36 resultados para internal information flow


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single interface flow systems (SIFA) present some noteworthy advantages when compared to other flow systems, such as a simpler configuration, a more straightforward operation and control and an undemanding optimisation routine. Moreover, the plain reaction zone establishment, which relies strictly on the mutual inter-dispersion of the adjoining solutions, could be exploited to set up multiple sequential reaction schemes providing supplementary information regarding the species under determination. In this context, strategies for accuracy assessment could be favourably implemented. To this end, the sample could be processed by two quasi-independent analytical methods and the final result would be calculated after considering the two different methods. Intrinsically more precise and accurate results would be then gathered. In order to demonstrate the feasibility of the approach, a SIFA system with spectrophotometric detection was designed for the determination of lansoprazole in pharmaceutical formulations. Two reaction interfaces with two distinct pi-acceptors, chloranilic acid (CIA) and 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) were implemented. Linear working concentration ranges between 2.71 x 10(-4) to 8.12 x 10(-4) mol L(-1) and 2.17 x 10(-4) to 8.12 x 10(-4) mol L(-1) were obtained for DDQ and CIA methods, respectively. When compared with the results furnished by the reference procedure, the results showed relative deviations lower than 2.7%. Furthermore. the repeatability was good, with r.s.d. lower than 3.8% and 4.7% for DDQ and CIA methods, respectively. Determination rate was about 30 h(-1). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel flow-based strategy for implementing simultaneous determinations of different chemical species reacting with the same reagent(s) at different rates is proposed and applied to the spectrophotometric catalytic determination of iron and vanadium in Fe-V alloys. The method relies on the influence of Fe(II) and V(IV) on the rate of the iodide oxidation by Cr(VI) under acidic conditions, the Jones reducing agent is then needed Three different plugs of the sample are sequentially inserted into an acidic KI reagent carrier stream, and a confluent Cr(VI) solution is added downstream Overlap between the inserted plugs leads to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions reveal the different degrees of reaction development and tend to be more precise Data are treated by multivariate calibration involving the PLS algorithm The proposed system is very simple and rugged Two latent variables carried out ca 95% of the analytical information and the results are in agreement with ICP-OES. (C) 2010 Elsevier B V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research employs solid-state actuators for delay of flow separation seen in airfoils at low Reynolds numbers. The flow control technique investigated here is aimed for a variable camber airfoil that employs two active surfaces and a single four-bar (box) mechanism as the internal structure. To reduce separation, periodic excitation to the flow around the leading edge of the airfoil is induced by a total of nine piezocomposite actuated clamped-free unimorph benders distributed in the spanwise direction. An electromechanical model is employed to design an actuator capable of high deformations at the desired frequency for lift improvement at post-stall angles. The optimum spanwise distribution of excitation for increasing lift coefficient is identified experimentally in the wind tunnel. A 3D (non-uniform) excitation distribution achieved higher lift enhancement in the post-stall region with lower power consumption when compared to the 2D (uniform) excitation distribution. A lift coefficient increase of 18.4% is achieved with the identified non-uniform excitation mode at the bender resonance frequency of 125 Hz, the flow velocity of 5 m/s and at the reduced frequency of 3.78. The maximum lift (Clmax) is increased 5.2% from the baseline. The total power consumption of the flow control technique is 639 mW(RMS).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In an energy perspective of cost-reduction and configuration-optimization, it becomes necessary to develop and use advanced tools for the analysis, design and improvement of energy conversion systems. In the aeronautical industry, such trend is fundamental since this industry has evolved to design extremely complex aircrafts, with highly integrated systems, requiring more information in order to evaluate the whole system. The aim of this paper is to present an exergy-based analysis as to evaluate the global performance of a typical turbofan engine and its components. The study presents values for exergy efficiency over the whole flight cycle, critical equipment and flight phases considering exergy destruction and estimating internal and exhaust flow costs. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Static mixers with improved performance were developed from CFD simulations in a stepwise approach. The relevant geometric features of simple mixer designs and the corresponding mixing mechanisms-laminar shear, elongational flow, and distributive mixing-were identified first. This information was used to formulate guidelines for the development of new geometries. The solid elements of the static mixer should: (a) provide restrictions to the flow; (b) deflect the flow; (c) be sequentially rotated around the flow direction to provide symmetry; (d) extend from the center of the pipe to the vicinity of the walls to avoid short-circuiting; and (e) distribute and remix the flow. Based on these guidelines, two improved mixer designs were developed: the DS A-I mixer has a good mixing efficiency and an acceptable pressure drop; the Fins 35 degrees mixer is more efficient and compact, but requires a larger pressure drop. Their performance indicates that their use is possible on industrial applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The feasibility of characterizing the dynamics of a spouted bed based on acoustic emission (AE) signals is evaluated. Acoustic emission signals were measured in a semi-cylindrical Plexiglas column of diameter 150 mm and height 1000 mm with a conical base of internal angle 60 degrees and 25 mm inlet orifice diameter. Data were obtained for U/U(ms), from 0.3 to 2.0, static bed height from 250 to 500 mm, and glass beads of diameter 1.2 and 2.4 mm. AE signals reflected the effects of particle size and U/U(ms), but in general were insensitive to bed depth, even when there were drastic changes in spouting flow patterns. The results indicate that the AE signals were insensitive to the spouted bed hydrodynamics for the conditions studied. Overall, it appears that the AE analysis is unlikely to be a suitable technique for discriminating spouted bed flow regimes, at least for the range of frequencies and operating conditions investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To report a series of patients with symptomatic internal carotid artery (ICA) occlusion treated with angioplasty and stents. MATERIALS AND METHODS: From a consecutive series of 50 patients experiencing neurologic ischemic symptoms and shown by conventional ultrasonography (US) to have a total ICA occlusion, 16 patients (ages 45-79 years; mean, 63 y; 10 men) were selected between August 2006 to September 2008 to be treated with angioplasty based on discovery of an open ICA distal to the occlusion through contrast-enhanced echo Doppler imaging and/or multislice contrast computed tomography (CT). Angioplasty and stent placement were performed under cerebral protection. Follow-up duplex imaging was performed at 14 days and 3 months and every 6 months thereafter and CT follow-up was performed at 2-9 months; the mean follow-up period was 9.9 months. RESULTS: Lesion crossing and stent placement was successful in 13 of 16 patients. There were no deaths, conversions, cardiac complications, or major strokes. One patient had a transient mild hemiparesis in the upper limb, with total recovery in 3 months. At follow-up, all 13 patients with a good initial result remained with patent arterial lumens and resolution of neurologic ischemic symptoms. After 2-9 months, ICAs with a ""string sign"" had calibers close or equal to those of normal arteries. CONCLUSIONS: Angioplasty with stent placement is an effective treatment with a low morbidity rate for selected patients who continue to experience neurologic ischemic symptoms despite US findings of total occlusion of the ICA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Perforating arteries are commonly involved during the surgical dissection and clipping of intracranial aneurysms. Occlusion of perforating arteries is responsible for ischemic infarction and poor outcome. The goal of this study is to describe the usefulness of near-infrared indocyanine green videoangiography (ICGA) for the intraoperative assessment of blood flow in perforating arteries that are visible in the surgical field during clipping of intracranial aneurysms. In addition, we analyzed the incidence of perforating vessels involved during the aneurysm surgery and the incidence of ischemic infarct caused by compromised small arteries. METHODS: Sixty patients with 64 aneurysms were surgically treated and prospectively included in this study. Intraoperative ICGA was performed using a surgical microscope (Carl Zeiss Co., Oberkochen, Germany) with integrated ICGA technology. The presence and involvement of perforating arteries were analyzed in the microsurgical field during surgical dissection and clip application. Assessment of vascular patency after clipping was also investigated. Only those small arteries that were not visible on preoperative digital subtraction angiography were considered for analysis. RESULTS: The ICGA was able to visualize flow in all patients in whom perforating vessels were found in the microscope field. Among 36 patients whose perforating vessels were visible on ICGA, 11 (30%) presented a close relation between the aneurysm and perforating arteries. In one (9%) of these 11 patients, ICGA showed occlusion of a P1 perforating artery after clip application, which led to immediate correction of the clip confirmed by immediate reestablishment of flow visible with ICGA without clinical consequences. Four patients (6.7%) presented