95 resultados para Type of study


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Even though porphyria cutanea tarda is the most frequent type of porphyria, there are few studies about its cutaneous physiopathology. OBJECTIVE: To evaluate skin changes in porphyria cutanea tarda using light microscopy and direct immunofluorescence before and after treatment with chloroquine. To perform antigen immunomapping of bullae to study their level of cleavage. METHODS: Light microscopy and direct immunofluorescence of 28 patients are reported in three different phases: 23 patients with active porphyria before treatment (Phase A), 7 patients with clinical remission during treatment (Phase B), and 8 patients with biochemical remission (Phase C). Immunomapping was performed on 7 patients. RESULTS: In active porphyria, direct immunofluorescence showed homogenous and intense fluorescence on the inside and on the walls of blood vessels as well as in the dermal-epidermal junction. In clinical remission (Phase B) and biochemical remission (Phase C), the deposit of immunoglobulins was maintained, but the deposit of complement was reduced in most cases. Immunomapping revealed no standard cleavage plane. CONCLUSION: No correlation was observed between clinical response and immunoglobulin deposits. The reduction of complement favors the hypothesis that activation of the complement cascade represents an additional pathway that leads to endothelial damage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Duration of untreated psychosis (DUP) depends on several factors, including socio-demographic, socioeconomic, clinical and contextual circumstances, such as availability of mental health services. Living arrangements may also play a role, especially in low- and middle-income countries, where most people who develop psychosis live with their relatives. Methods: Population-based study of first-episode psychosis in Sao Paulo, Brazil. Participants were aged 18-64 years, lived in a defined geographic area of the city and had a first contact in life with mental health services due to a psychotic episode. Duration of untreated psychosis was defined as the period between onset of first psychotic symptom and first contact with health service due to psychosis. The median DUP was used to classify participants into short and long DUP. Psychopathology, social adjustment and psychiatric diagnoses were made with standardized assessments. Type of service sought and living arrangements were examined. Results: Two hundred participants were included (52% women, 61% non-affective psychoses). The median DUP was 4.1 weeks (inter-quartile range: 1.9-11.4), and was shorter for affective psychoses. Most participants had their first contact with psychiatric emergency services. Those who did not live with a relative (children older than 18 years, parents, partner) were more likely to present long DUP (OR: 2.63; 95%Cl: 0.98-7.04); p = 0.05). Conclusion: The DUP in Sao Paulo was shorter than expected. Living arrangements may play an important role in shortening the DUP in urban centres of low- and middle income countries that have a network of mental health services. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies that have investigated ascorbic acid (AA) concentrations in cord blood have pointed to significant associations with maternal blood AA concentrations. smoking, age, diet, type of delivery, duration of gestation, fetal distress and birth weight. The aim of the present study was to determine the relationship between cord blood AA concentrations in newborns and maternal characteristics. A total of 117 Brazilian healthy parturients were included in this cross-sectional study. The concentrations of AA in blood were determined by the HPLC method. Data concerning socio-economic, demographic, obstetric, nutritional and health characteristics of the parturients, including alcohol consumption and smoking habit, were assessed by a standardised questionnaire. A FFQ was used to investigate the intake of foods rich in vitamin C. Cord blood AA concentration was significantly correlated with per capita income (r 0.26; P=0.005), maternal blood AA concentration (r 0.48; P<0.001) and maternal vitamin C-rich food intake score (r 0.36; P<0.001). The linear regression model including maternal AA concentration, alcohol consumption, smoking, parity, vitamin C-rich food intake score and per capita income explained 31.13% of the variation in cord blood AA concentrations in newborns. We recommend further experimental studies to assess the effects of ethanol on placental AA uptake, and epidemiological cohort studies to evaluate in detail the influence of maternal alcohol consumption on cord blood AA concentrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Obesity is epidemic worldwide, and increases in cesarean delivery rates have occurred in parallel. Objective: This study aimed to determine whether cesarean delivery is a risk factor for obesity in adulthood in a birth cohort of Brazilian subjects. Design: We initiated a birth cohort study in Ribeirao Preto, southeastern Brazil, in 1978. A randomly selected sample of 2057 subjects from the original cohort was reassessed in 2002-2004. Type of delivery, birth weight, maternal smoking, and schooling were obtained after birth. The following data from subjects were collected at 23-25 y of age: body mass index (BMI; in kg/m(2)), physical activity, smoking, and income. Obesity was defined as a BMI >= 30. A Poisson multivariable model was performed to determine the association between cesarean delivery and BMI. Results: The obesity rate in adults born by cesarean delivery was 15.2% and in those born by vaginal delivery was 10.4% (P = 0.002). Adults born by cesarean delivery had an increased risk (prevalence ratio: 1.58; 95% CI: 1.23, 2.02) of obesity at adulthood after adjustments. Conclusion: We hypothesize that increasing rates of cesarean delivery may play a role in the obesity epidemic worldwide. Am J Clin Nutr 2011;93:1344-7.