61 resultados para Laparoscopic segmentectomy
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
An outbreak of infections affecting 311 patients who had undergone different invasive procedures occurred in 2004 and 2005 in the city of Belem, in the northern region of Brazil. Sixty-seven isolates were studied; 58 were from patients who had undergone laparoscopic surgeries, 1 was from a patient with a postinjection abscess, and 8 were from patients who had undergone mesotherapy. All isolates were rapidly growing nonpigmented mycobacteria and presented a pattern by PCR-restriction enzyme analysis of the hsp65 gene with BstEII of bands of 235 and 210 bp and with HaeIII of bands of 200, 70, 60, and 50 bp, which is common to Mycobacterium abscessus type 2, Mycobacterium bolletii, and Mycobacterium massiliense. hsp65 and. rpoB gene sequencing of a subset of 20 isolates was used to discriminate between these three species. hsp65 and rpoB sequences chosen at random from 11 of the 58 isolates from surgical patients and the postinjection abscess isolate presented the highest degrees of similarity with the corresponding sequences of M. massiliense. In the same way, the eight mesotherapy isolates were identified as M. bolletii. Molecular typing by pulsed-field gel electrophoresis (PFGE) grouped all 58 surgical isolates, while the mesotherapy isolates presented three different PFGE patterns and the postinjection abscess isolate showed a unique PFGE pattern. In conclusion, molecular techniques for identification and typing were essential for the discrimination of two concomitant outbreaks and one case, the postinjection abscess, not related to either outbreak all of which were originally attributed to a single strain of M. abscessus.
Resumo:
Background: Minimally invasive techniques have been revolutionary and provide clinical evidence of decreased morbidity and comparable efficacy to traditional open surgery. Computer-assisted surgical devices have recently been approved for general surgical use. Aim: The aim of this study was to report the first known case of pancreatic resection with the use of a computer-assisted, or robotic, surgical device in Latin America. Patient and Methods: A 37-year-old female with a previous history of radical mastectomy for bilateral breast cancer due to a BRCA2 mutation presented with an acute pancreatitis episode. Radiologic investigation disclosed an intraductal pancreatic neoplasm located in the neck of the pancreas with atrophy of the body and tail. The main pancreatic duct was enlarged. The surgical decision was to perform a laparoscopic subtotal pancreatectomy, using the da Vinci (R) robotic system (Intuitive Surgical, Sunnyvale, CA). Five trocars were used. Pancreatic transection was achieved with vascular endoscopic stapler. The surgical specimen was removed without an additional incision. Results: Operative time was 240 minutes. Blood loss was minimal, and the patient did not receive a transfusion. The recovery was uneventful, and the patient was discharged on postoperative day 4. Conclusions: The subtotal laparoscopic pancreatic resection can safely be performed. The da Vinci robotic system allowed for technical refinements of laparoscopic pancreatic resection. Robotic assistance improved the dissection and control of major blood vessels due to three-dimensional visualization of the operative field and instruments with wrist-type end-effectors.
Resumo:
Transanal endorectal pull-through (TAEPT) surgery is primarily performed for rectosigmoid aganglionosis, generally with excellent results. There is evidence that overstretching the anus and tension traction in the sigmoid during the procedure could impair the final continence of the patient. Many researchers suggest the use of small umbilical or laparoscopic access to aid in colon mobilization, thus preventing excessive handling within the anal canal. We assumed that transabdominal mobilization of the sigmoid could be prevented by utilizing the NOTES (natural orifices transluminal endoscopic surgery) technique. We performed a TAEPT with NOTES access of the sigmoid vascular pedicle, keeping the surgery exclusively transanal, which prevented scars in the abdomen and minimized the stretching of perineal structures.
Resumo:
Background and Purpose: Carbon dioxide pneumoperitoneum is associated with significant hypercarbia and acidosis. The aim of this study is to evaluate the effects of carbon dioxide and helium pneumoperitoneum on renal function. Materials and Methods: Thirty adult dogs were put randomly into one of three groups ( n = 10 animals each): group A - pneumoperitoneum not performed; group B - CO2 pneumoperitoneum; and group C - helium pneumoperitoneum. The groups were analyzed with consideration given to body weight, hematologic values, hemodynamic parameters ( heart rate, mean arterial pressure, central venous pressure, cardiac output, stroke volume, systemic vascular resistance, pulmonary vascular resistance, left cardiac work index, cardiac index, mean pulmonary artery pressure, and pulmonary capillary wedge pressure), and renal function ( plasma renin activity, urinary output, creatinine clearance, and sodium excretory fraction). Results: An accentuated decrease in urinary output was observed during pneumoperitoneum in groups B and C compared to the control group. In groups B and C, creatinine clearance declined significantly during pneumoperitoneum in comparison to group A, but after deflation a faster recovery of glomerular filtration was noticed for group C, and a significant increase in sodium excretory fraction was seen for group B. On the other hand, in comparison to the control group, group B had a significant increase in plasma renin activity, with late recovery of glomerular function. Conclusion: Helium ameliorates renal alterations when used for pneumoperitoneum, and it might be used for patients with compromised renal function who have to undergo laparoscopic surgery.
