54 resultados para Anastomose em Y de Roux


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Surgical treatment has proved to be effective for weight loss, improving the quality of life of obese individuals. However, metabolic and nutritional deficiencies may occur during the late postoperative period. The objective of the present study was to assess the metabolic and nutritional profile of grade III obese individuals for 12 months after Roux-en-Y gastric bypass (RYGBP). Methods Forty-eight patients with mean body mass index (BMI) of 51.9 +/- 7.8 kg/m(2) were submitted to RYGBP. Anthropometric, food intake, and biochemical data were obtained before and for 12 months after surgery. Results There was an average weight and body fat reduction of 35% and 46%, respectively. Calorie intake was reduced, ranging from 773 +/- 206 to 1035 +/- 345 kcal during the study. Protein intake remained below recommended values throughout follow-up, corresponding to 0.5 +/- 0.3 g/kg/current body weight/day during the 12th month. Iron and fiber intake was significantly reduced, remaining below recommended levels throughout the study. Serum cholesterol, low-density lipoprotein cholesterol, and glycemia were reduced. Albumin deficiency was present in 15.6% of subjects at the beginning of the study vs 8.9% at the end, calcium deficiency was present in 3.4% vs 16.7%, and iron deficiency was present in 12.2% vs 14.6%. Conclusions RYGBP was effective for weight loss and for the reduction of obesity rates and risk factors for comorbidities. The diet of these patients, who frequently present inadequate intake of macronutrients and micronutrients, should receive special attention. Patient follow-up and assessment at short intervals are necessary for an early correction of nutritional deficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obesity has become a global epidemic and bariatric surgery is one of the therapeutic tools to deal with it. Postoperative complications can occur, such as staple line dehiscence and anastomotic leaks, leading to increased patient mortality. The diagnosis of these complications is frequently difficult. The objective of the present study was to determine whether peritoneal and systemic cytokines could early detect those complications. All patients who underwent open Roux-en-Y gastric bypass from February 2007 to August 2008 were prospectively evaluated. Blood and peritoneal effluent from the drain were collected for the determination of cytokine levels. We also evaluated the clinical signs and the leukograms of the patients. A total of 107 obese patients were studied. Ninety patients had no complications; 17 had at least one infectious complication which include five cases of staple line dehiscence. Until the third postoperative day, the vital signs and the leukogram did not predict the onset of infectious complications, but the cytokines (interleukin-1 beta and interleukin-6) were early markers of these complications. Cytokines are good predictors of poor postoperative evolution in bariatric surgery since peritoneal cytokines diagnose better these infectious complications even before changes in blood count and before the occurrence of clinical manifestations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>We report a case of T-cell prolymphocytic leukemia (T-PLL) in a 41-year-old male. Classical cytogenetic, spectral karyotyping (SKY) and fluorescence in situ hybridization (FISH) studies of a blood sample obtained at diagnosis revealed the co-existence of t(X;14)(q28;q11), t(Y;14)(q12;q11) and a ring chromosome derivated from i(8)(q10). Immunophenotypic studies revealed involvement of T-cell lineage, with proliferation of CD4(-) CD8(+). The co-existence of two translocations involving both sex chromosomes in a case of T-PLL is rare. Chromosomal instability associated with the disease progression may have allowed the emergence of cell clones with translocations involving the sex chromosomes and the ring chromosome observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The genetic constitution of Afro-derived Brazilian populations is barely studied. To improve that knowledge, we investigated the AluYAP element and five Y-chromosome STRs (DYS19, DYS390, DYS391, DYS392, and DYS393) to estimate ethnic male contribution in the constitution of four Brazilian quilombos remnants: Mocambo, Rio das Ras, Kalunga, and Riacho de Sacutiaba. Results indicated significant differences among communities, corroborating historical information about the Brazilian settlement. We concluded that besides African contribution, there was a great European participation in the constitution of these four populations and that observed haplotype variability could be explained by gene flow to quilombos remnants and mutational events in microsatellites (STRs). Am. J. Hum. Biol. 21:354-356, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bilioduodenal and biliojejunal anastomoses are effective for the treatment of biliary obstruction. The objective of this study was to compare the effects of these anastomoses on hepatobiliary excretion and enterobiliary reflux. Enterobiliary reflux and biliary excretion were evaluated respectively after oral administration of technetium (Tc-99m) in combination with sodium phytate and intravenous infusion of Tc-99m with diisopropyl-iminodiacetic acid. Enterobiliary reflux occurred to an equal degree in the bilioduodenal and biliojejunal groups. Maximum hepatic activity time (T-max) and radiotracer clearance half-time (T-1/2) were similar in both groups. However, when compared with that found for the sham-operated group, T-max, and T-1/2 were higher in the biliojejunal group (P = 0.02 and P = 0.01, respectively). Histopathological analysis showed marked reduction in ductal proliferation in both groups. These data undermine the theoretical advantages attributed to biliojejunal anastomosis and further the understanding of the pathophysiology of cholangitis that occurs even with patent anastomosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study compared the reliability and fracture patterns of zirconia cores veneered with pressable porcelain submitted to either axial or off-axis sliding contact fatigue. Methods: Forty-two Y-TZP plates (12 mm x 12 mm x 0.5 mm) veneered with pressable porcelain (12 mm x 12 mm x 1.2 mm) and adhesively luted to water aged composite resin blocks (12 mm x 12 mm x 4 mm) were stored in water at least 7 days prior to testing. Profiles for step-stress fatigue (ratio 3:2:1) were determined from single load to fracture tests (n = 3). Fatigue loading was delivered on specimen either on axial (n = 18) or off-axis 30 degrees angulation (n = 18) to simulate posterior tooth cusp inclination creating a 0.7 mm slide. Single load and fatigue tests utilized a 6.25 mm diameter WC indenter. Specimens were inspected by means of polarized-light microscope and SEM. Use level probability Weibull curves were plotted with 2-sided 90% confidence bounds (CB) and reliability for missions of 50,000 cycles at 200 N (90% CB) were calculated. Results: The calculated Weibull Beta was 3.34 and 2.47 for axial and off-axis groups, respectively, indicating that fatigue accelerated failure in both loading modes. The reliability data for a mission of 50,000 cycles at 200 N load with 90% CB indicates no difference between loading groups. Deep penetrating cone cracks reaching the core-veneer interface were observed in both groups. Partial cones due to the sliding component were observed along with the cone cracking for the off-axis group. No Y-TZP core fractures were observed. Conclusions: Reliability was not significantly different between axial and off-axis mouth-motion fatigued pressed over Y-TZP cores, but incorporation of sliding resulted in more aggressive damage on the veneer. (C) 2009 Elsevier Ltd. All rights reserved.