157 resultados para LAMBDA-0 HYPERON POLARIZATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess oral health status and its relationship with quality of life. A household population, cross-sectional study was carried out; participants were between 15 and 17 years of age (n = 247) and were examined by two calibrated dentists. Socio-economic status was classified according to ANEP-ABIPEME criteria. Clinical examinations to observe DMFT, CPI and Dean indices were performed as per WHO criteria. The Significant Caries Index (SiC) was used to evaluate polarization of the occurrence of caries among participants of the tercile with higher DMF-T. The OHIP instrument was used to measure quality of life. The Spearman and Mann-Whitney tests were used for assessing correlations (5% significance level). Examinations were carried out in 117 (47.37%) females and in 130 (52.63%) males. Of the examined participants, 45.75% were classified as belonging to socio-economic class C. Caries occurrence was observed in 218 subjects (88.26%); the mean DMFT was 5.40. The SiC index was 9.97. Almost half (47.77%) of the participants examined did not present sextants affected by periodontal disease. Of the participants examined, 80.16% presented absence of fluorosis. The mean OHIP was 3.95. The following correlations were observed: a positive and statistically significant correlation between the highest score in the OHIP and decayed teeth; a positive correlation with threshold significance between OHIP and DMFT; an inverse correlation between intact teeth and OHIP; and a positive and non statistically significant correlation between SiC and OHIP (correlation coefficient = 0.13, p = 0.245). Association between the mean OHIP and the terciles was not significant (p = 0.146); there were also no associations between periodontal condition and OHIP nor were there associations between the presence of fluorosis and mean OHIP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Er:YAG laser has been studied as a potential tool for restorative dentistry due to its ability to selectively remove oral hard tissue with minimal or no thermal damage to the surrounding tissues. The purpose of this study was to evaluate in vitro the tensile bond strength (TBS) of an adhesive/composite resin system to human enamel surfaces treated with 37% phosphoric acid, Er:YAG laser (lambda=2.94 mum) with a total energy of 16 J (80 mJ/pulse, 2Hz, 200 pulses, 250 ms pulse width), and Er:YAG laser followed by phosphoric acid etching. Analysis of the treated surfaces was performed by scanning electron microscopy (SEM) to assess morphological differences among the groups. TBS means (in MPa) were as follows: Er:YAG laser + acid (11.7 MPa) > acid (8.2 MPa) > Er:YAG laser (6.1 MPa), with the group treated with laser+acid being significantly from the other groups (p=0.0006 and p= 0.00019, respectively). The groups treated with acid alone and laser alone were significantly different from each other (p=0.0003). The SEM analysis revealed morphological changes that corroborate the TBS results, suggesting that the differences in TBS means among the groups are related to the different etching patterns produced by each type of surface treatment. The findings of this study indicate that the association between Er:YAG laser and phosphoric acid can be used as a valuable resource to increase bond strength to laser-prepared enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of an exercise on electrochemistry for General Chemistry students are presented. The difficulty encountered by students in predicting the shift in the potential of the hydrogen electrode under non-standard conditions prompted a search in textbooks on how the subject is developed. Besides several instances of inconsistencies in defining the standard state, such as including the temperature in the definition, a number of incorrect depictions of the hydrogen electrode were discovered. Of the 28 General Chemistry books, 16 Physical Chemistry books and 24 Internet pages, 30, 20 and 46%, respectively, showed devices that would not work in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar os efeitos hemodinâmicos e metabólicos, após a administração de solução salina hipertônica (NaCL) 7,5% ou em associação ao hidroxietilamido (HES), em cães com hipovolemia induzida e tratados com cetamina. Após a indução da hipovolemia, administrou-se NaCl 7,5% (4,0ml kg-1) no grupo