64 resultados para LAPAROSCOPIC CHOLECYSTECTOMY
Resumo:
Bisegmentectomy 7-8 is feasible even in the absence of a large inferior right hepatic vein. To our knowledge, this operation has never been performed by laparoscopy. This study was designed to present video of pure laparoscopic bisegmentectomy 7-8 and bisegmentectomy 2-3 in one-stage operation for bilateral liver metastasis. A 67-year-old man with metachronous bilobar colorectal liver metastasis was referred for surgical treatment after neoadjuvant chemotherapy. CT scan disclosed two liver metastases: one located between segments 7 and 8 and another one in segment 2. At liver examination, another metastasis was found on segment 3. We decided to perform a bisegmentectomy 7-8 along with bisegmentectomy 2-3 in a single procedure. The operation began with mobilization of the right liver with complete dissection of retrohepatic vena cava. Inferior right hepatic vein was absent. Right hepatic vein was dissected and encircled. Upper part of right liver, containing segment 7 and 8, was marked with cautery. Selective hemi-Pringle maneuver was performed and right hepatic vein was divided with stapler. At this point, liver rotation to the left allowed direct view and access to the superior aspect of the right liver. Liver transection was accomplished with harmonic scalpel and endoscopic stapling device. Bisegmentectomy 2-3 was performed using the intrahepatic Glissonian approach. The specimens were extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 240 minutes with no need for transfusion. Recovery was uneventful. Patient was discharged on the fifth postoperative day. Patient is well with no evidence of disease 14 months after liver resection. Tumor markers are within normal range. Bisegmentectomy 7-8 may increase resectability rate in patients with bilateral lesions. This operation can be performed safely by laparoscopy. Preservation of segments 5 and 6 permitted simultaneous resection of segments 2 and 3 with adequate liver remnant.
Resumo:
Experience with advanced techniques has increased the indications for laparoscopic liver resection. This video demonstrates technical aspects of a pure laparoscopic mesohepatectomy using intrahepatic Glissonian technique. To the best of our knowledge, this is the first case of anatomic laparoscopic mesohepatectomy using the Glissonian approach published in the English literature. A 62-year-old man with colorectal liver metastasis occupying central liver segments was referred for surgical treatment. The first step is the control of segment 4 pedicle. Using the round ligament as a guide, one incision is performed on its right margin and another is made at the bottom of segment 4. A vascular clamp is introduced through those incisions to occlude segment 4 Glissonian sheath. The next step is to control the right anterior pedicle. The first incision is made in front of the hilum and another is performed on the right edge of gallbladder bed. Laparoscopic clamp is introduced through these incisions and closed producing ischemic discoloration of segments 5 and 8. Vascular clamp is replaced by an endoscopic vascular stapling device and stapler is fired. Line of liver transection is marked along the liver surface following ischemic area. Liver transection is accomplished with bipolar vessel sealing device and endoscopic stapling device as appropriate. Specimen was extracted through a suprapubic incision. Liver raw surfaces were reviewed for bleeding and bile leaks. Operative time was 200 min with minimum blood loss and no need for blood transfusion. Recovery was uneventful, and the patient was discharged on the fifth postoperative day. Histological examination revealed clear surgical margins. Mesohepatectomy can be safely performed laparoscopically in selected patients and by surgeons with expertise in both liver surgery and laparoscopic techniques. The use of the intrahepatic Glissonian approach may help to identify the exact limits of the mesohepatectomy to avoid ischemic injury of the remnant liver.
Resumo:
Background: Widespread use of prostate-specific antigen screening has resulted in younger and healthier men being diagnosed with prostate cancer. Their demands and expectations of surgical intervention are much higher and cannot be adequately addressed with the classic trifecta outcome measures. Objective: A new and more comprehensive method for reporting outcomes after radical prostatectomy, the pentafecta, is proposed. Design, setting, and participants: From January 2008 through September 2009, details of 1111 consecutive patients who underwent robot-assisted radical prostatectomy performed by a single surgeon were retrospectively analyzed. Of 626 potent men, 332 who underwent bilateral nerve sparing and who had 1 yr of follow-up were included in the study group. Measurements: In addition to the traditional trifecta outcomes, two perioperative variables were included in the pentafecta: no postoperative complications and negative surgical margins. Patients who attained the trifecta and concurrently the two additional outcomes were considered as having achieved the pentafecta. A logistic regression model was created to evaluate independent factors for achieving the pentafecta. Results and limitations: Continence, potency, biochemical recurrence-free survival, and trifecta rates at 12 mo were 96.4%, 89.8%, 96.4%, and 83.1%, respectively. With regard to the perioperative outcomes, 93.4% had no postoperative complication and 90.7% had negative surgical margins. The pentafecta rate at 12 mo was 70.8%. On multivariable analysis, patient age (p = 0.001) was confirmed as the only factor independently associated with the pentafecta. Conclusions: A more comprehensive approach for reporting prostate surgery outcomes, the pentafecta, is being proposed. We believe that pentafecta outcomes more accurately represent patients` expectations after minimally invasive surgery for prostate cancer. This approach may be beneficial and may be used when counseling patients with clinically localized disease. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.
