77 resultados para polyester prosthesis
Resumo:
The formation of the Mn(III)/EDTA complex in a flow system with solenoid micro-pumps was exploited for fast manganese determination in freshwater. Manganese(II) was oxidized in a solid-phase reactor containing lead dioxide immobilized on polyester. Long pathlength spectrophotometry was exploited to increase sensitivity, aiming to reach the threshold limit established by environmental legislation. A linear response was observed from 25 to 1500 mu g L(-1), with a detection limit of 6 mu g L(-1) (99.7% confidence level). Sample throughput and coefficient of variation were 36 samples/h and 2.6% (n = 10), respectively. EDTA consumption and waste generation were estimated as 500 mu g and 3 mL per determination, respectively. The amount of Pb in the residue corresponds to 250 mu g per determination and a solid-phase reactor could be used for up to 1600 determinations. Adsorption in active charcoal avoided interferences caused by organic matter and the developed procedure was successfully applied for determination of manganese in freshwater samples. Results were in agreement with those attained by GFAAS at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Objective: To evaluate the potential risk of surgical contamination by the venting port of ordinary electric drills (ED) employed in orthopaedic surgeries. Materials and Methods: an experimental laboratory, randomized study was developed to analyze EDs in surgical practice and new cleaned and sterilized equipment, which were contaminated with Bacillus atrophaeus spores at a concentration of 84 X 10(6) UFC. The air generated by the engine of each drill was collected and cultivated on sterile agar plates. Results: Positive culture was identified in two ED in surgical practice, as well as a positive culture to Bacillus atrophaeus with 1 CFU growth (1, 19 X 10(-8)). Conclusion: In the conditions of the experiment, the air generated by the venting port of the ED`s engine does not consist of a source of contamination for the surgical site.
Resumo:
Geosynthetics interlayer systems are effective techniques to control reflective cracking in damaged pavements. It comprises the inclusion of nonwoven geotextiles between the damaged layer and the new overlay of the pavement to reduce the propagation of cracks and to extend pavement life. However, the success of this technique depends directly on the understanding of the geotextile`s behavior when impregnated with asphalt This paper evaluates different nonwoven geotextiles frequently used in anti-reflective cracking systems, focusing on initial stiffness gain and permeability reduction after asphalt impregnation. Fresh and impregnated samples of polyester and polypropylene nonwoven geotextiles were tested. Cationic rapid setting emulsified asphalt was used as asphalt binder. Wide-width tensile tests were carried out based on the specification of ABNT - NBR 12824 (1993). Water vapor transmission tests were conducted according to ASTM E 96M (2005). Results of tensile tests on impregnated geotextiles showed a significant increase on tensile strength values, probably due to the inter contact of the fibers. Results also showed high increase in strength values at strain levels less than 0.05% and decrease on stiffness gains with increase of strains. Water vapor transmission tests demonstrated that cationic asphalt emulsion applied on nonwoven geotextiles allows a drastic reduction in permeability values to turn nonwoven geotextiles into a low permeability barrier. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to evaluate the potential of the fibrous material obtained from ethanol-water fractionation of bagasse as reinforcement of thermoplastic starches in order to improve their mechanical properties. The composites were elaborated using matrices of corn and cassava starches plasticized with 30 wt%glycerin. The mixtures (0,5,10 and 15 wt% bagasse fiber) were elaborated in a rheometer at 150 degrees C. The mixtures obtained were pressed on a hot plate press at 155 degrees C. The test specimens were obtained according to ASTM D638. Tensile tests, moisture absorption tests for 24 days (20-23 degrees C and 53% RH, ASTM E104), and dynamic-mechanical analyses (DMA) in tensile mode were carried out. Images by scanning electron microscopy (SEM) and X-ray diffraction were obtained. Fibers (10 wt% bagasse fiber) increased tensile strength by 44% and 47% compared to corn and cassava starches, respectively. The reinforcement (15 wt% bagasse fiber) increased more than fourfold the elastic modulus on starch matrices. The storage modulus at 30 C (E(30 degrees C)`) increased as the bagasse fiber content increased, following the trend of tensile elastic modulus. The results indicate that these fibers have potential applications in the development of biodegradable composite materials. (c) 2011 Elsevier B.V. All rights reserved.
