93 resultados para reproducibility
Resumo:
The Community Climate Model (CCM3) from the National Center for Atmospheric Research (NCAR) is used to investigate the effect of the South Atlantic sea surface temperature (SST) anomalies on interannual to decadal variability of South American precipitation. Two ensembles composed of multidecadal simulations forced with monthly SST data from the Hadley Centre for the period 1949 to 2001 are analysed. A statistical treatment based on signal-to-noise ratio and Empirical Orthogonal Functions (EOF) is applied to the ensembles in order to reduce the internal variability among the integrations. The ensemble treatment shows a spatial and temporal dependence of reproducibility. High degree of reproducibility is found in the tropics while the extratropics is apparently less reproducible. Austral autumn (MAM) and spring (SON) precipitation appears to be more reproducible over the South America-South Atlantic region than the summer (DJF) and winter (JJA) rainfall. While the Inter-tropical Convergence Zone (ITCZ) region is dominated by external variance, the South Atlantic Convergence Zone (SACZ) over South America is predominantly determined by internal variance, which makes it a difficult phenomenon to predict. Alternatively, the SACZ over western South Atlantic appears to be more sensitive to the subtropical SST anomalies than over the continent. An attempt is made to separate the atmospheric response forced by the South Atlantic SST anomalies from that associated with the El Nino - Southern Oscillation (ENSO). Results show that both the South Atlantic and Pacific SSTs modulate the intensity and position of the SACZ during DJF. Particularly, the subtropical South Atlantic SSTs are more important than ENSO in determining the position of the SACZ over the southeast Brazilian coast during DJF. On the other hand, the ENSO signal seems to influence the intensity of the SACZ not only in DJF but especially its oceanic branch during MAM. Both local and remote influences, however, are confounded by the large internal variance in the region. During MAM and JJA, the South Atlantic SST anomalies affect the magnitude and the meridional displacement of the ITCZ. In JJA, the ENSO has relatively little influence on the interannual variability of the simulated rainfall. During SON, however, the ENSO seems to counteract the effect of the subtropical South Atlantic SST variations on convection over South America.
Resumo:
A new approach for the integration of dual contactless conductivity and amperometric detection with an electrophoresis microchip system is presented. The PDMS layer with the embedded channels was reversibly sealed to a thin glass substrate (400 mu m), on top of which a palladium electrode had been previously fabricated enabling end-channel amperometric detection. The thin glass substrate served also as a physical wall between the separation channel and the sensing copper electrodes for contactless conductivity detection. The latter were not integrated in the microfluidic device, but fabricated on an independent plastic substrate allowing a simpler and more cost-effective fabrication of the chip. PDMS/glass chips with merely contactless conductivity detection were first characterized in terms of sensitivity, efficiency and reproducibility. The separation efficiency of this system was found to be similar or slightly superior to other systems reported in the literature. The simultaneous determination of ionic and electroactive species was illustrated by the separation of peroxynitrite degradation products, i.e. NO(3)(-) (non-electroactive) and NO(2)(-) (electroactive), using hybrid PDMS/glass chips with dual contactless conductivity and amperometric detection. While both ions were detected by contactless conductivity detection with good efficiency, NO(2)(-) was also simultaneously detected amperometrically with a significant enhancement in sensitivity compared to contactless conductivity detection.