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. In a pilot study, the authors aimed to determine the success rate of dental implants placed in patients who were positive for human immunodeficiency virus (HIV) and were receiving different regimens of highly active anti-retroviral therapy (HAART). They considered patients` levels of cluster of differentiation (CD) 4(+) cells and viral load, and they attempted to verify whether patients with baseline biochemical signs of bone mineral density loss could experience osseointegration impairment. Materials and Methods. One of the authors, a dentist, placed dental implants in the posterior mandibles of 40 volunteers, divided into three groups: one composed of HIV-positive patients receiving protease inhibitor (PI)-based HAART; a second composed of HIV-positive patients receiving nonnucleoside reverse transcriptase inhibitor based HAART (without PI); and a control group composed of HIV-negative participants. The authors assessed pen-implant health six and 12 months after implant loading. They analyzed the success of the implants in relation to CD4(+) cell counts, viral load and baseline pyridinoline and deoxypyridinoline values. Results. The authors followed 59 implants for 12 months after loading. Higher baseline levels of pyridinoline and deoxypyridinoline found in HIV-positive participants did not interfere with osseointegration after 12 months of follow-up. Average pen-implant bone loss after 12 months was 0.49 millimeters in group 1, 0.47 mm in group 2, and 0.55 mm in the control group. Conclusions. The placement of dental implants in HIV-positive patients is a reasonable treatment option, regardless of CD4(+) cell count, viral load levels and type of antiretroviral therapy. Longer, follow-up periods are necessary to ascertain the predictability of the long-term success of dental implants in these patients. Clinical Implications. Limited published scientific evidence is available to guide clinicians in regard to possible increased risks associated with dental implant placement in HIV-positive patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims Claudins are integral transmembrane proteins of the tight junctions, critical for maintaining cell adhesion and polarity. Alterations in the expression of individual claudins have been detected in carcinomas and appear to correlate with tumour progression. Methods In this study, a panel of anti-claudin antibodies (anti-claudins 1, 2, 3, 4, 5 and 7) was employed to map claudin expression in 136 cases of oral squamous cell carcinoma (OSCC) organised in a tissue microarray. Results Claudins were expressed in a reticular pattern up to the prickle layer in normal mucosal epithelium. In OSCC, claudins were strongly present in well-differentiated tumours, they presented mild and low expression in moderately differentiated OSCC, and were negative in poorly differentiated OSCC; the absences of claudin 1 (p = 0.002) and claudin 4 (p<0.001) were associated with moderately/poorly differentiated tumours. Strong expression of claudin 4 was associated with decreased perineural infiltration (p = 0.024). Claudins 5 and 7 were mostly negative or weakly expressed in all cases studied. Expression of claudin 7 was associated with the early clinical stages of the disease, whereas loss of claudin 7 tended to be more frequent in advanced stages of OSCC (p = 0.054). Absence of claudin 7 was also associated with absent vascular infiltration (p = 0.045) and with presence of recurrence (p = 0.052). Conclusions Claudin expression patterns showed a strong correlation with histological type of OSCC; claudin expression was decreased in areas of invasion, and negative in poorly differentiated tumours. This pattern may be related to evolution and prognosis of these tumours, especially in the case of claudin 7, which seems to be associated with a poor prognosis in OSCC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The effects of interactions between cross-linking proanthocyanidins (PA) in polar solvents and type-I collagen of demineralized dentin were investigated. Methods: Three PA-rich extracts, two from grape seed (GSEP and GSES) and one from cocoa (COE), were dissolved (water, ethanol:water and acetone:water) and analyzed for their ability to increase the modulus of elasticity of demineralized dentin. Sound dentin beams (0.5 mm x 1.7 mm x 7 mm) were fully demineralized and divided into 12 groups according to the type of cross-linking agent and solvents used. Specimens were immersed in the respective solutions and tested at baseline, 10, 30, 60, 120 and 240 min. Results: The elastic modulus (EM) of dentin was significantly increased by the PA treatment regardless of time (p < 0.05 for all times). The extracts showed different solubility in different solvents. GSEP showed the highest increase in EM when diluted in distilled water and acetone at all exposure times. Both GSEs showed superior results when diluted in distilled water and after 4 h of treatment, while COE produced strongest enhancement when dissolved in ethanol:water. Conclusions: The results indicates that herbal extraction process and other pharmacognostic parameters have an important influence on extract solubility as well as constitution and, consequently, on the PA-dentin matrix interaction. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study assessed the influence of anesthetics on early complications after pharyngeal flap surgery. A 23-year retrospective chart review was carried out of all patients at the authors` institution who underwent superiorly based pharyngeal flap surgery. Variables analyzed were gender, age at the time of surgery, cleft type, anesthesia procedure used and complications in the early postoperative period. 2299 patients (50% male; 50% female) who underwent pharyngeal flap surgery between 1980 and 2003 were reviewed. The highest number of surgeries was performed in patients aged 11-20 years. There were 1042 patients with at least one type of complication. Of these, 39 required reoperation to control complications such as bleeding and airway obstruction. There were no records of death. Vomiting and pain were the most frequent postoperative complications (16% and 14% of patients, respectively). Lower complication rates were observed when anesthesia protocols included sevoflurane, propofol and opioids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The double system of support, in which the distal-extension removable partial denture adapts, causes inadequate stress around abutment teeth, increasing the possibility of unequal bone resorption. Several ways to reduce or more adequately distribute the stress between abutment teeth and residual ridges have been reported; however, there are no definitive answers to the problem. The purpose of this study was to analyze, by means of photoelasticity, the most favorable stress distribution using three retainers: T bar, rest, proximal plate, I bar (RPI), and circumferential with mesialized rest. Materials and Methods: Three photoelastic models were made simulating a Kennedy Class II inferior arch. Fifteen dentures with long saddles, five of each design, were adjusted to the photoelastic patterns and submitted first to uniformly distributed load, and then to a load localized on the last artificial tooth. The saddles were then shortened and the tests repeated. The quantitative and qualitative analyses of stress intensity were done manually and by photography, respectively. For intragroup analyses the Wilcoxon test for paired samples was used, while for intergroup analyses Friedman and Wilcoxon tests were used to better identify the differences (p < 0.05). Results: The RPI retainer, followed by the T bar, demonstrated the best distribution of load between teeth and residual ridge. The circumferential retainer caused greater concentration of stress between dental apexes. Stress distribution was influenced by the type of retainer, the length of the saddle, and the manner of load application. Conclusions: The long saddles and the uniformly distributed loads demonstrated better distribution of stress on support structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To assess the in situ color stability, surface and the tooth/restoration interface degradation of a silorane-based composite (P90, 3M ESPE) after accelerated artificial ageing (AAA), in comparison with other dimethacrylate monomer-based composites (Z250/Z350, 3M ESPE and Esthet-X, Dentsply). Methods: Class V cavities (25 mm(2) x 2 mmdeep) were prepared in 48 bovine incisors, which were randomly allocated into 4 groups of 12 specimens each, according to the type of restorative material used. After polishing, 10 specimens were submitted to initial color readings (Easyshade, Vita) and 2 to analysis by scanning electronic microscopy (SEM). Afterwards, the teeth were submitted to AAA for 384 h, which corresponds to 1 year of clinical use, after which new color readings and microscopic images were obtained. The values obtained for the color analysis were submitted to statistical analysis (1-way ANOVA, Tukey, p < 0.05). Results: With regard to color stability, it was verified that all the composites showed color alteration above the clinically acceptable levels (Delta E >= 3.3), and that the silorane-based composite showed higher Delta E (18.6), with a statistically significant difference in comparison with the other composites (p < 0.05). The SEM images showed small alterations for the dimethacrylate-based composites after AAA and extensive degradation for the silorane-based composite with a rupture at the interface between the matrix/particle. Conclusion: It may be concluded that the silorane-based composite underwent greater alteration with regard to color stability and greater surface and tooth/restoration interface degradation after AAA. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This retrospective study evaluated the epidemiology, treatment and complications of mandibular fracture associated, or not associated, with other facial fractures, when the influence of the surgeon`s skill and preference for ally rigid internal fixation (RIF) system devices was minimized. The files of 700 patients with facial trauma were available, and 126 files were chosen for review. Data were collected regarding gender, age, race, date of trauma, date of surgery, addictions, etiology, signs and symptoms, fracture area, complications, treatment performed, date of hospital discharge.. and medication. 126 patients suffered mandibular fractures associated, or not, with other maxillofacial fractures, and a total of 201 mandibular fractures were found. The incidence of mandibular fractures was more prevalent in males, in Caucasians and during the third decade of life. The most common site was the condyle, followed by the mandibular body. The therapy applied was effective in handling this type of fracture and the Success rates were comparable with other published data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To assess the impact of chronic disease and the number of diseases on the various aspects of health-related quality of life (HRQOL) among the elderly in Sao Paulo, Brazil. Methods. The SF-36 (R) Health Survey was used to assess the impact of the most prevalent chronic diseases on HRQOL. A cross-sectional and population-based study was carried out with two-stage stratified cluster sampling. Data were obtained from a multicenter health survey administered through household interviews in several municipalities in the state of Sao Paulo. The study evaluated seven diseases-arthritis, back-pain, depression/anxiety, diabetes, hypertension, osteoporosis, and stroke-and their effects on quality of life. Results. Among the 1958 elderly individuals (60 years of age or older), 13.6% reported not having any of the illnesses, whereas 45.7% presented three or more chronic conditions. The presence of any of the seven chronic illnesses studied had a significant effect on the scores Of nearly all the SF-36 (R) scales. HRQOL achieved lower scores when related to depression/anxiety, osteoporosis, and stroke. The higher the number of diseases, the greater the negative effect on the SF-36 (R) dimensions. The presence of three or more diseases significantly affected HRQOL in all areas. The bodily pain, general health, and vitality scales were the most affected by diseases. Conclusions. The study detected a high prevalence of chronic diseases among the elderly population and found that the degree of impact on HRQOL depends on the type of disease. The results highlight the importance of preventing and controlling chronic diseases in order to reduce the number of comorbidities and lessen their impact on HRQOL among the elderly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Liponucleosides may assist the anchoring of nucleic acid nitrogen bases into biological membranes for tailored nanobiotechnological applications. To this end precise knowledge about the biophysical and chemical details at the membrane surface is required. In this paper, we used Langmuir monolayers as simplified cell membrane models and studied the insertion of five lipidated nucleosides. These molecules varied in the type of the covalently attached lipid group, the nucleobase, and the number of hydrophobic moieties attached to the nucleoside. All five lipidated nucleosides were found to be surface-active and capable of forming stable monolayers. They could also be incorporated into dipalmitoylphosphatidylcholine (DPPC) monolayers, four of which induced expansion in the surface pressure isotherm and a decrease in the surface compression modulus of DPPC. In contrast, one nucleoside possessing three alkyl chain modifications formed very condensed monolayers and induced film condensation and an increase in the compression modulus for the DPPC monolayer, thus reflecting the importance of the ability of the nucleoside molecules to be arranged in a closely packed manner. The implications of these results lie on the possibility of tuning nucleic acid pairing by modifying structural characteristics of the liponucleosides. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This in vitro study evaluated the tensile bond strength of glass fiber posts (Reforpost - Angelus-Brazil) cemented to root dentin with a resin cement (RelyX ARC - 3M/ESPE) associated with two different adhesive systems (Adper Single Bond - 3M/ESPE and Adper Scotchbond Multi Purpose (MP) Plus - 3M/ESPE), using the pull-out test. Twenty single-rooted human teeth with standardized root canals were randomly assigned to 2 groups (n=10): G1- etching with 37% phosphoric acid gel (3M/ESPE) + Adper Single Bond + #1 post (Reforpost - Angelus) + four #1 accessory posts (Reforpin - Angelus) + resin cement; G2- etching with 37% phosphoric acid gel + Adper Scotchbond MP Plus + #1 post + four #1 accessory posts + resin cement. The specimens were stored in distilled water at 37°C for 7 days and submitted to the pull-out test in a universal testing machine (EMIC) at a crosshead speed of 0.5 mm/min. The mean values of bond strength (kgf) and standard deviation were: G1- 29.163 ± 7.123; G2- 37.752 ±13.054. Statistical analysis (Student's t-test; a=0.05 showed no statistically significant difference (p<0.05) between the groups. Adhesive bonding failures between resin cement and root canal dentin surface were observed in both groups, with non-polymerized resin cement in the apical portion of the post space when Single Bond was used (G1). The type of adhesive system employed on the fiber post cementation did not influence the pull-out bond strength.