96 resultados para normal spine
Resumo:
OBJECTIVES To determine the serum total prostate-specific antigen (tPSA) levels in cirrhotic men and compare them with those in noncirrhotic men. METHODS We prospectively evaluated 113 cirrhotic patients listed for liver transplantation using the serum tPSA, total testosterone level, and Child-Pugh liver function score according to age and severity of liver disease. The tPSA levels were compared with those of 661 healthy men. The Mann-Whitney U test was used for statistical analysis, with a significance level of .05. RESULTS The median age of the cirrhotic and noncirrhotic patients was 55 years (range 28-70) and 58 years (range 46-70), respectively (P <.01). However, when stratified by age group (<49, 50-59, and >60 years), this difference was not significant. The median serum tPSA level was 0.3 ng/mL (range 0.04-9-9) and 1.3 ng/mL (range 0.04-65.8) in the cirrhotic and noncirrhotic group, respectively (P <.0001). Stratifying both groups according to age, the cirrhotic patients had significantly lower tPSA levels than did the noncirrhotic patients. According to the Child-Pugh score (A,B, and C), Child-Pugh class C patients had significantly lower tPSA levels than did Child-Pugh class A patients and also had lower testosterone levels than did Child-Pugh class A and B patients. The tPSA levels correlated significantly with the testosterone levels in the cirrhotic patients (P =.028). CONCLUSIONS The results of our study have shown that cirrhotic patients have approximately 4 times lower serum tPSA levels than noncirrhotic men. Patients with more severe liver disease have lower tPSA and testosterone levels than patients less affected. The tPSA levels in cirrhotic men are affected by the total testosterone levels. UROLOGY 73: 1032-1035, 2009. (C) 2009 Elsevier Inc.
Resumo:
The longest open reading frame of PKHD1 (polycystic kidney and hepatic disease 1), the autosomal recessive polycystic kidney disease (ARPKD) gene, encodes a single-pass, integral membrane protein named polyductin or fibrocystin. A fusion protein comprising its intracellular C-terminus, FP2, was previously used to raise a polyclonal antiserum shown to detect polyductin in several human tissues, including liver. In the current study, we aimed to investigate by immunohistochemistry the detailed polyductin localization pattern in normal (ductal plate [DP], remodelling ductal plate [RDP], remodelled bile ducts) and abnormal development of the primitive intrahepatic biliary system, known as ductal plate malformation (DPM). This work also included the characterization of polyductin expression profile in various histological forms of neonatal and infantile cholestasis, and in cholangiocellular carcinoma (CCC) and hepatocellular carcinoma (HCC). We detected polyductin expression in the intrahepatic biliary system during the DP and the RDP stages as well as in DPM. No specific staining was found at the stage of remodelled bile ducts. Polyductin was also detected in liver biopsies with neonatal cholestasis, including mainly biliary atresia and neonatal hepatitis with ductular reaction as well as congenital hepatic fibrosis. In addition, polyductin was present in CCC, whereas it was absent in HCC. Polyductin was also co-localized in some DP cells together with oval stem cell markers. These results represent the first systematic study of polyductin expression in human pathologies associated with abnormal development of intrahepatic biliary tree, and support the following conclusions: (i) polyductin expression mirrors developmental properties of the primitive intrahepatic biliary system; (ii) polyductin is re-expressed in pathological conditions associated with DPM and (iii) polyductin might be a potential marker to distinguish CCC from HCC.