Resumo:
The nature of the molecular structure of plastics makes the properties of such materials markedly temperature dependent. In addition, the continuous increase in the utilization of polymeric materials in many specific applications has demanded knowledge of their physical properties, both during their processing as raw material, as well as over the working temperature range of the final polymer product. Thermal conductivity, thermal diffusivity and specific heat, namely the thermal properties, are the three most important physical properties of a material that are needed for heat transfer calculations. Recently, among several different methods for the determination of the thermal diffusivity and thermal conductivity, transient techniques have become the preferable way for measuring thermal properties of materials. In this work, a very simple and low cost variation of the well known Angstrom method is employed in the experimental determination of the thermal diffusivity of some selected polymers. Cylindrical shaped samples 3 cm diameter and 7 cm high were prepared by cutting from long cylindrical commercial bars. The reproducibility is very good, and the results obtained were checked against results obtained by the hot wire technique, laser flash technique, and when possible, they were also compared with data found in the literature. Thermal conductivity may be then derived from the thermal diffusivity with the knowledge of the bulk density and the specific heat, easily obtained by differential scanning calorimetry. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The performance optimisation of overhead conductors depends on the systematic investigation of the fretting fatigue mechanisms in the conductor/clamping system. As a consequence, a fretting fatigue rig was designed and a limited range of fatigue tests was carried out at the middle high cycle fatigue regime in order to access an exploratory S-N curve for a Grosbeak conductor, which was mounted on a mono-articulated aluminium clamping system. Subsequent to these preliminary fatigue tests, the components of the conductor/clamping system, such as ACSR conductor, upper and lower clamps, bolt and nuts, were subjected to a failure analysis procedure in order to investigate the metallurgical free variables interfering on the fatigue test results, aiming at the optimisation of the testing reproducibility. The results indicated that the rupture of the planar fracture surfaces observed in the external At strands of the conductor tested under lower bending amplitude (0.9 mm) occurred by fatigue cracking (I mm deep), followed by shear overload. The V-type fracture surfaces observed in some At strands of the conductor tested under higher bending amplitude (1.3 mm) were also produced by fatigue cracking (approximately 400 mu m deep), followed by shear overload. Shear overload fracture (45 degrees fracture surface) was also observed on the remaining At wires of the conductor tested under higher bending amplitude (1.3 mm). Additionally, the upper and lower Al-cast clamps presented microstructure-sensitive cracking, which was folowed by particle detachment and formation of abrasive debris on the clamp/conductor tribo-interface, promoting even further the fretting mechanism. The detrimental formation of abrasive debris might be inhibited by the selection of a more suitable class of as-cast At alloy for the production of clamps. Finally, the bolt/nut system showed intense degradation of the carbon steel nut (fabricated in ferritic-pearlitic carbon steel, featuring machined threads with 190 HV), with intense plastic deformation and loss of material. Proper selection of both the bolt and nut materials and the finishing processing might prevent the loss in the clamping pressure during the fretting testing. It is important to control the specification of these components (clamps, bolt and nuts) prior to the start of large scale fretting fatigue testing of the overhead conductors in order to increase the reproducibility of this assessment. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
P>Typing methods to evaluate isolates in relation to their phenotypical and molecular characteristics are essential in epidemiological studies. In this study, Candida albicans biotypes were determined before and after storage in order to verify their stability. Twenty C. albicans isolates were typed by Randomly Amplified Polymorphic DNA (RAPD), production of phospholipase and proteinase exoenzymes (enzymotyping) and morphotyping before and after 180 days of storage in Sabouraud dextrose agar (SDA) and sterilised distilled water. Before the storage, 19 RAPD patterns, two enzymotypes and eight morphotypes were identified. The fragment patterns obtained by RAPD, on the one hand, were not significantly altered after storage. On the other hand, the majority of the isolates changed their enzymotype and morphotype after storage. RAPD typing provided the better discriminatory index (DI) among isolates (DI = 0.995) and maintained the profile identified, thereby confirming its utility in epidemiological surveys. Based on the low reproducibility observed after storage in SDA and distilled water by morphotyping (DI = 0.853) and enzymotyping (DI = 0.521), the use of these techniques is not recommended on stored isolates.