hipertônica levógira (GHL) e grupo hipertônica racêmica (GHR) ou HES 130/0,4 na mesma proporção de sangue retirado, associado a NaCl 7,5% (4ml kg-1) no grupo hipertônica colóide levógira (GHCL) e no grupo hipertônica colóide racêmica (GHCR). Após 30 minutos, administrou-se, por via IV, cetamina levógira (CL) (5mg kg-1) no GHL e GHCL ou cetamina racêmica (CR) (10mg kg-1) no GHR e GHCR. Empregou-se a análise de variância de uma única via com repetições múltiplas (ANOVA) e o teste de Student Newman Keuls (P£0,05). A frequência cardíaca e a pressão arterial sistólica foram menores após a hipovolemia e após a CR. As pressões arteriais média e diastólica foram menores após a hipovolemia e cetamina. A pressão venosa central foi maior após a administração do colóide. Os índices cardíaco e sistólico foram menores após a hipovolemia em todos os grupos e, após a fase de expansão no GHL e GHR. A pressão média da artéria pulmonar foi menor após a hipovolemia em todos os grupos. A pressão de oclusão da artéria pulmonar foi maior após o colóide. O índice do trabalho ventricular esquerdo foi menor após a hipovolemia no GHCL e GHCR. O índice da resistência periférica total foi maior após a hipovolemia e menor após a CL. Observou-se acidose metabólica após a hipovolemia e após a cetamina. Ocorreu acidose respiratória após a cetamina no GHL e GHR. Conclui-se que a administração de NaCl 7,5% associado ao HES 130/0,4 promove o restabelecimento imediato dos parâmetros hemodinâmicos e metabólicos no paciente hipovolêmico; a administração isolada de NaCl 7,5% não é capaz de restaurar a PAM no período imediato, mas melhora os demais parâmetros hemodinâmicos e metabólicos; a administração de CR ou CL produz efeitos hemodinâmicos e metabólicos similares no paciente hipovolêmico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperature-dependent electrical resistance in quasi-one-dimensional Li(0.9)Mo(6)O(17) is described by two Luttinger liquid anomalous exponents alpha, each associated with a distinct one dimensional band. The band with alpha < 1 is argued to crossover to a higher dimension below the temperature T(M'), leading to superconductivity. Disorder and magnetic fields are shown to induce the Bose metal behavior in this bulk compound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider distributions u is an element of S'(R) of the form u(t) = Sigma(n is an element of N) a(n)e(i lambda nt), where (a(n))(n is an element of N) subset of C and Lambda = (lambda n)(n is an element of N) subset of R have the following properties: (a(n))(n is an element of N) is an element of s', that is, there is a q is an element of N such that (n(-q) a(n))(n is an element of N) is an element of l(1); for the real sequence., there are n(0) is an element of N, C > 0, and alpha > 0 such that n >= n(0) double right arrow vertical bar lambda(n)vertical bar >= Cn(alpha). Let I(epsilon) subset of R be an interval of length epsilon. We prove that for given Lambda, (1) if Lambda = O(n(alpha)) with alpha < 1, then there exists epsilon > 0 such that u vertical bar I(epsilon) = 0 double right arrow u 0; (2) if Lambda = O(n) is uniformly discrete, then there exists epsilon > 0 such that u vertical bar I(epsilon) = 0 double right arrow u 0; (3) if alpha > 1 and. is uniformly discrete, then for all epsilon > 0, u vertical bar I(epsilon) = 0 double right arrow u = 0. Since distributions of the above mentioned form are very common in engineering, as in the case of the modeling of ocean waves, signal processing, and vibrations of beams, plates, and shells, those uniqueness and nonuniqueness results have important consequences for identification problems in the applied sciences. We show an identification method and close this article with a simple example to show that the recovery of geometrical imperfections in a cylindrical shell is possible from a measurement of its dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical reactivity, photolability, and computational studies of the ruthenium nitrosyl complex with a substituted cyclam, fac-[Ru(NO)Cl(2)(kappa(3)N(4),N(8),N(11)(1-carboxypropyl)cyclam)]Cl center dot H(2)O ((1-carboxypropyl) cyclam = 3-(1,4,8,11-tetraazacyclotetradecan-1-yl) propionic acid)), (I) are described. Chloride ligands do not undergo aquation reactions (at 25 degrees C, pH 3). The rate of nitric oxide (NO) dissociation (k(obs-NO)) upon reduction of I is 2.8 s(-1) at 25 +/- 1 degrees C (in 0.5 mol L(-1) HCl), which is close to the highest value found for related complexes. The uncoordinated carboxyl of I has a pK(a) of similar to 3.3, which is close to that of the carboxyl of the non coordinated (1-carboxypropyl) cyclam (pK(a) = 3.4). Two additional pK(a) values were found for I at similar to 8.0 and similar to 11.5. Upon electrochemical reduction or under irradiation with light (lambda(irr) = 350 or 520 nm; pH 7.4), I releases NO in aqueous solution. The cyclam ring N bound to the carboxypropyl group is not coordinated, resulting in a fac configuration that affects the properties and chemical reactivities of I, especially as NO donor, compared with analogous trans complexes. Among the computational models tested, the B3LYP/ECP28MDF, cc-pVDZ resulted in smaller errors for the geometry of I. The computational data helped clarify the experimental acid-base equilibria and indicated the most favourable site for the second deprotonation, which follows that of the carboxyl group. Furthermore, it showed that by changing the pH it is possible to modulate the electron density of I with deprotonation. The calculated NO bond length and the Ru/NO charge ratio indicated that the predominant canonical structure is [Ru(III)NO], but the Ru-NO bond angles and bond index (b.i.) values were less clear; the angles suggested that [Ru(II)NO(+)] could contribute to the electronic structure of I and b.i. values indicated a contribution from [Ru(IV)NO(-)]. Considering that some experimental data are consistent with a [Ru(II)NO(+)] description, while others are in agreement with [Ru(III)NO], the best description for I would be a linear combination of the three canonical forms, with a higher weight for [Ru(II)NO(+)] and [Ru(III)NO].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Small angle X-ray scattering (SAXS) images of normal breast tissue and benign and malignant breast tumour tissues, fixed in formalin, were measured at the momentum transfer range of 0.063 nm(-1) <= q (=4 pi sin(theta/2)/lambda) <= 2.720 nm(-1). Four intrinsic parameters were extracted from the scattering profiles (1D SAXS image reduced) and, from the combination of these parameters, another three parameters were also created. All parameters, intrinsic and derived, were subject to discriminant analysis, and it was verified that parameters such as the area of diffuse scatter at the momentum transfer range 0.50 <= q <= 0.56 nm(-1), the ratio between areas of fifth-order axial and third-order lateral peaks and third-order axial spacing provide the most significant information for diagnosis (p < 0.001). Thus, in this work it was verified that by combining these three parameters it was possible to classify human breast tissues as normal, benign lesion or malignant lesion with a sensitivity of 83% and a specificity of 100%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An investigation was carried out to study the potential use of the angular distribution of scattered photons by human breast samples for a rapid identification of neoplasias of breast tissues. This technique has possible applications as diagnostic aid for breast cancer. In this work, a commercial powder diffractometer was used to obtain the scattering profiles from breast tissues histopathologically classified as normal breast tissues, fibroadenomas (benign breast diseases) and carcinomas (malignant breast diseases), in the interval 0.02 angstrom(-1) < x < 0.62 angstrom(-1). The experimental methods and data corrections are discussed in detail, and they included background subtraction, polarization, self-attenuation and geometric effects. The validation of the experimental procedure was achieved through an analysis of water sample. The results showed that the scattering profile is a unique impression of each type of tissue, being correlated with their microscopic morphological features. Multivariate analysis was applied to these profiles in order to verify if the information carried by these scattering profiles allow the differentiation between normal, benign and malignant breast tissues. The statistical analysis results showed that a correct identification of 75% of the analyzed samples is accomplished. The values of sensibility and specificity of this method in correctly differentiating between normal and neoplastic samples were 95.6% and 82.3%, respectively, while the values for differentiation between benign and malignant