Resumo:
Background: Transcutaneous electrical nerve stimulation (TENS) is an effective adjunctive therapy for postoperative pain; however, effects of different frequencies Of stimulation have not been systematically investigated. Laparoscopic sterilization (LS) causes significant pain in the early postoperative period and requires substantial postoperative medication. Therefore, we studied the effects of TENS on postoperative pain after LS through placement of Yoon fallopian rings in a prospective, randomized, double-blinded, and placebo-controlled study. Methods: Sixty-four patients undergoing LS for uterine tube ligation were randomly allocated to receive either active TENS or placebo TENS. Postoperative pain was evaluated using a standard I I-point numeric rating scale and the McGill Pain Questionnaire (MPQ)-pain rating index and number of words chosen. Both high frequency (100 Hz) and low frequency (4 Hz) TENS, at strong, but comfortable sensory intensity, were applied for 20 minutes through 4 electrodes placed around the surgical incision immediately after Surgery. Pain was assessed before and after application of TENS when patients were at postanesthesia care unit (PACU). Results: Both high and low frequency TENS significantly decreased postoperative pain intensity when compared with before administration of TENS using the numeric rating scale (P = 0.001), pain rating index (P = 0.001), and number of words chosen (P 0.001) compared with placebo TENS (P = 0.001). TENS in combination with standard pharmacologic analgesic treatment was efficacious for postoperative pain relief after LS. Conclusions: We recommend regular use of multimodal therapy with TENS and analgesic drugs after LS with placement of Yoon rings.
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
An outbreak of infections affecting 311 patients who had undergone different invasive procedures occurred in 2004 and 2005 in the city of Belem, in the northern region of Brazil. Sixty-seven isolates were studied; 58 were from patients who had undergone laparoscopic surgeries, 1 was from a patient with a postinjection abscess, and 8 were from patients who had undergone mesotherapy. All isolates were rapidly growing nonpigmented mycobacteria and presented a pattern by PCR-restriction enzyme analysis of the hsp65 gene with BstEII of bands of 235 and 210 bp and with HaeIII of bands of 200, 70, 60, and 50 bp, which is common to Mycobacterium abscessus type 2, Mycobacterium bolletii, and Mycobacterium massiliense. hsp65 and. rpoB gene sequencing of a subset of 20 isolates was used to discriminate between these three species. hsp65 and rpoB sequences chosen at random from 11 of the 58 isolates from surgical patients and the postinjection abscess isolate presented the highest degrees of similarity with the corresponding sequences of M. massiliense. In the same way, the eight mesotherapy isolates were identified as M. bolletii. Molecular typing by pulsed-field gel electrophoresis (PFGE) grouped all 58 surgical isolates, while the mesotherapy isolates presented three different PFGE patterns and the postinjection abscess isolate showed a unique PFGE pattern. In conclusion, molecular techniques for identification and typing were essential for the discrimination of two concomitant outbreaks and one case, the postinjection abscess, not related to either outbreak all of which were originally attributed to a single strain of M. abscessus.
