63 resultados para Eye.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the detection of exotic massive strongly interacting hadrons (uhecrons) in ultrahigh energy cosmic ray telescopes. The conclusion is that experiments such as the Pierre Auger Observatory have the potential to detect these particles. It is shown that uhecron showers have clear distinctive features when compared to proton and nuclear showers. The simulation of uhecron air showers, and its detection and reconstruction by fluorescence telescopes, is described. We determine basic cuts in observables that will separate uhecrons from the cosmic ray bulk, assuming this is composed by protons. If these are composed by a heavier nucleus, the separation will be much improved. We also discuss photon induced showers. The complementarity between uhecron detection in accelerator experiments is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the ocular toxicity of escalating doses of intravitreous adalimumab (Humira (R)) in the rabbit eye. Methods: Thirty New Zealand albino rabbits received intravitreous injections of 0.5mg (6 eyes), 1.0mg (6 eyes), 2.5mg (6 eyes), 5mg (6 eyes), and 10mg (6 eyes) adalimumab. Slit lamp biomicroscopy and fundoscopy were carried out at baseline, day 7, and day 14 after intravitreous injection, whereas electroretinography (ERG) was carried out at baseline and day 14. Animals were euthanized on day 14, and histopathological examination of the eyes was performed. Results: Slit lamp biomicroscopy and fundoscopy were normal in all eyes receiving doses up to 5mg. In the 10mg group, 3 of 6 eyes showed mild anterior chamber inflammatory reaction on day 7. Similarly, scotopic and photopic a- and b-wave ERG amplitudes at baseline and day 14 were similar in all groups up to 5mg, but there was a significant decrease in the photopic-wave ERG response in the 10mg group (P = 0.046). Finally, histopathology demonstrated no differences among eyes receiving balanced salt solution, 0.5, 1.0, 2.5, 5.0, or 10mg of adalimumab. Conclusions: Intravitreous adalimumab exhibited no associated ocular short-term toxicity in rabbit eyes up to the 5mg dose. In the 10mg group mild clinical findings and ERG amplitude reduction could reflect early toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The selection of candidate plus trees of desirable phenotypes from tropical forest trees and the rapid devastation of the natural environments in which these trees are found have created the need for a more detailed knowledge of the floral and reproductive biology of tropical tree species. In this article, the organogenic processes related to unisexual flower development in tropical mahogany, Swietenia macrophylla, are described. Mahogany inflorescences at different developmental stages were evaluated using scanning electron microscopy or optical microscopy of histological sections. The unisexual flowers of S. macrophylla are usually formed in a thyrse, in which the positions of the female and male flowers are not random. Differences between male and female flowers arise late during development. Both female and male flowers can only be structurally distinguished after stage 9, where ovule primordia development is arrested in male flowers and microspore development is aborted in female flower anthers. After this stage, male and female flowers can be distinguished by the naked eye as a result of differences in the dimensions of the gynoecium. The floral characteristics of S. macrophylla (distribution of male and female flowers within the inflorescence, and the relative number of male to female flowers) have practical implications for conservation strategies of this endangered species. (c) 2008 The Linnean Society of London, Botanical Journal of the Linnean Society, 2008, 156, 529-535.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The localization of upper airway obstruction in patients with obstructive sleep apnea (OSA) may optimize treatment. Nasoendoscopy during propofol sedation allows such an evaluation, but the effect of this drug on respiratory patterns and muscle relaxation is unknown. The objective of the present study was to determine through polysomnography whether propofol would change sleep parameters. STUDY DESIGN: Prospective study of subjects submitted to polysomnography under sedation with propofol. SETTING: Tertiary referral center. SUBJECTS AND METHODS: Fifteen non-obese subjects (4 controls/11 OSA patients) were submitted to two diurnal polysomnograms (90-120 minutes of sleep), with and without the use of propofol. The parameters presence of snoring, apnea-hypopnea index (AHI), oxygen desaturation, and sleep architecture were compared. RESULTS: The use of propofol did not induce snoring in the control subjects, whereas 100 percent of the OSA patients snored. AHI and mean oxygen