neoplasias were 78.6% and 62.5%. These initial results indicate the feasible use of commercial powder diffractometer to provide a rapid diagnostic with a high sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoproduction reactions occur when the electromagnetic field of a relativistic heavy ion interacts with another heavy ion. The STAR Collaboration presents a measurement of rho(0) and direct pi(+)pi(-) photoproduction in ultraperipheral relativistic heavy ion collisions at root s(NN) = 200 GeV. We observe both exclusive photoproduction and photoproduction accompanied by mutual Coulomb excitation. We find a coherent cross section of sigma(AuAu -> Au*Au*rho(0)) = 530 +/- 19(stat.) +/- 57(syst.) mb, in accord with theoretical calculations based on a Glauber approach, but considerably below the predictions of a color dipole model. The rho 0 transverse momentum spectrum (p(T)(2)) is fit by a double exponential curve including both coherent and incoherent coupling to the target nucleus; we find sigma(inc)/sigma(coh) = 0.29 +/- 0.03 (stat.) +/- 0.08 (syst.). The ratio of direct pi(+)pi(-) to rho(0) production is comparable to that observed in gamma(p) collisions at HERA and appears to be independent of photon energy. Finally, the measured rho(0) spin helicity matrix elements agree within errors with the expected s-channel helicity conservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Glycogen storage disease type 0 is an autosomal recessive disease presenting in infancy or early childhood and characterized by ketotic hypoglycemia after prolonged fasting and postprandial hyperglycemia and hyperlactatemia. Sixteen different mutations have been identified to date in the gene which encodes hepatic glycogen synthase, resulting in reduction of glycogen storage in the liver. Case Presentation: Biochemical evaluation as well as direct sequencing of exons and exon-intron boundary regions of the GYS2 gene were performed in a patient presenting fasting hypoglycemia and postprandial hyperglycemia and her parents. The patient was found to be compound heterozygous for one previously reported nonsense mutation (c. 736 C>T; R243X) and a novel frameshift mutation (966_967delGA/insC) which introduces a stop codon 21 aminoacids downstream from the site of the mutation that presumably leads to loss of 51% of the COOH-terminal part of the protein. The glycemia and lactatemia of the parents after an oral glucose tolerance test were evaluated to investigate a possible impact of the carrier status on the metabolic profile. The mother, who presented a positive family history of type 2 diabetes, was classified as glucose intolerant and the father, who did not exhibit metabolic changes after the glucose overload, had an antecedent history of hypoglycemia after moderate alcohol ingestion. Conclusion: The current results expand the spectrum of known mutations in GYS2 and suggest that haploinsufficiency could explain metabolic abnormalities in heterozygous carriers in presence of predisposing conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and Purpose: Bimatoprost and the fixed combination of latanoprost with timolol maleate are 2 medications widely used to treat glaucoma and ocular hypertension (OHT). The aim of the study is to compare the efficacy of these 2 drugs in reducing intraocular pressure (IOP) after 8 weeks of treatment in patients with primary open angle glaucoma (POAG) or OHT. Methods: In this randomized, open-label trial, 44 patients with POAG or OHT were allocated to receive either bimatoprost (1 drop QD) or latanoprost/timolol (1 drop QD). Primary outcome was the mean diurnal IOP measurement at the 8th week, calculated as the mean IOP measurements taken at 8:00 AM, 10: 00 AM, and 12: 00 PM Secondary outcomes included the baseline change in IOP measured 3 times a day, after the water-drinking test (performed after the last IOP measurement), and the assessment of side effects of each therapy. Results: The mean IOP levels of latanoprost/timolol (13.83, SD = 2.54) was significantly lower than of bimatoprost (16.16, SD = 3.28; P < 0.0001) at week 8. Also, the change in mean IOP values was significantly higher in the latanoprost/timolol group at 10:00 AM (P = 0.013) and 12:00 PM (P = 0.01), but not at 8: 00 AM (P = ns). During the water-drinking test, there was no signifi cant difference in IOP increase (absolute and percentage) between groups; however, there was a