Resumo:
Background and Purpose: The right kidney has been less frequently used in live donor nephrectomy, because of the shorter length of the right renal vein (RRV) that is associated with technical difficulties and higher rates of venous thrombosis. In live open donor or deceased donor transplant nephrectomy, an additional cuff of the inferior vena cava is usually removed, but this is a more difficult and risky maneuver in laparoscopic nephrectomy. For this reason, laparoscopic right nephrectomy (LRN) for renal transplantation (RT) is not frequently performed in most medical institutions. We evaluate the difference between RRV and left renal vein (LRV) lengths in cadavers, as harvested for RT by three clamping methods. Our objective was to obtain information that could clarify when LRN for RT should be encouraged or avoided with regard to conventional surgery. Materials and Methods: Ninety adult fresh unfrozen cadavers were randomly divided into three groups of 30, according to the clamping device used: Satinsky, stapler, and Hem-o-lok clip. The abdominal viscera were removed through a median xyphopubic incision, and the veins were measured on the bench. Two lateral limits were used: The renal hilum and the tangential line of the renal poles. As for medial limits, the inferior vena cava or the laparoscopic clipping device on the RRV were used on the right side, while on the LRV, the medial border of the emergence of the adrenal vein was considered. After section of the renal vein, a slight traction of the extremity was applied for the measurement. All measurements were obtained three times using a metallic millimetric ruler, and the arithmetic mean was considered. The chi-square, one-way analysis of variance, and paired t tests were used for statistical analysis. Statistical significance was accepted at P <= 0.05. Results: The groups of cadavers were homogeneous in demographic characteristics. Regardless of the clamping method and considering the useful length of the LRV, the RRV was statistically smaller. The evaluation of the vein length did not depend on the lateral limit considered. Independent of the clamping method, on both sides, the lengths after the vein section were larger than before the section, a fact attributed to traction. Use of a stapler and a single Hem-o-lok presented the same waste of vein length on the right side. On average, the RRV was 13.7% shorter than the LRV. Conclusions: With the wide acceptance of laparoscopic live donor nephrectomy, the length difference between the veins of both kidneys is an important issue, and the right kidney is therefore used less than the left, compared with conventional surgery. This article represents the first step to quantify the anatomic length of renal veins in different situations. Certainly, more imagenologic or surgical studies should be carried out before decisions can be made for better selection of patients for LRN.
Resumo:
Background: We aimed to compare plasma concentrations of carbon dioxide (CO(2)) in dogs that underwent intra- and preperitoneal CO(2) insufflation. Materials and Methods: Thirty dogs were studied. Ten formed a control group, 10 underwent intraperitoneal CO(2) insufflation, and 10 underwent preperitoneal CO(2) insufflation. General anesthesia with controlled ventilation was standardized for all dogs. After stabilizing the anesthesia, blood samples were collected at predetermined times and were sent for immediate gasometric analysis. Analysis of variance was used for comparing variables. Results: The plasma CO(2) concentration in the intraperitoneal insufflation group increased significantly more than in the preperitoneal insufflation group and was significantly greater than in the control group (P < 0.05). The pH values in the intraperitoneal group were lower than in the preperitoneal group (P < 0.05). Conclusion: The data from this study suggest that a greater plasma concentration of CO(2) is achieved by insufflation at constant pressure into the intraperitoneal space than into the preperitoneal space.
