33 resultados para Visual Tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A better understanding of a species` reproductive physiology can help conservation programs to manage primates in the wild and develop assisted reproductive technologies in captivity. We investigated whether measurements of fecal progestin and estrogen metabolites obtained by a radioimmunoassay could be used to monitor the ovarian cycle of Alouatta caraya. We also compared the occurrence of vaginal bleeding with the hormone profiles. We collected fecal samples from 3 adult and 1 subadult captive female over 5 mo and performed vaginal cytology for the adults. The interval between fecal progestin surges in the adult females was 19.11 +/- 2.14 d (n = 18 cycles). Fecal progestin concentrations remained at basal values for 9.83 +/- 2.21 d (n = 18) and rose to elevated values for 9.47 +/- 0.72 d (n = 19). The subadult female showed basal levels of fecal estrogen and progestin concentrations throughout the study, suggesting that our hormone measurements are valid to monitor the ovarian cycle. Bleeding periods coincided with basal levels of fecal estrogens and progestin at intervals of 19.8 +/- 0.9 d and lasted for 4.1 +/- 1.0 d. Although we obtained these data from only 3 individuals, the results indicate that this species likely has a menstrual-type ovarian cycle. These data provide the first endocrine profile for the Alouatta caraya ovarian cycle and are similar to results obtained for other howler species. This similarity is important for comparative studies of howlers, allowing for a better understanding of their reproductive physiology and contributing to a critical information base for managing Alouatta species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen`s kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. On the other hand, radiographic examination and laser fluorescence were less efficient when used alone.