Resumo:
Background: Many questions remain unanswered about premature atherosclerosis in rheumatoid arthritis (RA). Besides inflammation, some studies have suggested the role of autoantibodies on its pathogenesis. Objective: The aim of this study was to investigate the presence of antibodies against phospholipids, beta2-glycoproteinl (beta2-gpl), lipoprotein lipase, and heat shock proteins (Hsp) in RA patients and to evaluate their possible association with subclinical carotid atherosclerosis. Methods: Seventy-one RA patients and 53 age- and sex-matched controls were selected to perform anticardiolipin antibodies (aCL) (IgG and IgM), anti-beta2-gpl (IgG, IgM, and IgA), anti-lipoprotein lipase (anti-LPL), anti-Hsp 60, and anti-Hsp 65 by ELISA tests. Intima-medial thickness (IMT) of common carotid and presence of plaques were assessed by high-resolution B-mode ultrasonography. Exclusion criteria were smoking, diabetes, and arterial hypertension. Lipoproteins, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and fibrinogen levels, as well as health assessment questionnaire (HAQ) and disease activity score (DAS) 28 were also evaluated. Results: Age (48.93 +/- 12.31 vs. 45.37 +/- 9.37 years; p = 0.20) and body mass index (BMI) (p = 0.69) were similar in RA and controls, as well as female gender (p = 0.56). The mean IMT was similar between RA and controls (0. 721 +/- 0.16 vs. 0.667 +/- 0.14 turn, p = 0.07) but the frequency of plaques was higher in RA (14.1% vs. 1.9%; p = 0.02). In RA patients, IMT measurements did not differ according to the presence or absence of these antibodies: IgG aCL (0.62 +/- 0.64 vs. 0.72 +/- 0.17 mm, p = 0.24), IgM aCL (0.65 +/- 0.79 vs. 0.73 +/- 0.17 mm, p = 0.33), anti-Hsp 60 (0.78 +/- 0.20 vs. 0.71 +/- 0.16 mm, p = 0.27), anti-Hsp 65 (0.73 +/- 0.16 vs. 0.72 +/- 0.17 mm, p = 0.77), IgG anti-beta2-gpl (0.73 +/- 0.16 vs. 0.71 +/- 0.17 mm, p = 0.72), and anti-CCP (0.71 +/- 0.16 vs. 0.76 +/- 0.20 mm, p = 0.36). In addition, IMT did not correlate with antibodies titers: IgG aCL (r = -0.09, p = 0.47), IgM aCL (r = - 0.15, p = 0.21), anti-Hsp 60 (r = 0.10, p = 0.42), anti-Hsp 65 (r = 0.05, p = 0.69), IgG anti-beta2-gpl (r = - 0.07, p = 0.57), IgM anti-beta2-gpl (r = - 0.05, p = 0.69), IgA anti-beta2-gpl (r = 0.03, p = 0.79), and anti-CCP (r = - 0.07, p = 0.57). RA patients with plaques had a significantly higher age compared to those without plaques (p = 0.001), as well as higher mean IMT (p < 0.001), total cholesterol (p = 0.001), and LDL (p = 0.003). Conclusions: In RA a clear association between all autoantibodies studied herein and increased IMT or presence of plaques was not observed. The great prevalence of carotid atherosclerosis in RA was related to age, total and LDL cholesterol, as identified in normal population. (c) 2008 Elsevier Masson SAS. All rights reserved.
Resumo:
Gut hormones Ighrelin, peptide YY (PYY) and ghrcagon-like peptide-1 (GLP-1)] are an important group of hormones that target appetite control. They are released from endocrine L cells of the small bowel in proportion to the volume, components and calories in a meal. In the current study, 20 g of gelatin (flavored and sweetened) were given to obese patients (n=12) and lean subjects (n=10). Subsequently, plasma samples were collected at-30-minute intervals rip to 180 minutes and glucose, insulin, PYY, GLP-1 and ghrelin were assayed using specific and sensitive immunofluorometric and radioimmunoassays. As expected, obese patients had normal serum glucose levels, higher serum insulin, and lower plasma concentration of ghrelin at all times compared to lean subjects. GLP-1 plasma levels were significantly elevated at 60 minutes, peaking at 120 minutes in obese patients and lean subjects. As a consequence, there was a significant rise in serum insulin levels with a significantly higher peak level at 60 min (obese) and 30 min (lean). There were no significant changes in PYY plasma concentrations and no correlation was found between body mass index and concentrations of ghrelin, PYY and GLP-1 in the group of obese patients. In conclusion, a single gelatin meal induces a rise in plasma GLP-1 followed by an increase in serum levels of insulin. These findings may be applied to maximize satiety in obese patients as a means of improving adherence to calorie-controlled diets as well as provide better control of diabetic patients.
