208 resultados para short Nylon-6 fiber


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of storage condition and duration on the resistance to fracture of different fiber post systems (and to morphologically assess the post structure before and after storage. Methods: Three types of fiber posts (DT Light Post, GC Post, FRC Postect Plus) were divided in different groups (n=12) according to the storage condition (dry at 37 degrees C; saline water at 37 degrees C; mineral oil at 37 degrees C and storage inside the roots of extracted human teeth immersed in saline water at 37 degrees C and duration (6, 12 months). A universal testing machine loading at a 90 degrees angle was employed for the three-point bending test. The test was carried out until fracture of the post. A 3-way ANOVA and Tukey`s test (alpha= 0.05) were used to compare the effect of the experimental factors on the fracture strength. Two posts of each group were observed before and after the storage using a scanning electron microscope. Results: Storage condition and post type had a significant effect on post fracture strength (P< 0.05). The interaction between these factors was significant (P< 0.05). Water storage significantly decreased the fracture strength, regardless of the post type and the storage duration. Storage inside roots, in oil, and at dry conditions did not significantly affect post fracture strength. SEM micrographs revealed voids between fibers and resin matrix for posts stored in water. Posts stored under the other conditions showed a compact matrix without porosities. (Am J Dent 2009;22:366-370).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of surface treatments on microtensile bond strength of luting resin cements to fiber posts. Materials and Methods: Forty-two quartz fiber posts (Light Post, RTD) were divided into 7 groups (n = 6) according to the surface treatment. I and 11: experimental patented industrial treatment consisting of zirconium oxide coating and silanization (RTD); III: industrial treatment followed by adhesive application (XPBond, Dentsply Caulk); IV: adhesive (XPBond); V: adhesive (Prime&Bond NT, Dentsply Caulk); VI: silane (Calibra Silane, Dentsply Caulk); VII: no treatment. Adhesives were used in the self-curing mode. Two cements (Sealbond, RTD - group 1, and Calibra, Dentsply Caulk - groups 11 to VII) were applied on the posts to produce cylindrical specimens. Post/cement interfaces were evaluated under SEM. The surface of the industrially coated posts was examined using energy dispersive analysis by x-ray. Cylinders were cut to obtain microtensile sticks that were loaded in tension at a crosshead speed of 0.5 mm/min until failure. Statistical analysis was performed using Kruskal-Wallis analysis of variance followed by Dunn`s multiple range test for post-hoc comparisons (p < 0.05). Weibull analysis was also performed. Results: The post/cement bond strength was significantly higher on fiber posts treated industrially (I: 23.14 +/- 8.05 MPa; II: 21.56 +/- 7.07 MPa; III: 22.37 +/- 7.00 MPa) or treated with XPBond adhesive (IV: 21.03 +/- 5.34 MPa) when compared to Prime&Bond NT application (V: 14.05 +/- 5.06 MPa), silanization (VI: 6.31 +/- 4.60 MPa) or no treatment (VII: 4.62 +/- 4.31) of conventional fiber posts (p < 0.001). Conclusion: The experimental industrial surface treatment and the adhesive application enhanced fiber post to resin cement interfacial strength. Industrial pretreatment may simplify the clinical luting procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-steroidal anti-inflammatory drugs (NSAIDs) have been used for pain relief in orthodontics, but clinical studies reported that they may reduce tooth movement (TM). By other side, TM seems to activate brain structures related to nociception, but the effects of NSAIDs in this activation have not been studied yet. We analyzed the effect of short-term treatment with acetaminophen or celecoxib in the separation of rat upper incisors, as well as in neuronal activation of the spinal trigeminal nucleus, following tooth movement. Thirty rats (400-420 g) were pretreated through oral gavage (1 ml/dose)with acetaminophen (200 mg/kg), celecoxib (50 mg/kg) or vehicle (carboxymethylcellulose 0.4%). After 30 min, they received an activated (30 g) orthodontic appliance for TM. In controls, this appliance was immediately removed after its introduction. Rats