38 resultados para Haller, Johannes, 1523-1575.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The cerebrospinal fluid (CSF) biomarkers amyloid beta (A beta)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer`s disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer`s Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for A beta, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Molndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure A beta-(1-42), P-tau(181P), and T-tau), and 5 used Mesa Scale Discovery with the A beta triplex (A beta N-42, A beta N-40, and A beta N-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers. (C) 2011 The Alzheimer`s Association. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Helicobacter pylori ClariRes assay is a novel commercially available real-time PCR assay allowing H. pylori detection and clarithromycin susceptibility testing in either gastric biopsy or stool specimens. Objective: The aim of this study was to validate the novel biprobe real-time assay in stool specimens from 217 dyspeptic children. Methods: DNA from gastric biopsies and stool specimens were obtained and submitted to the biprobe real time assay for H. pylori detection and clarithromycin susceptibility testing. Results: The sensitivity, specificity, and test accuracy were 69, 100 and 93.9% for the detection of H. pylori infection and 83.3, 100 and 95.6%, for detection of clarithromycin resistance. Conclusion: This assay proved to be appropriate for H. pylori clarithromycin susceptibility testing, particularly in children populations where a high prevalence of clarithromycin-resistant strains is suspected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background -Schistosomiasis is a highly prevalent disease with >200 million infected people. Pulmonary hypertension is one of the pulmonary manifestations in this disease, particularly in its hepatosplenic presentation. The aim of this study was to determine the prevalence of pulmonary hypertension in schistosomiasis patients with the hepatosplenic form of the disease. Methods and Results -All patients with hepatosplenic schistosomiasis followed up at the gastroenterology department of our university hospital underwent echocardiographic evaluation to search for pulmonary hypertension. Patients presenting with systolic pulmonary artery pressure >40 mm Hg were further evaluated through right heart catheterization. Our study showed an 18.5% prevalence of patients with elevated systolic pulmonary artery pressure at echocardiography. Invasive hemodynamics confirmed the presence of pulmonary hypertension in 7.7% (95% confidence interval, 3.3 to 16.7) of patients, with a prevalence of precapillary (arterial) pulmonary hypertension of 4.6% (95% confidence interval, 1.5 to 12.7). Conclusions -Our study reinforces the role of echocardiography as a screening tool in the investigation of pulmonary hypertension, together with the need for invasive monitoring for a proper diagnosis. We conclude that hepatosplenic schistosomiasis may account for one of the most prevalent forms of pulmonary hypertension worldwide, justifying the development of further studies to evaluate the effect of specific pulmonary hypertension treatment in this particular form of the disease. (Circulation. 2009; 119: 1518-1523.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context Novel therapies have improved the remission rate in chronic inflammatory disorders including juvenile idiopathic arthritis (JIA). Therefore, strategies of tapering therapy and reliable parameters for detecting subclinical inflammation have now become challenging questions. Objectives To analyze whether longer methotrexate treatment during remission of JIA prevents flares after withdrawal of medication and whether specific biomarkers identify patients at risk for flares. Design, Setting, and Patients Prospective, open, multicenter, medication-withdrawal randomized clinical trial including 364 patients (median age, 11.0 years) with JIA recruited in 61 centers from 29 countries between February 2005 and June 2006. Patients were included at first confirmation of clinical remission while continuing medication. At the time of therapy withdrawal, levels of the phagocyte activation marker myeloid-related proteins 8 and 14 heterocomplex (MRP8/14) were determined. Intervention Patients were randomly assigned to continue with methotrexate therapy for either 6 months (group 1 [n = 183]) or 12 months (group 2 [n = 181]) after induction of disease remission. Main Outcome Measures Primary outcome was relapse rate in the 2 treatment groups; secondary outcome was time to relapse. In a prespecified cohort analysis, the prognostic accuracy of MRP8/14 concentrations for the risk of flares was assessed. Results Intention-to-treat analysis of the primary outcome revealed relapse within 24 months after the inclusion into the study in 98 of 183 patients (relapse rate, 56.7%) in group 1 and 94 of 181 (55.6%) in group 2. The odds ratio for group 1 vs group 2 was 1.02 (95% CI, 0.82-1.27; P=.86). The median relapse-free interval after inclusion was 21.0 months in group 1 and 23.0 months in group 2. The hazard ratio for group 1 vs group 2 was 1.07 (95% CI, 0.82-1.41; P=.61). Median follow-up duration after inclusion was 34.2 and 34.3 months in groups 1 and 2, respectively. Levels of MRP8/14 during remission were significantly higher in patients who subsequently developed flares (median, 715 [IQR, 320-1110] ng/mL) compared with patients maintaining stable remission (400 [IQR, 220-800] ng/mL; P=.003). Low MRP8/14 levels indicated a low risk of flares within the next 3 months following the biomarker test (area under the receiver operating characteristic curve, 0.76; 95% CI, 0.62-0.90). Conclusions In patients with JIA in remission, a 12-month vs 6-month withdrawal of methotrexate did not reduce the relapse rate. Higher MRP8/14 concentrations were associated with risk of relapse after discontinuing methotrexate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stress distributions in torsion and wire-loop shear tests were compared using three-dimensional (3-D) linear-elastic finite element method, in an attempt to predict the ideal conditions for testing adhesive strength of dental resin composites to dentin. The torsion test presented lower variability in stress concentration at the adhesive interface with changes in the proportion adhesive thickness/resin composite diameter, as well as lower variability with changes in the resin composite elastic modulus. Moreover, the torsion test eliminated variability from changes in loading distance, and reduced the cohesive fracture tendency in the dentin. The torsion test seems to be more appropriate than wire-loop shear test for testing the resin composite-tooth interface strength. (c) Koninklijke Brill NV, Leiden, 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the field of regenerative medicine, nanoscale physical cuing is clearly becoming a compelling determinant of cell behavior. Developing effective methods for making nanostructured surfaces with well-defined physicochemical properties is thus mandatory for the rational design of functional biomaterials. Here, we demonstrate the versatility of simple chemical oxidative patterning to create unique nanotopographical surfaces that influence the behavior of various cell types, modulate the expression of key determinants of cell activity, and offer the potential of harnessing the power of stem cells. These findings promise to lead to a new generation of improved metal implants with intelligent surfaces that can control biological response at the site of healing.