Resumo:
OBJECTIVES: Causes may be found in most cases of acute pancreatitis, however no etiology is found by clinical, biological and imaging investigations in 30% of these cases. Our objective was to evaluate results from endoscopic ultrasonography (EUS) for diagnosis of gallbladder microlithiasis in patients with unexplained (idiopathic) acute pancreatitis. METHODS: Thirty-six consecutive non-alcoholic patients with diagnoses of acute pancreatitis were studied over a five-year period. None of them showed signs of gallstones on transabdominal ultrasound or tomography. We performed EUS within one week of diagnosing acute pancreatitis. Diagnosis of gallbladder microlithiasis on EUS was based upon findings of hyperechoic signals of 0.5-3.0 mm, with or without acoustic shadowing. All patients (36 cases) underwent cholecystectomy, in accordance with indication from the attending physician or based upon EUS diagnosis. RESULTS: Twenty-seven patients (75%) had microlithiasis confirmed by histology and nine did not (25%). EUS findings were positive in twenty-five. Two patients had acute cholecystitis diagnosed at EUS that was confirmed by surgical and histological findings. In two patients, EUS showed cholesterolosis and pathological analysis disclosed stones not detected by EUS. EUS diagnosed microlithiasis in four cases not confirmed by surgical treatment. In our study, sensitivity, specificity and positive and negative predictive values to identify gallbladder microlithiasis (with 95% confidence interval) were 92.6% (74.2-98.7%), 55.6% (22.7-84.7%), 86.2% (67.4-95.5%) and 71.4% (30.3-94.9%), respectively. Overall EUS accuracy was 83.2%. CONCLUSIONS: EUS is a very reliable procedure to diagnose gallbladder microlithiasis and should be used for the management of patients with unexplained acute pancreatitis. This procedure should be part of advanced endoscopic evaluation.
Resumo:
Background: Minimally invasive techniques have been revolutionary and provide clinical evidence of decreased morbidity and comparable efficacy to traditional open surgery. Computer-assisted surgical devices have recently been approved for general surgical use. Aim: The aim of this study was to report the first known case of pancreatic resection with the use of a computer-assisted, or robotic, surgical device in Latin America. Patient and Methods: A 37-year-old female with a previous history of radical mastectomy for bilateral breast cancer due to a BRCA2 mutation presented with an acute pancreatitis episode. Radiologic investigation disclosed an intraductal pancreatic neoplasm located in the neck of the pancreas with atrophy of the body and tail. The main pancreatic duct was enlarged. The surgical decision was to perform a laparoscopic subtotal pancreatectomy, using the da Vinci (R) robotic system (Intuitive Surgical, Sunnyvale, CA). Five trocars were used. Pancreatic transection was achieved with vascular endoscopic stapler. The surgical specimen was removed without an additional incision. Results: Operative time was 240 minutes. Blood loss was minimal, and the patient did not receive a transfusion. The recovery was uneventful, and the patient was discharged on postoperative day 4. Conclusions: The subtotal laparoscopic pancreatic resection can safely be performed. The da Vinci robotic system allowed for technical refinements of laparoscopic pancreatic resection. Robotic assistance improved the dissection and control of major blood vessels due to three-dimensional visualization of the operative field and instruments with wrist-type end-effectors.
Resumo:
Transanal endorectal pull-through (TAEPT) surgery is primarily performed for rectosigmoid aganglionosis, generally with excellent results. There is evidence that overstretching the anus and tension traction in the sigmoid during the procedure could impair the final continence of the patient. Many researchers suggest the use of small umbilical or laparoscopic access to aid in colon mobilization, thus preventing excessive handling within the anal canal. We assumed that transabdominal mobilization of the sigmoid could be prevented by utilizing the NOTES (natural orifices transluminal endoscopic surgery) technique. We performed a TAEPT with NOTES access of the sigmoid vascular pedicle, keeping the surgery exclusively transanal, which prevented scars in the abdomen and minimized the stretching of perineal structures.
Resumo:
Background and Purpose: Carbon dioxide pneumoperitoneum is associated with significant hypercarbia and acidosis. The aim of this study is to evaluate the effects of carbon dioxide and helium pneumoperitoneum on renal function. Materials and Methods: Thirty adult dogs were put randomly into one of three groups ( n = 10 animals each): group A - pneumoperitoneum not performed; group B - CO2 pneumoperitoneum; and group C - helium pneumoperitoneum. The groups were analyzed with consideration given to body weight, hematologic values, hemodynamic parameters ( heart rate, mean arterial pressure, central venous pressure, cardiac output, stroke volume, systemic vascular resistance, pulmonary vascular resistance, left cardiac work index, cardiac index, mean pulmonary artery pressure, and pulmonary capillary wedge pressure), and renal function ( plasma renin activity, urinary output, creatinine clearance, and sodium excretory fraction). Results: An accentuated decrease in urinary output was observed during pneumoperitoneum in groups B and C compared to the control group. In groups B and C, creatinine clearance declined significantly during pneumoperitoneum in comparison to group A, but after deflation a faster recovery of glomerular filtration was noticed for group C, and a significant increase in sodium excretory fraction was seen for group B. On the other hand, in comparison to the control group, group B had a significant increase in plasma renin activity, with late recovery of glomerular function. Conclusion: Helium ameliorates renal alterations when used for pneumoperitoneum, and it might be used for patients with compromised renal function who have to undergo laparoscopic surgery.