saturation (SaO(2)) did not differ significantly between examinations with and without sedation. However, minimum SaO(2) differed significantly (P < 0.05) with sedation, being lower during propofol sedation. Propofol also significantly changed the sleep architecture, with a significant increase in N3 sleep (P < 0.005) and total abolishment of rapid eye movement sleep (P < 0.0005) during propofol sedation. CONCLUSIONS: These preliminary results allow us to infer that sedation with propofol changes sleep architecture but permits respiratory evaluation, because the main respiratory parameters evaluated in OSA are maintained. These preliminary results support the view that nasoendoscopy under propofol sedation is a promising examination for management of this disease. (C) 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of peripheral vision to organize and reorganize an interceptive action was investigated in young adults. Temporal errors and kinematic variables were evaluated in the interception of a virtual moving target, in situations in which its initial velocity was kept unchanged or was unexpectedly decreased. Observation of target approach was made through continuous visual pursuit (focal vision) or keeping visual focus at the origin of the trajectory or at the contact spot (peripheral vision). Results showed that visual focus at the contact spot led to temporal errors similar to focal vision, although showing a distinct kinematic profile, while focus at the origin led to an impoverished performance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to examine the coupling between visual information and body sway with binocular and monocular vision at two distances from the front wall of a moving room. Ten participants stood as still as possible inside of a moving room facing the front wall in conditions that combined room movement with monocular/binocular vision and distance from the front wall (75 and 150cm). Visual information effect on body sway decreased with monocular vision and with increased distance from the front wall. In addition, the combination of monocular vision with the farther distance resulted in the smallest body sway response to the driving stimulus provided by the moving room. These results suggest that binocularvision near the front wall provides visual information of a better quality than the monocular vision far from the front wall. We discuss the results with respect to two modes of visual detection of body sway: ocular and extraocular. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A secure communication system based on the error-feedback synchronization of the electronic model of the particle-in-a-box system is proposed. This circuit allows a robust and simple electronic emulation of the mechanical behavior of the collisions of a particle inside a box, exhibiting rich chaotic behavior. The required nonlinearity to emulate the box walls is implemented in a simple way when compared with other analog electronic chaotic circuits. A master/slave synchronization of two circuits exhibiting a rich chaotic behavior demonstrates the potentiality of this system to secure communication. In this system, binary data stream information modulates the bifurcation parameter of the particle-in-a-box electronic circuit in the transmitter. In the receiver circuit, this parameter is estimated using Pecora-Carroll synchronization and error-feedback synchronization. The performance of the demodulation process is verified through the eye pattern technique applied on the recovered bit stream. During the demodulation process, the error-feedback synchronization presented better performance compared with the Pecora-Carroll synchronization. The application of the particle-in-a-box electronic circuit in a secure communication system is demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data from 9 studies were compiled to evaluate the effects of 20 yr of selection for postweaning weight (PWW) on carcass characteristics and meat quality in experimental herds of control Nellore (NeC) and selected Nellore (NeS), Caracu (CaS), Guzerah (GuS), and Gir (GiS) breeds. These studies were conducted with animals from a genetic selection program at the Experimental Station of Sertaozinho, Sao Paulo State, Brazil. After the performance test (168 d postweaning), bulls (n = 490) from the calf crops born between 1992 and 2000 were finished and slaughtered to evaluate carcass traits and meat quality. Treatments were different across studies. A meta-analysis was conducted with a random coefficients model in which herd was considered a fixed effect and treatments within year and year were considered as random effects. Either calculated maturity degree or initial BW was used interchangeably as the covariate, and least squares means were used in the multiple-comparison