received ground food, and every 12 h, one of the drugs or vehicle. After 48 h, they were anesthetized, maxilla was radiographed, and were perfused with 4% paraformaldehyde. Brains were further processed for Fos immunohistochemistry. TM induced incisor distalization (p < 0.05) and neuronal activation of the spinal trigeminal nucleus. Treatment with both drugs did not affect tooth movement, but reduced c-fos expression in the caudalis subnucleus. No changes in c-fos expression were seen in the oralis and interpolaris subnuclei. We conclude that neither celecoxib nor acetaminophen seems to affect tooth movement, when used for 2 days, but both drugs are able to reduce the activation of brain structures related to nociception. Short-term treatment with celecoxib, thus, may be a therapeutic alternative to acetaminophen when the latter is contra indicated. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. Dental fractures can occur in endodontically treated teeth restored with posts. Purpose. The purpose of this study was to evaluate the in vitro fracture resistance of roots with glass-fiber and metal posts of different lengths. Material and methods. Sixty endodontically treated maxillary canines were embedded in acrylic resin, except for 4 mm of the cervical area, after removing the clinical crowns. The post spaces were opened with a cylindrical bur at low speed attached to a surveyor, resulting in preparations with lengths of 6 mm (group 6 mm), 8 mm (group 8 mm), or 10 mm (group 10 mm). Each group was divided into 2 subgroups according to the post material: cast post and core or glass-fiber post (n=30). The posts were luted with dual-polymerizing resin cement (Panavia F). Cast posts and cores of Co-Cr (Resilient Plus) crowns were made and cemented with zinc phosphate. Specimens were subjected to increasing compressive load (N) until fracture. Data were analyzed with 2-way ANOVA and the Tukey-Kramer test (alpha=.05). Results. The ANOVA analysis indicated significant differences (P<.05) among the groups, and the Tukey test revealed no significant difference among the metal posts of 6-mm length (26.5 N +/- 13.4), 8-mm length (25.2 N +/- 13.9), and 10-mm length (17.1 N +/- 5.2). Also, in the glass-fiber post group, there was no significant difference when posts of 8-mm length (13.4 N +/- 11.0) were compared with the 6-mm (6.9 N +/- 4.6) and 10-mm (31.7 N +/- 13.1) groups. The 10-mm-long post displayed superior fracture resistance, and the 6-mm-long post showed significantly lower mean values (P<.001). Conclusions. Within the limitations of this study, it was concluded that the glass-fiber post represents a viable alternative to the cast metal post, increasing the resistance to fracture of endodontically treated canines. (J Prosthet Dent 2009;101:183-188)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to verify the influence of endodontic sealers on the bond strength of an adhesive system and a resin cement used for carbon posts cementation. Methods: Thirty extracted human premolars were instrumented and randomly divided into three groups according to the tested sealer: EndoFill, Sealapex, or EndoREZ. Specimens were stored at 37 degrees C. After 48 h, half of specimens were prepared to receive the post and the others after 7 days. The posts were cemented with Adper Single Bond/Rely X ARC and stored in distilled water at 37 degrees C for 7 days. After this period, the specimens were sectioned in three slices (coronal, middle, and apical). The push-out test was performed in a universal machine and the debonded area was examined in a stereomicroscope. Results: Data were submitted ANOVA and Tukey test (alpha = 0.05). The EndoFill showed lower bond strength than other sealers (p < 0.01). The EndoREZ sealer was statistically greater than other groups for coronal and middle portions and similar for apical portion (P > 0.05). Coronal and middle portions showed the best results for all groups, mainly when the canal preparation was performed after 48 h (p < 0.01). Mixed failure occurs with more frequency (55.6%) followed by failure in adhesive-dentin interface (34.4%) and adhesive-post interface (10.0%). Conclusion: The use of EndoREZ sealer promoted higher bond strength in root coronal and middle portions when carbon post was fixed with a resin cement. (C) 2007 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the bond strength of glass