with postoperative perforating artery infarct, three of whom had perforating arteries that were not visible or distant from the aneurysm. CONCLUSION: The involvement of perforating arteries during clip application for aneurysm occlusion is a usual finding. Intraoperative ICGA may provide visual information with regard to the patency of these small vessels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the relationship between ductus venosus Doppler findings on the day of delivery and postnatal outcomes in pregnancies with absent or reversed end-diastolic (ARED) flow in the umbilical arteries. Study design: Postnatal outcomes of 103 newborns of pregnancies with a diagnosis of ARED flow on Doppler velocimetry of the umbilical arteries were analyzed retrospectively between January 1997 and December 2004. Single pregnancies and fetuses without malformations were included. The cases were divided into two groups according to the flow during atrial contraction (a-wave) in the ductus venosus on the day of delivery: group A, 20 cases with absent or reversed flow in the ductus venosus and group B, 83 cases with positive flow. The results were analyzed statistically using the chi-square test, Fisher`s exact test and the Mann-Whitney U test with the level of significance set at 5%. Results: All newborns were delivered by cesarean section. Gestational age was similar in the two groups (group A: 30 weeks and group B: 30.9 weeks, P = 0.23). Absent or reversed ductus venosus flow was associated with the following adverse postnatal outcomes: lower birthweight (P < 0.001), lower Apgar scores in the first (P = 0.001) and fifth minute (P = 0.001), a higher frequency of orotracheal intubation (P = 0.001) and pH at birth less than 7.20 (P < 0.001), pulmonary hemorrhage (P = 0.03), thrombocytopenia (P = 0.02), hypoglycemia (P = 0.01), intracranial hemorrhage (P = 0.02), and postnatal death (P = 0.007). Conclusion: The study of ductus venosus flow may provide additional information regarding the best time for interruption of pregnancies with ARED flow in the umbilical arteries characterized by extreme prematurity. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the lipid profile, insulin resistance and vasomotricity, and the interaction between these factors, in postmenopausal women receiving hormone therapy. Methods: A prospective, randomized, double-blind study was carried out in which 77 postmenopausal women received one of the three treatment regimens: (A) 2 mg oral micronized estradiol (E(2)) (n = 25); (B) 2 mg oral E(2) + 1 mg oral norethisterone acetate (NETA) (n = 28); or Q placebo (n = 24), daily for 6 months. Evaluations were carried out at baseline and at the end of treatment on lipid and lipoprotein profiles, homeostasis model assessment of insulin resistance (HOMA-IR) and pulsatility index (PI) of the internal carotid artery by Doppler ultrasonography. Results: Mean increases of 15.6% and 2.4% and a reduction of 6.4% in high-density lipoprotein (HDL) levels were found for the E(2), E(2) + NETA and placebo groups, respectively. Reductions of 9.5% and 3.7% and an increase of 12.1% in low-density lipoprotein (LDL), and reductions of 20.0% and 3.8% and an increase of 28.8% in the LDL:HDL ratio were found for the E(2), E(2) + NETA and placebo groups, respectively (p < 0.001 in all cases). Insulin levels and HOMA-IR decreased 12.8% and 12.3% in the E2 group and increased 12.9% and 16.0% in the E(2) + NETA group (p < 0.05), respectively. Carotid PI following treatment was 1.18 +/- 0.23, 1.38 +/- 0.20 and 1.41 +/- 0.21 for the E(2), E(2) + NETA and placebo groups, respectively (p = 0.0006). Conclusions: Oral estrogen therapy led to an improvement in lipid profile, insulin resistance and carotid blood flow, which was cancelled when NETA was associated. (c) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alouatta guariba clamitans (brown howler monkey) is an endemic primate from the southeastern Brazil tropical forests, classified as near threatened by the IUCN Red List 2007. The genus Aloualta is one of the most difficult New World monkeys to breed and rear in captivity. In this study we examined the macroscopic and histological aspects of the female genital tract of wild brown howler monkeys to provide baseline information for future reproduction research. The anatomical relationship between the vagina, uterus, broad ligament, oviducts and ovaries are those of a typical primate reproductive tract. The fundic portion of the uterus is globoid, the cervix is well developed, which confers to the uterus an elongated shape, and the vagina is a long flattened channel. Histological analysis conducted in females in the follicular phase revealed large quantities of interstitial luteinized tissue in the ovaries, a stratified nonkeratinized vaginal epithelium, lack of glands in the vaginal mucosa and simple tubular endometrial glands. The observed anatomical features should be considered in the adaptation and application of assisted reproductive techniques aimed at improving captive reproduction for species conservation. Am. J. Primatol. 