24 resultados para scanner
Resumo:
Although abnonnalities in brain structures involved in the neurobiology of fear and anxiety have been implicated in the pathophysiology of panic disorder (PD), relatively few studies have made use of voxel-based morphometry (VBM) magnetic resonance imaging (MRI) to determine structural brain abnormalities in PD. We have assessed gray matter volume in 19 PD patients and 20 healthy volunteers using VBM. Images were acquired using a 1.5 T MRI scanner, and were spatially normalized and segmented using optimized VBM. Statistical comparisons were performed using the general linear model. A relative increase in gay matter volume was found in the left insula of PD patients compared with controls. Additional structures showing differential increases were the left superior temporal gyrus, the midbrain, and the pons. A relative gray matter deficit was found in the right anterior cingulate cortex. The insula and anterior cingulate abnormalities may be relevant to the pathophysiology of PD, since these structures participate in the evaluation process that ascribes negative emotional meaning to potentially distressing cognitive and interoceptive sensory information. The abnormal brain stem structures may be involved in the generation of panic attacks. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Visceral abdominal fat has been associated to cardiovascular risk factors and coronary artery disease (CAD). Computed tomography (CT) coronary angiography is an emerging technology allowing detection of both obstructive and nonobstructive CAD adding information to clinical risk strati. cation. The aim of this study was to evaluate the association between CAD and adiposity measurements assessed clinically and by CT. We prospectively evaluated 125 consecutive subjects (57% men, age 56.0 +/- 12 years) referred to perform CT angiography. Clinical and laboratory variables were determined and CT angiography and abdominal CT were performed in a 64-slice scanner. CAD was defined as any plaque calcified or not detected by CT angiography. Visceral and subcutaneous adiposity areas were determined at different intervertebral levels. CT angiography detected CAD in 70 (56%) subjects, and no association was found with usual anthropometric adiposity measurements (waist and hip circumferences and body mass index). Otherwise, CT visceral fat areas (VFA) were significantly related to CAD. VFA T12-L1 values >= 145 cm(2) had an odds ratio of 2.85 (95% CI 1.30-6.26) and VFA L4-L5 >= 150 cm(2) had a 2.87-fold (95% CI 1.31-6.30) CAD risk. The multivariate analysis determined age and VFA T12-L1 as the only independent variables associated to CAD. Visceral fat assessed by CT is an independent marker of CAD determined by CT angiography. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background Chronic aortic valve disease (AVD) is characterized by progressive accumulation of interstitial myocardial fibrosis (MF). However, assessment of MF accumulation has only been possible through histologic analyses of endomyocardial biopsies. We sought to evaluate contrast-enhanced magnetic resonance imaging (ce-MRI) as a noninvasive method to identify the presence of increased MF in patients with severe AVD. Methods Seventy patients scheduled to undergo aortic valve replacement surgery were examined by cine and ce-MRI in a 1.5-T scanner. Cine images were used for the assessment of left ventricular (LV) volumes, mass, and function. Delayed-enhancement images were used to characterize the regions of MF. In addition, histologic analyses of myocardial samples obtained during aortic valve replacement surgery were used for direct quantification of interstitial MF. Ten additional subjects who died of noncardiac causes served as controls for the quantitative histologic analyses. Results Interstitial MF determined by histopathologic analysis was higher in patients with AVID than in controls (2.7% +/- 2.0% vs 0.6% +/- 0.2%, P =.001). When compared with histopathologic results, ce-MRI demonstrated a sensitivity of 74%, a specificity of 81%, and an accuracy of 76% to identify AVD patients with increased interstitial MF There was a significant inverse correlation between interstitial MF and LV ejection fraction (r = -0.67, P <.0001). Accordingly, patients with identifiable focal regions of MF by ce-MRI exhibited worse LV systolic function than those without MF (45% +/- 14% vs 65% +/- 14%, P <.0001). Conclusions Contrast-enhanced MRI allows for the noninvasive detection of focal regions of MF in patients with severe AVD. Moreover, patients with identifiable MF by ce-MRI exhibited worse LV functional parameters. (Am Heart J 2009; 157:361-8.)