Resumo:
In order to lower the excessive costs of metallic prosthesis materia Is alternatives to Ti and Ti alloys have been searched. in this study, the corrosion resistance of the DIN 1.4575 superferritic stainless steel, either solution annealed or solution annealed and aged at 475 degrees C for periods varying from 100 to 1080 h, was investigated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization methods in Hanks` solution. The solution annealed and the aged for 1080 h samples were also tested using scanning electrochemical microscopy (SECM) in a 0.1 mol/L NaCl solution at 25 degrees C. The EIS results showed that the corrosion resistance of the DIN 1.4575 steel decreases with heat treatment time at 475 degrees C probably due to alpha prime formation. Besides the diminution of the overall impedance values, the low frequency limit of the Nyquist diagrams show a progressive change from an almost capacitive response to a resistive behavior as the heat treatment time increases. Pitting corrosion resistance also decreased with aging time at 475 degrees C.
Resumo:
Freeze-drying of biological tissues allows for dry storage and gamma ray sterilization, which may improve their use as a medical prosthesis. The objective of this study was to evaluate the rehydration characteristics and hydrodynamic performance of prosthetic valves before and after lyophilization. Two size 23 bovine pericardium aortic valve prostheses from different manufacturers were evaluated in a Shelhigh (Union, NJ, USA) pulse duplicator (80 ppm, 5 L/min) before and after lyophilization. Flow and transvalvular pressure gradient were registered in vitro and in vivo, and images of opening and closing of the prosthesis were obtained in the pulse duplicator in a digital camera. Rehydration was evaluated by comparison of dry valve weight with valve weight after 15 min, and 1, 24, 48, and 72 h in saline solution, inside the pulse duplicator. In vivo performance was assessed by surgical implantation in Santa Ines young male sheep in the pulmonary position after 30 min rehydration with 0.9% saline. Transvalvular pressure gradient and flow measurements were obtained immediately after implantation and 3 months after surgery when valves were explanted. Captured images showed a change in the profile opening and closing of valve prosthesis after lyophilization. The gradient measured (in vitro) in two valves was 17.08 +/- 0.57 and 18.76 +/- 0.70 mm Hg before lyophilization, and 34.24 +/- 0.59 and 30.40 +/- 0.97 mm Hg after lyophilization. Rehydration of both lyophilized valves was approximately 82%. Drying changed the profile of the opening and closing of valve prostheses, and increased on average by 83% the gradient in vitro tests. The result of the in vivo tests suggests maintaining pressure levels of the animal with the lyophilized prostheses within acceptable levels.
Resumo:
In this work we studied the mixture of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS), a commercial polymer, with monobasic potassium phosphate (KDP), a piezoelectric salt, as a possible novel material in the fabrication of a low cost, easy-to-make,flexible pressure sensing device. The mixture between KDP and PEDOT: PSS was painted in a flexible polyester substrate and dried. Afterwards, I x V curves were carried out. The samples containing KDP presented higher values of current in smaller voltages than the PEDOT: PSS without KDP. This can mean a change in the chain arrays. Other results showed that the material responds to directly applied pressure to the sample that can be useful to sensors fabrication. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
After massive weight loss, one of the stigmas that afflict women is the remaining deformity of the breasts which become flaccid and ptotic, with an absent or flat upper pole. The authors propose the use of a well-established mammaplasty technique to fill the upper pole, reshape the breast cone, and correct ptosis with nipple-areola complex (NAC) repositioning. A total of 16 patients were analyzed; all underwent gastroplasty between 18 and 24 months prior to mammaplasty. The mean age was 41.6 years (range = 26-62) and the mean BMI previous to the mammaplasty was 29.2 kg/m(2) (range = 24.9-38.9). The technique included a dermo-lipo glandular flap pedicled on the inframammary fold (IMF) together with a superior flap containing the NAC. All patients who underwent surgery were satisfied with the outcomes since a more aesthetic breast shape was achieved, with projection of the upper pole and correction of ptosis. Adverse events included dehiscence at the junction point of the flaps in the inframammary fold, which resolved with secondary-intention wound healing in three patients; partial necrosis of the areola in one patient; epidermolysis in one of the NACs in one patient; and infection in one of the breasts in one patient, which resolved with proper antibiotic therapy. When compared to the current mammaplasty techniques performed in formerly obese patients, this is a good surgical option because it uses tissues adjacent to the breast itself and does not require silicone prosthesis for breast augmentation. The patients reported increased self-esteem and improvement in their quality of life.
Resumo:
Objective: To assess, in patients undergoing glossectomy, the influence of the palatal augmentation prosthesis on the speech intelligibility and acoustic spectrographic characteristics of the formants of oral vowels in Brazilian Portuguese, specifically the first 3 formants (F1 [/a,e,u/], F2 [/o,o,u/], and F3 [/a,o/]). Design: Speech evaluation with and without a palatal augmentation prosthesis using blinded randomized listener judgments. Setting: Tertiary referral center. Patients: Thirty-six patients (33 men and 3 women) aged 30 to 80 (mean [SD], 53.9 [10.5]) years underwent glossectomy (14, total glossectomy; 12, total glossectomy and partial mandibulectomy; 6, hemiglossectomy; and 4, subtotal glossectomy) with use of the augmentation prosthesis for at least 3 months before inclusion in the study. Main Outcome Measures: Spontaneous speech intel-ligibility (assessed by expert listeners using a 4-category scale) and spectrographic formants assessment. Results: We found a statistically significant improvement of spontaneous speech intelligibility and the average number of correctly identified syllables with the use of the prosthesis (P < .05). Statistically significant differences occurred for the F1 values of the vowels /a,e,u/; for F2 values, there was a significant difference of the vowels /o,o,u/; and for F3 values, there was a significant difference of the vowels la,61 (P < .001). Conclusions: The palatal augmentation prosthesis improved the intelligibility of spontaneous speech and syllables for patients who underwent glossectomy. It also increased the F2 and F3 values for all vowels and the F I values for the vowels /o,o,u/. This effect brought the values of many vowel formants closer to normal.
Resumo:
Femoral and acetabular loosening call be attributed different factors, but the Causes and mechanism of early failure are still obscure, The objective of this Study was to investigate the relationship between gene polymorphisms and early implant failure. Fifty-eight patients older than 50 years was recruited for analysis of MMP-1 promoter polymorphisms in early osseointegrated implant failure. The results showed in control group a frequency of 20.97% of 2G allele and 67.74% the genotype 1G/1G whereas, in the test group, a frequency of 83.33% of 2G allele and 66.66% the genotype 2G/2G. These results indicate that the polymorphism ill the promoter of the MMP-1 gene could be it risk factor for early implant failure of total hip arthroplasty.
Resumo:
Introduction: Total knee arthroplasty (TKA) imposes many risks. TKA infection is not the most frequent complication, but is probably the most serious one. Two-step review is the procedure of choice in deep knee prosthesis infection. On the other hand, aseptic prosthesis detachment represents almost half of the primary arthroplasty review indications, Patient`s satisfaction level might diminish after reviews. Objective: The objective of this study was to compare the quality of life and final result of TKA review for septic and aseptic failures. Methods: The patients were assessed using the HSS and SF-36 scores. The patients were divided in two groups: one group submitted to two-step review (septic) and the other to one-step review (aseptic). The analysis of the data obtained shows better scores for the second group in HSS and in 06 of 08 domains of SF-36 classification. Conclusions: The on-step review of total knee arthroplasty leads to better functional outcomes.
