32 resultados para Medical Assistance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pain reactivity may reflect underlying mechanisms of constitutional aspects of temperament. Aim: To examine whether the neonatal biobehavioral reactivity and recovery responses from pain and distress, as well as the gestational age, the illness severity and the amount of painful procedures undergone the Neonatal Intensive Care Unit (NICU) stay, predict temperament later in toddlerhood, in vulnerable children born preterm. Study design: Prospective-longitudinal study. Subjects: Twenty-six preterm and very low birth weight infants followed from birth to toddlerhood. Outcome measures: Illness severity was assessed with the Clinical Risk Index for Babies (CRIB) score. The medical charts were reviewed prospectively for obtaining the amount of pain exposure in NICU. For assessing the behavioral and cardiac reactivity and recovery from pain and distress, the neonates were evaluated during routine blood collection in the NICU in the first 10 days of life. Pain and distress reactivity and recovery was measured using the Neonatal Facial Coding System score, the duration of crying. and the magnitude of average heart rate. At toddlerhood, mothers answered the Early Childhood Behavior Questionnaire. Results: Higher biobehavioral reactivity to pain and distress predicted higher temperamental Negative Affect, above and beyond gestational age, illness severity and amount of pain exposure in NICU. However, we did not find a predictive relation between gestational age, CRIB score and number of painful procedures undergone NICU and toddler`s temperament. Conclusions: The findings highlight the relevance of the neonatal individual characteristics of reactivity for identifying more vulnerable infants for future problems in biobehavioral regulation. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.