Resumo:
Introduction: Treatment of severe bacterial peritonitis, especially by videolaparoscopy, is still a matter of investigation. The aim of the present study was to evaluate the effect of videolaparoscopy and laparotomy access with or without antibiotics on the outcome of severe bacterial peritonitis in rats. Materials and Methods: Sixty-four male Wistar rats were equally assigned to 8 groups: Sham surgery (SHAM), SHAM+antibiotics (SHAM+AB), cecal ligation and puncture (CLP), CLP+AB, CLP+videolaparoscopy (VLAP), CLP+laparotomy (LAP), VLAP+AB, and LAP+AB. All treated animals were submitted to an evaluation of bacteremia, white cell counts, and cytokine determinations: interleukin (IL)-1, IL-6, and tumor necrosis factor-alpha (TNF-alpha). The groups treated with antibiotics received gentamicin and metronidazole. Survival was monitored over a period of 7 days. Results: Peritonitis induced by CLP was severe, with IL-1, IL-6, and TNF-alpha levels and lethality being significantly higher compared to the SHAM group. The IL-6 levels in the VLAP group were significantly higher compared to the CLP and VLAP+AB groups, and the TNF-alpha levels in the VLAP and LAP+AB groups were significantly higher compared to the LAP group. The survival time was significantly higher in the CLP+AB and VLAP+AB groups, when compared to the CLP group. There was no significant difference in bacteremia and lethality rates between the resources employed for treatment of peritonitis. Conclusions: Although the use of laparoscopic access itself exacerbates the inflammatory response, the combination with antibiotics minimizes this effect and increases the survival time. However, all of the resources used for treating severe peritonitis, when applied alone or in combination, have an equivalent influence on bacteremia and lethality rates.
Resumo:
Purpose: This study was designed to compare the effectiveness of two methods of inducing renal hypothermia through laparoscopy in pigs and humans. Materials and Methods: Twelve pigs were divided into four groups of three animals each. Both kidneys of the animals in Groups A, B, and C were submitted to pelvic irrigation with cold saline (4 degrees C) for 20 minutes, with flow rates of 5 mL/min, 10 mL/min, and 15 mL/min, respectively. In Group D renal hypothermia was induced by intracorporeal ice slush applied to the surface for 20 minutes. All maneuvers were performed laparoscopically and renal cortex temperature was measured by a thermocouple needle. Five human patients also underwent laparoscopic partial nephrectomy due to renal cell carcinoma. In one case renoprotection was induced by retrograde endoscopic cold saline perfusion at a flow rate of 10 mL/min. In the remaining four patients we induced renal hypothermia via laparoscopic application of ice slush. The renal temperature of the human patients was also monitored using a thermocouple needle. Results: In the pigs, at 20 minutes of renal pelvis perfusion the mean renal temperature, the temperature drop, and saline flow per gram of kidney were: Group A, -29.5 degrees C +/- 1.1 (-6.3 degrees C; 0.10 mL); Group B, -22.8 degrees C +/- 1.1 (-13.1 degrees C; 0.22 mL); and Group C, -21.1 degrees C +/- 0.9 (-14.9 degrees C; 0.31 mL). In Group D the mean renal cortex temperature at 20 minutes was 13.6 degrees C +/- 1.2, a drop of -22.5 degrees C. There were striking differences among the groups (P < 0.0001). The laparoscopic partial nephrectomy was uneventful in all five human patients. The lowest renal cortex temperature was 32.5 degrees C, seen in the patient who submitted to pelvic irrigation with cold saline, and the mean temperature drop was 19.1 degrees C +/- 2.5 degrees C in the patients who submitted to ice slush-induced renal hypothermia. Conclusions: Induction of renal hypothermia using intracorporeal ice slush confers lower kidney temperatures than endoscopically-induced cold saline perfusion.
Resumo:
The realization of conventional surgical procedures, even using the recommended doses of analgesics drugs, generally are associated with a long recovery period, post-surgical trauma, stress and pain in animals. That can vary according with the procedure, extension and time of the surgery. Considering the increased interest in procedures that minimize surgical stress and the recovery period after the surgical procedure in dogs, this present work was developed to evaluate a new technique of laparoscopic colopexy with the alterations of cortisol levels, heart rate and respiratory frequencies in dogs. For this study, nine female dogs were submitted to a colopexy. Blood samples and data of heart rate and respiratory frequency were sampled in intervals of 10min. from the preoperative period until the end of the procedure. After, these parameters were assessed every three hours for 12 hours. Cortisol levels were measured using an ELISA Kit for cortisol. Results were analyzed by ANOVA and comparisons were made using Tukey's test. Significance levels was set at p <= 0.05. The increase of the heart rate, respiratory frequency and cortisol levels were mainly observed in the period after shaving and after the end of the anesthesia. Values were kept stable during all the surgery, and coming to the basal conditions after nine hours in the post-operative period. The laparoscopic colopexy is a stress-associated surgery, but it produces lower increasing of cortisol levels returning to normal in 9 hours after the surgery.