Resumo:
This study aimed to determine the occurrence of symptoms of binge eating (BE) among children and adolescents seeking treatment for their obesity, as well as to evaluate their diet composition and metabolic characteristics. The Binge Eating scale (BES) was answered by 128 children and adolescents (10.77 +/- 2.04 years, BMI 29.15 +/- 4.98 kg/m(2), BMI Z score 2.28 +/- 0.46, 53.91% pubescent), who were classified into two subgroups-binge eaters (score greater than or equal to IS points) and non-binge eaters (score lower than 18 points). Anthropometric data, body composition and Tanner stages were collected and dietary evaluation conducted. Blood pressure was determined, and glucose, lipid profile and insulin assays were performed. insulin resistance was determined using HOMA-IR. BE symptoms were present in 39.06% of patients. Carbohydrate intake in diet composition was significantly higher among binge eaters. Children with BE did not demonstrate significant dissimilar metabolic characteristics when compared to their counterparts without BE. Therefore, BE seems to be a prevalent problem among children and adolescents seeking help for their obesity. When associated with obesity, this eating behaviour can influence macronutrient consumption through increased carbohydrate intake. Further research would be valuable to verify the reproducibility of these findings. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Aortic valve calcium (AVC) can be quantified on the same computed tomographic scan as coronary artery calcium (CAC). Although CAC is an established predictor of cardiovascular events, limited evidence is available for an independent predictive value for AVC. We studied a cohort of 8,401 asymptomatic subjects (mean age 53 10 years, 69% men), who were free of known coronary heart disease and were undergoing electron beam computed tomography for assessment of subclinical atherosclerosis. The patients were followed for a median of 5 years (range 1 to 7) for the occurrence of mortality from any cause. Multivariate Cox regression models were developed to predict all-cause mortality according to the presence of AVC. A total of 517 patients (6%) had AVC on electron beam computed tomography. During follow-up, 124 patients died (1.5%), for an overall survival rate of 96.1% and 98.7% for those with and without AVC, respectively (hazard ratio 3.39, 95% confidence interval 2.09 to 5.49). After adjustment for age, gender, hypertension, dyslipidemia, diabetes mellitus, smoking, and a family history of premature coronary heart disease, AVC remained a significant predictor of mortality (hazard ratio 1.82, 95% confidence interval 1.11 to 2.98). Likelihood ratio chi-square statistics demonstrated that the addition of AVC contributed significantly to the prediction of mortality in a model adjusted for traditional risk factors (chi-square = 5.03, p = 0.03) as well as traditional risk factors plus the presence of CAC (chi-square = 3.58, p = 0.05). In conclusion, AVC was associated with increased all-cause mortality, independent of the traditional risk factors and the presence of CAC. (C) 2010 Published by Elsevier Inc. (Am J Cardiol 2010;106:1787-1791)
Resumo:
Objective. There are no data to support the suggestion that samples removed from one segment of the transplanted kidney are representative of the whole graft. The aim of this study was to compare the histological differences between biopsies obtained from different portions of the renal allograft and their impact on treatment recommendations. Patients and Methods. Two hundred percutaneous biopsies were performed on kidney allografts and samples were collected from the upper and lower poles (100 kidneys). All samples were randomized and blindly reviewed. We obtained the discordance rates between the poles for the grading of acute rejection and for the diagnosis of nephrotoxicity due to immunosuppression. We also checked if the differences found were sufficient to call for different clinical recommendations. These values were compared with the intrapathologist variation rates. Results. In 70 kidneys adequate sampling was obtained from both poles. The diagnosis of acute rejection were made in 1.7. The discordance rate between the upper and lower poles was 82.3% (kappa = 0.34), higher than the intrapathologist variation (P =.002). Nephrotoxicity was found in 14 kidneys. The discordance rate between the upper and lower poles was 28.6% (kappa = 0.88), with no difference compared with the intrapathologist variation. In 14 of the 70 kidneys (25.7%), discordances between poles had impact on clinical recommendations, most of these cases due to different gradings of acute rejection (78%). This number was higher than the intrapathologist variation (P =.04). Conclusions. The histopathological changes in the kidney allograft are not always homogeneous. This heterogeneity may affect the therapeutic recommendations.