signifi cant decrease in mean heart rate in the latanoprost/timolol group. Finally, no signifi cant changes in blood pressure and lung spirometry were observed in either groups. Conclusions: The fixed combination of latanoprost/timolol was significantly superior to bimatoprost alone in reducing IOP in patients with POAG or OHT. Further studies with large sample sizes should be taken to support the superior efficacy of latanoprost/timolol, as well as to better assess its profile of side effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of 830-nm laser in blocking the action of nicotine on the viability of skin flap. Background data: The authors have analyzed the deleterious effect of cigarette smoke or nicotine on the skin flap alone with evidence of increased skin necrosis in the flap. Materials and methods: Twenty-four Wistar-albino rats were divided into three groups of eight animals each: Group 1 (control), subjected to a surgical technique to obtain a flap for cranial base, laser irradiation simulation, and a subcutaneous injection of saline; Group 2, similar to Group 1, with subcutaneous injection of nicotine (2mg/kg/day) for a period of 1 week before and 1 week after surgery; and Group 3, similar to Group 2, with skin flaps subjected to a lambda 830-nm laser irradiation. The laser parameters used were: power 30 mW, beam area 0.07cm(2), irradiance 429 mW/cm(2), irradiation time 84 sec, total energy 2.52J, and energy density 36J/cm(2). The laser was used immediately after surgery and for 4 consecutive days, in one point at 2.5 cm of the flap cranial base. The areas of necrosis were examined by two macroscopic analyses: paper template and Mini-Mop (R). The pervious blood vessels were also counted. Results: The results were statistically analyzed by ANOVA and post-test contrast orthogonal method (multiple comparisons), showing that the laser decreased the area of necrosis in flaps subjected to nicotine, and consequently, increased the number of blood vessels (p < 0.05). Conclusions: The laser proved to be an effective way to decrease the area of necrosis in rats subjected to nicotine, making them similar to the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this study was to evaluate the influence of different Er:YAG laser (lambda = 2.94 mu m) energy parameters on the microtensile bond strength (mu TBS) and superficial morphology of bovine enamel bleached with 16% carbamide peroxide. Background: Laser irradiation could improve adhesion to bleached enamel surfaces. Methods: Sixty bovine enamel blocks (7x3x3 mm(3)) were randomly assigned to six groups according to enamel preparation procedures (n = 10): G1-bleaching and Er:YAG laser irradiation with 25.52 J/cm(2) (laser A, LA); G2-bleaching and Er:YAG laser irradiation with 4.42J/cm(2) (laser B, LB); G3-bleaching; G4-Er:YAG laser irradiation with 25.52 J/cm(2); G5-Er:YAG laser irradiation with 4.42J/cm(2); G6-control, no treatment. G1 to G3 were bleached for 6 h during 21 days. Afterwards, enamel surfaces in all groups were slightly abraded with 600-grit SiC papers and G1, G2, G4 and G5 were irradiated according to each protocol. Enamel blocks were then restored with an etch-and-rinse adhesive system and a 4-mm thick composite buildup was made in two increments (n = 9). After 24 h, restored blocks were serially sectioned with a cross-section area of similar to 1 mm(2) at the bonded interface and tested in tension in a universal testing machine (1 mm/min). Failure mode was determined at a magnification of x100 using a stereomicroscope. One treated block of each group was selected for scanning electron microscopy (SEM) analysis. mu TBS data were analyzed by two-way ANOVA and no statistical differences were observed among groups. Results: Mean bond strengths (SD) in MPa were: G1-30.4(6.2); G2-27.9(8.5); G3-32.3(3.9); G4-23.7(5.8); G5-29.3(6.0); G6-29.1(6.1). A large number of adhesive failures was recorded for bleached and irradiated enamel surfaces. Conclusions: Bleached enamel surfaces mu TBS values were not significantly different from those of unbleached enamel. Even though Er:YAG laser irradiation with both parameters had no influence on mu TBS for bleached and unbleached enamel, SEM analysis revealed that Er:YAG laser irradiation with 25.52J/cm(2) should not be recommended, as enamel ablation was observed, whereas irradiation with 4.42J/cm(2) did not promote any remarkable changes on enamel surface.