Resumo:
Background: One of the complications of laparoscopic adjustable gastric banding is intragastric erosion, leading to a revisional procedure to remove the band. Our aim was to present the procedure and results of endoscopic band removal in a 5-year multicenter experience from the Gastro Obeso Center and Universidade de Sao Paulo, Sao Paulo, and Universidade Federal de Pernambuco, Recite, Brazil. Methods: From 2003 to 2008, 82 patients were diagnosed with band erosion. The clinical data concerning the endoscopic procedure were prospectively recorded and retrospectively reviewed. Results: The average preoperative body mass index was 43.2 kg/m(2) (range 34-50). At the diagnosis of intragastric erosion, the body mass index was 24-41 kg/m(2) (average 31.8). The erosion occurred an average of 16.3 months (range 6-36) postoperatively. The symptoms included pain in 25 (31%), port infection in 21 patients (27%), and weight regain in 20 (25%), and 12 patients (15%) were asymptomatic. Endoscopic removal was possible for 78 patients (95%). In 85% of patients, the band was removed in the first session, with an average duration of 55 minutes (range 25-150). Five cases of pneumoperitoneum occurred after the procedure. Of these, 3 were treated conservatively, 1 was treated by laparoscopy, and I was treated by abdominal puncture using the Veress needle. Conclusion: Endoscopic removal of eroded laparoscopic adjustable gastric banding is safe and effective. It can be used as a first choice procedure in clinical practice. (Surg Obes Relat Dis 2010; 6:423-428.) (C) 2010 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Resumo:
Bariatric surgery in morbidly obese type 2 diabetic (T2DM) patients is associated with high rates of diabetes remission. We investigated the mechanisms of the anti-diabetic effect of the laparoscopic ileal interposition with sleeve gastrectomy (LII-SG) in normal weight (NW), overweight (OW) and obese (OB) T2DM patients. Ninety-four patients (aged 54 +/- 8 years) with long-standing (median 10 years), treated diabetes (median HbA(1c) = 8.6%), who were NW (15), OW (64) or OB (15) based on BMI, underwent LII-SG. Insulin sensitivity and parameters of -cell function were measured from an Oral Glycaemic Tolerance Test pre- and post-operatively. At a median of 13.4 months post-operatively, weight loss averaged 9.4 +/- 1.3, 16.8 +/- 0.8 and 23.2 +/- 1.7 kg in NW, OW and OB subjects, respectively (p < 0.0001). Insulin sensitivity was fully restored (395 [108] vs 208 [99] ml min(-1) m(-2)), fasting insulin secretion rate decreased (68 [52] vs 146 [120] pmol min(-1) m(-2)) and total insulin output increased (52 [26] vs 39 [28] nmol m(-2), all p a parts per thousand currency signaEuro parts per thousand 0.001). -cell glucose sensitivity doubled (37 [33] vs 18 [24] mol min(-1) m(-2) mM(-1), p < 0.0001). The only parameter predicting remission of diabetes was a lower baseline insulin sensitivity (p = 0.005). LII-SG induced changes on T2DM by mechanisms in part distinct from weight loss, principally involving restoration of insulin sensitivity and improvement of -cell function.