Resumo:
Background and Purpose: The right kidney has been less frequently used in live donor nephrectomy, because of the shorter length of the right renal vein (RRV) that is associated with technical difficulties and higher rates of venous thrombosis. In live open donor or deceased donor transplant nephrectomy, an additional cuff of the inferior vena cava is usually removed, but this is a more difficult and risky maneuver in laparoscopic nephrectomy. For this reason, laparoscopic right nephrectomy (LRN) for renal transplantation (RT) is not frequently performed in most medical institutions. We evaluate the difference between RRV and left renal vein (LRV) lengths in cadavers, as harvested for RT by three clamping methods. Our objective was to obtain information that could clarify when LRN for RT should be encouraged or avoided with regard to conventional surgery. Materials and Methods: Ninety adult fresh unfrozen cadavers were randomly divided into three groups of 30, according to the clamping device used: Satinsky, stapler, and Hem-o-lok clip. The abdominal viscera were removed through a median xyphopubic incision, and the veins were measured on the bench. Two lateral limits were used: The renal hilum and the tangential line of the renal poles. As for medial limits, the inferior vena cava or the laparoscopic clipping device on the RRV were used on the right side, while on the LRV, the medial border of the emergence of the adrenal vein was considered. After section of the renal vein, a slight traction of the extremity was applied for the measurement. All measurements were obtained three times using a metallic millimetric ruler, and the arithmetic mean was considered. The chi-square, one-way analysis of variance, and paired t tests were used for statistical analysis. Statistical significance was accepted at P <= 0.05. Results: The groups of cadavers were homogeneous in demographic characteristics. Regardless of the clamping method and considering the useful length of the LRV, the RRV was statistically smaller. The evaluation of the vein length did not depend on the lateral limit considered. Independent of the clamping method, on both sides, the lengths after the vein section were larger than before the section, a fact attributed to traction. Use of a stapler and a single Hem-o-lok presented the same waste of vein length on the right side. On average, the RRV was 13.7% shorter than the LRV. Conclusions: With the wide acceptance of laparoscopic live donor nephrectomy, the length difference between the veins of both kidneys is an important issue, and the right kidney is therefore used less than the left, compared with conventional surgery. This article represents the first step to quantify the anatomic length of renal veins in different situations. Certainly, more imagenologic or surgical studies should be carried out before decisions can be made for better selection of patients for LRN.
Resumo:
Background: We aimed to compare plasma concentrations of carbon dioxide (CO(2)) in dogs that underwent intra- and preperitoneal CO(2) insufflation. Materials and Methods: Thirty dogs were studied. Ten formed a control group, 10 underwent intraperitoneal CO(2) insufflation, and 10 underwent preperitoneal CO(2) insufflation. General anesthesia with controlled ventilation was standardized for all dogs. After stabilizing the anesthesia, blood samples were collected at predetermined times and were sent for immediate gasometric analysis. Analysis of variance was used for comparing variables. Results: The plasma CO(2) concentration in the intraperitoneal insufflation group increased significantly more than in the preperitoneal insufflation group and was significantly greater than in the control group (P < 0.05). The pH values in the intraperitoneal group were lower than in the preperitoneal group (P < 0.05). Conclusion: The data from this study suggest that a greater plasma concentration of CO(2) is achieved by insufflation at constant pressure into the intraperitoneal space than into the preperitoneal space.
