113 resultados para Breathing apparatus.
Resumo:
One of the electrical impedance tomography objectives is to estimate the electrical resistivity distribution in a domain based only on electrical potential measurements at its boundary generated by an imposed electrical current distribution into the boundary. One of the methods used in dynamic estimation is the Kalman filter. In biomedical applications, the random walk model is frequently used as evolution model and, under this conditions, poor tracking ability of the extended Kalman filter (EKF) is achieved. An analytically developed evolution model is not feasible at this moment. The paper investigates the identification of the evolution model in parallel to the EKF and updating the evolution model with certain periodicity. The evolution model transition matrix is identified using the history of the estimated resistivity distribution obtained by a sensitivity matrix based algorithm and a Newton-Raphson algorithm. To numerically identify the linear evolution model, the Ibrahim time-domain method is used. The investigation is performed by numerical simulations of a domain with time-varying resistivity and by experimental data collected from the boundary of a human chest during normal breathing. The obtained dynamic resistivity values lie within the expected values for the tissues of a human chest. The EKF results suggest that the tracking ability is significantly improved with this approach.
Resumo:
This paper presents the results obtained in pin-on-disk test apparatus using glass and alumina as abrasive materials, showing the rates and mechanisms of abrasive wear of 1070 and 52100 steels, and ductile and white cast irons. The test conditions were selected in order to obtain wear rates that correspond to mild and severe abrasion, using different metal hardness-to-abrasive hardness ratios(H/H(A)) and 0.2 or 0.06 mm abrasive grains. The use of bulk Vickers hardness, instead of microhardness, allows a better description of the different abrasion regions. Under severe abrasion, the microcutting mechanism of wear prevailed together with friction coefficients larger than 0.4. On the other hand, when relatively soft abrasives are tested, indentation of abrasive particles followed by its fragmentation, and a creation of a thin deformed layer were the main damage mechanisms, with the friction coefficient lying below 0.4. The abrasive particle size under mild regime is able to change the wear rates in an order of magnitude. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This work discusses the determination of the breathing patterns in time sequence of images obtained from magnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real movement of the lung has never been seen directly, as it is totally dependent on its surrounding muscles and collapses without them. The visualization of the lung in motion is an actual topic of research in medicine. The lung movement is not periodic and it is susceptible to variations in the degree of respiration. Compared to computerized tomography (CT), MR imaging involves longer acquisition times and it is preferable because it does not involve radiation. As coronal and sagittal sequences of images are orthogonal to each other, their intersection corresponds to a segment in the three-dimensional space. The registration is based on the analysis of this intersection segment. A time sequence of this intersection segment can be stacked, defining a two-dimension spatio-temporal (2DST) image. The algorithm proposed in this work can detect asynchronous movements of the internal lung structures and lung surrounding organs. It is assumed that the diaphragmatic movement is the principal movement and all the lung structures move almost synchronously. The synchronization is performed through a pattern named respiratory function. This pattern is obtained by processing a 2DST image. An interval Hough transform algorithm searches for synchronized movements with the respiratory function. A greedy active contour algorithm adjusts small discrepancies originated by asynchronous movements in the respiratory patterns. The output is a set of respiratory patterns. Finally, the composition of coronal and sagittal image pairs that are in the same breathing phase is realized by comparing of respiratory patterns originated from diaphragmatic and upper boundary surfaces. When available, the respiratory patterns associated to lung internal structures are also used. The results of the proposed method are compared with the pixel-by-pixel comparison method. The proposed method increases the number of registered pairs representing composed images and allows an easy check of the breathing phase. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
