion: The MASS IV-DM trial is designed to include diabetic patients with clinically suspected myocardial ischemia in whom conventional angiography shows angiographically normal coronary arteries. The result of extensive investigation including angiographic follow-up by several methods, vascular reactivity, pro-thrombotic mechanisms, genetic and biochemical studies may facilitate the understanding of so-called micro- and macrovascular disease of DM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to evaluate this ""response-to-injury"" hypothesis of atherosclerosis by studying the interaction between systolic blood pressure (SBP) and LDL-cholesterol (LDL-C) in predicting the presence of coronary artery calcification (CAC) in asymptomatic men. We Studied 526 men (46 +/- 7 years of age) referred for electron-beam tomography (EBT) exam. The prevalence of CAC was determined across LDL-C tertiles (low: <115 mg/dl; middle: 115-139 mg/dl high: >= 140 mg/dl) within tertiles of SBP (low: <121 mmHg; middle: 121-130 mmHg; high: >= 131 mmHg). CAC was found in 220 (42%) men. There was no linear trend in the presence of CAC across LDL-C tertiles in the low (p = 0.6 for trend) and middle (p = 0.3 for trend) SBP tertile groups, respectively. In contrast, there was a significant trend for increasing CAC with increasing LDL-C (1st: 44%; 2nd: 49%; 3rd: 83%; p < 0.0001 for trend) in the high SBP tertile group. In multivariate logistic analyses (adjusting for age, smoking, triglyceride levels, HDL-cholesterol levels, body mass index, and fasting glucose levels), the odds ratio for any CAC associated with increasing LDL-C was significantly higher in those with highest SBP levels, whereas no such relationship was observed among men with SBP in the lower two tertiles. An interaction term (LDL-C x SBP) incorporated in the multivariate analyses was statistically significant (p = 0.038). The finding of an interaction between SBP and LDL-C relation to CAC in asymptomatic men support the response-to-injury model of atherogenesis. (C) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluate, through computerized tomography, canal transportation and centring ability of RaCe rotary instruments after preparation of mesiobuccal root canals in maxillary molar teeth. Twenty-seven teeth were submitted to three cone beam tomographic analyses, one preoperatively, and two after preparation with file size 35, .02 taper and size 50, .02 taper. Canal transportation and centring ability were measured with reference to the distance between the noninstrumented portion of the root canals and the mesial and distal periphery of the root, compared with images obtained after the preparation with size 35 and 50 instruments. Canal transportation after preparation with the size 35 file was 0.030 +/- 0.253 mm and after the size 50 file was 0.057 +/- 0.317 mm. The centring ratio values after preparation with the size 35 file was 0.42 +/- 0.32 and after the size 50 file was 0.54 +/- 0.29, with no significant statistical difference between the groups. RaCe instruments allowed the preparation of curved root canals with preparation diameters larger than those normally used with minimal canal transportation and adequate centring ability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gamma ray tomography experiments have been carried out to detect spatial patterns in the porosity in a 0.27 m diameter column packed with steel Rashig rings of different sizes: 12.6, 37.9, and 76 mm. using a first generation CT system (Chen et al., 1998). A fast Fourier transform tomographic reconstruction algorithm has been used to calculate the spatial variation over the column cross section. Cross-sectional gas porosity and solid holdup distribution were determinate. The values of cross-sectional average gas porosity were epsilon=0.849, 0.938 and 0.966 for the 12.6, 37.9, and 76 mm rings, respectively. Radial holdup variation within the packed bed has been determined. The variation of the circumferentially averaged gas holdup in the radial direction indicates that the porosity in the column wall region is a somewhat higher than that in the bulk region, due to the effect of the column wall. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our aim was to document the benefits of three dimensional finite element model generations from computed tomography data as well as the realistic creation of all oral structures in a patient. The stresses resulting from the applied load in our study did not exceed the structure limitations, suggesting a clinically acceptable physiological condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. Technical note with illustrative case reports. Respiratory intensive care unit. Patients with acute respiratory distress syndrome. Lung recruitment and PEEP titration maneuver. Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse < 10%) were 19 and 17 cmH(2)O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Quantitative computed tomography (qCT)-based assessment of total lung weight (M(lung)) has the potential to differentiate atelectasis from consolidation and could thus provide valuable information for managing trauma patients fulfilling commonly used criteria for acute lung injury (ALI). We hypothesized that qCT would identify atelectasis as a frequent mimic of early posttraumatic ALI. Methods: In this prospective observational study, M(lung) was calculated by qCT in 78 mechanically ventilated trauma patients fulfilling the ALI criteria at admission. A reference interval for M(lung) was derived from 74 trauma patients with morphologically and functionally normal lungs (reference). Results are given as medians with interquartile ranges. Results: The ratio of arterial partial pressure of oxygen to the fraction of inspired oxygen was 560 (506 to 616) mmHg in reference patients and 169 (95 to 240) mmHg in ALI patients. The median reference M(lung) value was 885 (771 to 973) g, and the reference interval for M(lung) was 584 to 1164 g, which matched that of previous reports. Despite the significantly greater median M(lung) value (1088 (862 to 1,342) g) in the ALI group, 46 (59%) ALI patients had M(lung) values within the reference interval and thus most likely had atelectasis. In only 17 patients (22%), Mlung was increased to the range previously reported for ALI patients and compatible with lung consolidation. Statistically significant differences between atelectasis and consolidation patients were found for age, Lung Injury Score, Glasgow Coma Scale score, total lung volume, mass of the nonaerated lung compartment, ventilator-free days and intensive care unit-free