Resumo:
Introduction: Treatment of severe bacterial peritonitis, especially by videolaparoscopy, is still a matter of investigation. The aim of the present study was to evaluate the effect of videolaparoscopy and laparotomy access with or without antibiotics on the outcome of severe bacterial peritonitis in rats. Materials and Methods: Sixty-four male Wistar rats were equally assigned to 8 groups: Sham surgery (SHAM), SHAM+antibiotics (SHAM+AB), cecal ligation and puncture (CLP), CLP+AB, CLP+videolaparoscopy (VLAP), CLP+laparotomy (LAP), VLAP+AB, and LAP+AB. All treated animals were submitted to an evaluation of bacteremia, white cell counts, and cytokine determinations: interleukin (IL)-1, IL-6, and tumor necrosis factor-alpha (TNF-alpha). The groups treated with antibiotics received gentamicin and metronidazole. Survival was monitored over a period of 7 days. Results: Peritonitis induced by CLP was severe, with IL-1, IL-6, and TNF-alpha levels and lethality being significantly higher compared to the SHAM group. The IL-6 levels in the VLAP group were significantly higher compared to the CLP and VLAP+AB groups, and the TNF-alpha levels in the VLAP and LAP+AB groups were significantly higher compared to the LAP group. The survival time was significantly higher in the CLP+AB and VLAP+AB groups, when compared to the CLP group. There was no significant difference in bacteremia and lethality rates between the resources employed for treatment of peritonitis. Conclusions: Although the use of laparoscopic access itself exacerbates the inflammatory response, the combination with antibiotics minimizes this effect and increases the survival time. However, all of the resources used for treating severe peritonitis, when applied alone or in combination, have an equivalent influence on bacteremia and lethality rates.
Resumo:
Purpose: This study was designed to compare the effectiveness of two methods of inducing renal hypothermia through laparoscopy in pigs and humans. Materials and Methods: Twelve pigs were divided into four groups of three animals each. Both kidneys of the animals in Groups A, B, and C were submitted to pelvic irrigation with cold saline (4 degrees C) for 20 minutes, with flow rates of 5 mL/min, 10 mL/min, and 15 mL/min, respectively. In Group D renal hypothermia was induced by intracorporeal ice slush applied to the surface for 20 minutes. All maneuvers were performed laparoscopically and renal cortex temperature was measured by a thermocouple needle. Five human patients also underwent laparoscopic partial nephrectomy due to renal cell carcinoma. In one case renoprotection was induced by retrograde endoscopic cold saline perfusion at a flow rate of 10 mL/min. In the remaining four patients we induced renal hypothermia via laparoscopic application of ice slush. The renal temperature of the human patients was also monitored using a thermocouple needle. Results: In the pigs, at 20 minutes of renal pelvis perfusion the mean renal temperature, the temperature drop, and saline flow per gram of kidney were: Group A, -29.5 degrees C +/- 1.1 (-6.3 degrees C; 0.10 mL); Group B, -22.8 degrees C +/- 1.1 (-13.1 degrees C; 0.22 mL); and Group C, -21.1 degrees C +/- 0.9 (-14.9 degrees C; 0.31 mL). In Group D the mean renal cortex temperature at 20 minutes was 13.6 degrees C +/- 1.2, a drop of -22.5 degrees C. There were striking differences among the groups (P < 0.0001). The laparoscopic partial nephrectomy was uneventful in all five human patients. The lowest renal cortex temperature was 32.5 degrees C, seen in the patient who submitted to pelvic irrigation with cold saline, and the mean temperature drop was 19.1 degrees C +/- 2.5 degrees C in the patients who submitted to ice slush-induced renal hypothermia. Conclusions: Induction of renal hypothermia using intracorporeal ice slush confers lower kidney temperatures than endoscopically-induced cold saline perfusion.
Resumo:
The realization of conventional surgical procedures, even using the recommended doses of analgesics drugs, generally are associated with a long recovery period, post-surgical trauma, stress and pain in animals. That can vary according with the procedure, extension and time of the surgery. Considering the increased interest in procedures that minimize surgical stress and the recovery period after the surgical procedure in dogs, this present work was developed to evaluate a new technique of laparoscopic colopexy with the alterations of cortisol levels, heart rate and respiratory frequencies in dogs. For this study, nine female dogs were submitted to a colopexy. Blood samples and data of heart rate and respiratory frequency were sampled in intervals of 10min. from the preoperative period until the end of the procedure. After, these parameters were assessed every three hours for 12 hours. Cortisol levels were measured using an ELISA Kit for cortisol. Results were analyzed by ANOVA and comparisons were made using Tukey's test. Significance levels was set at p <= 0.05. The increase of the heart rate, respiratory frequency and cortisol levels were mainly observed in the period after shaving and after the end of the anesthesia. Values were kept stable during all the surgery, and coming to the basal conditions after nine hours in the post-operative period. The laparoscopic colopexy is a stress-associated surgery, but it produces lower increasing of cortisol levels returning to normal in 9 hours after the surgery.