82 resultados para receiver operating characteristic curve


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Optical spectroscopy is a noninvasive technique with potential applications for diagnosis of oral dysplasia and early cancer. In this study, we evaluated the diagnostic performance of a depth-sensitive optical spectroscopy (DSOS) system for distinguishing dysplasia and carcinoma from non-neoplastic oral mucosa. METHODS: Patients with oral lesions and volunteers without any oral abnormalities were recruited to participate. Autofluorescence and diffuse reflectance spectra of selected oral sites were measured using the DSOS system. A total of 424 oral sites in 124 subjects were measured and analyzed, including 154 sites in 60 patients with oral lesions and 270 sites in 64 normal volunteers. Measured optical spectra were used to develop computer-based algorithms to identify the presence of dysplasia or cancer. Sensitivity and specificity were calculated using a gold standard of histopathology for patient sites and clinical impression for normal volunteer sites. RESULTS: Differences in oral spectra were observed in: (1) neoplastic versus nonneoplastic sites, (2) keratinized versus nonkeratinized tissue, and (3) shallow versus deep depths within oral tissue. Algorithms based on spectra from 310 nonkeratinized anatomic sites (buccal, tongue, floor of mouth, and lip) yielded an area under the receiver operating characteristic curve of 0.96 in the training set and 0.93 in the validation set. CONCLUSIONS: The ability to selectively target epithelial and shallow stromal depth regions appeared to be diagnostically useful. For nonkeratinized oral sites, the sensitivity and specificity of this objective diagnostic technique were comparable to that of clinical diagnosis by expert observers. Thus, DSOS has potential to augment oral cancer screening efforts in community settings. Cancer 2009;115:1669-79. (C) 2009 American Cancer Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the performance of a novel procedure for segmenting mammograms and detecting clustered microcalcifications in two types of image sets obtained from digitization of mammograms using either a laser scanner, or a conventional ""optical"" scanner. Specific regions forming the digital mammograms were identified and selected, in which clustered microcalcifications appeared or not. A remarkable increase in image intensity was noticed in the images from the optical scanner compared with the original mammograms. A procedure based on a polynomial correction was developed to compensate the changes in the characteristic curves from the scanners, relative to the curves from the films. The processing scheme was applied to both sets, before and after the polynomial correction. The results indicated clearly the influence of the mammogram digitization on the performance of processing schemes intended to detect microcalcifications. The image processing techniques applied to mammograms digitized by both scanners, without the polynomial intensity correction, resulted in a better sensibility in detecting microcalcifications in the images from the laser scanner. However, when the polynomial correction was applied to the images from the optical scanner, no differences in performance were observed for both types of images. (C) 2008 SPIE and IS&T [DOI: 10.1117/1.3013544]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: We sought to evaluate the predictive validity of the Waterlow Scale in hospitalized patients. SUBJECTS AND SETTING: The study was conducted at a general private hospital with 220 beds and a mean time of hospitalization of 7.4 days and a mean occupation rate of approximately 80%. Adult patients with a Braden Scale score of 18 or less and a Waterlow Scale score of 16 or more were studied. The sample consisted of 98 patients with a mean age of 71.1 +/- 15.5 years. METHODS: Skin assessment and scoring by using the Waterlow and Braden scales were completed on alternate days. Patients were examined at least 3 times to be considered for analysis. The data were submitted to sensitivity and specificity analysis by using receiver operating characteristic (ROC) curves and positive (+LR) and negative (-LR) likelihood ratios. RESULTS: The cutoff scores were 17, 20, and 20 in the first, second, and third assessment, respectively. Sensitivity was 71.4%, 85.7%, and 85.7% and specificity was 67.0%, 40.7%, and 32.9%, respectively. Analysis of the area under the ROC curve revealed good accuracy (0.64, 95% confidence interval [CI]: 0.35-0.93) only for the cutoff score 17 in the first assessment. The results also showed probabilities of 14%, 10%, and 9% for the development of pressure ulcer when the test results were positive (+LR) and of 3% (-LR) when the test results were negative for the cutoff scores in the first, second, and