52 resultados para ACCUMULATION-MODE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The afferent nerves of the cornea and conjunctiva, efferent nerves of the lacrimal gland, and the lacrimal gland are a functional unit that works cooperatively to produce the aqueous component of tears. A decrease in the lacrimal gland secretory function can lead to dry eye disease. Because aging is a risk factor for dry eye disease, study of the changes in the function of the lacrimal gland functional unit with age is important for developing treatments to prevent dry eye disease. No one mechanism is known to induce the changes that occur with aging, although multiple different mechanisms have been associated with aging. These fall into two theoretical categories: programmed theories of aging (immunological, genetic, apoptotic, and neuroendocrine) and error theories of aging (protein alteration, somatic mutation, etc). Lacrimal glands undergo structural and functional alteration with increasing age. In mouse models of aging, it has been shown that neural stimulation of protein secretion is an early target of aging, accompanied by an increase in mast cells and lipofuscin accumulation. Hyperglycemia and increased lymphocytic infiltration can contribute to this loss of function at older ages. These findings suggest that an increase in oxidative stress may play a role in the loss of lacrimal gland function with age. For the afferent and efferent neural components of the lacrimal gland functional unit, immune or inflammatory mediated decrease in nerve function could contribute to loss of lacrimal gland secretion with age. More research in this area is critically needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four 1.5-year-old, male, Murrah buffalos were maintained during eight months without direct solar exposure during a study of copper toxicosis. Four days after solar exposure, all buffalos presented clinical manifestations consistent with acute photosensitization, including anorexia, apathy, loss of body weight, and generalized cutaneous lesions. Gross lesions were characterized by severe erythema, localized edema, fissures, tissue necrosis, gangrene and crust formation with h serous exudation. Liver copper concentration was evaluated, and cutaneous biopsies were taken when clinical signs were evident. The liver copper concentration before solar exposure was increased in all animals. Histopathologic examination of the skin revealed hepatogenous photosensitization characterized by parakeratotic hyperkeratosis, acantholysis, degeneration of squamous epithelial cells, epidermal necrosis with atrophy of sweat glands, and multifocal superficial and deep dermal edema. These findings suggest that asymptomatic accumulation of copper within the liver might have induced hepatic insufficiency thereby resulting in secondary photosensitization when these buffalos were exposed to sunlight. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this study was to evaluate the clinical and hematological alterations, and the hepatic concentration of Cu in buffaloes with chronic copper poisoning (CCP). Ten buffalo yearling steers were randomly distributed into two groups: one copper supplemented (BUFCu; n = 6) and another control group (BUF; n = 4). The group BUFCu received, by ruminal fistula, 2 mg Cu/kgBW (as CuSO4.5H2O) daily during one week; after which 2 mg Cu/kgBW was added during each additional week, until the end or the experiment (105(th) day). Three liver biopsies were realized during the experiment (day zero, 45(th), and 105(th) day) to determine the degree of copper accumulation. Alterations in body weight, clinical examination, and hematological values were monitored every 15 days. Two buffaloes supplemented with copper demonstrated clinical manifestations consistent with CCP, and died. Two distinct clinical manifestations were observed, one classical (n = 1) and another atypical (n = 1), characterized by remarkable high levels of liver copper, progressive hyporexia followed by anorexia, dehydration, severe apathy, decreased rumen movements, oliguria, and death. Some animals were resistant to CCP although high copper intake. In buffalos with clinical picture similar to the one described as atypical, CCP should be considered as a possible diagnostic even without presence of macroscopic hemoglobinuria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the qualitative and quantitative differences on dental plaque formation on two different roughness titanium implant surfaces, i.e. machined and titanium plasma sprayed, as well as the amount of plaque removal by regular toothbrushing after 72-hour plaque accumulation. Methods: Eight systemically healthy subjects were recruited from the patient pool of a private dental practice. All patients underwent oral hygiene instruction and full mouth prophylaxis. Subsequently, maxillary casts from all patients were obtained and removable 0.7 mm-thick acetate stents without occlusal contact points were fabricated to support four titanium specimens of 4x2x2 mm divided into two groups (machined and plasma sprayed). Subjects were instructed to wear the stents for 72 hours, full time, removing them only during regular oral hygiene. Subsequently, the appliances were immediately repositioned and then the test side was brushed for 20 seconds. At the end of the 72-hour period, the stents were removed and prepared for microbiological analysis. Results: Both machined and plasma sprayed brushed surfaces presented statistically significant fewer bacteria than non-brushed surfaces. Similarly, regarding surface roughness, machined surfaces presented a total number of bacteria significantly smaller than those presented by plasma sprayed surfaces (P< 0.05). Statistically, the non-brushed machined turned surfaces presented a greater amount of Streptoccocus sp. when compared to the brushed machined surfaces. It was concluded that rough surfaces accumulated more dental plaque than polished surfaces. Both brushed surfaces presented less plaque accumulation, however, implant brushing was more effective on machined surfaces. (Am J Dent 2008;21:318-322).