Resumo:
Juvenile onset systemic sclerosis (JoSSc) is a rare disease, and there are no studies focusing in bone mineral density and biochemical bone parameters. Ten consecutive patients with JoSSc and 10 controls gender, age, menarche age, and physical activity matched were selected. Clinical data were obtained at the medical visit and chart review. Laboratorial analysis included autoantibodies, 25-hydroxyvitamin D (25OHD), intact parathyroid hormone, calcium, phosphorus, alkaline phosphatase and albumin sera levels. Bone mineral density was analyzed by dual-energy X-ray absorptiometry, and bone mineral apparent density (BMAD) was calculated. A lower BMAD in femoral neck (0.294 +/- A 0.060 vs. 0.395 +/- A 0.048 g/cm(3), P = 0.001) and total femur (0.134 +/- A 0.021 vs. 0.171 +/- A 0.022 g/cm(3), P = 0.002) was observed in JoSSc compared to controls. Likewise, a trend to lower BMAD in lumbar spine (0.117 +/- A 0.013 vs. 0.119 +/- A 0.012 g/cm(3), P = 0.06) was also found in these patients. Serum levels of 25OHD were significantly lower in JoSSc compared to controls (18.1 +/- A 6.4 vs. 25.1 +/- A 6.6 ng/mL, P = 0.04), and all patients had vitamin D insufficiency (< 20 ng/mL) compared to 40% of controls (P = 0.01). All other biochemical parameters were within normal range and alike in both groups. BMAD in femoral neck and total femur was correlated with 25OHD levels in JoSSc (r = 0.82, P = 0.004; r = 0.707, P = 0.02; respectively). We have identified a remarkable high prevalence of 25OHD insufficiency in JoSSc. Its correlation with hip BMAD suggests a causal effect and reinforces the need to incorporate this hormone evaluation in this disease management.
Resumo:
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
Resumo:
OBJECTIVE To examine cortical thickness and volumetric changes in the cortex of patients with polymicrogyria, using an automated image analysis algorithm. METHODS Cortical thickness of patients with polymicrogyria was measured using magnetic resonance imaging (MRI) cortical surface-based analysis and compared with age-and sex-matched healthy subjects. We studied 3 patients with disorder of cortical development (DCD), classified as polymicrogyria, and 15 controls. Two experienced neuroradiologists performed a conventional visual assessment of the MRIs. The same data were analyzed using an automated algorithm for tissue segmentation and classification. Group and individual average maps of cortical thickness differences were produced by cortical surface-based statistical analysis. RESULTS Patients with polymicrogyria showed increased thickness of the cortex in the same areas identified as abnormal by radiologists. We also identified a reduction in the volume and thickness of cortex within additional areas of apparently normal cortex relative to controls. CONCLUSIONS Our findings indicate that there may be regions of reduced cortical thickness, which appear normal from radiological analysis, in the cortex of patients with polymicrogyria. This finding suggests that alterations in neuronal migration may have an impact in the cortical formation of the cortical areas that are visually normal. These areas are associated or occur concurrently with polymicrogyria.
Resumo:
Background and purpose: Tinnitus is a frequent disorder which is very difficult to treat and there is compelling evidence that tinnitus is associated with functional alterations in the central nervous system. Targeted modulation of tinnitus-related cortical activity has been proposed as a promising new treatment approach. We aimed to investigate both immediate and long-term effects of low frequency (1 Hz) repetitive transcranial magnetic stimulation (rTMS) in patients with tinnitus and normal hearing. Methods: Using a parallel design, 20 patients were randomized to receive either active or placebo stimulation over the left temporoparietal cortex for five consecutive days. Treatment results were assessed by using the Tinnitus Handicap Inventory. Ethyl cysteinate dimmer-single photon emission computed tomography (SPECT) imaging was performed before and 14 days after rTMS. Results: After active rTMS there was significant improvement of the tinnitus score as compared to sham rTMS for up to 6 months after stimulation. SPECT measurements demonstrated a reduction of metabolic activity in the inferior left temporal lobe after active rTMS. Conclusion: These results support the potential of rTMS as a new therapeutic tool for the treatment of chronic tinnitus, by demonstrating a significant reduction of tinnitus complaints over a period of at least 6 months and significant reduction of neural activity in the inferior temporal cortex, despite the stimulation applied on the superior temporal cortex.
Resumo:
The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.
Resumo:
This study was designed to investigate the feasibility of applying tone-ABRs in the nursery and neonatal intensive care unit (NICU), and to provide normative tone-ABR data from neonates. Normative tone-ABR latency data were determined. The study obtained intensity series of tone-ABRs from thirty preterm neonates and twenty fullterm neonates who had confirmed normal peripheral auditory function after passing both an OAE and ABR screening examination. ABRs were collected in response to 500, 1500, and 4000 Hz tone bursts at 70, 50, 30, and 20 dB nHL. Mean wave V latencies were compared between groups, ears, and by gender. Responses to tone bursts of 20 and 30 dB nHL were detected in 97% and 100% of all ears respectively, in addition to responses to the higher-intensity stimuli. Preterm neonates` ABRs showed significantly longer latencies than those of the full-term infants. Tone-ABR evaluation was found to be both feasible and reliable as a measure of auditory function in neonates.