Resumo:
The level of fractional exhaled nitric oxide (FENO) is significantly elevated in uncontrolled asthma and decreases after anti-inflammatory therapy The aim of this prospective study was to analyze the behavior of FENO in the follow-up and management of the inflammation in asthmatic pediatric patients treated with inhaled corticosteroids (ICS), compared to sputum cellularity, serum interleukins (IL), and pulmonary function. Twenty-six clinically stable asthmatic children aged from 6 to 18 years, previously treated or not with ICS were included. Following an international consensus (GINA), the patients were submitted to standard treatment with inhaled fluticasone for 3 months according to the severity of the disease. During this period, each patient underwent three assessments at intervals of approximately 6 weeks: Each evaluation consisted of the measurement of FENO, determination of serum interleukins IL-5, IL-10, IL-13, and interferon gamma (INF-gamma), spirometry and cytological analysis of spontaneous or induced sputum. A significant reduction in mean FENO and IL-5, without concomitant changes in FEV1, was observed along the study. There was no significant correlation between FeNO and FEV1 in the three assessments. A significant correlation between FeNO and IL-5 levels was only observed in the third assessment (r = 0.499, P=0.025). In most patients, serum IL-10, IL-13, and INF-gamma concentrations were undetectable throughout the study Sputum samples were obtained spontaneously in 11 occasions and in 56 by induction with 3% hypertonic saline solution (success rate: 50.8%), with 39 (69.9%) of them adequate for analysis. Only two of the 26 patients produced adequate samples in the three consecutive evaluations, which impaired the determination of a potential association between sputum cellularity and FeNO levels throughout the study. In conclusion, among the parameters of this study, it was difficult to perform and to interpret the serial analysis of spontaneous or induced sputum. Serum interleukins, which remained at very low or undetectable levels in most patients, were not found to be useful for therapeutic monitoring, except for IL-5 that seems to present some correlation with levels of FeNO exhaled. Monitoring of the mean FEV1 indicated no significant variations during the treatment, demonstrating that functional stability or the absence of obstruction may not reflect the adequate management of asthma. Serial measurement of FeNO seemed to best reflect the progressive anti-inflammatory action of ICS in asthma.
Resumo:
Background: Color Doppler myocardial imaging (CDMI) allows the calculation of local longitudinal or radial strain rate (SR) and strain (epsilon). The aims of this study were to determine the feasibility and reproducibility of longitudinal and radial SR and epsilon in neonates during the first hours of life and to establish reference values. Methods: Data were obtained from 55 healthy neonates (29 male; mean age, 20 +/- 14 hours; mean birth weight, 3,174 +/- 374 g). Apical and parasternal views quantified regional longitudinal and radial SR and epsilon in differing ventricular wall segments. Values at peak systole, early diastole, and late diastole were calculated from the extracted curves. CDMI data acquired at 300 +/- 50 frames/s were analyzed offline. Three consecutive cardiac cycles were measured during normal respiration. The timing of specific systolic or diastolic regional events was determined. Multiple comparisons between walls and segments were made. Results: Left ventricular (LV) longitudinal deformation showed basal differences compared with apical segments within one specific wall. Right ventricular (RV) longitudinal deformation was not homogeneous, with significant differences between basal and apical segments. Longitudinal 3 values were higher in the RV free basal and middle wall segments compared with the left ventricle. In the RV free wall apical segment, longitudinal SR and 3 were maximal. LV systolic SR and epsilon values were higher radially compared with longitudinally (radial peak systolic SR midportion, 2.9 +/- 0.6 s(-1); radial peak systolic epsilon 53.8 +/- 19%; longitudinal peak systolic SR midportion, -1.8 +/- 0.5 s(-1); longitudinal peak systolic epsilon, -24.8 +/- 3%; P < .01). Longitudinal systolic epsilon and SR interobserver variability values were 1.2% and 0.7%, respectively. Conclusion: Ultrasound-based SR and 3 imaging is a practical and reproducible clinical technique in neonates, allowing the calculation of regional longitudinal and radial deformation in RV and LV segments. These regional SR and epsilon indices represent new, noninvasive parameters that can quantify normal neonate regional cardiac function. Independent from visual interpretation, they can be used as reference values for diagnosis in ill neonates. (J Am Soc Echocardiogr 2009;22:369-375.)
Resumo:
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
Resumo:
This study vas aimed to validate the American Speech-Language-Hearing Association Functional Assessment Of Communication Skills (ASHA FACS) for a Brazilian population. The scale was translated and adapted into Portuguese. Thirty-two patients with mild Alzheimer disease (AD). 25 patients with moderate AD. and 51 elderly without dementia were examined with Mini Mental State Examination, Geriatric Depression Scale. and Alzheimer Disease Assessment Scale-Cognitive subscale (ADAS-cog). The ASHA FACS was answered by their relative/caregiver. The scale`s internal consistency. its inter-examiner and intra-examiner`s reproducibility. and scale`s criterion validity were researched by correlation with ADAS-cog,. The sensitivity and specificity Were also researched. Statistical analyses indicated that the ASHA FACS has excellent internal consistency (Cronbach alpha = 0.955), test-retest reliability (interclass correlation coefficient = 0.995; P < 0.001). and inter-examiners (interclass correlation coefficient = 0.998: P < 0.001). It showed excellent criterion validity when correlated with ADAS-cog,. The ASHA FACS scale showed good sensitivity (75.0%) and specificity (82.4%) values once it is an ecologic and broad evaluation. The ASHA FACS Portuguese version is a valid and reliable instrument to verify communication alterations in AD patients and fills an important gap of efficiency indicators for speech language therapy in our country.