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Provision of an inert gas atmosphere with high-purity argon gas is recommended for preventing titanium castings from contamination although the effects of the level of argon purity on the mechanical properties and the clinical performance of Ti castings have not yet been investigated. The purpose of this study was to evaluate the effect of argon purity on the mechanical properties and microstructure of commercially pure (cp) Ti and Ti-6Al-4V alloys. The castings were made using either high-purity and/or industrial argon gas. The ultimate tensile strength (UTS), proportional limit (PL), elongation (EL) and microhardness (VHN) at different depths were evaluated. The microstructure of the alloys was also revealed and the fracture mode was analyzed by scanning electron microscopy. The data from the mechanical tests and hardness were subjected to a two-and three-way ANOVA and Tukey`s test (alpha = 0.05). The mean values of mechanical properties were not affected by the argon gas purity. Higher UTS, PL and VHN, and lower EL were observed for Ti-6Al-4V. The microhardness was not influenced by the argon gas purity. The industrial argon gas can be used to cast cp Ti and Ti-6Al-4V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of the present in situ study was to evaluate the influence of dental plaque on human enamel erosion. Materials and Methods: Thirteen volunteers wore acrylic palatal devices with four enamel specimens that were prepared from freshly extracted impacted human third permanent molars (4 x 4 mm), randomly selected and distributed into two vertical rows, corresponding to the following groups: GI, erosion of dental plaque-free samples, and GII, erosion of dental plaque-covered samples. For the formation of dental plaque, the specimens were placed 1 mm below the level of the appliance and covered with a plastic mesh to allow the accumulation of dental plaque. The palatal device was continuously worn by the volunteers for 14 consecutive days and then immersed in a soft drink (Coca-Cola (R), 150 ml) for 5 min, three times a day. Half of the surfaces of specimens were coated with nail varnish for profilometry tests. The study variables included the depth of enamel surface wear (profilometer, vertical ranges in pm) and the percentage of superficial microhardness change (%SMHC). Data were analysed using the t test (P < 0.05). Results: The %SMHC and depth of enamel surface wear were significantly higher for GI (-87.82% +/- 3.66 and 4.70 mu m +/- 1.65) than for GII (-13.79% +/- 4.22 and 0.14 mu m +/- 0.03). Conclusions: It was concluded that the dental plaque formed in situ was able to protect the enamel surface against erosion by a cola soft drink, thus reducing the depth of enamel surface wear and the %SMHC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study compared the reliability and fracture patterns of zirconia cores veneered with pressable porcelain submitted to either axial or off-axis sliding contact fatigue. Methods: Forty-two Y-TZP plates (12 mm x 12 mm x 0.5 mm) veneered with pressable porcelain (12 mm x 12 mm x 1.2 mm) and adhesively luted to water aged composite resin blocks (12 mm x 12 mm x 4 mm) were stored in water at least 7 days prior to testing. Profiles for step-stress fatigue (ratio 3:2:1) were determined from single load to fracture tests (n = 3). Fatigue loading was delivered on specimen either on axial (n = 18) or off-axis 30 degrees angulation (n = 18) to simulate posterior tooth cusp inclination creating a 0.7 mm slide. Single load and fatigue tests utilized a 6.25 mm diameter WC indenter. Specimens were inspected by means of polarized-light microscope and SEM. Use level probability Weibull curves were plotted with 2-sided 90% confidence bounds (CB) and reliability for missions of 50,000 cycles at 200 N (90% CB) were calculated. Results: The calculated Weibull Beta was 3.34 and 2.47 for axial and off-axis groups, respectively, indicating that fatigue accelerated failure in both loading modes. The reliability data for a mission of 50,000 cycles at 200 N load with 90% CB indicates no difference between loading groups. Deep penetrating cone cracks reaching the core-veneer interface were observed in both groups. Partial cones due to the sliding component were observed along with the cone cracking for the off-axis group. No Y-TZP core fractures were observed. Conclusions: Reliability was not significantly different between axial and off-axis mouth-motion fatigued pressed over Y-TZP cores, but incorporation of sliding resulted in more aggressive damage on the veneer. (C) 2009 Elsevier Ltd. All rights reserved.