A high nitrogen austenitic stainless steel (0.9wt% N) and an ordinary 304 austenitic stainless steel were submitted to cavitation-erosion tests in a vibratory apparatus operating at a frequency of 20 kHz. The high nitrogen stainless steel was obtained by high temperature gas nitriding a 1-mm thick strip of an UNS 31803 duplex stainless steel. The 304 austenitic stainless steel was used for comparison purposes. The specimens were characterized by scanning electron microscopy and Electron Back Scatter Diffraction. The surface of the cavitation damaged specimens was analyzed trying to find out the regions where cavitation damage occurred preferentially. The distribution of sites where cavitation inception occurred was extremely heterogeneous, concentrating basically at (i) slip lines inside some grains and (ii) Sigma-3 coincidence site lattice (CSL) boundaries (twin boundaries). Furthermore, it was observed that the CE damage spread faster inside those grains which were more susceptible to damage incubation. The damage heterogeneity was addressed to plasticity anisotropy. Grains in which the crystallographic orientation leads to high resolved shear stress show intense damage at slip lines. Grain boundaries between grains with large differences in resolved shear stress where also intensely damaged. The relationship between crystallite orientation distributions, plasticity anisotropy and CE damage mechanisms are discussed. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Due to its outstanding flexibility, batch distillation is still widely used in many separation processes. In the present work, a comparison between constant and variable reflux operations is studied. Firstly, a mathematical model is developed and then validated through comparison between predicted and experimental results accomplished in a lab-scale apparatus. Therefore, case studies are performed through mathematical simulations. It is noted that the most economical form of batch distillation is at constant overhead product composition, keeping the flow rate of vapor from the top of the column constant. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The double-frequency jitter is one of the main problems in clock distribution networks. In previous works, sonic analytical and numerical aspects of this phenomenon were studied and results were obtained for one-way master-slave (OWMS) architectures. Here, an experimental apparatus is implemented, allowing to measure the power of the double-frequency signal and to confirm the theoretical conjectures. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
This paper presents a rheological investigation of pure gypsum (PG) and a commercial gypsum-lime-filler plaster (CP) using the modified Vicat apparatus and squeeze flow method. The samples were tested at several different intervals after manual or mechanical mixing. The results confirmed squeeze flow to be more sensitive in determining fresh paste behavior than the modified Vicat apparatus. PG set faster when prepared in mechanical mixer than when manually mixed. Conversely, the CP composition presented longer setting when mixed mechanically. The study also included the analysis of two ready-to-use polymer-based products for leveling and rendering (drywall joint compound - DJC; acrylic putty - AP) measured by squeeze flow and compared to the commercial composition. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Two species of Neocypholaelaps Vitzthum are reported from Sri Lanka. One of them, Neocypholaelaps ceylonicus Narita & Moraes, n. sp., is described based on adult females. The other, Neocypholaelaps ampullula (Berlese), originally described from Indonesia, is reported for the first time in Sri Lanka. Complementary morphological information about this species is provided based on the specimens collected in this study. A discussion is presented about the spermathecal apparatus of Neocypholaelaps species.
Resumo:
The aim of this study was to investigate how beaker size, basket assembly, use of disk, and immersion medium impact the disintegration time of dietary supplements. The disintegration times were determined for five tablet and two capsule products. A two-station disintegration tester was used with Apparatus A or Apparatus B as described in the United States Pharmacopeia (USP) chapters, < 701 > and < 2040 >. Two beakers complying with the harmonized specifications were used, one with a volume of 1,000 mL and one with a 1,500-mL volume. The disintegration data were analyzed using ANOVA for the following factors: beaker size, equipment (App A and B) and condition (with/without disk). Two tablet products were not sensitive to any changes in the test conditions or equipment configurations. One product was only partially sensitive to the test conditions. The other products showed impact on the disintegration time for all test conditions. The results revealed that these tablet products might pass or fail current USP disintegration requirements depending on the equipment configuration. Similar results were obtained for the two investigated capsule formulations. One product might fail current USP disintegration requirements if the large beaker was used, but might pass the disintegration requirements when the small beaker was used. Hydroxy propyl methyl cellulose capsules were mostly influenced if sodium instead of a potassium buffer was used as the immersion medium. The results demonstrate that the current harmonized ICH specifications for the disintegration test are insufficient to make the disintegration test into reliable test for dietary supplements.