fiber posts to intraradicular dentin when cemented with self-etching and self-adhesive resin cements. Materials and Methods: Forty-eight single-rooted human teeth were decoronated, endodontically treated, post-space prepared and divided into 8 groups (n = 6). The glass fiber posts used were: Exacto (EA) (Angelus) and everStick (ES) (StichTeck), which were cemented with two self-adhesive resin cements: BisCem (BIS) (Bisco) and Rely-X Unicem (UNI) (3M/ESPE), and two self-etching resin cements: Esthetic Cementing System NAC100 (NAC) (Kuraray) and Panavia-F (PAN) (Kuraray). Specimens were thermocycled between 5 degrees C and 55 degrees C for 1000 cycles and stored in water at 37 degrees C for 1 month. Four 1-mm-thick (in cross section) rods were obtained from the cervical region of the roots. Specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) at a crosshead speed of 0.5 mm/min. Microtensile bond strength (mu TBS) data were analyzed with two-way ANOVA and Tukey`s tests. Results: Means (and SD) of mu TBS (MPa) were: EA/PAN: 10.3 (4.1), EA/NAC: 14 (5.1) EA/BIS: 16.4 (4.8), EA/UNI: 19.8 (5.1), ES/PAN: 25.9 (6.1), ES/NAC: 29.1 (7), ES/BIS: 28.9 (6), ES/UNI: 30.5 (6.6). ANOVA indicated significant differences among the groups (p < 0.001). Mean mu TBS values obtained with ES post were significantly higher than those obtained with EA (p < 0.001). For EA, Tukey`s test indicated that higher mu TBS means were obtained with the self-adhesive resin cements (BIS and UNI), which were statistically significantly different (p < 0.05) from values obtained with the self-etching resin cements (PAN and NAC). Different cements had no significant effects on the bond strength values of ES post (p > 0.05). mu TBS values obtained with ES post were significantly higher than those obtained with EA post irrespective of the resin cement used. Conclusion: everStick posts resulted in the highest mean mu TBS values with all cements. Self-adhesive cements performed well in terms of bond strength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ecological studies of movements in animals require extensive knowledge of direction, distance and frequency of movements. The purpose of this study was to describe the daily and seasonal movements in a population of the South American rattlesnake, Crotalus durissus. The study population inhabits a cerrado area in southeastern Brazil. Snakes were tracked with externally attached radio-transmitters and thread bobbins. Larger animals tended to make more extensive daily movements, moving further from the initial site of capture. There were no differences in average daily movements between sexes. Site fidelity was higher in the dry season for both sexes. Both sexes moved distances twice as long as those calculated by drawing a straight line between consecutive points. The movement pattern of C. durissus seemed to be similar to that observed in other tropical pit vipers, such as species of the genus Bothrops.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The characterisation of sequences at chromosome ends of Rhynchosciara americana was continued with the screening of a genomic library using as a probe a short repeat identified in a previous report (M-22, 22 bp) which was found to be specific for noncentromeric termini of this species. Simple repeats, complex tandem and apparently dispersed repeats were present in the genomic clones analysed. Repetitive sequences do not define individual chromosome tips as they were found in all noncentromeric ends. A novel and unusually short tandem repeat type for dipteran chromosome ends (named M-16) composed of 16 nucleotides and frequently associated with M-22 arrays was characterised in this work. Islands of M-16 and M-22 tandem repeats were found in all the genomic clones analysed. Individual probes representative of each repetitive element hybridised not only to all noncentromeric ends of R. americana chromosomes but also to inter-telomeric bridges. This contrasted with the other repeat types which displayed sub-telomeric localisation as seen by double detection of hybridised probe and telomeric reverse transcriptase. Some stretches composed of M-16 and M-22 tandem repeats localised in different regions of the analysed genomic clones were either identical or showed sequence similarity that was unexpectedly higher than the mean sequence similarity observed among repeats within