third assessment, respectively. CONCLUSION: The Waterlow Scale achieved good predictive validity in predicting pressure ulcer in hospitalized patients when a cutoff score of 17 was used in the first assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of cross-sectional arc calcification on the diagnostic accuracy of computed tomography (CT) angiography compared with conventional coronary angiography for the detection of obstructive coronary artery disease (CAD). Materials and Methods: Institutional Review Board approval and written informed consent were obtained from all centers and participants for this HIPAA-compliant study. Overall, 4511 segments from 371 symptomatic patients (279 men, 92 women; median age, 61 years [interquartile range, 53-67 years]) with clinical suspicion of CAD from the CORE-64 multi-center study were included in the analysis. Two independent blinded observers evaluated the percentage of diameter stenosis and the circumferential extent of calcium (arc calcium). The accuracy of quantitative multidetector CT angiography to depict substantial (>50%) stenoses was assessed by using quantitative coronary angiography (QCA). Cross-sectional arc calcium was rated on a segment level as follows: noncalcified or mild (<90 degrees), moderate (90 degrees-180 degrees), or severe (>180 degrees) calcification. Univariable and multivariable logistic regression, receiver operation characteristic curve, and clustering methods were used for statistical analyses. Results: A total of 1099 segments had mild calcification, 503 had moderate calcification, 338 had severe calcification, and 2571 segments were noncalcified. Calcified segments were highly associated (P < .001) with disagreement between CTA and QCA in multivariable analysis after controlling for sex, age, heart rate, and image quality. The prevalence of CAD was 5.4% in noncalcified segments, 15.0% in mildly calcified segments, 27.0% in moderately calcified segments, and 43.0% in severely calcified segments. A significant difference was found in area under the receiver operating characteristic curves (noncalcified: 0.86, mildly calcified: 0.85, moderately calcified: 0.82, severely calcified: 0.81; P < .05). Conclusion: In a symptomatic patient population, segment-based coronary artery calcification significantly decreased agreement between multidetector CT angiography and QCA to detect a coronary stenosis of at least 50%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: International nutritional screening tools are recommended for screening hospitalized patients for nutritional risk, but no tool has been specifically evaluated in the Brazilian population. The aim of this study was to identify the most appropriate nutritional screening tool for predicting unfavorable clinical outcomes in patients admitted to a Brazilian public university hospital. Methods: The Nutritional Risk Screening 2002 (NRS 2002), Mini-Nutritional Assessment-Short Form (MNA-SF), and Malnutrition Universal Screening Tool (MUST) were administered to 705 patients within 48 h of hospital admission. Tool performance in predicting complications, very long length of hospital stay (LOS), and death was analyzed using receiver operating characteristic curves. Results: NRS 2002, MUST, and MNA-SF identified nutritional risk in 27.9%, 39.6%, and 73.2% of the patients, respectively. NRS 2002 (complications: 0.6531; very long LOS: 0.6508; death: 0.7948) and MNA-SF(complications: 0.6495; very long LOS: 0.6197; death: 0.7583) had largest areas under the ROC curve compared to MUST (complications: 0.6036; very long LOS: 0.6109; death: 0.6363). For elderly patients, NRS 2002 was not significantly different than MNA-SF (P>0.05) for predicting outcomes. Conclusion: Considering current criteria for nutritional risk, NRS 2002 and MNA-SF have similar performance to predict outcomes but NRS 2002 seems to provide a best yield. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Follistatin is an activin-binding protein produced by several tissues, including endometrium and endometriotic implants. We aimed to quantify follistatin in patients with ovarian endometriosis and investigate its value as a diagnostic marker. Women undergoing laparoscopic excision of ovarian endometrioma (n = 52) or other benign ovarian cysts (n = 52) were studied, plus women with non-ovarian endometriosis (n = 11) and healthy controls (n = 27). Serum was collected from all subjects, and peritoneal and cystic fluid from a subset with endometrioma. Follistatin was measured by enzyme-linked immunosorbent assay. The diagnostic accuracy of follistatin to detect endometrioma was evaluated by receiver operating characteristic (ROC) curve and compared with cancer antigen (CA)-125. Serum follistatin was increased in women with ovarian endometrioma (2080 +/- 94 pg/ml) compared with controls (545 +/- 49 pg/ml, P < 0.001), other benign ovarian cysts (795 +/- 60 pg/ml, P < 0.001) or non-ovarian endometriosis (1271 +/- 115 pg/ml, P < 0.001). Cystic fluid showed a higher concentration of follistatin (9850 +/- 4461 pg/ml) than peritoneal fluid (1885 +/- 261 pg/ml, P < 0.001) and serum (P < 0.001). Follistatin levels detected 48/52 cases of endometrioma (92% sensitivity) at 1433 pg/ml cut-off, corresponding to 92% specificity. CA-125 detected only 44% of endometriomas with 90% specificity. ROC curve comparison showed follistatin was more accurate than CA-125 to discriminate women with endometrioma either from controls or women with other benign ovarian cysts (P < 0.0001). Serum follistatin is increased in women with endometriosis and allows clear distinction between endometrioma and other benign ovarian cysts. Follistatin has the sensitivity and specificity to become a useful clinical marker of ovarian endometrioma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow cytometry-adapted fluorescent antibody to membrane antigen (FAMA) assay to detect IgG antibodies against varicella-zoster virus (VZV) was developed and tested in 62 serum samples, showing 90.32% accuracy obtained from a receiver operating characteristic (ROC) curve with a 0.9125 (95% confidence interval [CI], 0.829 to 1.00) area below the curve compared to the result with standard FAMA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnosis of autoimmune hepatitis (AIH) may be challenging. However, early diagnosis is important because immunosuppression is life-saving. Diagnostic criteria of the International Autoimmune Hepatitis Group (IAIHG) were complex and purely meant for scientific purposes. This study of the IAIHG aims to define simplified diagnostic criteria for routine clinical practice. Candidate criteria included sex, age, autoantibodies, immunoglobutins, absence of viral hepatitis, and histology. The training set included 250 AIH patients and 193 controls from 11 centers worldwide. Scores were built from variables showing predictive ability in univariate analysis. Diagnostic value of each score was assessed by the area under the receiver operating characteristic (ROC) curve. The best score was validated using data of an additional 109 AIH patients and 284 controls. This score included autoantibodies, immunoglobulin G, histology, and exclusion of viral hepatitis. The area under the curve for prediction of AIH was 0.946 in the training set and 0.91 in the validation set. Based on the ROC curves, two cutoff points were chosen. The score was found to have 88% sensitivity and 97% specificity (cutoff >= 6) and 81% sensitivity and 99% specificity (cutoff 2:7) in the validation set. Conclusion: A reliable diagnosis of AIH can be made using a very simple diagnostic score. We propose the diagnosis of probable AIH at a cutoff point greater than 6 points and definite AIH 7 points or higher.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Analisar a acurácia do diagnóstico de dois protocolos de imunofluorescência indireta para leishmaniose visceral canina. MÉTODOS: Cães provenientes de inquérito soroepidemiológico realizado em área endêmica nos municípios de Araçatuba e de Andradina, na região noroeste do estado de São Paulo, em 2003, e área não endêmica da região metropolitana de São Paulo, foram utilizados para avaliar comparativamente dois protocolos da reação de imunofluorescência indireta (RIFI) para leishmaniose: um utilizando antígeno heterólogo Leishmania major (RIFI-BM) e outro utilizando antígeno homólogo Leishmania chagasi (RIFI-CH). Para estimar acurácia utilizou-se a análise two-graph receiver operating characteristic (TG-ROC). A análise TG-ROC comparou as leituras da diluição 1:20 do antígeno homólogo (RIFI-CH), consideradas como teste referência, com as diluições da RIFI-BM (antígeno heterólogo). RESULTADOS: A diluição 1:20 do teste RIFI-CH apresentou o melhor coeficiente de contingência (0,755) e a maior força de associação entre as duas variáveis estudadas (qui-quadrado=124,3), sendo considerada a diluição-referência do teste nas comparações com as diferentes diluições do teste RIFI-BM. Os melhores resultados do RIFI-BM foram obtidos na diluição 1:40, com melhor coeficiente de contingência (0,680) e maior força de associação (qui-quadrado=80,8). Com a mudança do ponto de corte sugerido nesta análise para a diluição 1:40 da RIFI-BM, o valor do parâmetro especificidade aumentou de 57,5% para 97,7%, embora a diluição 1:80 tivesse apresentado a melhor estimativa para sensibilidade (80,2%) com o novo ponto de corte. CONCLUSÕES: A análise TG-ROC pode fornecer importantes informações sobre os testes de diagnósticos, além de apresentar sugestões sobre pontos de cortes que podem melhorar as estimativas de sensibilidade e especificidade do teste, e avaliá-los a luz do melhor custo-benefício.