32 resultados para Magneto hydro dynamik


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The leaves and twigs of Piper krukoffii, collected in the Carajas National Forest, north Brazil, yielded essential oils (2.0% and 0.8%), the main constituents of which were myristicin (40.3% and 26.7%), apiole (25.4% and 34.1%) and elemicin (2.8% and 3.0%). The antioxidant activities of the oils, methanol extract and its sub-fractions were evaluated. The DPPH EC(50) values varied from the ethyl acetate sub-fraction (73.4 +/- 3.7 mu g/mL) to the methanol extract (24.9 +/- 0.8 mu g/mL), and the ABTS TEAC values ranged in the same order from 265.7 to 349.2 mu Mol TE/g. These results indicated a significant antioxidant activity for the plant. The lignans (-)-kusunokin, yatein, (-)-hinokin and cubebin were identified in the methanol extract. The hydro-methanolic sub-fraction showed a high value for total phenol content (106.5 +/- 0.7 mg GAE/g), as well as (1)H NMR signals for sugar moieties. Crude extracts and sub-fractions were also able to inhibit beta-carotene bleaching, varying from 22.4 to 47.1%. The oils from the leaves and twigs showed strong larvicidal (21.4 and 3.6 mu g/mL) and fungicide (0.5 and 0.1 mu g/mL) activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Protein hydrolysates have been used as active principles in cosmetic products conferring different properties to the final formulations, which are mostly controlled by the peptide size and its amino acid sequence. In this work, capillary electrophoresis coupled to mass spectrometry analyses were carried out in order to investigate such characteristics of protein hydrolysates. Samples of different origins (milk, soy and rice) were obtained from a local company, and were analyzed without a previous preparation step. The background electrolyte (BGE) and sheath liquid compositions were optimized for each sample. The best BGE composition (860 mmol/L formic acid - pH 1.8 - in 70: 30 v/v water/methanol hydro-organic solvent) was chosen based on the overall peak resolution whereas the best sheath liquid was selected based on increased sensitivity and presented different compositions to each sample (10.9-217 mmol/L formic acid in 75: 25-25: 75 v/v water/methanol hydro-organic solvent). Most of the putative peptides in the hydrolysate samples under investigation presented molecular masses of 1000 Da or less. De novo sequencing was carried out for some of the analytes, revealing the hydrophobicity/polarity of the peptides. Hence, the technique has proved to be an advantageous tool for the quality control of industrial protein hydrolysates.