93 resultados para Brine shrimp artemia salina lethality test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Study Aim: Judo is very physiological demanding sport, but there are no many physical fitness specific tests. One of the most used specific judo tests is the Special Judo Fitness Test (SJFT) proposed by Sterkowicz ( 1995). Although this test has been used by many coaches in different countries no classificatory table was found to classify the judo athletes according to their results. Thus, the aim of this work was to present a classificatory table for this test. Material/Methods: For this purpose 141 judo athletes ( mean +/-standard deviation: 21.3+/-4.5years-old; 74.2+/-15.9 kg of body mass and 176.7+/-8.2 cm of height; judo ranking between 3(rd) kyu and 3(rd) dan) familiarized with the SJFT performed it once in order to provide data to establish a classificatory table. Results: After the analysis of data distribution a five scale table (20% for each classificatory category) was developed considering the variables used in the SJFT ( number of throws, heart rate after and 1 min after the test and index). Conclusions: The classificatory table can help coaches using the SJFT to classify their athletes` level and to monitor their physical fitness progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the usefulness of a semi-tethered field running test (STR) and the relationships between indices of anaerobic power, anaerobic capacity and running performance in 9 trained male sprinters (22.2 +/- 2.9 yrs, 176 +/- 1 cm, 68.0 +/- 9.4 kg). STR involved an all out 120 m run attached to an apparatus that enabled power calculation from force and velocity measures. Subjects also carried out a cycloergometer Win-gate Anaerobic Test (WT), an all out 300 m run and had accessed their maximal accumulated oxygen deficit (MAOD) on a treadmill. Peak and mean powers attained in STR (1 720 +/- 221 and 1 391 +/- 201 W) were greater but significantly related (r=0.82; P<0.01) to those in the WT (808 +/- 130 and 603 +/- 87 W). In addition, power measures derived from the STR were stronger related to running performance compared to those from the WT (r=0.81-0.94 vs. 0.68-0.84; P<0.05). Relationships between MAOD and most power indices were only weak to moderate. These results support the usefulness of STR for specific power assessment in field running and suggest that anaerobic power and capacity are not related entities, irrespective of having been evaluated using similar or dissimilar exercise modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no normalized test to assess the shear strength of vertical interfaces of interconnected masonry walls. The approach used to evaluate this strength is normally indirect and often unreliable. The aim of this study is to propose a new test specimen to eliminate this deficiency. The main features of the proposed specimen are failure caused by shear stress on the vertical interface and a small number of units (blocks). The paper presents a numerical analysis based on the finite element method, with the purpose of showing the theoretical performance of the designed specimen, in terms of its geometry, boundary conditions, and loading scheme, and describes an experimental program using the specimen built with full- and third-scale clay blocks. The main conclusions are that the proposed specimen is easy to build and is appropriate to evaluate the sheaf strength of vertical interfaces of masonry walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wetting balance tests of copper sheets submerged in tin solder baths were carried out in a completely automatic wetting balance. Wetting curves were examined for three different values of sheet thickness and four different solder bath temperatures. Most of the wetting curves showed a distorted shape relative to that of a standard curve, preventing calculation of important wetting parameters, such as the wetting rate and the wetting force. The wetting tests showed that the distortion increased for a thicker sheet thickness and a lower solder bath temperature, being the result of solder bath solidification around the submerged sheet substrate. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was aimed to evaluate the penetration behaviour of different brines with tumbled beef steaks from the biceps femoris muscle, specifically their interactions with pH and effects on yield. Six muscles from different animals, divided into origin (OP) and insertion (IP) portions, were cut into 60 steaks of 2.5 cm thickness and tumbled for 30 or 60 min. The steaks were tumbled with two brines, with (WTB/HSP) or without (WTB) hydrolysed soy protein (HSP), and steaks that were not tumbled with brine or water were used as controls. Brine penetration was verified by measuring the amount of dye-containing brine (absorbance at 627 nm) recovered from homogenates of four thin (2 mm) slices from the surface of the beef steaks after tumbling. The WTB/HSP steaks exhibited greater (P < 0.05) brine penetration when tumbled for 60 min than for 30 min. The OP steaks showed greater yield and lower pH (P < 0.05) than IP steaks. HSP-added brine increased the water absorption and retention in the first slices of the steaks, and its efficiency was increased with a longer tumbling time. The portion of the biceps femoris muscle used influenced brine absorption and retention, impacting meat yield. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 152,145 weekly test-day milk yield records from 7317 first lactations of Holstein cows distributed in 93 herds in southeastern Brazil were analyzed. Test-day milk yields were classified into 44 weekly classes of DIM. The contemporary groups were defined as herd-year-week of test-day. The model included direct additive genetic, permanent environmental and residual effects as random and fixed effects of contemporary group and age of cow at calving as covariable, linear and quadratic effects. Mean trends were modeled by a cubic regression on orthogonal polynomials of DIM. Additive genetic and permanent environmental random effects were estimated by random regression on orthogonal Legendre polynomials. Residual variances were modeled using third to seventh-order variance functions or a step function with 1, 6,13,17 and 44 variance classes. Results from Akaike`s and Schwarz`s Bayesian information criterion suggested that a model considering a 7th-order Legendre polynomial for additive effect, a 12th-order polynomial for permanent environment effect and a step function with 6 classes for residual variances, fitted best. However, a parsimonious model, with a 6th-order Legendre polynomial for additive effects and a 7th-order polynomial for permanent environmental effects, yielded very similar genetic parameter estimates. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the results of an on-farm test, named Somaticell, with results of electronic cell counting and for milk somatic cell count (SCC) among readers. The Somaticell test correctly determined the SCC in fresh quarter milk samples. Correlation between Somaticell and electronic enumeration of somatic cells was 0.92 and. coefficient 0.82. Using a threshold of 205,000 cells/mL, the sensitivity and specificity for determination of intramammary infections were 91.3 and 96.0%, respectively. The SCC was greater for milk samples from which major mastitis pathogens were recovered. Minor variation among readers was observed and most likely associated with the mixing procedure. However, the final analysis indicated that this variation was not significant and did not affect the amount of samples classified as having subclinical mastitis. The on-farm test evaluated in this study showed adequate capacity of determining SCC on quarter milk samples and may be considered as an alternative for on-farm detection of subclinical mastitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to develop and test a procedure for applying variable rates of fertilizers and evaluate yield response in coffee (Coffea arabica L.) with regard to the application of phosphorus and potassium. The work was conducted during the 2004 season in a 6.4 ha field located in central Sao Paulo state. Two treatments were applied with alternating strips of fixed and variable rates during the whole season: one following the fertilizing procedures recommended locally, and the other based on a grid soil sampling. A prototype pneumatic fertilizer applicator was used, carrying two conveyor belts, one for each row. Harvesting was done with a commercial harvester equipped with a customized volumetric yield monitor, separating the two treatments. Data were analyzed based on geostatistics, correlations and regressions. The procedure showed to be feasible and effective. The area that received fertilizer applications at a variable rate showed a 34% yield increase compared to the area that received a fixed rate. The variable rate fertilizer resulted in a savings of 23% in phosphate fertilizer and a 13% increase in potassium fertilizer, when compared to fixed rate fertilizer. Yield in 2005, the year after the variable rate treatments, still presented residual effect from treatments carried out during the previous cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correct modeling of root water uptake partitioning over depth is an important issue in hydrological and crop growth models. Recently a physically based model to describe root water uptake was developed at single root scale and upscaled to the root system scale considering a homogeneous distribution of roots per soil layer. Root water uptake partitioning is calculated over soil layers or compartments as a function of respective soil hydraulic conditions, specifically the soil matric flux potential, root characteristics and a root system efficiency factor to compensate for within-layer root system heterogeneities. The performance of this model was tested in an experiment performed in two-compartment split-pot lysimeters with sorghum plants. The compartments were submitted to different irrigation cycles resulting in contrasting water contents over time. The root system efficiency factor was determined to be about 0.05. Release of water from roots to soil was predicted and observed on several occasions during the experiment; however, model predictions suggested root water release to occur more often and at a higher rate than observed. This may be due to not considering internal root system resistances, thus overestimating the ease with which roots can act as conductors of water. Excluding these erroneous predictions from the dataset, statistical indices show model performance to be of good quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Potassium (K) plays an important role in many physiological and biochemical processes in plants and its adequate use is an important issue for sustainable economic crop production. Soil test-based K fertilizer recommendations are very limited for lowland rice (Oryza sativa L.) grown on Inceptisols. The objective of this study was to calibrate K soil testing for the response of lowland rice (cv. Ipagri 109) to added K. A field experiment was conducted in the farmers` field in the municipality of Lagoa da Confusao, State of Tocantins, central Brazil. The K rates used were 0, 125, 250, 375, 500, and 625 kg K ha-1 applied as broadcast and incorporated during sowing of the first rice crop. Rice responded significantly to K fertilization during 2 years of experimentation. Maximum grain yield of about 6,000 kg ha-1 was obtained with 57 mg K kg-1 soil in the first year and with 30 mg K kg-1 in the second year. This indicated that at low levels of K in the soil, nonexchangeable K was available for plant growth. Potassium use efficiency designated as agronomic efficiency (kg grain produced/kg K applied) decreased significantly in a quadratic fashion with increasing K level in the soil. Agronomic efficiency had a significantly linear association with grain yield. Hence, improving agronomic efficiency with management practices can improve rice yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate how beaker size, basket assembly, use of disk, and immersion medium impact the disintegration time of dietary supplements. The disintegration times were determined for five tablet and two capsule products. A two-station disintegration tester was used with Apparatus A or Apparatus B as described in the United States Pharmacopeia (USP) chapters, < 701 > and < 2040 >. Two beakers complying with the harmonized specifications were used, one with a volume of 1,000 mL and one with a 1,500-mL volume. The disintegration data were analyzed using ANOVA for the following factors: beaker size, equipment (App A and B) and condition (with/without disk). Two tablet products were not sensitive to any changes in the test conditions or equipment configurations. One product was only partially sensitive to the test conditions. The other products showed impact on the disintegration time for all test conditions. The results revealed that these tablet products might pass or fail current USP disintegration requirements depending on the equipment configuration. Similar results were obtained for the two investigated capsule formulations. One product might fail current USP disintegration requirements if the large beaker was used, but might pass the disintegration requirements when the small beaker was used. Hydroxy propyl methyl cellulose capsules were mostly influenced if sodium instead of a potassium buffer was used as the immersion medium. The results demonstrate that the current harmonized ICH specifications for the disintegration test are insufficient to make the disintegration test into reliable test for dietary supplements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A dichloromethane-methanol extract of the seeds of Piper tuberculatum Jacq. (Piperaceae) and two isobutyl amides, 4,5-dihydropiperlonguminine (1) and pellitorine (2), which were isolated by chromatographic methods, were assayed for their lethality against the sugarcane borer Diatraea saccharalis F. (Lepidoptera: Pyralidae). RESULTS: Bioassays were carried out with fourth-instar caterpillars through topical application of test solutions to the dorsal surface of the prothorax, and dose-response correlations were determined. Significant insect mortalities were observed 24, 48 and 72 h after treatment at concentrations of >= 100 mu g insect(-1). The LD(50) and LD(90) values for compound 1 were 92.83 and 176.50 mu g insect(-1), and for compound 2 they were 91.19 and 184.56 mu g insect(-1). CONCLUSION: According to the LD(50) and LD(90) for compounds 1 and 2, it can be inferred that the values reflect an acute lethal response to both compounds, based on interaction(s) of the toxicants with a primary target or series of targets. Thus, the amides were demonstrated to have potential value in the control of the sugarcane borer. (C) 2008 Society of Chemical Industry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to evaluate possible cytotoxic effects of topical creams and lotions produced with Buriti oil and commercial surfactants on human keratinocytes HaCat and 3T3 embryonic mouse fibroblast cultures. We also aimed to assess the cytotoxicity of the surfactants used to produce the emulsions. The neutral red release (NRR) assay was performed as an in vitro method to evaluate the cytotoxicity of the emulsions in HaCat and 3T3 cell lines and predict potential skin irritation. The Buriti oil emulsions presented low cytotoxicity to the cells at high concentrations and the addition of Vitamin E increased cell viability. Among the surfactant tested, Unitol(R) CE 200F proved to be the most cytotoxic, presenting an IC50 significantly lower than the others. Emulsions formulated with Buriti oil and commercial surfactants could be non irritant to the skin due to their low cytotoxicity, especially when enhanced with vitamin E. When emulsified with Buriti oil, water and Brij 72, Unitol CE200F showed less cytotoxic effects than when tested alone. (C) 2008 Elsevier Ltd. All rights reserved.