days. Conclusions: Atelectasis is a frequent cause of early posttraumatic lung dysfunction. Differentiation between atelectasis and consolidation from other causes of lung damage by using qCT may help to identify patients who could benefit from management strategies such as damage control surgery and lung-protective mechanical ventilation that focus on the prevention of pulmonary complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies evaluating radiologic aspects, local complications, and structural alterations of the paranasal sinus in patients with mucosal leishmaniasis (ML) are lacking The aim of this study was to analyze alterations of the paranasal sinuses in patients with ML by using computed tomography (CT) scans This prospective study evaluated 26 patients in Brazil with ML Nom December 2008 through June 2009 All patients underwent CT scans of the paranasal sinuses Paranasal thickening was observed in 25 patients (96%) Nasal perforation was observed in 17 patients (65%) Those patients who received re-treatment showed more abnormalities on CT scan than cured patients (P < 0 05) Complications of ML are not limited to the nasal mucosa but extend to the paranasal sinuses. Mucosa! thickening. pacified air cells. bony remodeling, and bony thickening caused by inflammatory steals of the sinus cavity walls are CT findings suggestive of chronic sinusitis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: This study evaluated the interobserver reliability of plain radiograpy versus computed tomography (CT) for the Universal and AO classification systems for distal radius fractures. Patients and methods: Five observers classified 21 sets of distal radius fractures using plain radiographs and CT independently. Kappa statistics were used to establish a relative level of agreement between observers for both readings. Results: Interobserver agreement was rated as moderate for the Universal classification and poor for the AO classification. Reducing the AO system to 9 categories and to its three main types reliability was raised to a ""moderate"" level. No difference was found for interobserver reliability between the Universal classification using plain radiographs and the Universal classification using computed tomography. Interobserver reliability of the AO classification system using plain radiographs was significantly higher than the interobserver reliability of the AO classification system using only computed tomography. Conclusion: From these data, we conclude that classification of distal radius fractures using CT scanning without plain radiographs is not beneficial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P < 0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To assess the cost effectiveness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in patients with Hodgkin`s lymphoma (HL) with unconfirmed complete remission (CRu) or partial remission (PR) after first-line treatment. Patients and Methods One hundred thirty patients with HL were prospectively studied. After treatment, all patients with CRu/PR were evaluated with FDG-PET. In addition, PET-negative patients were evaluated with standard follow-up, and PET-positive patients were evaluated with biopsies of the positive lesions. Local unit costs of procedures and tests were evaluated. Cost effectiveness was determined by evaluating projected annual economic impact of strategies without and with FDG-PET on HL management. Results After treatment, CRu/PR was observed in 50 (40.0%) of the 127 patients; the sensitivity, specificity, and positive and negative predictive values of FDG-PET were 100%, 92.0%, 92.3%, and 100%, respectively (accuracy of 95.9%). Local restaging costs without PET were $350,050 compared with $283,262 with PET, a 19% decrease. The incremental cost-effectiveness ratio is -$3,268 to detect one true case. PET costs represented 1% of total costs of HL treatment. Simulated costs in the 974 patients registered in the 2008 Brazilian public health care database showed that the strategy including restaging PET would have a total program cost of $56,498,314, which is $516,942 less than without restaging PET, resulting in a 1% cost saving. Conclusion FDG-PET demonstrated 95.9% accuracy in restaging for patients with HL with CRu/PR after first-line therapy. Given the observed probabilities, FDG-PET is highly cost effective and would reduce costs for the public health care program in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lymphangiomas are benign nonencapsulated lesions composed of sequestered noncommunicating lymphoid tissue lined by lymphatic endothelium and are thought to be caused by congenital obstruction of lymphatic drainage. They are subclassified by vessel size, such as the capillary, which is rare and located in subcutaneous tissue, cavernous (located about the mouth and tongue), and cystic (cystic hygromas). The cystic hygromas show a predilection for the neck (75%) and maxilla (20%), and the remaining 5% arise in rare locations such as the mediastinum, retroperitoneum, bone, kidney, colon, liver, spleen and scrotum. Only 3%-10% of neck lesions extend into the mediastinum. In this paper, we report a rare case of cystic hygroma with a huge dimension discussing the use of computed tomography scanning for diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: a tomografia computadorizada (TC) permite a visualização do osso alveolar que recobre os dentes por vestibular e lingual. OBJETIVO: o propósito deste estudo foi expor e discutir as implicações da morfologia do osso alveolar, visualizado por meio da TC, sobre o diagnóstico e plano de tratamento ortodôntico. MÉTODOS: foram descritas as evidências sobre a inter-relação entre características dentofaciais e a morfologia das tábuas ósseas vestibular e lingual, assim como evidências sobre a repercussão da movimentação ortodôntica sobre o nível e espessura dessas estruturas periodontais. RESULTADOS: pacientes adultos podem apresentar deiscências ósseas previamente ao tratamento ortodôntico, principalmente na região dos incisivos inferiores. Os pacientes com padrão de crescimento vertical parecem apresentar menor espessura das tábuas ósseas vestibular e lingual no nível do ápice dos dentes permanentes, comparados a pacientes com padrão de crescimento horizontal. O movimento dentário vestibulolingual descentraliza os dentes do rebordo alveolar e ocasiona deiscências ósseas. CONCLUSÃO: a morfologia do rebordo alveolar constitui um fator limitante para a movimentação dentária e deve ser considerada, de forma individual, na realização do plano de tratamento ortodôntico.