71:145-152, 2009. (C) 2008 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Endothelin-1 (ET-1), a potent vasoconstrictor peptide, acts mainly through the Gprotein-coupled ET(A) receptor (ET(A)R). Increased vascular ET-1 production and constrictor sensitivity have been observed in various cardiovascular diseases, including hypertension, as well as erectile dysfunction. The internal pudendal artery (IPA) supplies blood to the vagina and clitoris. Inadequate blood flow through the IPA may lead to insufficient vaginal engorgement and clitoral tumescence. Aim. Characterize the effects of ET-1 on the IPA and clitoral artery (CA). Methods. IPA and CA from female Sprague Dawley rats (225-250 g) were mounted in myograph chambers. Arterial segments were submitted to increasing concentrations of ET-1 (10-10-10-6 M). Segments were incubated with the ET(A)R antagonist, atrasentan (10-8 M) or the Rho-kinase inhibitor, Y-27632 (10-6 M) 30 minutes prior to agonist exposure. All E(max) values are expressed as % KCl-induced maximal contraction. ET(A)R, RhoA, and Rho-kinase expression from IPA was evaluated by Western blot. mRNA of preproET-1, ET(A)R, ET(B)R, RhoA, and Rho-kinase were measured by real time PCR. Main Outcome Measures. ET-1 constrictor sensitivity in IPA and CA, protein expression and messenger RNA levels of ET-1-mediated constriction components. Results. ET-1 concentration-dependently contracted IPA (% Contraction and pD2, respectively: 156 +/- 18, 8.2 +/- 0.1) and CA (163 +/- 12, 8.8 +/- 0.08), while ET(A)R antagonism reduced ET-1-mediated contraction (IPA: 104 +/- 23, 6.4 +/- 0.2; CA: 112 +/- 17, 6.6 +/- 0.08). Pretreatment with Y-27632 significantly shifted ET-1 pD2 in IPA (108 +/- 24, 7.9 +/- 0.1) and CA (147 +/- 58 and 8.0 +/- 0.25). Protein expression of ET(A)R, ET(B)R, RhoA, and Rho-kinase were detected in IPA. IPA and CA contained preproET-1, ET(A)R, ET(B)R, RhoA, and Rho-kinase message. Conclusion. We observed that the IPA and CA are sensitive to ET-1, signaling through the ET(A)R and Rho-kinase pathway. These data indicate that ET-1 may play a role in vaginal and clitoral blood flow and may be important in pathologies where ET-1 levels are elevated. Allahdadi KJ, Hannan JL, Tostes RC, and Webb RC. Endothelin-1 induces contraction of female rat internal pudendal and clitoral arteries through ETA receptor and Rho-kinase activation. J Sex Med 2010;7:2096-2103.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, the great saphenous vein is the vascular conduit that is most frequently employed in coronary and peripheral revascularization surgery. It is known that saphenous vein bypass grafts have shorter patency than arterial ones, partly because the wall of the normal saphenous vein has different structural and functional characteristics. The features of this vein can be affected by the large distention pressures it is submitted to during its preparation and insertion into the arterial system. Indeed, a vein graft is subjected to considerable changes in hemodynamic forces upon implantation into the arterial circulation, since it is transplanted from a non-pulsatile, low-pressure, low-flow environment with minimal shear stress to a high-pressure system with pulsatile flow, where it undergoes cyclic strain and elevated shear. These changes can be responsible for functional and morphological alterations in the vessel wall, culminating in intima hyperproliferation and atherosclerotic degeneration, which contribute to early graft thrombosis. This review has followed a predetermined strategy for updating information on the human saphenous vein (HSV). Besides presenting the aspects relative to the basic pharmacology, this text also includes surgical aspects concerning HSV harvesting, the possible effects of the major groups of cardiovascular drugs on the HSV, and finally the interference of major cardiovascular diseases in the vascular reactivity of the HSV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the first part some information and characterisation about an AC distribution network that feeds traction substations and their possible influences on the DC traction load flow are presented. Those influences are investigated and mathematically modelled. To corroborate the mathematical model, an example is presented and their results are confronted with real measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rotationally-split modes can provide valuable information about the internal rotation profile of stars. This has been used for years to infer the internal rotation behavior of the Sun. The present work discusses the potential additional information that rotationally splitting asymmetries may provide when studying the internal rotation profile of stars. We present here some preliminary results of a method, currently under development, which intends: 1) to understand the variation of the rotational splitting asymmetries in terms of physical processes acting on the angular momentum distribution in the stellar interior, and 2) how this information can be used to better constrain the internal rotation profile of the stars. The accomplishment of these two objectives should allow us to better use asteroseismology as a test-bench of the different theories describing the angular momentum distribution and evolution in the stellar interiors. (C) 2010 WILEY-VCH Verlag GmbH&Co. KGaA, Weinheim