Resumo:
Sodium diclofenac (SD) release from dosage forms has been studied under different conditions. However, no dissolution method that is discriminatory enough to reflect slight changes in formulation or manufacturing process, and which could be effectively correlated with the biological properties of the dosage form, has been reported. This study sought to develop three different formulae of SD-containing matrix tablets and to determine the effect of agitation speed in its dissolution profiles. F1, F2 and F3 formulations were developed using hypromellose (10, 20 and 30%, respectively for F1, F2 and F3) and other conventional excipients. Dissolution tests were carried out in phosphate buffer pH 6.8 at 37 degrees C using apparatus 11 at 50, 75 or 100 rpm. Dissolution efficiency (DE), T(50) and T(90) were determined and plotted as functions of the variables agitation speed and hypromellose concentration. Regarding DE, F2 showed more sensitivity to variations in agitation speed than F1 and F3. Increasing hypromellose concentration reduced DE values, independent of agitation speed. Analysis of T(50) and T(90) suggests that F1 is less sensitive to variations in agitation speed than F2 and F3. Most discriminatory dissolution conditions were observed at 50 rpm. Results suggest that the comparison of dissolution performance of SD matrix tablets should take into account polymer concentration and agitation conditions. (C) 2009 Published by Elsevier B.V.
Resumo:
The purposes of this work were: (1) to comparatively evaluate the effects of hypromellose viscosity grade and content on ketoprofen release from matrix tablets, using Bio-Dis and the paddle apparatuses, (2) to investigate the influence of the pH of the dissolution medium on drug release. Furthermore, since direct compression had not shown to be appropriate to obtain the matrices under study, it was also an objective (3) to evaluate the impact of granulation on drug release process. Six formulations of ketoprofen matrix tablets were obtained by compression, with or without previous granulation, varying the content and viscosity grade of hypromellose. Dissolution tests were carried out at a fixed pH, in each experiment, with the paddle method (pH 4.5, 6.0, 6.8, or 7.2), while a pH gradient was used in Bio-Dis (pH 1.2 to 7.2). The higher the hypromellose viscosity grade and content were, the lower the amount of ketoprofen released was in both apparatuses, the content effect being more expressive. Drug dissolution enhanced with the increase of the pH of the medium due to its pH-dependent solubility. Granulation caused an increase in drug dissolution and modified the mechanism of the release process.
Resumo:
This paper reports a method for the analysis of secondary metabolites stored in glandular trichomes, employing negative ion `chip-based` nanospray tandem mass spectrometry. The analyses of glandular trichomes from Lychnophora ericoides, a plant endemic to the Brazilian `cerrado` and used in traditional medicine as an anti-inflammatory and analgesic agent, led to the identification of five flavonoids (chrysin, pinocembrin, pinostrobin, pinobanksin and 3-O-acetylpinobanksin) by direct infusion of the extracts of glandular trichomes into the nanospray ionisation source. All the flavonoids have no oxidation at ring B, which resulted in a modification of the fragmentation pathways compared with that of the oxidised 3,4-dihydroflavonoids already described in the literature. The absence of the anti-inflammatory and antioxidant di-C-glucosylflavone vicenin-2, or any other flavonoid glycosides, in the glandular trichomes was also demonstrated. The use of the,`chip-based` nanospray QqTOF apparatus is a new fast and useful tool for the identification of secondary metabolites stored in the glandular trichomes, which can be useful for chemotaxonomic studies based on metabolites from glandular trichomes. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Uranium is a natural radioactive metallic element; its effect on the organism is cumulative, and chronic exposure to this element can induce carcinogenesis. Three cities of the Amazon region-Monte Alegre, Prainha, and Alenquer-in North Brazil, are located in one of the largest uranium mineralization areas of the world. Radon is a radioactive gas, part of uranium decay series and readily diffuses through rock. In Monte Alegre, most of the houses are built of rocks removed from the Earth`s crust in the forest, where the uranium reserves lie. The objective of the present work is to determine the presence or absence of genotoxicity and risk of carcinogenesis induced by natural exposure to uranium and radon in the populations of these three cities. The frequency of micronuclei (MN) and chromosomal aberrations (CA) showed no statistically significant differences between the control population and the three study populations (P > 0.05). MN was also analyzed using the fluorescence in situ hybridization (FISH) technique, with a centromere-specific probe. No clastogenic and/or aneugenic effects were found in the populations. Using FISH analysis, other carcinogenesis biomarkers were analyzed, but neither the presence of the IGH/BCL2 translocation nor an amplification of the MYC gene and 22q21 region was detected. Clastogenicity and DNA damage were also not found in the populations analyzed using the alkaline comet assay. The mitotic index showed no cytotoxicity in the analyzed individuals` lymphocytes. Once we do not have data concerning radiation doses from other sources, such as cosmic rays, potassium, thorium, or anthropogenic sources, it is hard to determine if uranium emissions in this geographic region where our study population lives are too low to cause significant DNA damage. Regardless, genetic analyses suggest that the radiation in our study area is not high enough to induce DNA alterations or to interfere with mitotic apparatus formation. It is also possible that damages caused by radiation doses undergo cellular repair.
Resumo:
This study investigated the effect of a pool of peptides, isolated from venom of Crotalus durissus terrificus (South American rattlesnake) on glucose concentration in C57BL/6 mice fed on a high-fat diet for 6 weeks. The pool of peptides (molecular mass around of 10 kDa) was obtained using a MidJet apparatus with a cartridge of 10 KDa. The peptide pool was injected intraperitoneally in mice in a single dose (0.5 mg/animal) or multiple doses (0.2 mg/dose). After predetermined times (30, 60, 90 and 120 min) post injections, venous blood samples were collected for enzymatic measurement of serum glucose using a commercial glucose kit (glucose oxidase method). High-fat fed mice showed an increase in blood glucose concentration, in comparison with mice fed on the chow diet. Thirty minutes after a single dose of the peptide pool, high-fat fed animals showed a significant decrease (similar to 47%) in glycemia. However, the glucose level increased again at 60 and 120 min. Conversely, after multiple injections of the pool of peptides administered every 30 min, the blood glucose concentration in the high-fat mice was significantly decreased (similar to 37%) and remained at low levels until 120 min. These results suggest that the tested pool of peptides from Crotalus durissus terrificus contained a peptide (or peptides) with a beneficial role on glucose-lowering action of high-fat fed mice.
Resumo:
Scototaxis, the preference for dark environments in detriment of bright ones, is an index of anxiety in zebrafish. In this work, we analyzed avoidance of the white compartment by analysis of the spatiotemporal pattern of exploratory behavior (time spent in the white compartment of the apparatus and shuttle frequency between compartments) and swimming ethogram (thigmotaxis, freezing and burst swimming in the white compartment) in four experiments. In Experiment 1, we demonstrate that spatiotemporal measures of white avoidance and locomotion do not habituate during a single 15-min session. In Experiments 2 and 3, we demonstrate that locomotor activity habituates to repeated exposures to the apparatus, regardless of whether inter-trial interval is 15-min or 24-h; however, no habituation of white avoidance was observed in either experiment. In Experiment 4, we confined animals for three 15-min sessions in the white compartment prior to recording spatiotemporal and ethogram measures in a standard preference test. After these forced exposures, white avoidance and locomotor activity showed no differences in relation to non-confined animals, but burst swimming, thigmotaxis and freezing in the white compartment were all decreased. These results suggest that neither avoidance of the white compartment nor approach to the black compartment account for the behavior of zebrafish in the scototaxis test. (C) 2010 Elsevier B.V. All rights reserved.