each of their tandem arrays. The occurrence of segmental duplications, as deduced by sequence analyses involving the two repeats that appeared to reach chromosome ends, might indicate the involvement of this type of duplication process in the chromosome end maintenance in this species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Behavioral consequences of convulsive episodes are well documented, but less attention was paid to changes that occur in response to subconvulsant doses of drugs. We investigated short- and long-term effects of a single systemic injection of a subconvulsant dose of pilocarpine on the behavior of rats as evaluated in the elevated plus maze. Pilocarpine induced an anxiogenic-like profile 24 h later, and this effect persisted for up to 3 months (% of time spent on open arms at 24 h, control = 35.47 +/- 3.23; pilocarpine 150 = 8.2 +/- 2.6; 3 months, control = 31.9 +/- 5.5; pilocarpine 150 = 9.3 +/- 4.9). Temporary inactivation of fimbria-fornix with lidocaine 4% promoted an anxiolytic-like effect per se, suggesting a tonic control of this pathway on the modulation of anxiety-related behaviors. Lidocaine also reduced the anxiogenic-like profile of animals tested 1 month after pilocarpine treatment (% of time spent on open arms, saline + phosphate-buffered saline (PBS) = 31.7 + 3.7; saline + lidocaine = 54.4 + 4.7; pilocarpine + PBS = 10.3 + 4.1; pilocarpine + lidocaine = 40.1 + 9.1). To determine whether the anxiogenic-like effect was mediated by septal region or by direct hippocampal projections to the diencephalon, the neural transmission of post-commissural fornix was blocked, and a similar reduction in the anxiogenic-like effect of pilocarpine was observed. Our findings suggest that a single systemic injection of pilocarpine may induce long-lasting anxiogenic-like behavior in rats, an effect that appears to be mediated, in part, through a direct path from hippocampus to medial hypothalamic sites involved in fear responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to verify the effects of short periods of exercise of different intensity on lymphocyte function and cytokines. Thirty Wistar rats, 2 months old, were used. They were divided into five groups of six rats: a sedentary control group; a group exercised for 5 minutes at low intensity (5 L): a group exercised for 15 minutes at low intensity (15 L); and groups exercised at moderate intensity (additional load of 5% of body weight) for 5 minutes (5 M) or for 15 minutes (15 M). The parameters measured were: total leukocytes, neutrophils, lymphocytes, monocytes, lymphocytes from lymph nodes, serum cytokines (IL-2, IL-6 and TNF-alpha), lymphocyte mitochondrial transmembrane potential, viability and DNA fragmentation. ANOVA two way followed by Tukey`s post hoc test (p <= 0.05) was used. The exercised groups exhibited a significant increase in total leukocytes, tissue and circulating lymphocytes in comparison with the control group. There was a significant decrease in lymphocyte viability and decrease in DNA fragmentation for the 15 M group when compared with the control. There was a decrease in the level TNF-alpha in the 5 M and 15 M groups. Short-term, low- and moderate-intensity exercise may be considered for sedentary individuals beginning to exercise, since no deleterious alterations were observed in lymphocyte function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It currently is unknown whether creatine supplementation is safe for people with or at risk of kidney disease. We report on the short-term effects of creatine supplementation on kidney function in a young man with a single kidney and mildly decreased glomerular filtration rate (GFR). A 20-year-old man who had undergone unilateral nephrectomy and presented with mildly decreased GFR without kidney damage underwent a trial with 35 days of creatine supplementation (20 g/d for 5 days followed by 5 g/d for the next 30 days) and had his kidney function monitored. After the intervention, (51)Cr-EDTA clearance (pre, 81.6 mL/min/1.73 m(2); post, 82.0 mL/min/1.73 m(2)), proteinuria (protein excretion: pre, 130 mg/d; post, 120 mg/d), and electrolyte levels were unchanged. Albuminuria, serum urea level, and estimated creatinine clearance were decreased (pre, 4.6 mg/d; post, 2.9 mg/d; pre, 37 mg/d; post, 28 mg/dL; and pre, 88 mL/min/1.73 m(2); post, 71 mL/min/1.73 m(2), respectively), whereas