analysis. The CaS and NeS had heavier (P = 0.002) carcasses than the NeC and GiS; GuS were intermediate. The CaS had the longest carcass (P < 0.001) and heaviest spare ribs (P < 0.001), striploin (P < 0.001), and beef plate (P = 0.013). Although the body, carcass, and quarter weights of NeS were similar to those of CaS, NeS had more edible meat in the leg region than did CaS bulls. Selection for PWW increased rib-eye area in Nellore bulls. Selected Caracu had the lowest (most favorable) shear force values compared with the NeS (P = 0.003), NeC (P = 0.005), GuS (P = 0.003), and GiS (P = 0.008). Selection for PWW increased body, carcass, and meat retail weights in the Nellore without altering dressing percentage and body fat percentage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to evaluate possible cytotoxic effects of topical creams and lotions produced with Buriti oil and commercial surfactants on human keratinocytes HaCat and 3T3 embryonic mouse fibroblast cultures. We also aimed to assess the cytotoxicity of the surfactants used to produce the emulsions. The neutral red release (NRR) assay was performed as an in vitro method to evaluate the cytotoxicity of the emulsions in HaCat and 3T3 cell lines and predict potential skin irritation. The Buriti oil emulsions presented low cytotoxicity to the cells at high concentrations and the addition of Vitamin E increased cell viability. Among the surfactant tested, Unitol(R) CE 200F proved to be the most cytotoxic, presenting an IC50 significantly lower than the others. Emulsions formulated with Buriti oil and commercial surfactants could be non irritant to the skin due to their low cytotoxicity, especially when enhanced with vitamin E. When emulsified with Buriti oil, water and Brij 72, Unitol CE200F showed less cytotoxic effects than when tested alone. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present work was to obtain an ophthalmic delivery system with improved mechanical and mucoadhesive properties that could provide prolonged retention time for the treatment of ocular diseases. For this, an in situ forming gel comprised of the combination of a thermosetting polymer, poly (ethylene oxide)-poly (propylene oxide)-poly (ethylene oxide) (PEO-PPO-PEO, poloxamer), with a mucoadhesive agent (chitosan) was developed. Different polymer ratios were evaluated by oscillatory rheology, texture and mucoadhesive profiles. Scintigraphy studies in humans were conduced to verify the retention time of the formulations developed. The results showed that chitosan improves the mechanical strength and texture properties of poloxamer formulations and also confers mucoadhesive properties in a concentration-dependent manner. After a 10-min instillation of the poloxamer/chitosan 16:1 formulation in human eyes, 50-60% of the gel was still in contact with the cornea surface, which represents a fourfold increased retention in comparison with a conventional solution. Therefore, the developed formulation presented adequate mechanical and sensorial properties and remained in contact with the eye surface for a prolonged time. In conclusion, the in situ forming gel comprised of poloxamer/chitosan is a promising tool for the topical treatment of ocular diseases. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have observed changes in the lacrimal gland and ocular surface related to diabetes mellitus and related it to insulin resistance or insufficiency and oxidative damage. The aim of this study was to evaluate whether insulin treatment inhibits those changes. Diabetes was induced in male Wistar rats with a single intravenous injection of streptozotocin and a subgroup was treated with insulin. After 5 and 10 weeks, the three groups (n = 5-10/group/experimental procedure) were compared for biochemical, functional, and histological parameters. After 5 weeks, changes in morphology and increased numbers of lipofucsin-like inclusions were observed in lacrimal glands of diabetic but not insulin-treated rats. After 5 weeks, malonaldehyde and total peroxidase activity were significantly higher in diabetic rats, but similar to control in insulin-treated diabetic rats (P = 0.03, P = 0.02, respectively). Our data indicate that diabetes induces histological alterations in lacrimal gland and suggests that hyperglycemia-related oxidative stress may participate in diabetic dry eye syndrome. Prevention by insulin replacement suggests direct hormone action and/or benefit by early sub optimal metabolic control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Managing financial institutions in an underdeveloped economic context has become a real challenge nowadays. In order to reach the organization`s planned goals, they have to deal with structural, behavioral and informational problems. From the systemic point of view, this situation