Resumo:
Background: In this study, we analyzed the time course of hemodynamic efficiency and follow-up in Fontan candidates who underwent the bidirectional Glenn procedure for staged intracardiac cavopulmonary connection (ICPC). Methods: Between 1991 and 2008, 52 patients with univentricular heart (mean age, 3.3 years; range, 2-8 years; 27 female patients [51.9%]) underwent ICPC. The cardiac malformations were as follows: tricuspid atresia, 25 cases (48.0%); common ventricle, 16 cases (30.7%); and pulmonary atresia with intact ventricular septum, 11 cases (21.1%). The intracardiac cavopulmonary procedure was indicated for all 52 cases. In 42 patients (80.7%), an intra-atrial lateral tunnel was constructed with a bovine pericardium patch. In the last 10 consecutive cases (19.3%), we performed a modified surgical technique in which we implanted an intra-atrial corrugated bovine pericardium tube sutured around the superior and inferior vena cava ostium. In all cases, a 4-mm fenestration was made to reduce the intratunnel pressure. All 52 patients had previously undergone a Glenn operation. Results: There were 2 hospital deaths (3.8%) and no recorded late deaths. During the follow-up, all patients were medicated with antiplatelet drugs. To evaluate the hemodynamic performance, we used Doppler echocardiography, computed tomography, and magnetic nuclear resonance studies. There were no prosthesis thromboses during this follow-up period. To evaluate cardiac arrhythmias, we conducted a Holter study. The last 10 patients with an intra-atrial conduit (IAC) presented with sinus rhythm and no arrhythmias during the last 4 years. The 50 surviving patients (96.1%) have been followed up for 6 to 204 months; all these patients are free of reoperation. Conclusion: The Glenn operation, which is performed at an early age, prepares the pulmonary bed to receive the ICPC. The midterm results of the intracardiac Fontan procedure seem to be good. The modified surgical procedure (IAC) can be a good alternative technique to the Fontan procedure in suitable patients.
Resumo:
Involvement of the celiac trunk and common hepatic artery are two of the most common forms of vascular invasion by tumours of the distal pancreas, and until recently this finding was considered a contra-indication to resection. We described a modified Appleby operation for locally advanced distal pancreatic cancer with compromised hepatic collateral flow that needed hepatic arterial revascularization, successfully accomplished by left external iliac-hepatic arterial bypass with Dacron prosthesis. Patient recovery was uneventful and he was discharged on the 10th postoperative day. Postoperative angio-CT disclosed a patent arterial bypass. Patient is well and asymptomatic 13 months after operation. At the time of this writing, postoperative CT scan showed no evidence of disease and CA 19-9 level is normal. There is a well established rationale to perform extended resection of pancreatic carcinomas that compromise vascular structures. Modified Appleby procedure can safely be performed, has oncological advantages to palliative procedures and provides relief of pain but is reserved for selected patients. Preservation of hepatic arterial flow has utmost importance to avoid hepatobiliary complications as liver necrosis, liver abscess, gallbladder necrosis or cholecystitis. In this case, hepatic revascularization was particularly challenging, but was successfully accomplished by left external iliac-hepatic arterial bypass. To our knowledge this type of arterial bypass has never been described so far in the English literature and its description may be important for surgeons dealing with advanced pancreatic cancer. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Objective: The aim of this study is to evaluate the use of cement spacers impregnated with antibiotics for the treatment of infections in the nonconventional endoprostheses of the knee. Methodology: We have treated seven patients since 2004 (of which six were submitted to surgery in our service and one patient had been submitted to a primary tumor surgery in another removal service) with deep infection in knee tumor prosthesis. All patients were submitted to endoprosthesis removal and reconstructed with antibiotic cement spacer All patients were monitored both clinically and by lab tests as for monitoring the evolution, being considered able for reviews after 6 (six) months without infections signs. Results: We have noted a small predominance of infectious processes on the prosthesis inserted on proximal tibia as compared with distal femur (57.1% x 42.9%). The mean follow-up time of patients was 68.2 months. During the follow up, one patient died as a result of the root disease. Six patients out of seven were regarded as cured and one persisted with infection signs and symptoms. Conclusion: The results obtained up to date have motivated us to continue using this method of treatment.
Resumo:
Objective: In total knee arthroplasty, the minimally-invasive approach has been claimed to enable earlier rehabilitation because it spares the femoral quadriceps muscle. To check the influence of preserving the extensor apparatus during surgery, the strength of knee extension and flexion muscles was evaluated in patients submitted to total knee arthroplasty with different approaches. Materials and Methods: The values of maximum torque and total work obtained by isokinetic dynamometry six months after surgery were compared for the Minimally invasive surgery group constituted of 12 individuals submitted to total knee arthroplasty by the minimally invasive surgical approach and the Control group, constituted of eight patients submitted to total knee arthroplasty by the transquadricipital approach, between January 2005 and July 2006. Results: Statistical analysis of the absolute values for maximum torque and total work adjusted for body weights did not show differences between both groups. Conclusion: There was no difference in the extension and flexion strength of the knee muscles six months after surgery.