serum creatinine level was slightly increased (pre, 1.03 mg/dL; post, 1.27 mg/dL), falsely suggesting kidney function impairment. This prospective report suggests that short-term creatine supplementation may not affect kidney function in an individual with a single kidney, mild decreased GFR, and ingesting a high-protein diet (ie, 2.8 g/kg/d). This finding has great relevance considering that creatine-induced kidney disease has been a growing concern, even for healthy people. Am J Kidney Dis 55: e7-e9. (C) 2010 by the National Kidney Foundation, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several studies have shown the antidiabetic properties of sodium tungstate. In this study, we evaluated some biochemical parameters of the parotid salivary gland of streptozotocin-induced diabetic rats treated with sodium tungstate solution (2 mg/ml). The studied groups were: untreated control (UC), treated control (TC), untreated diabetic (UD), and treated diabetic (TD). After 2 and 6 weeks of treatment, parotid gland was removed and total protein and sialic acid (free and total) concentration and amylase and peroxidase activities were determined. Data were compared by variance analysis and Tukey test (p < 0.05). The sodium tungstate treatment modestly decreased the glycemia of streptozotocin-induced diabetic rats. At week 2 of the study, parotid gland of diabetic rats presented a reduction of total protein concentration (55%) and an increase of amylase (120%) and peroxidase (160%) activities, free (150%) and total (170%) sialic acid concentration. No alteration in the evaluated parameters at week 6 of the study was observed. Sodium tungstate presented no significant effect in parotid gland. Our results suggest that diabetes causes initial modification in biochemical composition of parotid. However, this gland showed a recovery capacity after 6 week of the experimental time. Sodium tungstate has no effect in peripheral tissues, such as salivary glands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two clinical cases in which Portland cement (PC) was applied as a medicament after pulpotomy of mandibular primary molars in children are presented. Pulpotomy using PC was carried out in two mandibular first molars and one mandibular second molar, which were further followed-up. At the 3, 6 and 12-month follow-up appointments, clinical and radiographic examinations of the pulpotomized teeth and their periradicular area revealed that the treatments were successful in maintaining the teeth asymptomatic and preserving pulpal vitality. Additionally, the formation of a dentin bridge immediately below the PC could be observed in the three molars treated. PC may be considered as an effective alternative for primary molar pulpotomies, at least in a short-term period. Randomized clinical trials with human teeth are required in order to determine the suitability of PC before unlimited clinical use can be recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effects of the cement type and the water storage time on the push-out bond strength of a glass fiber post. Glass fiber posts (Fibrekor, Jeneric Pentron) were luted to post spaces using a self-cured resin cement (C&B Cement [CB]), a glass ionomer cement (Ketac Cem [KC]) or a resin-modified glass ionomer cement (GC FujiCEM [FC]) according to the manufacturers’ instructions. For each luting agent, the specimens were exposed to one of the following water storage times (n=5): 1 day (T1), 7 days (T7), 90 days (T90) and 180 days (T180). Push-out tests were performed after the storage times. Control specimens were not exposed to water storage, but subjected to the push-out test 10 min after post cementation. Data (in MPa) were analyzed by Kruskal-Wallis and Dunn`s test (α=0.05). Cement type and water storage time had a significant effect (p<0.05) on the push-out bond strength. CB showed significantly higher values of retention (p<0.05) than KC and FC, irrespective of the water storage time. Water storage increased significantly the push-out bond strength in T7 and T90, regardless of the cement type (p<0.05). The results showed that fiber posts luted to post spaces with the self-cured resin cement exhibited the best bonding performance throughout the 180-day water storage period. All cements exhibited a tendency to increase the bond strength after 7 and 90 days of water storage, decreasing thereafter.