gets even worse when the company does not present organizational boundaries and a cohesive identification for their stakeholders. Thus, European countries have some special financial lines in order to help the development of micro credit in Latin communities in an attempt to help the local economy. However, institutions like Caixa dos Andes in Peru present management problems when dealing with this complexity. Based on this, how can the systemic eye help in the diagnosis of soft problems of a Peruvian financial company? This study aims to diagnose soft problems of a Peruvian financial company based on soft variables like identity, communication and autonomy and also intends to identify possible ways to redesign its basic framework. The (VSM--Viable System Model) method from Beer (1967), applied in this diagnostic study, was used in a practical way as a management tool for organizations` analysis and planning. By describing the VSM`s five systems, the creation of a systemic vision or a total vision is possible, showing the organization`s complexity from the inside. Some company`s soft problems like double control, inefficient use of physical and human resources, low information flows, slowness, etc. The VSM presented an organizational diagnosis indicating effective solutions that do integrate its five systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To compare the analgesic effectiveness and aesthetic appearance associated with topical, subconjunctival, and peribulbar anesthesia for intravitreal bevacizumab injection. PATIENTS AND METHODS: Sixty consecutive patients undergoing their first intravitreal bevacizumab injection were randomized to receive one of three forms of anesthesia: proxymetacaine eye drops, subconjunctival injection of 2% xylocaine, and peribulbar injection of 2% xylocaine. Pain associated with the intravitreal injection and with the entire procedure (including anesthesia administration) was recorded using a Visual Analog Scale 15 minutes after intravitreal injection. Anterior segment evaluation was performed 24 hours after injection to measure the number of clock hours of subconjunctival hemorrhage. RESULTS: Median injection-related pain score was significantly lower in the peribulbar group compared with the topical and subconjunctival groups (P < .05). Median entire procedure pain score was significantly higher In the peribulbar group compared with the topical and subconjunctival groups (P < .05). The median extent of subconjunctival hemorrhage was significantly lower in the topical group compared with the other groups (P < .05). CONCLUSION: Among the three anesthetic techniques, peribulbar anesthesia was associated with greater effectiveness in controlling injection-related pain but was least effective in controlling entire procedure pain. There was no significant difference in pain scores between the topical and subconjunctival groups, and topical anesthesia was associated with less subconjunctival hemorrhage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare changes in corneal hysteresis (CH) and the corneal resistance factor (CRF) in myopic and hyperopic laser in situ keratomileusis (LASIK) and evaluate their relationship to the number of photoablative pulses delivered, a surrogate for ablation volume. SETTING: Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA. METHODS: Preoperative and 1-week postoperative Ocular Response Analyzer measurements in eyes that had femtosecond-assisted LASIK were studied retrospectively. Changes in CH and CRF were compared and tested for correlation with the number of excimer laser pulses. RESULTS: Thirteen myopic eyes and 11 hyperopic eyes were evaluated. Preoperative corneal thickness, CH, CRF, programmed correction magnitude, flap thickness, and total number of fixed spotsize photoablative pulses were similar in the 2 groups (P>.1). Decreases in CH and CRF were greater after myopic LASIK than after hyperopic LASIK (P<.005), and changes in CRF were correlated with the number of excimer laser pulses in the myopic group only (r = -0.63, P = .02). Regardless of ablation profile, changes in CH were more strongly correlated with preoperative CH values than with attempted ablation volume. CONCLUSIONS: With comparable flap thickness and attempted ablation volumes, myopic photoablation profiles were associated with greater decreases in CRF and CH than hyperopic profiles. Results indicate that preoperative corneal biomechanical status, ablation volume, and the spatial distribution of ablation are important factors that affect corneal resistance and viscous dissipative properties differently. Preferential tissue removal in the natively thicker paracentral cornea in hyperopia may partially account for the rarity of ectasia after hyperopic LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.