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
Objective: To clarify whether the metabolism of triglyceride-rich lipoproteins and lipid transfer to high-density lipoprotein (HDL) are altered in patients with polycystic ovary syndrome (PCOS). Design: Case control study. Setting: Endocrinology clinics. Patient(s): Eight normal-weight (NW) and 15 obese (013) patients with PCOS were compared with 10 NW and 10 Ob women without PCOS paired for age and body mass index. Intervention(s): Determination of triglyceride-rich lipoprotein metabolism and lipid transfer to HDL. Main Outcome Measure(s): Participants were injected triglyceride-rich emulsions labeled with (14)C-cholesteryl esters and (3)H-triglycerides and the fractional clearance rate (FCR, in min(-1)) of labels was determined. Lipid transfer from artificial nanoemulsions to HDL was performed by incubating radioactively labeled lipid nanoemulsions with plasma during 1 hour, followed by radioactive counting of HDL-containing supernatant after chemical precipitation. Result(s): Lipolysis estimated by triglyceride FCR was equal in PCOS groups (NW = 0.043 +/- 0.032, Ob = 0.033 +/- 0.009) and respective controls (NW = 0.039 +/- 0.015, Ob = 0.044 +/- 0.019). However, the remnant removal as estimated by cholesteryl ester FCR was reduced in both PCOS groups (NW = 0.005 +/- 0.006, Ob = 0.005 +/- 0.005) compared with controls (NW = 0.016 +/- 0.006, Ob = 0.011 +/- 0.072). Lipid transfer rates were not different among groups, but triglyceride transfer rates were positively correlated with homeostasis model assessment estimate of insulin resistance in PCOS. Conclusion(s): PCOS patients showed decreased removal of atherogenic remnants even when fasting glucose was <100 mg/dL. This reinforces the usefulness of the measures taken to prevent cardiovascular events in PCOS patients. (Fertil Steril (R) 2010;93:1948-56. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objective. The purpose of this study was to construct nomograms of placental volumes according to gestational age and estimated fetal weight. Methods. From March to November 2007, placental volumes were prospectively measured by ultrasonography in 295 normal pregnancies from 12 to 40 weeks` gestation and correlated with gestational age and estimated fetal weight. Inclusion criteria were healthy women, singleton pregnancies with normal fetal morphologic characteristics on ultrasonography, and confirmed gestational age by first-trimester ultrasonography. Results. The mean placental volume ranged from 83 cm(3) at 12 weeks to 427.7 cm(3) at 40 weeks. Linear regression yielded the following formula for the expected placental volumes (ePV) according to gestational age (GA): ePV` (cm(3)) = -64.68 + 12.31 x GA (r = 0.572; P < .001). Placental volumes also varied according to estimated fetal weight (EFW), and the following mathematical equation was also obtained by linear regression: ePV = 94.19 + 0.09 x EFW (r = 0.505; P < 0.001). Conclusions. Nomograms of placental volumes according to gestational age and estimated fetal weight were constructed, generating reference values.
Resumo:
This study evaluated the use of Raman spectroscopy to identify the spectral differences between normal (N), benign hyperplasia (BPH) and adenocarcinoma (CaP) in fragments of prostate biopsies in vitro with the aim of developing a spectral diagnostic model for tissue classification. A dispersive Raman spectrometer was used with 830 nm wavelength and 80 mW excitation. Following Raman data collection and tissue histopathology (48 fragments diagnosed as N, 43 as BPH and 14 as CaP), two diagnostic models were developed in order to extract diagnostic information: the first using PCA and Mahalanobis analysis techniques and the second one a simplified biochemical model based on spectral features of cholesterol, collagen, smooth muscle cell and adipocyte. Spectral differences between N, BPH and CaP tissues, were observed mainly in the Raman bands associated with proteins, lipids, nucleic and amino acids. The PCA diagnostic model showed a sensitivity and specificity of 100%, which indicates the ability of PCA and Mahalanobis distance techniques to classify tissue changes in vitro. Also, it was found that the relative amount of collagen decreased while the amount of cholesterol and adipocyte increased with severity of the disease. Smooth muscle cell increased in BPH tissue. These characteristics were used for diagnostic purposes.