Resumo:
Background. The mechanical alterations related to the overload of respiratory muscles observed in adults with persistent asthma might lead to the development of chronic alterations in posture, musculoskeletal dysfunction and pain; however, these changes remain poorly understood. Objective. This study aimed to assess postural alignment, muscle shortening and chronic pain in adults with persistent asthma. Methods. This cross-sectional and controlled study enrolled 30 patients with mild (n = 17) and severe ( n = 13) persistent asthma. Fifteen non-asthmatic volunteers were also assessed. Asthma was classified by the Global Initiative for Asthma (GINA) guidelines. Postural alignment and muscle shortening were evaluated by head and shoulder positions, chest wall mobility, and posterior ( trunk and lower limb) muscle flexibility. In addition, the measures used were previously tested for their reproducibility. Pain complaints were also assessed. Results. In comparison with non-asthmatic subjects, patients with mild or severe persistent asthma held their head and shoulders more forward and had lower chest wall expansion, decreased shoulder internal rotation, and decreased thoracic spine flexibility. Chronic lower thoracic, cervical, and shoulder pain was significantly increased in patients with mild or severe asthma compared with non-asthmatic subjects (p < 0.05). Conclusion. Adults with persistent asthma have musculoskeletal dysfunction and chronic pain that is independent of the severity of their disease but that might be related to their age at the onset of disease symptoms.
Resumo:
The authors developed an evaluation scale for sit-stand from the ground for children with Duchenne muscular dystrophy (DMD) and tested its reliability. The construction occurred in stages: (a) the characterization of the movement in healthy children, (b) the characterization of the movement in children with DMD, (c) the elaboration of the 1st version of the scale and the manual, (d) the evaluation by experts and readjustments, and (e) the analysis of inter- and intraexaminer reliability and correlation with the Vignos Scale, age, and time for the execution of the activity. The scale comprehended 3 phases for sitting and 5 for the standing. A very good repeatability of the measures of sitting and standing (ICC = 0.89 and 0.84, respectively) and excellent reproducibility (ICC = 0.93 and 0.92, respectively) was demonstrated. The Kappa coefficient for the 8 phases in the interexaminer analysis varied from 0.77 to 1.00 (excellent reliability), and in the intraexaminer analysis varied from 0.80 to 1.00 (excellent reliability). Good correlation was found between the variables on the Vignos Scale (age: r = 0.58; stand: r = 0.56). The scale is a reliability instrument that allows evaluation of the activity of sitting and standing in children with DMD.
Resumo:
The Douleur Neuropathique 4 (DN4) questionnaire was developed by the French Neuropathic Pain Group and is a simple and objective tool, with the ability to distinguish nociceptive from neuropathic pain. The purpose of this work was to validate the DN4 questionnaire in the Portuguese language in order to allow its use in clinical and research settings. A double-blind, accuracy study was conducted, consisting of translation, back-translation, literal evaluation, semantic equivalence, and communication with the target population. The Portuguese version of the questionnaire was applied in a sample of 101 patients with neuropathic (N = 42) or nociceptive pain (N = 59), ranked according to medical diagnosis. The reproducibility, reliability and validity of the instrument were analyzed, and showed a high diagnostic power for this version of the DN4 questionnaire. The Portuguese version of the DN4 questionnaire presented good validity and reliability, allowing it to identify neuropathic pain and neuropathic characteristics of mixed pain syndromes. Perspective: This article presents the first validated neuropathic pain questionnaire in the Portuguese language and represents a useful tool in the assessment of neuropathic pain both in the clinical setting and in population-based studies. The sensible and quick format of this instrument are key factors that will contribute to its widespread use, permitting a true recognition of patients with neuropathic pain. (C) 2010 by the American Pain Society