Resumo:
Preoperative progressive pneumoperitoneum (PPP) is a safe and effective procedure in the treatment of large incisional hernia (size > 10 cm in width or length) with loss of domain (LIHLD). There is no consensus in the literature on the amount of gas that must be insufflated in a PPP program or even how long it should be maintained. We describe a technique for calculating the hernia sac volume (HSV) and abdominal cavity volume (ACV) based on abdominal computerized tomography (ACT) scanning that eliminates the need for subjective criteria for inclusion in a PPP program and shows the amount of gas that must be insufflated into the abdominal cavity in the PPP program. Our technique is indicated for all patients with large or recurrent incisional hernias evaluated by a senior surgeon with suspected LIHLD. We reviewed our experience from 2001 to 2008 of 23 consecutive hernia surgical procedures of LIHLD undergoing preoperative evaluation with CT scanning and PPP. An ACT was required in all patients with suspected LIHLD in order to determine HSV and ACV. The PPP was performed only if the volume ratio HSV/ACV (VR = HSV/ACV) was a parts per thousand yen25% (VR a parts per thousand yen 25%). We have performed this procedure on 23 patients, with a mean age of 55.6 years (range 31-83). There were 16 women and 7 men with an average age of 55.6 years (range 31-83), and a mean BMI of 38.5 kg/m(2) (range 23-55.2). Almost all patients (21 of 23 patients-91.30%) were overweight; 43.5% (10 patients) were severely obese (obese class III). The mean calculated volumes for ACV and HSV were 9,410 ml (range 6,060-19,230 ml) and 4,500 ml (range 1,850-6,600 ml), respectively. The PPP is performed by permanent catheter placed in a minor surgical procedure. The total amount of CO(2) insufflated ranged from 2,000 to 7,000 ml (mean 4,000 ml). Patients required a mean of 10 PPP sessions (range 4-18) to achieve the desired volume of gas (that is the same volume that was calculated for the hernia sac). Since PPP sessions were performed once a day, 4-18 days were needed for preoperative preparation with PPP. The mean VR was 36% (ranged from 26 to 73%). We conclude that ACT provides objective data for volume calculation of both hernia sac and abdominal cavity and also for estimation of the volume of gas that should be insufflated into the abdominal cavity in PPP.
Resumo:
Introduction: Laparoscopic nephrectomy in children has become a reasonable alternative to open nephrectomy and has replaced open surgery for many renal diseases. The purpose of our study is to evaluate transperitoneal videolaparoscopic procedures in renal benign diseases in comparison to an open surgery approach. Patients and methods: 34 children aged between 17 days and 15 years old (mean 6.14) were divided into two groups in order to be submitted to nephrectomy. The first one underwent transperitoneal videolaparoscopic nephrectomy and was composed by 21 patients aged from 2 months to 15 years (mean 7.42), from which 12 were females and 9 males. The second group was submitted to open nephrectomy and was composed by 13 patients aged from 17 days to 11 years (mean 3.91), 6 females and 7 males. The groups were compared regarding anesthesic time, operative time, length of hospital stay, postoperative pain and time of reintroduction of oral intake. Short and long term complications were also evaluated. Statistical analysis was performed by Student t-test with the level of significance set at P < 0.05. The study was previously approved by the Committee on Ethics in Research of our institution. Results: Significant statistical difference was observed only for the variable length of hospital stay. No laparoscopy group case was converted to open surgery. There was no immediate or late complication. Blood loss was negligible and no transfusion was required. Conclusions: In our experience, transperitoneal videolaparoscopic nephrectomy has similar results to open nephrectomy, except for time of hospitalization. (C) 2009 AEU. Published by Elsevier Espana, S.L. All rights reserved.
Resumo:
Background: The high missed occult small bowel injuries (SBI) associated with laparoscopy in trauma (LIT) is a major reason why some surgeons still preclude LIT today. No standardized laparoscopic examination for evaluation of the peritoneal cavity is described for trauma. The objective of this article is to verify if a systematic standardized laparoscopic approach could correctly identify SBI in the peritoneal cavity for penetrating abdominal trauma (PAT). Methods: Victims with PAT were evaluated in a prospective, nonrandomized study. A total of 75 hemodynamically stable patients with suspected abdominal injuries were operated by LIT and converted to laparotomy if criteria were met: SBI and lesions to blind spot zones-retroperitoneal hematoma, injuries to segments VI or VII of the liver, or injuries to the posterior area of the spleen. Inclusion criteria were equivocal evidence of abdominal injuries or peritonea] penetration; systolic blood pressure >90 mm Hg and <3 L of IV fluids in the first hour of admission; Glasgow Coma Scale score >12; and age >12 years. Exclusion criteria were back injuries; pregnancy; previous laparotomy; and chronic cardiorespiratory disease. Results: Sixty patients were males and there were 38 stab wounds and 37 gunshot wounds. No SBI was missed, but a pancreatic lesion was undiagnosed due to a retroperitoneal hematoma. Twenty patients (26.6%) were converted. Unnecessary laparotomies were avoided in 73.33%. Therapeutic LIT was possible in 22.7%. Accuracy was 98.66% with 97.61% sensitivity and 100% specificity. Conclusions: Standard systematic laparoscopic exploration was 100% effective to detect SBI in the peritoneal cavity. Conversion from LIT to laparotomy should be done if injuries to blind spot zones are found which are poorly evaluated by LIT. Therapeutic LIT is feasible in PAT.