Resumo:
Neuroimaging studies in bipolar disorder report gray matter volume (GMV) abnormalities in neural regions implicated in emotion regulation. This includes a reduction in ventral/orbital medial prefrontal cortex (OMPFC) GMV and, inconsistently, increases in amygdala GMV. We aimed to examine OMPFC and amygdala GMV in bipolar disorder type 1 patients (BPI) versus healthy control participants (HC), and the potential confounding effects of gender, clinical and illness history variables and psychotropic medication upon any group differences that were demonstrated in OMPFC and amygdala GMV Images were acquired from 27 BPI (17 euthymic, 10 depressed) and 28 age- and gender-matched HC in a 3T Siemens scanner. Data were analyzed with SPM5 using voxel-based morphometry (VBM) to assess main effects of diagnostic group and gender upon whole brain (WB) GMV. Post-hoc analyses were subsequently performed using SPSS to examine the extent to which clinical and illness history variables and psychotropic medication contributed to GMV abnormalities in BPI in a priori and non-a priori regions has demonstrated by the above VBM analyses. BPI showed reduced GMV in bilateral posteromedial rectal gyrus (PMRG), but no abnormalities in amygdala GMV. BPI also showed reduced GMV in two non-a priori regions: left parahippocampal gyrus and left putamen. For left PMRG GMV, there was a significant group by gender by trait anxiety interaction. GMV was significantly reduced in male low-trait anxiety BPI versus male low-trait anxiety HC, and in high-versus low-trait anxiety male BPI. Our results show that in BPI there were significant effects of gender and trait-anxiety, with male BPI and those high in trait-anxiety showing reduced left PMRG GMV. PMRG is part of medial prefrontal network implicated in visceromotor and emotion regulation. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Noninvasive assessment of cardiac structure and function is essential to understand the natural course of murine infection with Trypanosoma cruzi. Magnetic resonance imaging (MRI) and echocardiography have been used to monitor anatomy and function; positron emission tomography (PET) is ideal for monitoring metabolic events in the myocardium. Mice infected with T. cruzi (Brazil strain) were imaged 15-100 days post infection (dpi). Quantitative (18)F-FDG microPET imaging, MRI and echocardiography were performed and compared. Tracer ((18)F-FDG) uptake was significantly higher in infected mice at all days of infection, from 15 to 100 dpi. Dilatation of the right ventricular chamber was observed by MRI from 30 to 100 dpi in infected mice. Echocardiography revealed significantly reduced ejection fraction by 60 dpi. Combination of these three complementary imaging modalities makes it possible to noninvasively quantify cardiovascular function, morphology, and metabolism from the earliest days of infection through the chronic phase.
Resumo:
Introduction. In view of the high prevalence of headache in the general population, the availability of well defined regarding the request of complementary exams is highly desirable. Aim. To analyze the criteria that will guide the physician requests of complementary exams during the investigation of headache. Patients and methods. The data were obtained by reviewing medical records of all patients who had been scheduled to be seen in a tertiary Headache Outpatient Clinic in 2004. Results. The exam most frequently requested was computed tomography of the head and the exams that most contributed to a change in clinical diagnosis or medical conduct were computed tomography of paranasal sinuses, simple rediography of paranasal sinuses. and magnetic resonance image of the brain. The exams that did not contribute to a change in the diagnosis or medical conduct were computed tomography and simple radiography of the cervical spine. As expected, the most expensive exams for the institution were computed tomography and magnetic resonance image. Conclusion. The importance of complementary exams in the investigation of headache is indisputable in many cases. Howerer, it is necessary the availability of more, studies that evaluate the request of complementay ; exams for headache patients. [REV NEUROL 2009: 48: 183-7]
Resumo:
Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962
Resumo:
A time efficient optical model is proposed for GATE simulation of a LYSO scintillation matrix coupled to a photomultiplier. The purpose is to avoid the excessively long computation time when activating the optical processes in GATE. The usefulness of the model is demonstrated by comparing the simulated and experimental energy spectra obtained with the dual planar head equipment for dosimetry with a positron emission tomograph ( DoPET). The procedure to apply the model is divided in two steps. Firstly, a simplified simulation of a single crystal element of DoPET is used to fit an analytic function that models the optical attenuation inside the crystal. In a second step, the model is employed to calculate the influence of this attenuation in the energy registered by the tomograph. The use of the proposed optical model is around three orders of magnitude faster than a GATE simulation with optical processes enabled. A good agreement was found between the experimental and simulated data using the optical model. The results indicate that optical interactions inside the crystal elements play an important role on the energy resolution and induce a considerable degradation of the spectra information acquired by DoPET. Finally, the same approach employed by the proposed optical model could be useful to simulate a scintillation matrix coupled to a photomultiplier using single or dual readout scheme.
Resumo:
This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multi-well plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (similar to 180 mu m), require small volumes of sample (5 mu L per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (similar to 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was aproximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader.